• Title/Summary/Keyword: 빔 영상시스템

Search Result 133, Processing Time 0.032 seconds

Design of 1× Optical Path Relay Adapter for Beam Splitting Prism used in Day & Night Scope (주야 관측경용 빔 분리프리즘을 위한 1× Optical Path Relay Adapter 설계)

  • Lee, Dong-Hee;Choi, Gyu-Jung;Jung, In;Park, Seung-Hwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.441-447
    • /
    • 2012
  • Purpose: This paper is about development and design of the 1x optical path relay adapter for the beam splitting prism by us the day & night scope. Methods: To product the day & night scope by using the beam splitting prism and the commercial zoom optical system with the C-mount lens barrel structure, the optical path relay adapter, which doesn't change the image size of the zoom optical system and can stretch the position of the image-forming surface, is needed. We could design the 1x optical path relay adapter by using the CodeV program in which the Lens Module mode is offered. Results: We could design the optical path relay adapter used in the day&night scope with the beam splitting prism, of which characteristics have the EFL of -56.0 mm, the magnification of +1.0x, the distance from the 1st lens surface to the last lens surface of about 20.4 mm. The resolution of this system is characterized by 30 lp/mm at 40% MTF. This is enough to accommodate the designed optical path relay adapter can overcome the resolution of the 3rd generation of image intesifier tubes. Conclusions: By designing and applying the optical path relay adapter of which optical characteristics have the EFL of -56.0 mm, the magnification of +1.0x, the distance from the 1st lens surface to the last lens surface of about 20.4 mm, and the resolution of 30 lp/mm at 40% MTF, we could develop the new type day&night scope consisting of the beam splitting, the commercial zoom optical system with the C-mount lens barrel structure, and the 3rd generation of image intesifier tubes.

A Study on a Stereoscopic Display System Using a Rotary Disk Type Beam Shutter (회전 디스크형 빔 셔터를 이용한 입체영상 디스플레이 시스템에 관한 연구)

  • Lee, Kwang-Hyung;Jang, Tae-Jeong
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.196-198
    • /
    • 2006
  • In this paper, a stereoscopic display system using a rotary disk tyre beam shutter and two beam projectors is proposed. It is a kind of active stereoscopic display and can be easily converted from passive stereoscopic system using polarizing filters. If it is possible to synchronize the revolution speed of the beam shutter with the integer multiple of the scanning frequency of the beam projectors, we can obtain a comparable performance with our system to an active stereoscopic system using one expensive high performance beam projector. Further, if we rotate the beam shutter at sufficiently high revolution speed, our active stereoscopic system works regardless of synchronization and thus the system is much easier to implement.

  • PDF

A Study on a Stereoscopic Display System Using a Rotary Disk Type Beam Shutter (회전 디스크형 빔 셔터를 이용한 입체영상 디스플레이 시스템에 관한 연구)

  • Lee, Kwang-Hyung;Jang, Tae-Jeong
    • 한국HCI학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.739-743
    • /
    • 2007
  • In this paper, a stereoscopic display system using a rotary disk type beam shutter and two beam projectors is proposed. It is a kind of active stereoscopic display and can be easily converted from passive stereoscopic system using polarizing filters. If it is possible to synchronize the revolution speed of the beam shutter with the integer multiple of the scanning frequency of the beam projectors, we can obtain a comparable performance with our system to an active stereoscopic system using one expensive high performance beam projector. Further, if we rotate the beam shutter at sufficiently high revolution speed, our active stereoscopic system works regardless of synchronization and thus the system is much easier to implement.

  • PDF

Real-Time 3D Ultrasound Imaging Method Using a Cross Array Based on Synthetic Aperture Focusing: II. Linear Wave Front Transmission Approach (합성구경 기반의 교차어레이를 이용한 실시간 3차원 초음파 영상화 기법 : II. 선형파면 송신 방법)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.403-414
    • /
    • 2004
  • In the accompanying paper, we proposed a real. time volumetric imaging method using a cross array based on receive dynamic focusing and synthetic aperture focusing along lateral and elevational directions, respetively. But synthetic aperture methods using spherical waves are subject to beam spreading with increasing depth due to the wave diffraction phenomenon. Moreover, since the proposed method uses only one element for each transmission, it has a limited transmit power. To overcome these limitations, we propose a new real. time volumetric imaging method using cross arrays based on synthetic aperture technique with linear wave fronts. In the proposed method, linear wave fronts having different angles on the horizontal plane is transmitted successively from all transmit array elements. On receive, by employing the conventional dynamic focusing and synthetic aperture methods along lateral and elevational directions, respectively, ultrasound waves can be focused effectively at all imaging points. Mathematical analysis and computer simulation results show that the proposed method can provide uniform elevational resolution over a large depth of field. Especially, since the new method can construct a volume image with a limited number of transmit receive events using a full transmit aperture, it is suitable for real-time 3D imaging with high transmit power and volume rate.

Evaluation of Scatter Reduction Effect of the Aft-Multiple-Slit (AMS) System Using MC Simulation (MC 시뮬레이션을 이용한 Aft-Multiple-Silt 시스템의 산란선 제거 효과 평가)

  • Chang, Jin-A;Suh, Tae-Suk;Jang, Doh-Yun;Jang, Hong-Seok;Kim, Si-Yong
    • Radiation Oncology Journal
    • /
    • v.28 no.4
    • /
    • pp.224-230
    • /
    • 2010
  • Purpose: We designed the aft-multiple-slit (AMS) system to reduce scatter in cone-beam computed tomography (CBCT). As a preliminary study, we performed a Monte Carlo N-Particle Transport Code (MCNP) simulation to verify the effectiveness of this system. Materials and Methods: The MCNPX code was used to build the AMS geometry. An AMS is an equi-angled arc to consider beam divergence. The scatter-reduced projection images were compared with the primary images only and the primary plus scatter radiation images with and without AMS to evaluate the effectiveness of scatter reduction. To obtain the full 2 dimensional (2D) projection image, the whole AMS system was moved to obtain closed septa of the AMS after the first image acquisition. Results: The primary radiation with and without AMS is identical to all the slit widths, but the profiles of the primary plus scattered radiation varied according to the slit widths in the 2D projection image. The average scatter reduction factors were 29%, 15%, 9%, and 8% when the slit widths were 5 mm, 10 mm, 15 mm, and 20 mm, respectively. Conclusion: We have evaluated the scatter reduction effect of the AMS in CBCT imaging using the Monte Carlo (MC) simulations. A preliminary study based on the MCNP simulations showed a mount of scatter reduction with the proposed system.

Correction for SPECT image distortion by non-circular detection orbits (비원형 궤도에서의 검출에 의한 SPECT 영상 왜곡 보정)

  • Lee, Nam-Yong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.3
    • /
    • pp.156-162
    • /
    • 2007
  • The parallel beam SPECT system acquires projection data by using collimators in conjunction with photon detectors. The projection data of the parallel beam SPECT system is, however, blurred by the point response function of the collimator that is used to define the range of directions where photons can be detected. By increasing the number of parallel holes per unit area in collimator, one can reduce such blurring effect. This approach also, however, has the blurring problem if the distance between the object and the collimator becomes large. In this paper we consider correction methods for artifacts caused by non-circular orbit of parallel beam SPECT with many parallel holes per detector cell. To do so, we model the relationship between the object and its projection data as a linear system, and propose an iterative reconstruction method including artifacts correction. We compute the projector and the backprojector, which are required in iterative method, as a sum of convolutions with distance-dependent point response functions instead of matrix form, where those functions are analytically computed from a single function. By doing so, we dramatically reduce the computation time and memory required for the generation of the projector and the backprojector. We conducted several simulation studies to compare the performance of the proposed method with that of conventional Fourier method. The result shows that the proposed method outperforms Fourier methods objectively and subjectively.

  • PDF

A Study on the Synthetic Aperture Radar System Motion Compensation Technique (SAR(Synthetic Aperture Radar)시스템 요동보상기법 연구)

  • Kang, Eun-Kyun;Ra, Keuk-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.3
    • /
    • pp.221-229
    • /
    • 2013
  • In this paper, the image formation by the motion compensation technique for Synthetic Aperture Radar system(SAR) were realized through the computer simulation. The motion compensation technique performed image data with the range compression, the compensation procedure, the azimuth compensation and the noise elimination procedure. The range compression procedure transform the SAR raw data into the frequency domain and correlate with the range reference function and then inversely transform into the time domain. The compensation procedure contain the aircraft fluctuations compensation and the radar image degrading effect elimination procedure which was caused by image formation algorithm itself. The aircraft fluctuations compensation procedure perform the first stage which correct the phase angle and the second stage which calculate the Doppler frequency and determine the coordinate of the received signal. The radar image degrading effect elimination procedure also perform range migration compensation and the image defocussing effect compensation. The azimuth compression procedure transform the compensation data to the frequency domain and correlate with the azimuth reference function. The azimuth correlated data are inversely transformed to the time domain which is called SAR image data. When the above procedure were completed, the image data contains the received signals mixed with noise. The threshold technique was applied to elimination the noise from the mixed image data.

FPGA-Based Low-Power and Low-Cost Portable Beamformer Design (FPGA 기반 저전력 및 저비용 휴대용 빔포머 설계)

  • Jeong, GabJoong;Park, CheolYoung
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.1
    • /
    • pp.31-38
    • /
    • 2019
  • In this paper, we develop a beamforming front end platform with pipeline circuit configuration method that can apply various clinical diagnostic applications of ultrasound image technology. Hardware design targets compression applications as well as scalable applications where power, integration levels and replication possibilities are important. Firmware design was implemented to achieve optimal FPGA parallel processing level by constructing new IP and system-oriented design environment to accelerate design productivity with maximum productivity improvement using Vivado HLS tool, which is a next generation high level synthesis tool. Former supports the high-speed management function of scan data that can create an image area arbitrarily and can be appropriately corrected and supplemented when reconfiguring or changing system specifications in the future.

Locates the Sunken Ship 'Dmitri Donskoi' using Marine Geophysical Survey Techniques in Deep Water (지구물리 탐사기법을 이용한 심해 Dmitri Donskoi호 확인)

  • Yoo, Hai-Soo;Kim, Su-Jeong;Park, Dong-Won
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.104-117
    • /
    • 2004
  • Dmitri Donskoi, which went down during the Russo-Japanese War occurred 100 years ago, was found by using geophysical exploration techniques at the 400 m water depth of submarine valley off Jeodong of Ulleung Island. In the submarine area with the rugged seabed topography and volcanic seamounts, in particular, the reliable seabed images were acquired by using the mid-to-shallow Multibeam exploration technique The strength of corrosion (causticity) of the sunken Donskoi, measured by the electrochemical method, decreased to 2/5 compared with the original strength.

  • PDF

Real-time Implementation and Application of Pointing Region Estimation System using 3D Geometric Information in Real World (실세계 3차원 기하학 정보를 이용한 실시간 지시영역 추정 시스템의 구현 및 응용)

  • Han, Yun-Sang;Seo, Yung-Ho;Doo, Kyoung-Soo;Kim, Jin-Tae;Choi, Jong-Soo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.2
    • /
    • pp.29-36
    • /
    • 2008
  • In this paper we propose a real-time method to estimate a pointing region from two camera images. In general, a pointing target exists in the face direction when a human points to something. Therefore, we regard the direction of pointing as the straight line that connects the face position with the fingertip position. First, the method extracts two points in the face and the fingertips region by using detecting the skin color of human being. And we used the 3D geometric information to obtain a pointing detection and its region. In order to evaluate the performance, we have build up an ICIGS(Interactive Cinema Information Guiding System) with two camera and a beam project.