• Title/Summary/Keyword: 소방도로

Search Result 308, Processing Time 0.02 seconds

Results of a Round-Robin Test for the Draft International Standard on FT-IR Gas Analysis of Fire Effluents from a Cone Calorimeter (콘칼로리미터 연소가스 FT-IR 분석을 위한 국제표준 초안의 비교시험 결과분석)

  • Choi, Jung-Min;Park, Kye-Won;Jeong, Jae-Gun
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.1-8
    • /
    • 2019
  • The international standard for FT-IR gas analysis of fire effluents in ISO 5660-1 cone calorimeter has been being developed in ISO TC 92. A comparison of the round-robin test of WD 21397 was conducted with six participating laboratories in 2018. The test specimens were PMMA, rigid PU foam board, and PVC flooring. The measurement quantities were the time-to-ignition, peak heat release rate, total heat release, and effective heat of combustion for a cone calorimeter test and peak gas concentration, gas generation, and gas yield for FT-IR gas analysis. No outliers were identified. For the cone calorimeter quantities, the repeatability and reproducibility were 1.5% and 9.8%, respectively. For FT-IR gas analysis, the repeatability and reproducibility was 12.9% and 27.9%, respectively.

A Study on the Effect of Inflammable Materials on the Control Characteristics of Thermal and Smoke Fluid of Water Curtain System (가연성 물질에 따른 워터커튼 시스템의 열 및 연기유동 제어특성에 관한 연구)

  • You, Woo-Jun;Nam, Jun-Seok;Kim, Dong-Joon;Lee, Jeong-Kyoon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.53-58
    • /
    • 2012
  • In this study fire control characteristics for inflammable materials of water curtain system are experimentally analyzed. Heat release rate for pinewood and gasoline was calculated using Room Corner Tester (RCT) and fire test apparatus for water curtain system is manufactured. Nozzles (180 degree of injection angle, 8.2 mm of orifice diameter) are installed at the nearby ceiling of place at 5 m distance from fire originate and temperature profile as well as transmission are obtained from the fire experiment of pinewood and gasoline in the water curtain system. Based on the results, parameters of engineering importance for fire control characteristics of water curtain system such as generation of high temperature smoke and thermal phenomena of fluid flow by injection nozzle are identified.

The Case Analysis through Fire Simulation FDS and Evacuation Simulation Pathfinder (화재 시뮬레이션 FDS와 피난시뮬레이션 Pathfinder 사례분석)

  • Kim, Jong Yoon;Jeon, Yong Han
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.10 no.6
    • /
    • pp.253-260
    • /
    • 2015
  • In this study, using the FDS as the fire simulation and evacuation simulations of the Pathfinder, set the main control room of the building to the fire point fire safety assessment studies were carried out. At first the quantitative result such as distribution of visibility as time passing, distribution of temperature, distribution of CO density produced results using fire-simulation and evacuation-simulation was carried out based on the result that produced the final safety evaluation result as being calculated of evacuation time. As the risk increased with the distribution of visibility at the result of fire-simulation, evacuation-simulation was carried out using the result. Finally the result was made 127.9 sec that everyone could evacuate. The numerical results are analyzed in case of the places in the building required safe egress time for safety a as the analysis to be no more than available safe egress time was analyzed to be secured. The results of this safety evaluation represent that more smooth evacuation safety performance can be secured by linking the event of fire firefighting equipment as a result of simulating the worst conditions.

  • PDF

A Study of Carbon NCF Prepreg Manufacturing and Stacking Pattern Optimal Design Using Structure Analysis (CFRP 적용을 위한 Carbon NCF Prepreg 제작 및 구조해석을 활용한 적층패턴 최적설계 연구)

  • Kim, S.;Shin, H.C.;Ha, Sung Kyu
    • Composites Research
    • /
    • v.33 no.1
    • /
    • pp.13-18
    • /
    • 2020
  • Recently, the fire rescue truck in problem proceed research it for the fast works action and for pass the small road. So we were research for weight reduction. In this study, the (NO. 5) fifth boom of the fire rescue truck have 288 mm(W) × 299 mm(D) × 3,691 mm(L) with a maximum load of 876 kg and the thickness of 3 mm of the Steel Boom. This changing of Steel (STRENX960) to CFRP was weave Carbon Fiber NCF (±45°, 2axis) and then it make the NCF Prepreg. This process was designed based on structural analysis, the effects of NCF Prepreg (±45°) on torsion were identified, and the optimal design was made with Stacking Pattern (b). Stack patterns were optimized for levels equal or higher than existing Steel Boom and CFRP Boom stacked in the UD direction, and finally, the lightening effect on weight of approximately 49.6% of the steel was identified.

The Study on Surface Fire Spread in Fuel Bed (Fuel Bed에서의 지표화 확산에 관한 연구)

  • Kim, Jeong-Hun;Kim, Eung-Sik;Kim, Dong-Hyun;Kim, Jang-Whan
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.22-27
    • /
    • 2014
  • In this study a Fuel bed where surface fire spreads through is made to measure the data such as the flame height, radiation, spread rate and temperature distribution of Fuel bed. As experimental variables species of trees, wind velocities and slop are chosen. Fallen leaves of Quercus Variabilis (Q.V.) and Pinus Densiflora (P.D.) are used as fuel. Wind velocity is controlled by simply designed wind turnnel from 1 to 5 m/s. Slope of fuel bed is changed from $0^{\circ}$ to $30^{\circ}$. For the measurements of temperature distribution and spread rate total 35 of K-type 1.6 mm thermocouples are positioned as a lattice design. Radiant heat flow meters are used besides video camera and thermovision camera.

A Research of Grain Size Analysis of Particulate Matter in Fire Effluent (연소 생성물 내 입자상 물질의 입도에 관한 연구)

  • Kim, Sung-Soo;Choi, Seo-Yeon;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.8-12
    • /
    • 2014
  • Interior finishing materials using noncombustible were regulated by the building codes to prevent the spread of fire and protect occupants. The average deed of stopping time of experimental mouse exposing combustion gas were measured by KS F 2271 gas toxicity test. At that time, The average deed of stopping time under 9 minutes were judged a inconsistence. This experiment method has limit to find out a cause of toxicity effect factor. In this study, particle size analysis were performed for investigate a major factor.

Measurement Bias of Heat Flux Gauge based on Calibration Constant supported by Manufacturer (제조사 보정상수에 기인한 열유속계의 측정 오차)

  • Kim, Sung-Chan;Hamins, Anthony
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.1-6
    • /
    • 2018
  • As a preliminary study to quantify the measurement uncertainty of the Schmidt-Boelter type heat flux gauge, the present study has been conducted to evaluate the measurement error due to the calibration constant supported by manufacturer. Calibrations of heat flux gauges are performed at NIST Fire Research Division using a calibration facility with heat source of a 2000 W halogen-tungsten filament lamp and the calibration constant is obtained by comparing the response of the reference and a standard heat flux gauge at the same irradiance conditions. Calibration for heat flux gauges made by three different manufacturers is compared with their factory calibration constant. Relative error due to fluctuation of output signal from heat flux gauges does not exceed 1% of the mean value and the relative error between calibration of this study and factory calibration constant ranged from 1.5% to 14.3%. The present study shows that a continuous and periodic calibration is necessary for accurate heat flux measurement.

An Analysis of 119 Emergency Calls: Focused on Conversation Time and Contents (119 구급 신고 분석: 대화 시간 및 내용을 중심으로)

  • Jang, Kyungho;Kang, Kyunghee
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.103-109
    • /
    • 2018
  • The call-takers in the 119 General Situation Room are playing important roles in recognizing the first crisis situation such as fire, rescue, and emergency, and in starting up the response system. In particular, with regard to the emergency calls, the prompt and accurate surveillance can determine the patient's life as well as the prognosis. Based on April 8-December 31, 2014 Prehospital Care Reports in a metropolitan city, we analyzed the conversation turns and the conversation time between the agent and the caller, and the time of the conversation structure and sequence according to the reception routes and the severity of symptoms. The conversation analysis between the agent and the caller will be useful for the development and improvement of the action manual in the future.

Risk Screening of a BTX Plant Using FEDI Method (화재폭발손실지수법을 이용한 BTX 공장의 위험선별)

  • Kim Yong-Ha;Kim In-Tae;Kim In-Won;Kim Ku-Hwoi;Yoon En-Sup
    • Fire Science and Engineering
    • /
    • v.19 no.1 s.57
    • /
    • pp.20-28
    • /
    • 2005
  • Major petrochemical companies in the USA and the EU map out the strategies step-by-step hazard evaluation for the efficient risk management. They adopted the risk screening methods, such as Dow fire & explosion index, as a preliminary phase to execute detailed evaluation such as QRA (Quantitative Risk Assessment). In this study, The FEDI (Fire & Explosion Damage Index), which a kind of risk screening method proposed by Khan and Abbasi, was applied to the BTX plant in Korea. We showed that the FEDI can be effectively used to classify the hazard potential by comparison of the result from the FEDI and the result from QRA. And we showed that the characteristics and the quantities of chemical are the factors which have a largest effect on fire and explosion by executing relative sensitivity analysis of the FEDI. In conclusion, if the FEDI was applied as a preliminary phase of HAZOP, more efficient hazard evaluation can be possible.

Study of Post-Fire Safe-Shutdown Analysis of a CANDU Main Control Room based on NEI 00-01 Methodology (NEI 방법론을 적용한 중수로 주제어실의 화재안전정지분석에 관한 연구)

  • Kim, In-Hwan;Lim, Heok-Soon;Bae, Yeon-Kyoung
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.20-26
    • /
    • 2016
  • When the fire takes place in Nuclear Powr Plants(NPPs), the reactor should achieve and maintain safe shut-down conditions and minimize the radioactive material released to the environment. The U.S. Nuclear Regulatory Commission (NRC) has issued numerous generic communications related to fire protection over the past 20 years, after it issued its requirements in the Fire Protection Rule set forth in Title 10, Section 50.48 of the Code of Federal Regulations (10 CFR 50.48) and Appendix R to the 10 CFR 50. The and Nuclear Energy Institute (NEI) has developed a Methodology for Risk Informed Fire Safe-Shutdown Analysis, which is related to the Deterministic Method for Multiple Spurious Operations solutions. The aim of this study was to identify, achieve, and maintain Post-Fire Safe-Shutdown of the Main Control Room (MCR) of the CANDU reactor, even though one train of the multiple Safety Structures, Systems, and Components (SCCs) fail by the technical specification and analysis method.