• Title/Summary/Keyword: 선형 개발

Search Result 3,518, Processing Time 0.036 seconds

A Study on the Frictional Resistance Chracteristics of Pressurized Soil Nailing Using Rapid Setting Cement (초속경 시멘트를 사용한 가압식 쏘일네일링의 주입시간에 따른 마찰저항특성에 관한 연구)

  • Lee, Arum;Shin, Eunchul;Lee, Chulhee;Rim, Yongkwan
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.1-10
    • /
    • 2018
  • Although the soil nailing method is generally used as a gravity grouting, the development and application of pressurized grouting method has recently increased to address the problem of joint generation and filling due to grouting. Pressurized grouting of the soil nailing method is generally used in combination with ordinary portland cement and water. In the field, the cement is mixed with the rapid setting cement to reduce curing time because ordinary portland cement takes more than 10 days to satisfy the required strength. In this study, uniaxial compression tests and laboratory tests were carried out to confirm the efficiency of the grouting material according to the mixing ratio of rapid setting cement. The mixing ratio of 30% grouting satisfies the required strength within 7 days and satisfies the optimum gel time. As a result of the laboratory test with granite weathered soil, the reinforcing effect was confirmed to be 1.5 times as compared with the gravity type at an injection time of 10 seconds and a strain of 15%. The friction resistance increases linearly with the increase of the injection time, but it is confirmed that the friction resistance decreases due to the hydraulic fracturing effect at the injection time exceeding the limit injection pressure. Numerical analysis was performed to compare the stability of slopes not reinforced with slopes reinforced with gravity and pressurized soil nailing.

The Interdigitated-Type Capacitive Humidity Sensor Using the Thermoset Polyimide (열경화성 폴리이미드를 이용한 빗살전극형 정전용량형 습도센서)

  • Hong, Soung-Wook;Kim, Young-Min;Yoon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.604-609
    • /
    • 2019
  • In this study, we fabricated a capacitive humidity sensor with interdigitated (IDT) electrodes using a thermosetting polyimide as a humidifying material. First, the number of electrodes, thickness, and spacing of the polyimide film were optimized, and a mask was designed and fabricated. The sensor was fabricated on a silicon substrate using semiconductor processing equipment. The area of the sensor was $1.56{\times}1.66mm^2$, and the width of the electrode and the gap between the electrodes were each $3{\mu}m$. The number of electrodes was 166, and the length of an electrode was 1.294 mm for the sensitivity of the sensor. The sensor was then packaged on a PCB for measurement. The sensor was inserted into a chamber environment with a temperature of $25^{\circ}C$ and connected to an LCR meter to measure the change in capacitance at relative humidity (RH) of 20% to 90%, 1 V, and 20 kHz. The results showed a sensitivity of 26fF/%RH, linearity of < ${\pm}2%RH$, and hysteresis of < ${\pm}2.5%RH$.

The Effects of Supervisor's Abusive Behavior on Job Exhaustion and Organizational Effectiveness of Nurses. (상사의 비인격적 행동이 간호사의 직무소진과 조직유효성에 미치는 영향)

  • Kang, Cheon-Kook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.438-446
    • /
    • 2019
  • This study examined the effects of non - personality behavior of supervisors on the job exhaustion and organizational effectiveness of nurses. A survey in the form of a questionnaire was completed by 250 nurses working at three general hospitals located in Seoul and Gyeonggi from September 20 to October 31, 2014. The collected data were analyzed by frequency analysis, factor analysis, correlation, and linear regression analysis using the SPSS program. The results of the analysis were as follows. First, the effects of the non-personality behavior of supervisors on the job exhaustion of nurses were statistically significant. Second, the effects of non-personality behavior of supervisors on the organizational effectiveness of nurses were statistically significant in job satisfaction, organizational commitment, and organizational citizenship behavior. Third, the effects of job exhaustion on organizational effectiveness of nurses was statistically significant for job satisfaction, job exhaustion, and organizational citizenship behavior. Because the non-personality behavior of a supervisor can have a negative effect on the exhaustion of a nurse's job and the organizational effectiveness, there should be a wide range of human resources and effective task allocations in a hospital to reduce job burnout and increase job satisfaction. In addition, it is necessary for the boss to develop desirable leadership education, appropriate modeling, and reduce their negative influence in the workplace.

Development and Application of Two-Dimensional Numerical Tank using Desingularized Indirect Boundary Integral Equation Method (비특이화 간접경계적분방정식방법을 이용한 2차원 수치수조 개발 및 적용)

  • Oh, Seunghoon;Cho, Seok-kyu;Jung, Dongho;Sung, Hong Gun
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.447-457
    • /
    • 2018
  • In this study, a two-dimensional fully nonlinear transient wave numerical tank was developed using a desingularized indirect boundary integral equation method. The desingularized indirect boundary integral equation method is simpler and faster than the conventional boundary element method because special treatment is not required to compute the boundary integral. Numerical simulations were carried out in the time domain using the fourth order Runge-Kutta method. A mixed Eulerian-Lagrangian approach was adapted to reconstruct the free surface at each time step. A numerical damping zone was used to minimize the reflective wave in the downstream region. The interpolating method of a Gaussian radial basis function-type artificial neural network was used to calculate the gradient of the free surface elevation without element connectivity. The desingularized indirect boundary integral equation using an isolated point source and radial basis function has no need for information about the element connectivity and is a meshless method that is numerically more flexible. In order to validate the accuracy of the numerical wave tank based on the desingularized indirect boundary integral equation method and meshless technique, several numerical simulations were carried out. First, a comparison with numerical results according to the type of desingularized source was carried out and confirmed that continuous line sources can be replaced by simply isolated sources. In addition, a propagation simulation of a $2^{nd}$-order Stokes wave was carried out and compared with an analytical solution. Finally, simulations of propagating waves in shallow water and propagating waves over a submerged bar were also carried and compared with published data.

Analysis of Correlation between Marine Traffic Congestion and Waterway Risk based on IWRAP Mk2 (해상교통혼잡도와 IWRAP Mk2 기반의 항로 위험도 연관성 분석에 관한 연구)

  • Lee, Euijong;Lee, Yun-sok
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.5
    • /
    • pp.527-534
    • /
    • 2019
  • Several types of mathematical analysis methods are used for port waterway risk assessment based on marine traffic volume. In Korea, a marine traffic congestion model that standardizes the size of the vessels passing through the port waterway is applied to evaluate the risk of the waterway. For example, when marine traffic congestion is high, risk situations such as collisions are likely to occur. However, a scientific review is required to determine if there is a correlation between high density of maritime traffic and a high risk of waterway incidents. In this study, IWRAP Mk2(IALA official recommendation evaluation model) and a marine traffic congestion model were used to analyze the correlation between port waterway risk and marine traffic congestion in the same area. As a result, the linear function of R2 was calculated as 0.943 and it was determined to be significant. The Pearson correlation coefficient was calculated as 0.971, indicating a strong positive correlation. It was confirmed that the port waterway risk and the marine traffic congestion have a strong correlation due to the influence of the common input variables of each model. It is expected that these results will be used in the development of advanced models for the prediction of port waterway risk assessment.

Development of Capacitive Type Humidity Sensor using Polyimide as Sensing Layer (폴리이미드를 감지층으로 이용한 정전용량형 습도센서 개발)

  • Hong, Soung-Wook;Kim, Young-Min;Yoon, Young-Chul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.4
    • /
    • pp.366-372
    • /
    • 2019
  • In this paper, we fabricated a capacitive humidity sensor with an IDT(Interdigitated) electrode using commercial polyimide containing fluorine, and its properties were measured and analyzed. First, in order to analyze the composition of commercial polyimide, EDS analysis was performed after patterning process on a silicon wafer. The area of the humidity sensor was $1.56{\times}1.66mm^2$, and the width of the electrode and the gap between the electrodes were $3{\mu}m$ each. The number of electrodes was 166 and the length of the electrode was 1.294mm for the sensitivity of the sensor. The fabricated sensor showed that the sensitivity was 24 fF/%RH, linearity <${\pm}2.5%RH$ and hysteresis <${\pm}4%RH$. As a result of measuring the capacitance value according to the frequency change, the capacitance vlaue decreased with increasing frequency. Capacitance deviations with 10kHz and 100kHz were measured as 0.3pF on average.

Convergence Study on the Influence of Personality and Stress on College Life Adaptation in Nursing College Students (간호대학생의 인성 및 스트레스가 대학생활 적응에 미치는 영향에 관한 융합연구)

  • Lim, Jae-Ran;Kim, Soon-Young
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.10
    • /
    • pp.301-308
    • /
    • 2019
  • The purpose of this study is to understand the relationship between personality, stress and college adjustment of nursing college students and to identify the factors influencing college adjustment. The data collected from December 14, 2017 to December 19, 2017, and the questionnaire from 193 nursing students in D City. The data were analyzed by t-test, one-way ANOVA and Scheffe's test, Pearson's correlation and multiple regression analysis. The mean scores of major satisfaction, was $6.32{\pm}2.03$, personality was $3.76{\pm}.43$, stress was $1.57{\pm}.37$, and college adjustment was $3.30{\pm}.65$. There were positive correlations between college adjustment and major satisfaction(r = .41, p <.001), as well as between personality (r = .60, p <.001). The significant factors influencing the college adjustment were number of consultation, major satisfaction and personality, which explained 49% of the variance in the college adjustment. Based on these findings, programs that develop personality are necessary for college nursing students in order to promote college adjustment.

The Effect of the Image of Nurses and the Major Satisfaction on the Nursing Professionalism among Nursing students in University (간호 대학생이 느끼는 간호사 이미지와 전공만족도가 간호전문직관에 미치는 영향)

  • Jo, HaEun;Ahn, YuHa;Ryu, SuMin;Lim, JaeYoung;Kim, HeyKyoung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.1008-1017
    • /
    • 2019
  • The purpose of this study was to investigate the effect of the image of nurses and major satisfaction on the nursing professionalism among nursing students in university and to presents basic data for making positive nursing professionalism. A survey was held to the university students in Seoul and Chungcheong cities from May 30 to June 4, 2019. 184 copies were in the final analysis for data analysis, t-test, ANOVA, Pearson's Correlation Coefficient and Multiple regression was used. As a result, the factors of affecting on the nursing professionalism were followed by character, motivation for nursing, future prospects of nursing, image of nurses and major satisfaction. The multiple regression explanatory power was 63.6percent of the total changes in nursing professionalism. Therefore, this study could be used as a basic data for the development of education programs to create positive image through positive self-image and enhance learning satisfaction in order to increase nursing students' professionalism.

Application of Google Search Queries for Predicting the Unemployment Rate for Koreans in Their 30s and 40s (한국 30~40대 실업률 예측을 위한 구글 검색 정보의 활용)

  • Jung, Jae Un;Hwang, Jinho
    • Journal of Digital Convergence
    • /
    • v.17 no.9
    • /
    • pp.135-145
    • /
    • 2019
  • Prolonged recession has caused the youth unemployment rate in Korea to remain at a high level of approximately 10% for years. Recently, the number of unemployed Koreans in their 30s and 40s has shown an upward trend. To expand the government's employment promotion and unemployment benefits from youth-centered policies to diverse age groups, including people in their 30s and 40s, prediction models for different age groups are required. Thus, we aimed to develop unemployment prediction models for specific age groups (30s and 40s) using available unemployment rates provided by Statistics Korea and Google search queries related to them. We first estimated multiple linear regressions (Model 1) using seasonal autoregressive integrated moving average approach with relevant unemployment rates. Then, we introduced Google search queries to obtain improved models (Model 2). For both groups, consequently, Model 2 additionally using web queries outperformed Model 1 during training and predictive periods. This result indicates that a web search query is still significant to improve the unemployment predictive models for Koreans. For practical application, this study needs to be furthered but will contribute to obtaining age-wise unemployment predictions.

Development of Variable Stiffness Soft Robot Hand for Improving Gripping Performance (그리핑 성능 향상을 위한 가변강성 소프트 로봇 핸드 개발)

  • Ham, KiBeom;Jeon, JongKyun;Park, Yong-Jai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.47-53
    • /
    • 2018
  • Various types of robotic arms are being used for industrial purposes, particularly with the small production of multi-products, and the importance of the gripper, which can be used in industrial fields, is increasing. This study evaluated a variable stiffness mechanism gripper that can change the stiffness using the nonlinearity of a flexible material. A prototype of the gripper was fabricated and examined to confirm the change in stiffness. The previous gripper was unable to grip objects in some situations with three variable stiffness mechanism. In addition, these mechanisms were not balanced and rarely rotated when the object was gripped. Therefore, a new type of gripper was needed to solve this problem. Inspired by the movements of the human palm and Venus Flytrap, a new type of a variable stiffness soft robot hand was designed. The possibility of grasping could be increased by interlocking the palm folding mechanism by pulling the tendon attached to the variable stiffness mechanism. The soft robotic hand was used to grasp objects of various shapes and weights more stably than the previous variable stiffness mechanism gripper. This new variable stiffness soft robot hand can be used selectively depending on the application and environment to be used.