• Title/Summary/Keyword: 삽입형 포트

Search Result 21, Processing Time 0.022 seconds

Compared the Causes of Problematic Chemo-Ports According to the Types of Chemo-Ports(Valved, vs. Non-Valved) (Valve포트와 Non-Valved포트 사용에 따른 문제점의 비교 분석)

  • You, In-Gyu;Lim, Cheong-Hwan;Han, Beom-Hee;Jung, Hong-Ryang;Joo, Yeong-Cheol
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.35-41
    • /
    • 2011
  • Total implanted central venous port (TIAP, Chemoport) is widely used in oncology patients because it does not require external dressing and restricts patient activity. Chemoport only requires monthly flushes of heparinized saline to keep the patency of the catheter and probably less prone to infectious complications than tunneled catheter. Despite the extensive use of permanent central venous access in oncology patients, there are only few reports about clinical experience of the Groshong catheter. The purpose of this study is to compare the complication rate between the traditional open-ended (non-valved) chemoports and valved chemoports (Groshong catheter connected to TIAP). During 5 years (Jan 2006 to May 2010), 438 patients received chemoport insertion procedure in our interventional radiology department. Among them 30 patients was referred to our department for problematic chemoports. We compared the cause of problematic chemoports between two types of chemoports (valved, vs. non-valved). Valved chemoports had higher referral rates than non-valved chemoports. When there is a need to insert valved port, different method of insertion and maintenance procedure seems to be necessary. More than 20 ml of flusing with heparinized saline after blood sampling could be a good suggestion. Adequate care of chemoport is essential for long patency. Also following the guideline from the manufacturing company is necessary.

Symmetric Microwave Lens with Uniform Insertion Loss for Broad-band and Wide Beam Steering Coverage (균일한 삽입손실을 갖는 광대역 빔 조향용 대칭형 초고주파 렌즈)

  • 김인선;이광일;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.3
    • /
    • pp.279-287
    • /
    • 2002
  • In this paper, a symmetric microwave lens to steer wide angle and to operate at broad band frequency range for a linear phased array transmitter was designed. To get accurate beam steering performance far a linear phased array transmitter, uniform amplitude transmission characteristics of microwave lens was focused. The measured result for the insertion loss deviation between Input and output ports of microstrip lens with 8 beam ports and 8 array ports was $\pm$3.1 ㏈ over 6~18 ㎓ band, which was very uniform characteristics. Using 8 elements linear array antenna, it was confirmed the radiation beam could be steered over $\pm$60$^{\circ}$ in azimuth. And the measured lens performance data and multi-beam steering pattern were presented.

Current Status of Interval of Heparin Flushing for Maintenance of an Implanted Port in Solid Tumor Patients (고형암 환자의 삽입형 포트 개방성 유지를 위한 헤파린 관류 주기 현황)

  • Kim, Hye Kyung;Choi, So Eun;Lee, Jung Hoon;We, Eun Sook;Joh, Hye Jin;Kim, Kwang Sung
    • Journal of Korean Biological Nursing Science
    • /
    • v.16 no.3
    • /
    • pp.251-257
    • /
    • 2014
  • Purpose: Little is known about appropriate interval periods between the heparin flushing of implanted ports after completion of chemotherapy. The purpose of this study was to describe the current status of interval of heparin flushing for maintenance of an implanted port in solid tumor patients. Methods: We performed a retrospective review of all patients who had undergone implanted port removal in 2012 at the Seoul St. Mary's Hospital. The subjects were 90 patients who, after completion of chemotherapy, retained their ports for extended periods of time. Results: The mean number of flushes of heparin was 4. Compliance with visits for implanted port maintenance varied with the individual, and the mean accession times were in the range between 13 days and 243 days. The overall mean time between flushes was 66 days. One patient showed resistance during flushing. Conclusion: Our results demonstrate that extending the flushing interval to a maximum of 8 weeks remains medically safe. Less frequent heparin flushing of an implanted port decreases medical expenditure and the workload of medical professionals; it also improves the patient's satisfaction.

Measurement of the Noise Parameters of On-Wafer Type DUTs Using 8-Port Network (8-포트회로망을 이용한 온-웨이퍼형 DUT의 잡음파라미터 측정)

  • Lee, Dong-Hyun;Ahmed, Abdule-Rahman;Lee, Sung-Woo;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.8
    • /
    • pp.808-820
    • /
    • 2014
  • In this paper, we fabricated two on-wafer type DUT(Device-Under-Test)s; a 10-dB attenuator and an amplifier using commercially available MMIC and we proposed the measurement method of the noise parameters for the two fabricated DUTs. Since the 10-dB attenuator DUT is a passive device, its noise parameters can be accurately determined when its S-parameters are measured. In the case of the amplifier DUT, its noise parameters are available in the datasheet. Hence, the measured noise parameters using the proposed method can be assessed by comparing with the known noise parameters. The noise parameter measurement method having been presented by the authors requires the S-parameters of the 8-port network used in the measurement and limited to coaxial type DUTs. When on-wafer probes are included in the 8-port network, the 8-port S-parameters requires the measurements with different kinds of connectors. In this paper, we obtained the 8-port S-parameters using the Smart-Cal function in the network analyzer. The measured noise parameters shows about ${\pm}0.2dB$ fluctuations for $NF_{min}$. Other noise parameters with the frequency change show good agreement with the expected results.

Feasibility and Safety of a Technique Intended to Place the Catheter Tip in the Right Atrium without Abutment Against the Cardiac Wall during Implantation of the Totally Implantable Venous Access Port (완전이식형 정맥 접근 포트 삽입 시 카테터 팁을 심벽에 닿지 않고 우심방 내 위치시키는 방법의 타당성과 안전성)

  • Hyejin Park;Tae-Seok Seo;Myung Gyu Song;Woo Jin Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.161-170
    • /
    • 2024
  • Purpose To assess the safety and feasibility of intentionally positioning the catheter tip in the right atrium (RA) without an abutment during implantation of a totally implantable venous access port (TIVAP). Materials and Methods We enrolled 330 patients who had undergone TIVAP implantation between January and December 2016 and postoperative chest CT. The TIVAP was placed using the single-incision technique to access the axillary vein directly from the incision line. To position the catheter tip in the RA without abutment, blood return was checked before cutting. Catheter length and complications were evaluated by retrospectively reviewing medical images and records. Results All patients achieved successful catheter tip positioning without abutment or dysfunction. The median tip position was 15.3 mm distal to the cavoatrial junction (CAJ) on fluoroscopy and 6 mm distal to the CAJ on CT. Catheter tips migrated a median of 10.4 mm cephalically on CT compared to fluoroscopy. Thromboses were detected in the RA and superior vena cava in one patient each. Conclusion Intentional catheter tip positioning in the RA without abutment is a safe and feasible technique with a low incidence of thrombosis and no observed dysfunction.

Development and Effects of Fear-Reduction Program for Malignant Disease Children with Inserting Implanted Port (이식형 포트 삽입 학령전기 아동의 주사공포감소를 위한 프로그램 개발 및 효과)

  • Yang, Kyung-Ah;Chang, Sook;Kim, Il-Ok
    • Korean Parent-Child Health Journal
    • /
    • v.8 no.1
    • /
    • pp.37-48
    • /
    • 2005
  • Purpose: The purpose of this study was to develop a play education program to reduce children's fear of needle insertion to the implanted port, and to assess the effect of this program. Method: The play education program was composed of play education before needle insertion, encouragement during needle insertion, and a present to reward then after needle insertion. Measurement instruments were the Procedure Behavior Check List(PBCL) and Faces Rating Scale(FRS). Results: The first hypothesis, "the PBCL point of children with malignant disease would decrease after play education program", was rejected(before insertion : Z=-0.189, p= .850, during insertion : Z=-0.350. p= .727, after insertion : Z=-0.590, p= .555). The second hypothesis, "the FRS point of children with malignant disease would decrease after play education program education", was rejected(observer 1 : Z=-0.245, p= .806, observer 2 : Z=-0.912, p= .362, self-report : Z=-0.181, p= .856). The third hypothesis, "the Time of needle insertion would decrease after play education program", was rejected(Z=-0.464, p= .642). Conclusion: The effect on fear-reduction of play education program for children with malignant disease inserted implanted port was not significant but continuous education is needed for parents and children.

  • PDF

Prototype Phase Array Antenna using Ferroelectric Phase Shifter (강유전체 위상변위기를 이용한 위상배열 안테나)

  • Moon, Seung-Eon;Ryu, Han-Cheol;Kwak, Min-Hwan;Kim, Young-Tae;Lee, Sang-Seok;Lee, Su-Jae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.127-130
    • /
    • 2003
  • 4-bit 강유전체 위상변위기를 이용하여 10 GHz, 상온에서 작동하는 위상배열 안테나를 설계 및 제작하였다. 이 안테나는 빔 스캔을 위하여 전압에 대한 비선형특성을 보이는 강유전체 Bal-xSrxTiO3 (BST)를 기본으로 하는 위상변위기를 이용하였다. 우리는 펄스레이져 증착법으로 MgO (001) 기판위에 걸맞게 증착된 BST 박막을 일반적인 사진공정과 식각법을 이용하여 동일평판형 전극을 가진 위상변위기를 만들었다. 일반적인 동일평판형 강유전체 위상변위기의 경우 연결 전송선로의 임피던스와의 차이로 인해 반사손실과 이로 인한 부가적인 삽입손실이 발생한다. 이런 손실들을 줄이기 위해 입력과 출력 포트에 임피던스 매칭을 하였다. 이렇게 테이퍼링되어 만들어진 동일평판형 위상변위기는 이전의 구조에 비해 반사 손실과 삽입 손실 값에서 각각 약 10, 2 dB 정도씩의 개선을 보였다. 이 구조로 전송선로의 길이를 길게하여 만든 1-bit 강유전체 위상변위기는 10 GHz, 150 V의 전압변화에서 180도의 차등위상변위를 보였으며 최대 삽입손실과 최대 반사손실은 각각 약 10 dB, 20 dB 이다. 안테나 모듈은 4개의 마이크로스트림 패치 안테나와 4개의 강유전체 위상변위기로 이루어졌는데 10 GHz, 150 V의 전압변화에서 약 15도의 빔 스캔을 확인하였다.

  • PDF

Finite Element Analysis on the Deformation Behavior Safety of a Gas Valve (가스밸브의 변형거동 안전성에 관한 유한요소해석)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.4
    • /
    • pp.70-75
    • /
    • 2017
  • This paper presents the FEM analysis results on the deformation behavior safety of automatic cut-off horizontal and conventional vertical gas valves. Based on the FEM analysis, the primary maximum deformation of $4.4{\mu}m$ was formed on the right end side of a valve body when the internal gas pressure was supplied on the screw port and gas discharge port of an automatic cut-off horizontal gas valve. And the secondary maximum deformation of $2.9{\mu}m$ was formed on the end side of safety valve port. This small deformation of an automatic cut-off horizontal gas valve is strongly related to the balanced design of a horizontal gas valve main body, which is composed of a screw part, gas outlet port, port for a stem and spindle shaft assembly, and safety valve port. But, the primary maximum deformation of 0.076mm was formed on the upper part of a conventional automatic cut-off vertical gas valve when the internal gas pressure was supplied on the screw port and gas discharge port. And the secondary maximum deformation of 0.055mm was formed on the left end side of a gas outlet port. This may effect on the sealing clearance of o-ring that is inserted on the groove of an automatic cut-off unit. Thus, this paper recommends an automatic cut-off horizontal gas valve compared with that of a conventional gas valve for a gas leakage free mechanism of a LPG cylinder valve.

Design and Fabrication of a Narrow-Band Orthomode Transducer for Satellite Communication (위성통신용 협대역 직교모드편파분리기의 설계 및 제작)

  • 장중호;최현철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.6B
    • /
    • pp.1149-1155
    • /
    • 1999
  • This paper presents a narrow-band orthomode transducer(OMT) based on waveguide to waveguide transitions which can separate two linearly polarized orthogonal modes. This operates in the range 120Hz-13GHz frequency band. It consists of two parts, main arm and side arm. Stepped transformers are designed and an inductive post is inserted to improve the characteristics of the transmission loss and isolation. This paper also presents results from fabricated OMT These results show that the transmission loss is less than 1dB and the isolation between the ports for the OMT is above 20dB.

  • PDF

A fully integrated downconverter MMIC for millimeter wave applications (밀리미터파 응용을 위한 완전집적 다운컨버터 MMIC)

  • Jeon, Jang-Hyeon;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.1
    • /
    • pp.99-104
    • /
    • 2013
  • In this paper, we developed a fully integrated downconverter MMIC (monolithic microwave integrated circuit) including Lange coupler and output active balun for millimeter wave applications. Concretely, ${\lambda}$/4 transmission line was added to Lange coupler for size reduction of RF/LO input, and mixed RF/LO signals were applied to gate of the FET of mixer. Active balun was used at output port for a coupling of out-of-phase IF output signals. According to measured results, the proposed downconverter MMIC showed good RF performances. For example, the downconverter MMIC showed an LO leakage power of -25 dBc at IF output port, and a RF-LO isolation of 18 dB. Therefore, off-chip components such as LO rejection filters were not required for a normal operation of the proposed downconverter MMIC. The proposed downconverter MMIC showed a conversion gain of 10.3 dB at RF frequency of 63 GHz. The size of the downconverter MMIC including all active and passive components was $2.2{\times}1.4mm^2$.