Crack Control Performance of the RC Composite Slabs Produced with Extruded ECC Panel (압출성형 ECC 패널을 이용한 RC슬래브의 균열제어성능)

  • Kim, Yun-Yong;Lee, Jong-Han;Cho, Chang-Geun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.95-96
    • /
    • 2010
  • This paper presents the crack control of reinforcement concrete composite slabs which were produced with the extruded ECC panel. Cracking control performance was evaluated based on the flexural tests on real scale one-way slabs manufactured with or without ECC panel.

  • PDF

Flexural Test on Composite Deck Slab Produced with Extruded ECC Panel (압출성형 ECC 패널을 이용하여 제작된 복합바닥슬래브의 휨 거동)

  • Cho, Chang-Geun;Han, Byung-Chan;Lee, Jong-Han;Kim, Yun-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.5
    • /
    • pp.695-702
    • /
    • 2010
  • This paper presents a reinforced concrete composite deck slab system newly developed using a high ductile ECC extrusion panel. In the construction practice, the cracking of reinforced concrete slab often becomes a problem especially in parking garages, underground structures, and buildings. The ECC panel manufactured by extrusion process as a precast product has not only a high-quality in control of cracking but also a merit in applying the construction of concrete slab because the use of ECC panel can realize a formless or half-precast construction with cast-in-place concrete. In the newly developed deck slab system, the ECC extrusion panel is located in the bottom of slab with the thickness of 10 mm, reinforcements are assembled and located on the ECC panel, and finally the topping concrete is placed in the field. In order to evaluate the newly developed slab system, experimental works by four point bending test are conducted to compare with the conventional reinforced concrete slab system. From experiment, the developed deck slab system using a ECC panel gives many improved performances both in control of bending cracking and in load-carrying capacities of slabs.

Application of Waste Concrete Powder as Silica Powder of Cement Extruding Panel (시멘트 압출패널의 규사분말 대체재로서 폐콘크리트 미립분의 활용)

  • Kim, Jin-Man;Kim, Kee-Seok;La, Jung-Min;Choi, Duck-Jin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.1
    • /
    • pp.88-94
    • /
    • 2011
  • To make recycling aggregate, quantity of fine particles increase due to multi-crushing. Though this particles were mixed with recycling aggregate, those have to be disparted from aggregate in the high quality recycling aggregate, because of the cause of low quality. Considering reactivity, fine particles is better than coarse one. Therefore, it needs to develop suitable usage. We try to make cement extruding material by using the fine particles from concrete recycling, as a silicious replacement. Test results are as follows ; 1) Waste concrete powder has major ingredients such as $SiO_2$ and CaO, its density is $2.45g/cm^3$ being similar to silica powder, its diameter is range 13 to $141{\mu}m$. 2) Considering to strength properties according to particle size, specimen was made using small particles is higher strength than large one. 3) Despite of exception in the autoclaved curing, when the replacement of waste fine particle increase, strength of extruding panel shows almost same level.

  • PDF

Thermal Properties of the Cement Extruding Panel with Waste concrete Powder (폐 콘크리트 미분을 혼입한 시멘트 압출성형 패널의 열적특성)

  • Choi, Duck-Jin;Hong, Sung-Rog;Lee, Min-Jae;Kim, Jang-Yup;Kim, Jin-Man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.283-286
    • /
    • 2012
  • According to increase of the waste concrete occurrence, recycling has being important more and more. This study is to recycle the waste concrete powder, which is occurred in dry-process during recycling of construction waste. We have tried the waste concrete powder to apply as the replacement of the silica powder in cement extruding product. As a result, it is satisfied that the autoclave cured pannel of 50% replacement ratio of waste concrete powder staisty the level of the flexural strength of 14MPa stipulated by "KS F 4735 Extruding concrete panel" was the same thermal properties as base specimen.

  • PDF

Analysis Model of Extruded ECC Panel RC Composite Slabs (압출성형 ECC 패널 RC 복합 슬래브의 해석모델)

  • Cho, Chang-Geun;Kim, Yun-Yong;Seo, Jeong-Hwan;Lee, Seung-Jung
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2012
  • A model for the nonlinear flexural analysis of extruded Engineered Cementitious Composite (ECC) panel reinforced concrete (RC) composite slab has been newly presented. From direct tensile test, ECC panel has been modeled to have the high-ductile tensile behavior after cracking. The developed model was compared with bending test results of two specimens, a conventional RC slab and a ECC panel RC composite slab. The predicted results were well patched with the experimental results, and the ECC panel RC composite slab system had advantages in crack control and improving flexural load-carrying capacity and deformation-capacity.

Engineering Performance of Extruded Fly Ash Cement Panel with Bottom Ash (잔골재로서의 바텀애시를 사용한 플라이애시 시멘트 압출경화체의 공학적 특성)

  • Lee, Myeong-Jin;Kim, Jin-Man;Han, Dong-Yeop;Choi, Duck-Jin;Lee, Keun-Woo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.3
    • /
    • pp.252-260
    • /
    • 2015
  • The aim of this research is providing the fundamental data for treating and recycling the byproducts by using the wet processed bottom ash as a fine aggregate replacement for cement-based extruded panel. Although the cement-based extruded panel was used mainly as a cladding component with its high strength and outstanding durability, it was hardly spread because of low economic feasibility due to the high cost of additives or fibers which were used to achieve 14 MPa of flexural strength as a cladding material. As a solution of this drawback, by the previous research, it was possible to replace cement by fly ash up to 80 % by decreasing quality criteria with restricting the application to indoor purpose. In this research, based on the previous research, by using the bottom ash as a replacement of fly ash, improvement of shape retention performance is tried. As a result of the experiment on evaluating the optimum content and PSD of bottom ash, as the fineness modulus and content of bottom ash was increased, the extruding performance was decreased and penetration resistance was increased. Additionally, the optimum content and the maximum particle size was found as 20 %, and 0.3 mm, respectively.

Fiber Distribution Characteristics and Flexural Performance of Extruded ECC Panel (압출성형 ECC 패널의 섬유분포 특성과 휨 성능)

  • Lee, Bang-Yeon;Han, Byung-Chan;Cho, Chang-Geun;Kwon, Young-Jin;Kim, Yun-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.5
    • /
    • pp.573-580
    • /
    • 2009
  • This paper presents the mix composition, production method, and curing condition applied to the extruded ECC(Engineered Cementitious Composite) panel which are able to exhibit multiple cracking and potential pseudo strain-hardening behavior. In addition to the production technique of extruded ECC panel, the effect of fiber distribution characteristics, which are uniquely created by applying extrusion process, on the flexural behavior of the panel is also focussed. In order to demonstrate fiber distribution, a series of experiments and analyses, including image processing/analysis and micro-mechanical analysis, was performed. The optimum mix composition of extruded ECC panel was determined in terms of water matrix ratio, the amount of cement, ECC powder, and silica powder. It was found that flexural behavior of extruded ECC panel was highly affected by the slight difference in mix composition of ECC panel. This is mainly because the difference in mix composition results in the change of micro-mechanical properties as well as fiber distribution characteristics, represented by fiber dispersion and orientation. In terms of the average fiber orientation, the fiber distribution was found to be similar to the assumption of two dimensional random distribution, irrespective of mix composition. In contrast, the probability density function for fiber orientation was measured to be quite different depending on the mix composition.

Fire-Resistance Property of Cement Extruding Panel Mixed with Alpha-Hemihydrate Gypsum (알파형 반수석고를 혼입한 시멘트 압출 패널의 내화특성)

  • Choi, Duck-Jin;Lee, Min-Jae;Shin, Sang-choul;Kim, Ki-Suk;Kim, Jin-Man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.109-110
    • /
    • 2011
  • Gypsum is an important building material used to provide fire resistance to constructions by reducing their temperature rises. As the hardened gypsum is exposed to fire, evaporation of both the free water and the chemical bond water is easier than that in the cement extruding panel. The purpose of this study is to investigate the utilizability of alpha-hemihydrate gypsum to prevent spalling failure of cement extruding panel exposed to fire. This paper reports the fire-resistance property of a controled general cement extruding panel(C100), and gypsum-cement extruding panels(C50A50, A100) according to replacement ratio of alpha-hemihydrate gypsum. As a results, it is found that A100 and C50A50 are more effective to prevent the explosive spalling failure under standard fire condition than C100.

  • PDF

Classification of Transmission Loss for Steel Panel and Extrusion Concrete Panel (건축용 철강제 벽판과 압출 성형 콘크리트 패널의 차음성능 구분)

  • 장길수;이태강;송민정;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.864-869
    • /
    • 2003
  • KS F 2808 was revised in 2000 and KS F 2862-1 was newly established in 2001. Thus Related Korean Industrial Standard such as KS F 4724, KS F 4735, KS F 4736 should be revised according to KS F 2808 and KS F 28612-1. This study aims to elicit the new rating numbers such as R$\sub$w/, R$\sub$w/+C, R$\sub$w/+C$\sub$tr/, L$\sub$m/ defined in KS F 2862-1 instead of exiting rating number; transmission loss of 500Hz.

  • PDF