Journal of the korean academy of Pediatric Dentistry
/
v.32
no.2
/
pp.293-299
/
2005
It is important to reduce chair time and procedure in restorative treatment for children. Composite resin is not only used in esthetic restoration of anterior teeth but also posterior teeth by its improved physical property. The 7th generation dentin bonding system was recently developed in order to simplify three steps which is needed to bond composite resin to tooth surface-etchant, primer, adhesive. We compared shear bond strengths of 4, 5, 6, 7th generations dentin bonding systems. The primary dentin was pretreated with 4, 5, 6, 7th generation dentin bonding systems. Then composite resin was cured to the specimen using molds 2.5mm in diameter and 2mm in height. Thermocycling was performed and shear bond strength was finally measured. The results were as follow; 1. The mean values of shear bond strengths in 5th generation dentin bonding system(group 2) were greater than those of 4, 6, 7th generation dentin bonding system(group 1, 3, 4). The differences were statistically significant. 2. The mean values of shear bond strengths in 4th generation dentin bonding system(group 2) were greater than those of 6, 7th generation dentin bonding system(group 1, 3, 4). But, the differences were not statistically significant. 3. Between the mean values of shear bond strengths in 6, 7th generation dentin bonding system(group 3, 4) were similar.
Journal of the korean academy of Pediatric Dentistry
/
v.28
no.4
/
pp.553-565
/
2001
One-bottle adhesive system was recently developed in order to simplify the clinical skills and save chair time after continuous improvements on dentin bonding agents. To test the shear bond strength of a new "one-bottle adhesive" system to bovine dentin various commercially available one-bottle adhesives(Prime & Bond $2.1^{(R)}$, One Coat $Bond^{(R)}$, Syntac $Sprint^{(R)}$, Single $Bond^{(R)}$) were included for comparison. And we observe the interfacial morphology by scanning electron microscope. The results were as follows; 1. Group II (One Coat $Bond^{(R)}$) showed higher shear bond strength than group I (Prime & Bond $2.1^{(R)}$), group III(Syntac $Sprint^{(R)}$), and group IV(Single $Bond^{(R)}$), but no statistically significant difference was founded between groups(p>.05). 2. Relating reverse-cone shape resin tags were observed in samples of all groups under SEM. We could observed hybrid layer, resin tag and many lateral branches in every group. But, we observed in group III rare lateral branched than other three groups, and discontinuous hybrid layer.
Journal of the korean academy of Pediatric Dentistry
/
v.28
no.2
/
pp.228-237
/
2001
It is well known that glass-ionomer cement and compomer can release fluoride which can inhibit the progression of dental caries. The purposes of this study were to evaluate whether the fluoride from fluoride-containing filling materials can penetrate the dentin bonding adhesive and the dentin bonding adhesive can increase the bond strength of resin-modified glass ionomer. The amount of fluoride release from resin-modified glass ionomer and compomer was measured during 28 days of period and statistically analyzed by t-test. The bond strength of each material with/without dentin bonding adhesive was measured and also statistically analyzed by t-test. The distribution of fluoride from each material into the tooth was explored by electron probe microanalysis system(EPMA). The experimental teeth used were second primary molars about to exfoliate. The amount of fluoride release from each material was diminished by dentin bonding adhesive during 28 days(p<0.05) and the bond strength was not increased by dentin adhesive in resin-modified glass ionomer. The bond strength of group VI was not detectable. The distribution of fluoride from each material into teeth was according to dentino-enamel junction and dispersed into pulp from pulpal floor. The widest distribution was shown in resin-modified glass ionomer cement filled without the application of dentin bonding adhesive.
The purpose of this study was to evaluate the effect of dual bonding technique by comparing microshear bond strength between two different luting methods of resin cement to tooth dentin. Three dentin bonding systems(All-Bond 2, One-Step, Clearfil SE Bond), two temporary cements (Propac, Freegenol) were used in this study. In groups used conventional luting procedure, dentin surfaces were left untreated. In groups used dual bonding technique, three dentin bonding systems were applied to each dentin surface. All specimens were covered with each temporary cement. The temporary cements were removed and each group was treated using one of three different dentin bonding system. A resin cement was applied to the glass cylinder surface and the cylinder was bonded to the dentin surface. Then, micro-shear bond strength test was performed. For the evaluation of the morphology at the resin/dentin interface, SEM examination was also performed. 1. Conventional luting procedure showed higher micro-shear bond strengths than dual boning technique. However, there were no significant differences. 2. Freegenol showed higher micro-shear bond strengths than Propac, but there were no significant differences. 3. In groups used dual bonding technique, SE Bond showed significantly higher micro-shear bond strengths in One-Step and All-Bond 2 (p<0.05), but there was no significant difference between One-Step and All-Bond 2. 4. In SEM observation, with the use of All-Bond 2 and One-Step, very long and numerous resin tags were observed. This study suggests that there were no findings that the dual bonding technique would be better than the conventional luting procedure.
Journal of the korean academy of Pediatric Dentistry
/
v.26
no.4
/
pp.595-607
/
1999
The purpose of this in vitro study was to evaluate the efficacy of self-etching primer which was developed to simplify the bonding procedures by measuring the shear bond strength and observing the interfacial morphology. 90 flat dentinal surfaces were prepared by grinding the buccal and lingual areas of caries-free human deciduous molars. After bonding of composite resin to sample surfaces according to the manufacturer's direction and thermocycling, shear bond strengths were measured using Universal testing machine(Instron). Another groups of specimens were treated by hydrochloric acid to secure the resin only and those tags were evaluated under SEM for their length and forms and the morphology of the bonding sites were also observed. The result as follows. 1. Group III showed higher shear bond strength than group I and II but no statistically significant difference was founded between group I and II(p>.05). 2. Adhesive failure was predominant in group II whereas dentin detachment was the main failure pattern in group I and III. 3. Relating long resin tags of $100-200{\mu}m$ were observed in samples of all groups under SEM. In group I, homogeneously long resin tags were arranged rather tight whereas rather loosely arranged resin tags of various length were found in group II. Lateral branching of resin tags was the characteristic finding observed in group III.
Journal of the korean academy of Pediatric Dentistry
/
v.29
no.1
/
pp.30-37
/
2002
Bacterial microleakage around restorations is considered the principal cause of pulpal inflammation associated with restorations. The rationale for using cavity disinfectant is based on its antimicrobial properties but the cavity disinfectant may leave debris on dentin surfaces. The purpose of this study was to evaluate the effect of 2% chlorhexidine on shear bond strength and microleakage of adhesive restoration. 45 sound bovine teeth were used for the shear bond strength test and 30 for the micorleakage. For the experimental groups, 2% chlorhexidine was applied before the restorations, and was not for the control groups. The result from the this study can be summarized as follows; 1. No significant difference could be found in shear bond strength of each group. 2. No significant difference could be found in microleakage of each group.
Journal of the korean academy of Pediatric Dentistry
/
v.34
no.3
/
pp.420-429
/
2007
The purpose of this study was to compare the micro ensile bond strength to bovine dentin of several adhesives (SM, Scotch $Bond^{TM}$ Multipurpose; SB, $Adper^{TM}$ Single Bond 2; SE, $Clearfil^{(R)}$ SE Bond; AQ, AQ $Bond^{TM}$; TS, $Clearfil^{(R)}$ tri-S Bond). Except SM and SB, they have a simplified one- or two-step application protocols in compare with the dentin adhesives conventional three-step protocols. For the microtensile bond strength test, the labial surfaces of bovine incisors were used. Following exposure of dentin layer, according to their manufacturer's directions, each dentin adhesives were applied and composite resin blocks were constructed. The teeth were sectioned for specimen and tested microtensile bond strength. Also observed the fracture mode of interface. The obtained results were as follows : 1. The microtensile bond strength values ranged from 51.34 to 24.04 MPa on dentin(in decreasing order, SE, SM, SB, AQ and TS). 2. The highest microtensile bond strength was by SE and SM on bovine dentin, and the lowest by AQ and TS. 3. SM, SB and SE showed cohesive failures and adhesive failure but AQ, TS presented almost adhesive failures. In summary, microtensile bond strengths of single-step adhesives (AQ and TS) on bovine dentin were significantly lower than those of multi-step adhesives (SM, SB and SE) (p<0.05).
Journal of the korean academy of Pediatric Dentistry
/
v.27
no.3
/
pp.444-456
/
2000
To test the shear bond strength of a new "one-bottle adhesive" system to primary dentin two commercially available one-bottle adhesives (Prime & Bond NT, Single bond) and conventional three step system(Scotchbond Multi-Purpose Plus) were included for comparison. And We observe the interfacial morphology by scanning electron microscope. 90 primary molar teeth were embedded in acrylic and buccal and lingual surface were polished to 320 grit to create standardized dentin surface for testing. After bonding of composite resin to sample surfaces according to the manufacturer s direction and 1000 times thermocycling in dwell time 30 second, Shear bond strengths of adhesives to dentin were determined using universal testing machine and analyzed by ANOVA test. Another groups of specimens were treated by hydrochloric acid to secure the resin only and those tags were evaluated under SEM for their length and forms and the morphology of the bonding sites were also observed. The result are as follows. 1. Group I(Prime & Bond NT) showed higher shear bond strength than group iI(Single Bond) and III(Scotchbond Multi Purpose Plus) but no statistically significant difference was founded between groups(p>.05). 2. Relating long resin tags of $70-120{\mu}m$ were observed in samples of all groups under SEM. We could observed hybrid layer, resin tag and many lateral branches in every group. But, we observed in group III rare lateral branched than other two group and discontinuous hybrid layer.
The purpose of this study was to evaluate the effect of chlorhexidine (CHX) on microtensile bond strength (${\mu}TBS$) of dentin bonding systems. Dentin collagenolytic and gelatinolytic activities can be suppressed by protease inhibitors, indicating that MMPs (Matrix metalloproteinases) inhibition could be beneficial in the preservation of hybrid layers. Chlorhexidine (CHX) is known as an inhibitor of MMPs activity in vitro. The experiment was proceeded as follows: At first, flat occlusal surfaces were prepared on mid-coronal dentin of extracted third molars. GI (Glass Ionomer) group was treated with dentin conditioner, and then, applied with 2 % CHX. Both SM (Scotchbond Multipurpose) and SB (Single Bond) group were applied with CHX after acid-etched with 37% phosphoric acid. TS (Clearfil Tri-S) group was applied with CHX, and then, with adhesives. Hybrid composite Z-250 and resin-modified glass ionomer Fuji-II LC was built up on experimental dentin surfaces. Half of them were subjected to 10,000 thermocycle, while the others were tested immediately. With the resulting data, statistically two-way ANOVA was performed to assess the ${\mu}TBS$ before and after thermo cycling and the effect of CHX. All statistical tests were carried out at the 95 % level of confidence. The failure mode of the testing samples was observed under a scanning electron microscopy (SEM). Within limited results, the results of this study were as follows; 1. In all experimental groups applied with 2 % chlorhexidine, the microtensile bond strength increased, and thermo cycling decreased the micro tensile bond strength (P > 0.05). 2. Compared to the thermocycling groups without chlorhexidine, those with both thermocycling and chlorhexidine showed higher microtensile bond strength, and there was significant difference especially in GI and TS groups. 3. SEM analysis of failure mode distribution revealed the adhesive failure at hybrid layer in most of the specimen. and the shift of the failure site from bottom to top of the hybrid layer with chlorhexidine groups. 2 % chlorhexidine application after acid-etching proved to preserve the durability of the hybrid layer and microtensile bond strength of dentin bonding systems.
Statement of problem: An incompatibility between the initiator systems of self-curing composite resins and light-curing adhesives was supposed recently. Purpose: The purpose of the study was to evaluate the influence of activators for self/dual bonding on dentin shear bonding strengths. Material and methods: Fifty human molars were divided into 5 groups. A flat dentin surface was created for each tooth. A self-curing composite resin (Luxacore) was bonded with the following adhesives (n = 10); One-Step, Prime&Bond NT, AdheSE, Prime&Bond NT and AdheSE were also used in combination with activators. Shear bond strengths were measured after 24 hours of water storage. The specimens were loaded in shear in the Instron until failure at a 1 mm/min crosshead speed. Data were compared using one-way ANOVA and Tukey HSD test (${\alpha}$= 0.05). Results: The dentin adhesive systems in order of decreasing median bond strength were One-Step > Prime&Bond NT with activator, AdheSE with activator > Prime&Bond NT, AdheSE. Among adhesives, One-Step had the highest bond strength. Prime&Bond NT with activator had higher bond strengths than Prime&Bond NT that was used alone, and so was AdheSE. Conclusion: Shear bond strengths were increased in Prime&Bond NT and AdheSE when these were used with activators comparing used without activators. But using activators was not effective clinically comparing One-Step.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.