• Title/Summary/Keyword: 스펙트럼 크기

Search Result 525, Processing Time 0.032 seconds

Application of Bispectral Analysis to Estimate Nonlinear Acoustic Parameter (음향 비선형 파라미터의 추정을 위한 바이스펙트럼 해석법의 적용)

  • Kim, K.C.;Jhang, K.Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.2
    • /
    • pp.85-92
    • /
    • 1999
  • The fact that material degradation can be evaluated by measuring nonlinear acoustic effect has been proposed by previous studies. The most conventional method to measure nonlinear acoustic effect is to measure the absolute magnitude of fundamental and $2^{nd}$ order harmonic frequency component in the propagated ultrasonic wave. For this aim, power spectral analysis technique has been used widely. However, the power spectral analysis has fatal disadvantage that the gaussian additive noise superimposed in the wave signal remains in the power spectrum domain. Moreover, the magnitude of $2^{nd}$ order harmonic frequency component generated by nonlinear effect is so small that it may be suppressed by the noise remained in the power spectrum. In order to overcome this problem, this paper proposes an alternative method using bispectrum analysis, which can reduce the effect of addictive gaussian noise and. the nonlinear parameter can be obtained more stably. Simulations showed that the proposed method can obtain the value of nonlinear parameter near to the true value in the case of low SNR signal. Also, in order to confirm the usefulness of our method in actual case, we compared the nonlinear parameter obtained by using both of power spectral and bispectral analysis for several specimen intentionally degraded by fatigue load.

  • PDF

A Study of the Construction in order to 24/25 I-NRZI Modulator Designs for DVCR (DVCR용 24/25 I-NRZI 변조기의 설계를 위한 구조 고찰)

  • Park, Jong-Jin;Kook, Il-Ho;Kim, Eun-Won;Cho, Won-Kyung
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.37 no.1
    • /
    • pp.35-41
    • /
    • 2000
  • This paper considers the consturction of 24/25 I-NRZI (Interleaved - Non Return to Zero Inverse) modulator designs for DVCR (Digital Video Cassette Recorder), and size of validity bit in order to store the amplitude value of square-wave and the standard data ( sine and cosine coefficients) at ROM Table that to acceptable the spectrum standard. The validity bit size of the standard data and the amplitude value of square-wave that to store at ROM Table are affected the size of pilot signal on the output spectrum, and the hardware size of modulator. At the designable 24/25 I-NRZI modulator, we simulated using random pattern (F0,F1,F2) that to verification the output data of the spectrum. Moreover, the resultant of the spectrum analysis, at the optimizing value, is 0.065 on the amplitude value of square-wave, and 3bit on the size of bit in order to store the standared data at ROM Table. In order to verify the hardware of designable 24/25 I-NRZI modulator, we perform to modeling of C-language firstly, and coding to Verilog HDL (Cadence Verilog XL) and synthesized using Synopsys (Library "Samsung KG75") tool as a base of spectrum results. In a foundation of this result, we are considered the size of hardware. In this paper, a considerable 24/25 I-NRZI modulator designable less than 10,000 gates as that is improved consturction as regards the path method of pre-coder etc, and able to application digital camcorders as now practical use.

  • PDF

Noise Characteristic Analysis of X-Ray Fluorescence Spectrum (형광 X-선 스펙트럼의 잡음 특징 분석)

  • Lee, Jae-Hwan;Chon, Sun-Il;Yang, Sang-Hoon;Park, Dong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2298-2304
    • /
    • 2012
  • X-ray fluorescence spectrum analysis method can be applied in many areas, including concentration analysis of RoHS elements and heavy metals etc. and we can get analysis results in a relatively short time. Because X-ray fluorescence spectrum has noises and several artifacts that lowers the accuracy of the analysis. This paper analyzes the characteristics of the noise of the X-ray fluorescence spectrum to increase the accuracy of analysis. X-ray fluorescence spectrum have the characteristics of shot noise (Poisson noise), so the noise size is relatively large in the small signal portion and the noise the size is relatively small in the large part of the signal. Existing methods of analysis and to remove noises is a method for general purposes algorithm. Since these algorithm does not reflect these noise characteristics, we get distorted analysis result. We can design efficient noise remove algorithm based on the accurate noise analysis method, and we expect high accuracy results of the elemental concentration analysis result.

2.4kbps Speech Coding Algorithm Using the Sinusoidal Model (정현파 모델을 이용한 2.4kbps 음성부호화 알고리즘)

  • 백성기;배건성
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.3A
    • /
    • pp.196-204
    • /
    • 2002
  • The Sinusoidal Transform Coding(STC) is a vocoding scheme based on a sinusoidal model of a speech signal. The low bit-rate speech coding based on sinusoidal model is a method that models and synthesizes speech with fundamental frequency and its harmonic elements, spectral envelope and phase in the frequency region. In this paper, we propose the 2.4kbps low-rate speech coding algorithm using the sinusoidal model of a speech signal. In the proposed coder, the pitch frequency is estimated by choosing the frequency that makes least mean squared error between synthetic speech with all spectrum peaks and speech synthesized with chosen frequency and its harmonics. The spectral envelope is estimated using SEEVOC(Spectral Envelope Estimation VOCoder) algorithm and the discrete all-pole model. The phase information is obtained using the time of pitch pulse occurrence, i.e., the onset time, as well as the phase of the vocal tract system. Experimental results show that the synthetic speech preserves both the formant and phase information of the original speech very well. The performance of the coder has been evaluated in terms of the MOS test based on informal listening tests, and it achieved over the MOS score of 3.1.

Suppression of side lobe using distance weight in spectrum of channel signal in medical ultrasound imaging system (의료용 초음파 영상 시스템에서 채널신호의 스펙트럼에서 거리 가중치를 이용한 부엽의 억제)

  • Yu Rim Lee;Mok Kun Jeong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.3
    • /
    • pp.203-213
    • /
    • 2023
  • In medical ultrasound imaging systems, Side lobes may appear if signals outside the imaging point are not completely removed during receive focusing. If the time signal of the side lobe overlaps with the time signal (main lobe) from the image point, it is difficult to completely remove it using filter processing in the time domain. However, In the receive focusing process, when time-channel signals are Fourier-transformed, the main lobe and side lobe signals are spatially separated in the spectral domain. Therefore, the side lobes can be suppressed by multiplying the image with magnitude weights, which are determined by the magnitudes of the main and side lobes calculated in the spectral domain. In addition, when the main lobe and the side lobe spectrum are adjacent, the distance weight was applied based on the distance between them. In a 5 MHz ultrasound imaging system using a 64-channel linear transducer, point reflector and speckle images with cysts of various brightness were synthesized and weights were applied to the ultrasound image. Using computer simulations, we confirmed that the side lobes were greatly reduced without affecting the spatial resolution in the point reflector image, and the contrast was significantly improved in the cyst image with computer simulations.

Analysis of Doppler Spectra in an Airborne Radar (항공기용 레이다에서의 도플러 스펙트럼 분석)

  • Lee, Jong-Gil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.628-631
    • /
    • 2008
  • For the remote sensing purpose, radar systems extract the target information, such as the magnitude of reflectivity and the velocity from the spectrum analysis of return echoes through the Doppler filter bank. This conventional spectrum estimation method, FFT(Fast fourier Transform) is widely used in most radar systems. However, the frequency resolution of return echoes can be seriously degraded in fast moving targets because of the short acquisition time. Since the high Doppler frequency resolution is important in the detection and tracking of fast moving targets, it can cause very unsatisfactory results. Therefore, in this paper, the parameter spectrum estimation method called AR(Autoregressive) spectrum estimation, is investigated to overcome these problems.

  • PDF

Estimating the Thickness Errors in Vertical-Cavity Surface-Emitting Laser Structures from Optical Reflection spectra (반사 스펙트럼을 이용한 VCSEL 에피층의 두께 오차 평가)

  • 김남길;김상배
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.8
    • /
    • pp.572-579
    • /
    • 2003
  • By comparing the measured optical reflection spectra with calculated one by the transfer-matrix method (TMM) in epitaxial wafers for vertical-cavity surface-emitting lasers (VCSELs), we have estimated the systematic thickness errors in a simple and nondestructive way. The experimentally confirmed technique is based on the finding that the shape of the reflection spectra depends mainly on a newly defined single parameter, the effective error in the n-mirror layers, and the thickness error in the active cavity simply shifts the Fabry-Perot resonance wavelength. Also shown is that the proposed method is reliable when the relative standard deviation of the random thickness errors is less than 0.005. Because reflection spectra are routinely measured, we can easily estimate the thickness errors nondestructively with high spatial resolution.

A Study on Diagnosis of Alzheimer's Disease using Raman Spectra from Platelet (혈소판 라만 스펙트럼을 이용한 알츠하이머병 진단에 관한 연구)

  • Park, Aa-Rron;Heo, Gi-Su;Baek, Seong-Joon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.4
    • /
    • pp.40-46
    • /
    • 2010
  • In this paper, we use the Raman spectra measured from platelet to the diagnosis of Alzheimer's disease(AD). The Raman spectra used in the experiments were preprocessed with the following method and then fed into the classifier. The first step of the preprocessing is a simple smoothing followed by background elimination to the original spectra to make it easy to measure the intensity of the peaks. The last step of the preprocessing was peak alignment with the reference peak. After the inspection of the preprocessed spectra, we found that proportion of two peak intensity at 743 and 757 $cm^{-1}$ and peak intensity at 1658 $cm^{-1}$ are the most discriminative features. Then we apply mapstd method for normalization. The method returned data with means to 0 and deviation to 1. With these two features, the classification result involving 278 spectra showed about 95.5% true classification in case of MLP(multi-layer perceptron). It means that the Raman spectra measured from platelet would be effectively used to the diagnosis of Alzheimer's disease.

Fuzzy Classifier and Bispectrum for Invariant 2-D Shape Recognition (2차원 불변 영상 인식을 위한 퍼지 분류기와 바이스펙트럼)

  • 한수환;우영운
    • Journal of Korea Multimedia Society
    • /
    • v.3 no.3
    • /
    • pp.241-252
    • /
    • 2000
  • In this paper, a translation, rotation and scale invariant system for the recognition of closed 2-D images using the bispectrum of a contour sequence and a weighted fuzzy classifier is derived and compared with the recognition process using one of the competitive neural algorithm, called a LVQ( Loaming Vector Quantization). The bispectrum based on third order cumulants is applied to the contour sequences of an image to extract fifteen feature vectors for each planar image. These bispectral feature vectors, which are invariant to shape translation, rotation and scale transformation, can be used to the represent two-dimensional planar images and are fed into a weighted fuzzy classifier. The experimental processes with eight different shapes of aircraft images are presented to illustrate a relatively high performance of the proposed recognition system.

  • PDF

The characteristics of terahertz electromagnetic pulses by electrical and optical parameters. (전기적 광학적 변화가 테라헤르츠 전자기 펄스의 모양에 미치는 영향)

  • 전태인
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.6
    • /
    • pp.503-506
    • /
    • 2001
  • When DC voltages from 5 V up to 90 V are applied to a transmitter chip excited by an ultrafast lacer beam, the terahertz electromagnetic pulses and their spectra are changed. The spectrum shifts to the high frequency range when the high DC voltage is applied to the chip. At that time, the signal-to-noise ratio is increased from 250: 1 to 10,000: 1. The spectrum can expand up to 4 THz by optimal realignment of the THz system. Also, two terahertz electromagnetic pulses are generated from a receiver chip when the laser detection beam is reflected to the back side of the chip.

  • PDF