• Title/Summary/Keyword: 소방장비

Search Result 152, Processing Time 0.032 seconds

A Study on Firefighter and Police Officer's Perception about the Arson Cause Investigation (소방공무원과 경찰공무원의 방화원인 조사에 대한 인식에 관한 연구)

  • Ko, Gi-Bong;Lee, Si-Young;Chae, Jin
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.25-32
    • /
    • 2010
  • This research derived the perception with, and their remedies, in our country's fire cause investigation system by conducting survey on the working-level officials responsible for fire cause investigation in the fire stations and police stations. The results of the survey showed the necessity of establishing departments exclusively responsible for fire statistics management, broad area fire cause investigation task force, fire appraisal organizations besides National Institute of Scientific Investigation, standards for retaining fire investigation equipment, ways of improving technical education system, and improving the system for those who are specialized in arson (fire) cause investigation.

Comparison Analysis of Ready to Use Time Depending on The Type of Public Fire Hydrant of Fire-fighting Water Facility (소방용수시설의 공설소화전 종류에 따른 사용 준비시간 비교분석)

  • Jeon, Jai-In;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.4
    • /
    • pp.87-92
    • /
    • 2019
  • The purpose of this study is to investigate the preparation time of fire-fighting water for public fire hydrants and ground, underground fire hydrants. The equipment preparation time for stage 1 was 20.50 seconds for ground type and 24.67 seconds for underground type. The reason for this difference in preparation time is that an underground fire hydrant requires additional standpipes to connect to the main conduit of Paru and the underground hydrant, which open the manhole cover. Water tank Maintenance joint with water hose male coupling of the second stage was similar to that of the ground type of 48.50 seconds and underground water tipe of 49.00 seconds. This is because the operation of connecting the fire hose to the maintenance tank of the water tank car is the same. In the third stage, the water pipe connection was 43 seconds for ground type and 174.33 seconds for underground type. The reason why the time for connecting the water pipe to the fire hydrant is large difference is that the underground fire hydrant is opened by opening the manhole cover, After connecting the stand pipe to the fire hydrant, the additional process of connecting the water pipe to the stand pipe is required, which is considered to have greatly increased the time required. The opening of Water Control Valve and spindle Valve in the fourth stage was 66.50 seconds for the ground type and 78.83 seconds for the underground type. This difference is due to the fact that the spindle of the ground fire hydrant is located on the main body and can be easily opened, but the underground type is located next to the main body under the manhole and requires additional time to connect the opening equipment.

Quantitative Evaluation of Forest Fire Suppression Equipments as the Extinguishing Distance (진화거리에 따른 산불 진화 장비의 정량화 평가)

  • Kim, Jeong-Hun;Kim, Jang-Huan;Kim, Kyong-Ha;Lee, Byung-Doo;Shin, Jae-Youn
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.426-429
    • /
    • 2011
  • 산불 발생 시 진화를 위해 사용되는 주력 지상 진화장비 중 동력펌프 2종과 진화 차량을 대상으로 수원지로부터 발화 지점까지 진화거리에 따른 주요 성능을 측정하였다. 성능 측정은 분당 토출량, 토출 최대압력, 수평 분사거리, 수직 분사거리의 4개 항목이었으며, 노즐의 종류에 따른 영향을 동시에 고려하였다. 산불 진화 시 적정 거리를 측정한 결과 소형펌프의 경우 600m, 중형펌프의 경우 800~1000m 정도인 것으로 나타났다. 또한 분당 토출량은 3가지 펌프 모두 50m에서 1000m로 연결할 경우 52~62% 감소가 일어나며, 최대 토출압력은 26~30% 상승되어 부하 발생시 고압호스의 파손 우려도 있는 것을 알 수 있었다. 실험을 통해 소형펌프의 경우는 주 산불진화에 적합하지 않으며, 중형펌프의 경우 고압호스의 성능에 따라서 1000m이상의 거리에서도 사용이 가능할 것으로 사료된다.

  • PDF

An Experimental Study on the Warehouse Mock-up Fire Test (창고 모델 실물화재 특성에 대한 실험적 연구)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.47-54
    • /
    • 2010
  • This study is analyze the damage of warehouse fire accident be made through the fire characteristic database of combustibles and real scale fire test of warehouse mock-up. Combustibles fire tests are carried out for database using RCT (Room Corner Tester) to predict fire growth the goods. A mockup ($3m{\times}3m{\times}2.4m$) of clothes warehouse was built and real scale fire test by LSC (Large Scale Calorimeter) base on the fire characteristic DB. The mock-up of clothes warehouse is made of two type sandwich panels (Glass wool, EPS foam sandwich panel). As a mock-up test result, test 1 (Glass wool sandwich panel) and test 2 (EPS foam sandwich panel) indicating fire growth such as 5 MW, 11 MW of maximum HRR (Heat Release Rate).

The Sewol Ferry Disaster and Fire-service Environment Changes (세월호사고와 소방서비스환경변화)

  • Kim, Jin-Dong;Cha, Jong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.321-328
    • /
    • 2017
  • The effects of the Sewol ferry disaster have infiltrated into various fields, such as politics, the economy, and social fields in Korea, and the population's consciousness of the importance of safety has been strengthened by the disaster. The purpose of, this study is to empirically verify whether there has been any change in the fire service environment following the Sewol ferry disaster. Such a change would be expected to have produced a change in the consciousness of the government about safety and increased the level of support. This study sets out five research hypotheses and verifies their adoption. The years studied are those before and after the accident occurred, viz. 2013 and 2015, respectively, and the main statistical technique is the t-test. The main results of this study are as follows. First, there was no significant difference in the fire-service demand between the two years. Second, the fire-service budget showed a significant difference between the two years. Third, the regional resources facilities tax showed a significant difference between the two years. Fourth, the fire-service budget considering the fire-service demand showed no statistically significant difference. Fifth, the fire service-demand considering (the number of) fire-fighters was significantly different in the rescue and emergency medical services between the two years. Sixth, the fire service-demand considering fire-equipment showed no significant difference between the two years.

Problem and Improvement Plan of Existing Fire Examination and Investigation System (현행 화재조사 및 수사체계의 문제점과 개선방안)

  • Kim, Hyung-Doo
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.37-50
    • /
    • 2007
  • A primary task of fire department is maintaining public safety, system maintenance and welfare improvement by protecting life, body and property of a people through prevent and extinguish of the fire in emergency. Rescue part of those affairs has supported by the people but affairs related to the fire examination and investigation could not get it. Although fire examination is a very important part of fire department administration, it has been understood indifferently due to lack of awareness and concern. There are no scientific fire examination because of lacking education study and the whole responsibility capacity about it. There are many things have to be improved at fire examination and investigation system in Korea. Especially, establishment of the whole responsibility post is urgent through assuring professionals to improve accuracy of fire examination and investigation. Equipment which can do scientific fire examination and investigation have to be fully furnished. Efficiency of fire examination and investigation has to be increased through improving law related to fire examination and investigation, giving rescuers investigation right. Through this, it systematically have to be good for fire prevent.

Using AHP to Develop a Rehabilitation Room Management Model for Fire Officers at Disaster Sites (재난현장 소방공무원의 회복실 운영모델 개발)

  • Yim, Dong-Kyun;Chae, Jin
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.115-124
    • /
    • 2020
  • The purpose of this study was to provide an operational model of the rehabilitation room for fire officers at disaster sites to improve the safety and resilience of fire officers. Therefore, we analyzed the operation related elements of the rehabilitation room-such as overseas rehabilitation room operation cases and previous studies- and managed different factors including, but not limited to, management and human resources, equipment and facility, and accessibility and convenience factors; afterward, the relative importance and importance of sub-layers in each field were measured. The priority of items for the operation of the rehabilitation room for fire officers at disaster sites was elucidated; after expert analysis, it was found that human resources were the most crucial factor. Finally, it was found that, in descending order, accessibility and convenience, administrative, equipment, and facility factors were also essential. Based on this, we proposed a rehabilitation room operation guideline for disaster sites.

A Improvement Plan for Fire Fighting Activity of Rack- Type Warehouse Based on Case Study and Field Interview (사례분석과 현장인터뷰를 통한 적층형 대형창고 소방활동 개선방안 연구)

  • Kim, Woon Hyung;Seo, Dong Hun;Ham, Eun Gu
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.1
    • /
    • pp.67-75
    • /
    • 2019
  • Purpose: The purpose of this study is to suggest a systematic improvement plan for strengthening fire fighting ability of domestic rack- type warehouse buildings. Method: A fire case of small warehouse with sandwich panel structure and four design review of large warehouse with fire endurance structure were analyzed. Also, interviewed a group of 11 fire fighters who had 20 years field experience. Results: A provision of mobile equipment for initial fire fighting, accessibility of more than three sides, installation of internal entrance windows, proper placement of outdoor fire fighting equipment, image processing of fire site informations, and provide more incentives on the field commander are main factors of improvement plan. Conclusion: Effective standard operation procedures (SOP) and safety standards should be established and applied for each stage of the dispatch and on-site response considering the fire characteristics and risk factors of each warehouse by scale.

Subjectivity Study on Decision Making Elements for Firefighting of Firefighters: An Investigation Utilizing Q Methodology (소방관의 화재대응의사결정요인에 관한 주관성 연구: Q방법론을 활용한 조사를 중심으로)

  • Junghoon Kim;Seung Hoon Ryu;Dongkyu Lee
    • Knowledge Management Research
    • /
    • v.24 no.4
    • /
    • pp.23-42
    • /
    • 2023
  • This study originated from recognition of importance of firefighters' decision-making in fire response, coupled with existing gap in research. By utilizing Q-methodology, the study aimed to categorize firefighters' subjectivity in fire response decision-making. Through this categorization, the study sought to highlight insights into the current technological and data limitations, as well as potential directions for future R&D in the field of firefighting. The findings of the study revealed that firefighters' subjectivity could be classified into three factors: "emphasis on direct information related to rescue," "emphasis on information related to the target property," and "emphasis on information related to command and coordination." The study theoretically confirmed that the subjectivity of firefighters' decision-making in fire response is partially influenced by their experiences and job. Additionally, the study's significance lay in its approach of collecting specific decision-making factors in fire response, moving beyond general theoretical models. Furthermore, from a policy perspective, the typification of decision-making factors contributed to connecting the identified data-based administrative needs from prior studies. Insights from the study emphasized the importance of leveraging on-site experience in Korea to aid decision-making, calling for the development of equipment and data collection methods that can rapidly and accurately assess on-site conditions.

Influence of the Nozzle Contraction Angles of Gaseous Extinguishing Systems on Discharge Noise (가스계 소화시스템 노즐 수축각이 방출소음에 미치는 영향)

  • Kim, Yo-Hwan;Yoo, Han-Sol;Hwang, In-Ju;Kim, Youn-Jea
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.77-82
    • /
    • 2019
  • Fire extinguishing systems are essential equipment in all indoor facilities to address unexpected fire scenarios, and appropriate fire extinguishing agent should be used depending on the place and object to protect. Among these, gaseous fire-extinguishing systems are used to protect electronic equipment. Therefore, inert gases that do not undergo chemical reactions are used mainly in those systems. On the other hand, recently, owing to the high integration of electronic equipment, there are some cases, in which large noise generated from gaseous systems damage the electronic equipment. In this study, numerical analysis of the discharge noise with various nozzle contraction angles was carried out to improve the gas fire extinguishing system. Numerical analysis was carried out using ANSYS FLUENT ver 18.1. The causes of the noise were elucidated using the swirl distribution. The noise level of the modified model was reduced by approximately 6 dB compared to the reference model, which is similar to the result of a previous study, confirming the validity of the method.