• Title/Summary/Keyword: 샘플 통계

Search Result 207, Processing Time 0.025 seconds

Comparison of fatigue fracture strength by fixture diameter of mini implants (미니 임플란트 직경에 따른 피로파절강도의 비교 연구)

  • Heo, Yu-Ri;Son, Mee-Kyoung;Kim, Hee-Jung;Choe, Han-Cheol;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.156-161
    • /
    • 2012
  • Purpose: This study was conducted to obtain difference in fracture strength according to the diameter of one-body O-ring-type of mini implant fixture, to determine the resistance of mini implant to masticatory pressure, and to examine whether overdenture using O-ring type mini implant is clinically usable to maxillary and mandibular edentulous patients. Materials and methods: For this study, 13 mm long one body O-ring-type mini implants of different diameters (2.0 mm, 2.5 mm and 3.0 mm) (Dentis, Daegu, Korea) were prepared, 5 for each diameter. The sample was placed at $30^{\circ}$ from the horizontal surface on the universal testing machine, and off-axis loading was applied until permanent deformation occurred and the load was taken as maximum compressive strength. The mean value of the 5 samples was calculated, and the compressive strength of implant fixture was compared according to diameter. In addition, we prepared 3 samples for each diameter, and applied loading equal to 80%, 60% and 40% of the compressive strength until fracture occurred. Then, we measured the cycle number on fracture and analyzed fatigue fracture for each diameter. Additionally, we measured the cycle number on fracture that occurred when a load of 43 N, which is the average masticatory force of complete denture, was applied. The difference on compressive strength between each group was tested statistically using one-way ANOVA test. Results: Compressive strength according to the diameter of mini implant was $101.5{\pm}14.6N$, $149{\pm}6.1N$ and $276.0{\pm}13.4N$, respectively, for diameters 2.0 mm, 2.5 mm and 3.0 mm. In the results of fatigue fracture test at 43 N, fracture did not occur until $2{\times}10^6$ cycles at diameter 2.0 mm, and until $5{\times}10^6$ cycles at 2.5 mm and 3.0 mm. Conclusion: Compressive strength increased significantly with increasing diameter of mini implant. In the results of fatigue fracture test conducted under the average masticatory force of complete denture, fracture did not occur at any of the three diameters. All of the three diameters are usable for supporting overdenture in maxillary and mandibular edentulous patients, but considering that the highest masticatory force of complete denture is 157 N, caution should be used in case diameter 2.0 mm or 2.5 mm is used.

A Study on the Influence of Information Security on Consumer's Preference of Android and iOS based Smartphone (정보보안이 안드로이드와 iOS 기반 스마트폰 소비자 선호에 미치는 영향)

  • Park, Jong-jin;Choi, Min-kyong;Ahn, Jong-chang
    • Journal of Internet Computing and Services
    • /
    • v.18 no.1
    • /
    • pp.105-119
    • /
    • 2017
  • Smartphone users hit over eighty-five percentage of Korean populations and personal private items and various information are stored in each user's smartphone. There are so many cases to propagate malicious codes or spywares for the purpose of catching illegally these kinds of information and earning pecuniary gains. Thus, need of information security is outstanding for using smartphone but also user's security perception is important. In this paper, we investigate about how information security affects smartphone operating system choices by users. For statistical analysis, the online survey with questionnaires for users of smartphones is conducted and effective 218 subjects are collected. We test hypotheses via communalities analysis using factor analysis, reliability analysis, independent sample t-test, and linear regression analysis by IBM SPSS statistical package. As a result, it is found that hardware environment influences on perceived ease of use. Brand power affects both perceived usefulness and perceived ease of use and degree of personal risk-accepting influences on perception of smartphone spy-ware risk. In addition, it is found that perceived usefulness, perceived ease of use, degree of personal risk-accepting, and spy-ware risk of smartphone influence significantly on intention to purchase smartphone. However, results of independent sample t-test for each operating system users of Android or iOS do not present statistically significant differences among two OS user groups. In addition, each result of OS user group testing for hypotheses is different from the results of total sample testing. These results can give important suggestions to organizations and managers related to smartphone ecology and contribute to the sphere of information systems (IS) study through a new perspective.

Analysis of Labelling Efficiency According to Differences of Rotating Time in a Asan Medical Center (AMC) RBC Labelling Method (서울아산병원의 적혈구 표지 방법에서 교반 시간 차이에 따른 표지 효율의 분석)

  • Chung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Shim, Dong-Oh;Lee, Yeong-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.90-93
    • /
    • 2010
  • Purpose: In our nuclear medicine department, we suggested AMC RBC labeling method improved by modifying a part of existing modified in-vitro method to raise the efficiency of $^{99m}Tc$-RBC labeling. However, it needs to be more additional time and efforts than existing modified in-vitro method because the AMC RBC labeling method has to carry out the centrifugal separation process for 3~5 minutes. Therefore, in this study, we conducted researches to aim to maintain stable labeling effects and supplement a problem about additional time by reducing rotating time when labeling $^{99m}Tc$-RBC. Materials and Methods: This research has been conducted the object of 30 patients who examined study using $^{99m}Tc$-RBC and agreed to this research at our hospital from May 2009 to September 2009. We made 4 blood samples which consisted of ACD 1 cc along with 5 cc blood from each patient and used the AMC RBC labeling method. At this moment, each labeling efficiency was calculated by different rotating time 5 min, 10 min, 15 min, and 20 min and then we compared differences. Results: As a result, When comparing the $^{99m}Tc$-RBC labeling method efficiency by using the AMC RBC labeling method which differents from rotating time, each labeling efficiency were $92.3{\pm}5.0%$ in 5 min, $95.9{\pm}5.0%$ in 10 min, $97.4{\pm}4.9%$ in 15 min and $97.7{\pm}4.8%$ in 20 min. We analyzed differences of the labeling efficiency from change of rotating time by using an one-way ANOVA and verified that in Duncan method. There was relatively efficiency low in 5min rotating time and no statistically significant change in over. Conclusions: When comparing a existing method, the AMC RBC labeling method which goes through the centrifugal separation process again offers more favorable condition to combine RBC with $^{99m}TcO4^-$ by eliminating an plasma ingredient. When using the modified in-vitro method, we have almost 20 min to rotate to acquire stable labeling efficiency. But, when using the AMC RBC labeling method, we acquire labeling efficiency well what we want within only 10 min to rotate. Decrease of rotating time can complement the AMC RBC labeling method which goes through the centrifugal separation process again and also provide more rapid study such as G-I bleeding study due to fast labeling.

  • PDF

The Effects of Organization Characteristics and Relationship Characteristics on Relational Performance: Focused on Mediating Effects of the Dimensions of Trust and Commitment (조직특성과 관계특성이 관계성과에 미치는 영향: 신뢰 차원과 결속 차원의 매개효과를 중심으로)

  • Sung, Min;Oh, Se-Jo
    • Journal of Distribution Research
    • /
    • v.12 no.1
    • /
    • pp.1-31
    • /
    • 2007
  • While trust and commitment are core mediating variables for the purpose of maintaining the long-term relationship, in the context of the characteristics of company and the relationship performance of its members, there have been limited studies which explore as to how each of the dimensions has affects differently. The basic purpose of this study is to examine the relationship between an automobile manufacturer and its agencies. The main purpose of this study is to examine how each different dimension of trust and commitment on the automobile manufacturer has different mediating effects between the characteristics of company(organization characteristics, relationship characteristics) and relationship performance perceived by its agents. Another purpose is to investigate the mechanism by which the relationship performance of the agencies is improved. An empirical study surveying 115 sales office managers at a leading automobile manufacturer in Korea was conducted. An analysis of the collected data indicates that while the characteristics of company have a positive influence on the agencies' relational performance through the mediating role of both trust of benevolence and commitment, agencies' trust of their headquarter's benevolence has a different influence on the dimensions of commitment. Finally, the authors discussed some theoretical contributions and managerial implications. And then, they presented limitations of this study and the future research directions.

  • PDF

Development and Validation of Real-time PCR to Determine Branchiostegus japonicus and B. albus Species Based on Mitochondrial DNA (Real-time PCR 분석법을 이용한 옥돔과 옥두어의 종 판별법 개발)

  • Chung, In Young;Seo, Yong Bae;Yang, Ji-Young;Kim, Gun-Do
    • Journal of Life Science
    • /
    • v.27 no.11
    • /
    • pp.1331-1339
    • /
    • 2017
  • DNA barcoding is the identification of a species based on the DNA sequence of a fragment of the cytochrome C oxidase subunit I (COI) gene in the mitochondrial genome. It is widely applied to assist with the sustainable development of fishery-product resources and the protection of fish biodiversity. This study attempted to verify horse-head fish (Branchiostegus japonicus) and fake horse-head fish (Branchiostegus albus) species, which are commonly consumed in Korea. For the validation of the two species, a real-time PCR method was developed based on the species' mitochondrial DNA genome. Inter-species variations in mitochondrial DNA were observed in a bioinformatics analysis of the mitochondrial genomic DNA sequences of the two species. Some highly conserved regions and a few other regions were identified in the mitochondrial COI of the species. In order to test whether variations in the sequences were definitive, primers that targeted the varied regions of COI were designed and applied to amplify the DNA using the real-time PCR system. Threshold-cycle (Ct) range results confirmed that the Ct ranges of the real-time PCR were identical to the expected species of origin. Efficiency, specificity and cross-reactivity assays showed statistically significant differences between the average Ct of B. japonicus DNA ($21.85{\pm}3.599$) and the average Ct of B. albus DNA ($33.49{\pm}1.183$) for confirming B. japonicus. The assays also showed statistically significant differences between the average Ct of B. albus DNA ($22.49{\pm}0.908$) and the average Ct of B. japonicus DNA ($33.93{\pm}0.479$) for confirming B. albus. The methodology was validated by using ten commercial samples. The genomic DNA-based molecular technique that used the real-time PCR was a reliable method for the taxonomic classification of animal tissues.

Comparison of the Diagnostic Performance of $^{14}C$-urea Breath Test According to Counting Method for the Diagnosis of Helicobacter pylori Infection (Helicobacter pylori 감염 진단 시 $^{14}C$-요소호기검사의 계수측정 방법에 따른 진단성능 비교)

  • Kim, Min-Woo;Lim, Seok-Tae;Lee, Seung-Ok;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.21-25
    • /
    • 2005
  • Purpose: $^{14}C$-urea breath test (UBT) is a non-invasive and reliable method for the diagnosis of Helicobacter pylori (HP) infection. In this study, we evaluated the diagnostic performance of a new and rapid $^{14}C$-UBT (Heliprobe method), which was equipped with $Geiger-M\ddot{u}ller$ counter and compared the results with those obtained by using the conventional method. Materials and Methods: Forty-nine patients with dyspepsia underwent gastroduodenoscopy and $^{14}C$-UBT. A 37 KBq $^{14}C$-urea capsule was administered to patients and breath samples were collected. In Heliprobe method, patients exhaled into a Hellprobe BreathCard for 10 min. And then the activities of the BreathCard were countered using Heliprobe analyzer. In the conventional method, results were countered using liquid scintillation counter. During gastroduodenoscopy, 18 of 49 patients were underwent biopsies. According to these histologic results, we evaluated the diagnostic performance of two different methods and compared them. Also we evaluated the concordant and disconcordant rates between them. Results: In all 49 patients, concordant rate of both conventional and Heliprobe methods was 98% (48/49) and the discordant rate was 2% (1/49). Thirteen of 18 patients to whom biopsies were applied, were found to be HP positive on histologic results. And both Heliprobe method and conventional method classified 13 of 13 HP-positive patients and 5 of 5 HP-negative patients correctly (sensitivity 100%, specificity 100%, accuracy 100%). Conclusion: The Heliprobe method demonstrated the same diagnostic performance compared with the conventional method and was a simpler and more rapid technique.

A Comparative Study on Quantifying Uncertainty of Vitamin A Determination in Infant Formula by HPLC (HPLC에 의한 조제분유 중 비타민 A 함량 분석의 측정불확도 비교산정)

  • Lee, Hong-Min;Kwak, Byung-Man;Ahn, Jang-Hyuk;Jeon, Tae-Hong
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.152-159
    • /
    • 2008
  • The purpose of this study was to determine the accurate quantification of vitamin A in infant formula by comparing two different standard stock solutions as well as various sample weights using high performance liquid chromatography. The sources of uncertainty in measurement, such as sample weight, final smaple vloume, and the instrumental results, were identified and used as parameters to determine the combined standard uncertainty based on GUM(guide to the expression of uncertainty in measurement) and the Draft EURACHEM/CITAC Guide. The uncertainty components in measuring were identified as standard weight, purity, molecular weight, dilution of the standard solution, calibration curve, recovery, reproducibility, sample weight, and final sample volume. Each uncertainty component was evaluated for type A and type B and included to calculate the combined uncertainty. The analytical results and combined standard uncertainties of vitamin A according to the two different methods of stock solution preparation were 627 ${\pm}$ 33 ${\mu}$g R.E./100 g for 1,000 mg/L of stock solution, and 627 ${\pm}$ 49 ${\mu}$g R.E./100 g for 100 mg/L of stock solution. The analytical results and combined standard uncertainties of vitamin A according to the various sample weighs were 622 ${\pm}$ 48 ${\mu}$g R.E./100 g, 627 ${\pm}$ 33 ${\mu}$g R.E./100 g, and 491 ${\pm}$ 23 ${\mu}$g R.E./100 g for 1 g, 2 g, and 5 g of sampling, respectively. These data indicate that the preparation method of standard stock solution and the smaple amount were main sources of uncertainty in the analysis results for vitamin A. Preparing 1,000 mg/L of stock solution for standard material sampling rather than 100 mg, and sampling not more than 2 g of infant formula, would be effective for reducing differences in the results as well as uncertainty.

An Analysis of Epidemiological Investigation Reports Regarding to Pathogenic E. coli Outbreaks in Korea from 2009 to 2010 (최근 2년간(2009-2010) 우리나라 병원성 대장균 식중독 역학조사 보고서 분석)

  • Lee, Jong-Kyung;Park, In-Hee;Yoon, Kisun;Kim, Hyun Jung;Cho, Joon-Il;Lee, Soon-Ho;Hwang, In-Gyun
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.4
    • /
    • pp.366-374
    • /
    • 2012
  • Recently pathogenic E. coli is one of the main foodborne pathogens resulting in many patients in Korea. To understand the characteristics of pathogenic E. coli outbreaks in Korea, the epidemiological investigation reports of pathogenic E. coli outbreak in 2009 (41 reports) and in 2010 (27 reports) were collected in the web site of the Korea Centers for Disease Control and Prevention, reviewed and analysed in this study. The main places of the pathogenic E. coli outbreaks were food catering service area (64.8%) and restaurants (25.0%). The main type of the pathogens were EPEC (44.7%) and ETEC (34.2%). EAEC and EHEC was responsible for 10.5 and 9.2%, respectively. Eight of 68 outbreak cases were caused by more than 2 types of pathogenic E. coli which implicates the complicated contamination pathways of pathogenic E. coli. The incidence rate of pathogenic E. coli was $33.6{\pm}30.5%$ and the main symptoms were diarrhea, stomach ache, nausea, vomiting, and fever etc. The two identified food sources were identified as frozen hamburger pattie and squid-vegetable mixture. To improve the food source identification by epidemiological investigation, food poisoning notification to the agency should not be delayed, whole food items attributed the outbreak should be collected and detection method of the various pathogenic E. coli in food has to be improved. In conclusion, the characteristics between the EHEC outbreaks in the western countries and the EPEC or ETEC outbreaks in Korea needs to be distinguished to prepare food safety management plan. In addition, the development of the trace back system to find the contamination pathway with the improved detection method in food and systemic and cooperative support by the related agencies are necessary.

Clinical Significance of Antibodies Against Platelet HLA Class I in Children with Idiopathic Thrombocytopenic Purpura (소아 특발성 혈소판 감소증에서 항-HLA Class I항체의 임상적 의미)

  • Lee, Hong Jun;Yeom, Jung-Sook;Park, Ji Sook;Park, Eun Sil;Seo, Ji-Hyun;Lim, Jae Young;Park, Chan-Hoo;Woo, Hyang-Ok;Youn, Hee-Shang
    • The Korean Journal of Blood Transfusion
    • /
    • v.24 no.3
    • /
    • pp.233-240
    • /
    • 2013
  • Background: A previous history of transfusion has been known to be associated with production of anti-HLA class I antibodies. However, platelet glycoproteins are the main target of idiopathic thrombocytopenic purpura (ITP). The mechanism of antibody production is known to differ significantly between glycoproteins and anti-HLA class I. The aim of this study was to evaluate the clinical significance of anti-HLA class I antibodies in childhood ITP. Methods: Enrollment for the normal control group targeted 48 people who visited Gyeongsang National University Hospital from 1990 to 2010, and 48 young children with ITP. Anti-glycoproteins and anti-HLA class I antibodies were tested using the Modified Antigen Capture Enzyme-linked immunosorbent assay (MACE) kit. Results: The positive rate of anti-HLA antibodies was significantly different [36/39 (92.3%) vs 29/46 (63%)] [ITP group vs normal control group] (P=0.002). The mean positive S/C ratio of anti-HLA antibodies was also significantly different (3.55 vs 1.51) [ITP group vs normal control group] (P=0.0000). The positive rate of anti-HLA did not differ significantly between the transfused group and the non-transfused group [12/12 (100%) vs 24/27 (88%)] [transfused ITP vs non-transfused ITP]. The mean positive S/C ratio of anti-HLA antibodies did not differ significantly between the transfused ITP group and the non-transfused ITP group (4.30 vs 3.25) [transfused ITP vs non-transfused ITP]. Consecutive testing showed that positive rate and positive S/C ratio of anti-HLA antibodies did not change significantly between sampling times in both groups [transfused ITP vs non-transfused ITP] (P=1.00 and P=0.15). Conclusion: Anti-HLA class I antibodies may be involved in childhood ITP. Transfusion did not affect the course of childhood ITP.

Measurement of Backscattering Coefficients of Rice Canopy Using a Ground Polarimetric Scatterometer System (지상관측 레이다 산란계를 이용한 벼 군락의 후방산란계수 측정)

  • Hong, Jin-Young;Kim, Yi-Hyun;Oh, Yi-Sok;Hong, Suk-Young
    • Korean Journal of Remote Sensing
    • /
    • v.23 no.2
    • /
    • pp.145-152
    • /
    • 2007
  • The polarimetric backscattering coefficients of a wet-land rice field which is an experimental plot belong to National Institute of Agricultural Science and Technology in Suwon are measured using ground-based polarimetric scatterometers at 1.8 and 5.3 GHz throughout a growth year from transplanting period to harvest period (May to October in 2006). The polarimetric scatterometers consist of a vector network analyzer with time-gating function and polarimetric antenna set, and are well calibrated to get VV-, HV-, VH-, HH-polarized backscattering coefficients from the measurements, based on single target calibration technique using a trihedral corner reflector. The polarimetric backscattering coefficients are measured at $30^{\circ},\;40^{\circ},\;50^{\circ}\;and\;60^{\circ}$ with 30 independent samples for each incidence angle at each frequency. In the measurement periods the ground truth data including fresh and dry biomass, plant height, stem density, leaf area, specific leaf area, and moisture contents are also collected for each measurement. The temporal variations of the measured backscattering coefficients as well as the measured plant height, LAI (leaf area index) and biomass are analyzed. Then, the measured polarimetric backscattering coefficients are compared with the rice growth parameters. The measured plant height increases monotonically while the measured LAI increases only till the ripening period and decreases after the ripening period. The measured backscattering coefficientsare fitted with polynomial expressions as functions of growth age, plant LAI and plant height for each polarization, frequency, and incidence angle. As the incidence angle is bigger, correlations of L band signature to the rice growth was higher than that of C band signatures. It is found that the HH-polarized backscattering coefficients are more sensitive than the VV-polarized backscattering coefficients to growth age and other input parameters. It is necessary to divide the data according to the growth period which shows the qualitative changes of growth such as panicale initiation, flowering or heading to derive functions to estimate rice growth.