• Title/Summary/Keyword: 신뢰성 측정

Search Result 3,159, Processing Time 0.034 seconds

A Case Analysis on the Spalling Evaluation of the Deep Rock Mass and Pillar Spalling Modeling (고심도 암반의 스폴링 평가에 대한 사례 분석 및 광주 스폴링 모델링)

  • Park, Seunghun;Kwon, Sangki;Lee, Changsoo;Lee, Jaewon;Yoon, Seok;Kim, Geon-Young
    • Tunnel and Underground Space
    • /
    • v.30 no.2
    • /
    • pp.109-135
    • /
    • 2020
  • Globally, the deepening depth in the underground is a situation of the high interest for a purpose of the development of various facilities. The development of deep underground space should be based on the structural stability of rocks. Spalling is known to have an impact on the structural stability degradation in deep underground space. As an attempt to predict spalling, many researchers have proposed predicted conditions in accordance with stress states which occur around the tunnel, rock conditions, and types of rock. In addition, the analysis on spalling method has been verified by using computer modeling such as FLAC, EXAMINE, Insight 2D, UDEC and FRACOD, along with in-situ measurement results. In Canada URL (Underground Research Tunnel), CWFS model (Cohesion Weakening Frictional Strengthening) was used to precisely predict for the state of spalling, comparing spalling modeling. CWFS model has been identified as a reliable method for predicting such phenomena. This study aims to analyze several cases of spalling, and then make a comparison between the conditions for spalling occurrence and the predicted results of model CWFS. With this, it investigates the applicability of prediction of spalling, targeting pillar under deep depth condition.

A Study on the Thermal Flow Analysis for Heat Performance Improvement of a Wireless Power Charger (열 유동해석을 통한 무선충전기 발열 성능 향상에 관한 연구)

  • Kim, Pyeong-Jun;Park, Dong-Kyou
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.310-316
    • /
    • 2019
  • In automotive application, customers are demanding high efficiency and various functions for convenience. The demand for these automotive applications is steadily increasing. In this study, it has been studied the analysis of heat flow to improve the PCB(printed circuit board) heating performance of WPC (wireless power charger) recently developed for convenience. The charging performance of the wireless charger has been reduced due to power dissipation and thermal resistance of PCB. Therefore, it has been proposed optimal PCB design, layout and position of electronic parts through the simulation of heat flow analysis and PCB design was analyzed and decided at each design stage. Then, the experimental test is performed to verify the consistency of the analysis results under actual environmental conditions. In this paper, The PCB modeling and heat flow simulation in transient response were performed using HyperLynx Thermal and FloTHERM. In addition, the measurement was performed using infrared thermal imaging camera and used to verify the analysis results. In the final comparison, the error between analysis and experiment was found to be less than 10 % and the heating performance of PCB was also improved.

Hydraulic Characteristics of Deep and Low Permeable Rock Masses in Gyeongju Area by High Precision Constant Pressure Injection Test (고정밀도 정압 주입시험에 의한 경주 지역 대심도 저투수성 암반 수리특성 연구)

  • Bae, SeongHo;Kim, Hagsoo;Kim, Jangsoon;Park, Eui Seob;Jo, Yeonguk;Ji, Taegu;Won, Kyung-Sik
    • Tunnel and Underground Space
    • /
    • v.31 no.4
    • /
    • pp.243-269
    • /
    • 2021
  • Since the early 2010s, the social importance of research and practical projects targeting deep geological disposal of high-level nuclear waste, underground CO2 storage and characterization of deep subsurface by borehole investigation has been increasing. In this regard, there is also a significant increase in the need for in situ test technology to obtain quantitative and reliable information on the hydraulic characteristics of deep rock mass. Through years of research and development, we have independently set up Deep borehole Hydraulic Test System (DHTS) based on the key apparatuses designed and made with our own technology. Using this system, high precision constant pressure injection tests were successfully completed at the two 1 km boreholes located in Mesozoic granite and sedimentary rock regions, Gyeongju. During the field tests, it was possible to measure very low flow rate below 0.01 l/min with micro flow rate injection/control module. In this paper, the major characteristics of DHTS are introduced and also some results obtained from the high precision field tests under the deep and low permeable rock mass environment are briefly discussed.

A Study on the Application Method of Artificial Injection Test according to the Hydraulic Conductivity of Aquifer (대수층 수리지질특성에 따른 인공함양시험 적용 방법에 관한 연구)

  • Chae, Dong-Seok;Choi, Jin-O;Jeong, Hyeon-Cheol;Kim, Chang-Yong
    • The Journal of Engineering Geology
    • /
    • v.31 no.4
    • /
    • pp.589-601
    • /
    • 2021
  • Artificial recharge technology is a method for solving problems such as groundwater level drop and ground subsidence caused by groundwater withdrawal. This study investigated the applicability of using the hydraulic conductivity of an aquifer to predict injection test results for aquifer restoration. Pumping and injection tests were performed under the same conditions as those for the artificial injection facility located in Icheon, Gyeonggi-do. The hydraulic conductivity of the aquifer, which plays a decisive role in restoring the groundwater level, was derived from the pumping test. A numerical model of a simplified on-site aquifer was constructed, and a transient analysis was applied with the same conditions as the pumping test. The correlation between the measured and the resulting model values is strong (R2 = 0.78). The injection test was performed in a sedimentary layer composed of silt sand and clay sand. From the results of the injection test, an empirical formula was derived using Theim's formula, which is a common well analysis solution to determine the parameters of the aquifer from time-level data. The model values from the empirical formula have a high degree of correlation (R2 = 0.99) with measured values. Under specific conditions, for areas where it is difficult to conduct an injection test, the formula from this study, which relies on the hydraulic conductivity of the aquifer determined through the pumping test, may be used to predict reliable injection rates for groundwater restoration.

Development and Validation of a Fun Perception Scale for the Korean Employees (직장인의 일에 대한 재미지각척도 개발 및 구성타당도 검증)

  • Cheongyeul Park ;Youngmi Sohn ;Chungwoon Kim
    • Korean Journal of Culture and Social Issue
    • /
    • v.17 no.2
    • /
    • pp.241-260
    • /
    • 2011
  • This study was to develop the fun perception scale measuring what conditions employees experience fun feeling in work and to examine the construct validity of it. For this, the pre-studies(open-ended questionnaire, in-depth interviews, literature survey, pre-survey) were conducted to develop the preliminary questions of fun scale. In main study, 250 employees(male: 125, female, 125) were responded to a questionnaire consisted of 40 questions of fun perception scale extracted by pre-studies. The results were as follow. First, through the item analysis, factor analysis and reliability analysis, 7 factors composed of 29 items were extracted: 'self-determination', 'extrinsic reward', 'goal achievement', 'pleasure in the process', 'contribution to the company', 'worthless', 'challenge'. Cronbach's alpha reliability coefficient of each factor was suitable. Secondly, EFA was conducted to test the construct validity of fun scale with AMOS 16.0. Several goodness of fit indexes were used to assess model fit: X2/df, TLI, CFI, RMSEA. The results were revealed that all the indexes were acceptable with no additional modification. Based on these findings, the theoretical and the practical implications of fun perception scale were discussed.

  • PDF

Evaluation of Uncertainty of IMRT QA Using 2Dimensional Array Detector for Head & Neck Patients (두경부암에서 2차원 배열 검출기를 이용한 IMRT QA의 불확실성에 대한 연구)

  • Ban, Tae-Joon;Lee, Woo-Suk;Kim, Dae-Sup;Baek, Geum-Mun;Kwak, Jung-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.2
    • /
    • pp.97-102
    • /
    • 2011
  • Purpose: IMRT QA using 2Dimensional array detector is carried out with condition for discrete dose distribution clinically. And it can affect uncertainty of evaluation using gamma method. We analyze gamma index variation according to grid size and suggest validate range of grid size for IMRT QA in Hospital. Materials and Methods: We performed QA using OniPro I'mRT system software version 1.7b on 10 patients (head and neck) for IMRT. The reference dose plane (grid size, 0.1 cm; location, [0, 0, 0]) from RTP was compared with the dose plane that has different grid size (0.1 cm, 0.5 cm, 1.0 cm, 2.0 cm, 4.0 cm) and different location (along Y-axis 0 cm, 0.2 cm, 0.5 cm, 1.0 cm). The gamma index variation was evaluated by observing the level of changes in Gamma pass rate, Average signal, Standard deviation for each case. Results: The average signal for each grid size showed difference levels of 0%, -0.19%, -0.04%, -0.46%, -8.32% and the standard deviation for each grid size showed difference levels of 0%, -0.30%, 1.24%, -0.70%, -7.99%. The gamma pass rate for each grid size showed difference levels of 0%, 0.27%, -1.43%, 5.32%, 5.60%. The gamma evaluation results according to distance in grid size range of 0.1 cm to 1.0 cm showed good agreement with reference condition (grid size 0.1 cm) within 1.5% and over 5% in case of the grid size was greater than 2.0 cm. Conclusion: We recognize that the grid size of gamma evaluation can make errors of IMRT QA. So we have to consider uncertainty of gamma evaluation according to the grid size and apply smaller than 2 cm grid size to reduce error and increase accuracy clinically.

  • PDF

Analysis of Variation for Parallel Test between Reagent Lots in in-vitro Laboratory of Nuclear Medicine Department (핵의학 체외검사실에서 시약 lot간 parallel test 시 변이 분석)

  • Chae, Hong Joo;Cheon, Jun Hong;Lee, Sun Ho;Yoo, So Yeon;Yoo, Seon Hee;Park, Ji Hye;Lim, Soo Yeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.51-58
    • /
    • 2019
  • Purpose In in-vitro laboratories of nuclear medicine department, when the reagent lot or reagent lot changes Comparability test or parallel test is performed to determine whether the results between lots are reliable. The most commonly used standard domestic laboratories is to obtain %difference from the difference in results between two lots of reagents, and then many laboratories are set the standard to less than 20% at low concentrations and less than 10% at medium and high concentrations. If the range is deviated from the standard, the test is considered failed and it is repeated until the result falls within the standard range. In this study, several tests are selected that are performed in nuclear medicine in-vitro laboratories to analyze parallel test results and to establish criteria for customized percent difference for each test. Materials and Methods From January to November 2018, the result of parallel test for reagent lot change is analyzed for 7 items including thyroid-stimulating hormone (TSH), free thyroxine (FT4), carcinoembryonic antigen (CEA), CA-125, prostate-specific antigen (PSA), HBs-Ab and Insulin. The RIA-MAT 280 system which adopted the principle of IRMA is used for TSH, FT4, CEA, CA-125 and PSA. TECAN automated dispensing equipment and GAMMA-10 is used to measure insulin test. For the test of HBs-Ab, HAMILTON automated dispensing equipment and Cobra Gamma ray measuring instrument are used. Separate reagent, customized calibrator and quality control materials are used in this experiment. Results 1. TSH [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [14.8 / 4.4 / 3.7 / 0.0 ] C-2(middle concentration) [10.1 / 4.2 / 3.7 / 0.0] 2. FT4 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [10.0 / 4.2 / 3.9 / 0.0] C-2(high concentration) [9.6 / 3.3 / 3.1 / 0.0 ] 3. CA-125 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 4.3 / 4.3 / 0.3] C-2(high concentration) [6.5 / 3.5 / 4.3 / 0.4] 4. CEA [%diffrence Max / Mean / median] (P-value by t-test > 0.05) C-1(low concentration) [9.8 / 4.2 / 3.0 / 0.0] C-2(middle concentration) [8.7 / 3.7 / 2.3 / 0.3] 5. PSA [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [15.4 / 7.6 / 8.2 / 0.0] C-2(middle concentration) [8.8 / 4.5 / 4.8 / 0.9] 6. HBs-Ab [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 3.7 / 2.7 / 0.2] C-2(high concentration) [8.9 / 4.1 / 3.6 / 0.3] 7. Insulin [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [8.7 / 3.1 / 2.4 / 0.9] C-2(high concentration) [8.3 / 3.2 / 1.5 / 0.1] In some low concentration measurements, the percent difference is found above 10 to nearly 15 percent in result of target value calculated at a lower concentration. In addition, when the value is measured after Standard level 6, which is the highest value of reagents in the dispensing sequence, the result would have been affected by a hook effect. Overall, there was no significant difference in lot change of quality control material (p-value>0.05). Conclusion Variations between reagent lots are not large in immunoradiometric assays. It is likely that this is due to the selection of items that have relatively high detection rate in the immunoradiometric method and several remeasurements. In most test results, the difference was less than 10 percent, which was within the standard range. TSH control level 1 and PSA control level 1, which have low concentration target value, exceeded 10 percent more than twice, but it did not result in a value that was near 20 percent. As a result, it is required to perform a longer period of observation for more homogenized average results and to obtain laboratory-specific acceptance criteria for each item. Also, it is advised to study observations considering various variables.

Development of Measurement Scale for Korean Scaling Fear-1.0 and Related Factors (한국형 스켈링공포(KSF 1.0)의 측정도구 개발 및 관련요인)

  • Cho, Myung-Sook;Lee, Sung-Kook
    • Journal of dental hygiene science
    • /
    • v.9 no.3
    • /
    • pp.327-338
    • /
    • 2009
  • This study was to develop an instrument for multidimensional measurement of Korean scaling fear (KSF)-1.0 and analyze related factors. A sample of 720 subjects(scaling patients and community people) was studied in Daegu city from November in 2008 to March in 2009. Authors first conceptualized the KSF, item generation, item reduction, and questionnaire formatting were performed in the stage of the development. Item descriptive, missing%, item internal consistency, and item discriminant validity were analyzed in the item-level, also descriptive, floor and ceiling effect were analyzed in the scale-level. Cronbach's alpha, test-retest, inter-dimension correlations, and factor analysis were performed to evaluate the validity and reliability in the new instrument. Confirmative factor analysis was did to evaluate the fit of model. The results for item-level and scale-level were acceptable except item discriminant validity. The reliability for 0.92~0.96 of corelation coefficient range(Cronbach's alpha 0.96~0.98) was high in the test-retest, and there was no significant difference in paired t-test. Item internal consistency(range of pearson corelation coefficient 0.39~0.95) was also high. The result of explanatory factor analysis was the same as the intended dimension structure, also confirmatory factor analysis results revealed that the dimensional structure model were fined well in the evaluation of model fit($x^2$= 1245.66, df=146, p=0.0000; GFI=0.85; AGFI=0.80; RMSEA=0.10). Factors related to KSF by multiple regression were gender($\beta$=0.28, p=0.0004) and teeth brush method($\beta$=-0.15, p=0.0053) in scaling patients, also gender($\beta$=0.25, p=0.0002), educational level($\beta$=0.14, p=0.0155), teeth brush method($\beta$=-0.09, p=0.0229) and time of daily work out($\beta$=-0.10, p=0.0055) were significantly associated with KSF in no scaling group. In conclusion, The results of this study reveal that the new developed measurement scale was reliable and val id instrument for measuring the KSF in dental hygiene patients and community people. We recommend that further research should develop more the instrument for the Korean scaling fear.

  • PDF

A Study on a Korean-Translated Version of the Pediatric Volitional Questionnaire (PVQ) (Pediatric Volitional Questionnaire의 국내적용을 위한 번역연구)

  • Ra, Dae-Yeop;Chang, Ki-Yeon;Kong, Myung-Ja;Lee, Sun-Wook
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.16 no.3
    • /
    • pp.34-49
    • /
    • 2018
  • Objective : This study aimed to examine the psychometric properties of Korean version of Pediatric Volitional Questionnaire (PVQ-K) using classical test theory. Methods : For the translation of Pediatric Volitional Questionnaire (PVQ), as recommended in the literature, four-stage translation method was used. For the psychometric properties of Korean version of the Pediatric Volitional Questionnaire (PVQ-K), internal consistency reliability, content validity, and construct validity of the test using the known groups method and convergent and divergent methods were examined. For the recruitment of participants, a convenience sampling method is used. Participants of this study were 10 children with neuro-developmental disabilities hospitalized two different rehabilitations center and 10 children with typical development living in Daejeon, South Korea. All 20 participants were in aged from two to five years. Results : In terms of the content validity index, it was over 0.78, confirmed by nine experts of children development. PVQ-K successfully discriminated the scores of children with typical development from those with neurodevelopmental disabilities (p < .05). It is found that there is significant correlations between achievement stage of PVQ-K and the Korean Developmental Screening Test for Infants & Children (K-DTS)(.652 ~ .799 for subcategory, .706 for total scale). The internal consistency was .944 (Cronbach's ${\alpha}$). In qualitative content analysis, it was examined that how Korean children behave and respond in the environment, and how children's volition was strengthened or weakened by the environment. Conclusion : The results propose that PVQ-K can be a useful occupation-focused measure. This study recommend further study on PVQ-K with larger samples combined with the item-response theory approach.

On decrease program of Radioactive Wastewater and Sewages in High Dose Radioiodine Therapy Ward (고용량 방사성옥소 치료병실의 오.폐수 저감화를 위한 연구)

  • Ryu, Jae-Kwang;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.19-26
    • /
    • 2008
  • Purpose: In general, We discharged radioactive wastewater and sewages less than $8.1{\times}10^{-13}$ Ci/ml in a exclusive water-purifier tank. Our hospital operating three exclusive water-purifier tank for radioactive wastewater and sewages of 60 tons capacity respectively. In order to meet the criteria it need a enough decay more than 125 days per each exclusive tank. However, recently we fell into the serious situation that decay period was decreased remarkably, owing to the wastewater amount increased rapidly by enlarge the therapy ward. For that reason, in this article, I'd like to say the way that reducing of radioactive wastewater and sewages rationally. Materials and Methods: From January, 2006 to October, four hundred and two cases were analyzed. They were all hospitalized during 3 days and 2 nights. We calculated the average amount of water used (include toilet water used, shower water used, washstand water used, $\cdots$), each exclusive water-purifier tank's decay period, as well as try to search the increased factors about water-purifier tank inflow flux by re-analysis of the procedure of radioisotope therapy step by step. Results: We could increase each exclusive water-purifier tank's decay period from 84 days to 130 days through the improvement about following cause: (1) Improvement of conventional toilet stool for excessive water waste $\rightarrow$ Replacement of water saving style toilet stool (2) Prevention of unnecessary shower and wash (3) Stop the diuretics taking during hospitalization (4) Analysis of relationship between water intakes and residual dose of body (5) Education about outside toilet utilization before the administration (6) Changed each water-purifier tank's maximum level from85% to 90% Conclusion: The originality of our efforts are not only software but hardware performance improvements. Incidentally the side of software's are change of therapy procedures and protocols, the side of hardware's are replacement of water saving style toilet stool and change of each water-purifier tank's maximum level. Thus even if a long lapse of time, problem such as return to the former conditions may not happen. Besides, We expect that our trials become a new reasonable model in similar situation.

  • PDF