• Title/Summary/Keyword: 부하저항

Search Result 349, Processing Time 0.021 seconds

DCM DC-DC Converter for Mobile Devices (모바일 기기용 DCM DC-DC Converter)

  • Jung, Jiteck;Yun, Beomsu;Choi, Joongho
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.319-325
    • /
    • 2020
  • In this paper, a discontinuous-conduction mode (DCM) DC-DC buck converter is presented for mobile device applications. The buck converter consists of compensator for stable operations, pulse-width modulation (PWM) logic, and power switches. In order to achieve small hardware form-factor, the number of off-chip components should be kept to be minimum, which can be realized with simple and efficient frequency compensation and digital soft start-up circuits. Burst-mode operation is included for preventing the efficiency from degrading under very light load condition. The DCM DC-DC buck converter is fabricated with 0.18-um BCDMOS process. Programmable output with external resistors is typically set to be 1.8V for the input voltage between 2.8 and 5.0V. With a switching frequency of 1MHz, measured maximum efficiency is 92.6% for a load current of 100mA.

Design and testing of 25kW bipolar pulse power supply for mineral exploration of Mt.Taebaek (광물 탐사용 25kW급 양극성 펄스전원장치 설계 및 태백산 탐사시험)

  • Bae, Jung-Soo;Kim, Shin;Kim, Tae-Hyun;Yu, Chan-Hun;Kim, Hyoung-Suk;Kim, Jong-Soo;Jang, Sung-Roc
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.257-259
    • /
    • 2019
  • 본 논문은 광물 탐사를 위한 25kW급 양극성 펄스전원장치에 대해 기술한다. 소프트스위칭 기반의 고효율 LCC 공진형 컨버터와 풀 브리지 기반 양극성 펄스 스위칭부로 구성된 단위 모듈(500V, 12.5A)을 기반으로 설계한다. LCC 공진형 컨버터는 전류의 rms값을 줄이기 위해 공진 전류모양을 사다리꼴 형태로 설계하여 도전 손실측면에서 크게 개선되었고, 높은 전력밀도를 달성하기 위해 변압기의 누설 인덕턴스를 공진 파라메터로 활용한다. 추가적으로, 짧은 펄스폭을 가지도록 설계된 게이트 구동 회로는 출력을 DC에서 8kHz의 넓은 주파수 범위에서 동작시킬 뿐만 아니라 게이트 신호를 전달하기 위한 변압기의 사이즈를 줄이기 위해 제안된다. 단위모듈 형태로 개발된 양극성 펄스전원장치는 4개의 모듈이 직병렬로 결선되어 부하조건에 따라 Grounded dipole mode (2kV, 12.5A) 또는 Loop mode (500V, 50A)로 동작한다. 4모듈 직병렬 운전 시 발생하는 모듈 간 전압 불균형 문제를 해결하기 위해 메인 변압기에 보상권선이 감긴다. 본 논문에서는 개발된 양극성 펄스전원 장치의 설계를 저항부하 실험 및 태백산 탐사시험 결과를 바탕으로 검증한다.

  • PDF

Effects of heat treatment on the load-deflection properties of nickel-titanium wire (니켈-티타늄 와이어의 열처리에 따른 부하-변위 특성 변화)

  • Chang, Soo-Ho;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.36 no.5
    • /
    • pp.349-359
    • /
    • 2006
  • Objective: Nickel-titanium alloy wire possesses excellent spring-back properties, shape memory and super-elasticity. In order to adapt this wire to clinical use, it is necessary to bend as well as to control its super-elastic force. The purpose of this study is to evaluate the effects of heat treatment on the load-deflection properties and transitional temperature range (TTR) of nickel-titanium wires. Methods: Nickel-titanium wires of different diameters ($0.016"\;{\times}\;0.022"$, $0.018"\;{\times}\;0.025"$ and $0.0215"\;{\times}\;0.028"$) were used. The samples were divided into 4 groups as follows: group 4, posterior segment of archwire (24 mm) without heat treatment; group 2, posterior segment of archwire (24 mm) with heat treatment only; group 3, anterior segment with bending and heat treatment; group 4, anterior segment with bending and 1 sec over heat treatment. Three point bending test was used to evaluate the change in load-deflection curve and obtained DSC (different scanning calorimetry) to check changes in $A_f$ temperature. Results: In the three point bending test, nickel-titanium wires with heat treatment only had higher load-deflection curve and loading and unloading plateau than nickel-titanium wires without heat treatment. Nickel-titanium wires with heat treatment had lower Af temperature than nickel-titanium wires without heat treatment. Nickel-titanium wires with heat treatment and bending had higher load-deflection curve than nickel- titanium wires with heat treatment and nickel-titanium wires without heat treatment. Nickel-titanium with heat treatment of over 1 sec and bending had the highest load-deflection curve. Nickel-titanium wires with heat treatment and bending had lower Af temperature, Nickel-titanium wires with heat treatment of over Af sec and bending had the lowest Af temperature. Conclusion: From the results of this study, it can be stated that heat treatment for bending of Nickel-titanium wires does not deprive the superelastic property but can cause increased force magnitude due to a higher load-deflection curve.

The effects of the mulberry and silkworm intake on androgen receptor mRNA and myogenic regulatory factors expression of rats muscle for resistance exercise (오디와 누에 섭취가 rats의 저항성 운동에 따른 androgen receptor mRNA와 myogenic regulatory factors의 발현에 미치는 영향)

  • Yang, Sung Jun;Kim, Chang Yong;Lee, Jo Byoung;Kang, Sung Sun;Lee, Jong Jin
    • Journal of Sericultural and Entomological Science
    • /
    • v.51 no.2
    • /
    • pp.99-106
    • /
    • 2013
  • The purpose of this study is to investigate the effects of supplementation of mulberry powder, mulberry extract and silkworm powder during the 8 weeks of resistance exercise on Androgen receptor(AR) mRNA and Myogenic regulatory factors(MRFs) expression of rats muscle. Fifty males, Sprague-Dawley rat, were randomly divided into 5 groups: CON(control group, n = 10), REG(resistance exercise group, n = 10), MP REG(mulberry powder intake and resistance exercise group, n = 10), ME REG(mulberry extract intake and resistance exercise group, n = 10) and SP REG(silkworm powder intake and resistance exercise group, n = 10). After climbing the ladder without weights during the 1 week of adaptation period, the rats in the resistance exercise group were trained to climb a 0.98-m vertical(80 degree incline) ladder with weights in their tail during 7 weeks(10 times each day, 2 days per week). After exercise, the skeletal muscle was extracted from the flexor hallucis longus. After separating the total ribonucleic acid (RNA) of each group, quantitative polymerase chain reaction was used to analyze RNA quantitatively. AR mRNA and MRFs expression revealed that all of the treated groups had significantly difference. AR mRNA expression increased in ME REG $6.24{\pm}1.85$ and SP REG $9.68{\pm}0.28$ fold compared to CON. Myod mRNA expression increased in MP REG $6.04{\pm}0.47$, ME REG $4.31{\pm}1.58$ and SP REG $8.11{\pm}0.57$ fold compared to CON. And myogenin mRNA expression increased in MP REG $4.11{\pm}0.42$, ME REG $4.12{\pm}0.45$ and SP REG $6.50{\pm}0.61$ fold compared to CON. In conclusion, during the resistance exercise, providing mulberry and silkworm gives positive effect on AR mRNA and MRFs expression increase.

Impedance Spectroscopic Properties of Mn Deposition on Al Oxide Layer (Al 양극산화피막에서 Mn전착에 관한 임피던스 연구)

  • Oh, Han Jun;Jang, Kyung Wook;Chi, Choong Soo
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.1
    • /
    • pp.23-29
    • /
    • 1999
  • The Al oxide layer formed in 1M $H_2SO_4$ solution and the influence of applied frequency for electrodeposition of Mn on Al oxide layer were characterized using by impedance spectroscopy. Mn compounds were electrodeposited at the base of pores during deposition with applied low frequency voltage. For the Mn deposited oxide layer at 6OHz and 5Hz in 1 g/L $KMnO_4$ solution, in equivalent circuit for interpretation, the resistance ($R_2$) and capacitance ($C_2$) were considered to be due to deposition of Mn on base of pore. The electrochemical behavior of barrier layer and porous oxide layer on Al have been characterized by capacitance ($C_b$) and Young capacitance ($C_Y$) in equivalent circuit model.

  • PDF

HIPI Controller of IPMSM Drive using ALM-FNN (ALM-FNN을 이용한 IPMSM 드라이브의 HIPI 제어기)

  • Ko, Jae-Sub;Choi, Jung-Sik;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.57-66
    • /
    • 2009
  • The conventional fixed gain PI controller is very sensitive to step change of command speed, parameter variation and load disturbances. The precise speed control of interior permanent magnet synchronous motor(IPMSM) drive becomes a complex issue due to nonlinear coupling among its winding currents and the rotor speed as well as the nonlinear electromagnetic developed torque. Therefore, there exists a need to tune the PI controller parameters on-line to ensure optimum drive performance over a wide range of operating conditions. This paper proposes hybrid intelligent-PI(HIPI) controller of IPMSM drive using adaptive learning mechanism(ALM) and fuzzy neural network(FNN). The proposed controller is developed to ensure accurate speed control of IPMSM drive under system disturbances and estimation of speed using artificial neural network(ANN) controller. The PI controller parameters are optimized by ALM-FNN at all possible operating condition in a closed loop vector control scheme, The validity of the proposed controller is verified by results at different dynamic operating conditions.

Durability of MEA Using sPEEK Membrane Reinforced with Poly Imide in PEMFC (고분자전해질연료전지에서 폴리이미드 강화 sPEEK막 MEA의 내구성)

  • Lee, Hye-Ri;Na, Il-Chai;Oh, Sung-Jun;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.296-301
    • /
    • 2017
  • Recently, there are many efforts focused on development of more economical non-fluorinated membranes for PEMFCs (Proton Exchange Membrane Fuel Cells). In this study, sulfonated poly (ether ether ketone) (sPEEK) membrane reinforced with poly imide was made to enhance of membrane durability. In order to test durability of single (un-reinforced) membrane and reinforced membrane MEA (Membrane and Electrode Assembly), degradation accelerated stress test was used. Before and after degradation, I-V polarization curve, hydrogen crossover current, electrochemical surface area, membrane resistance and charge transfer resistance were measured. As a result of experiments, hydrogen crossover current of reinforced MEA was lower than that of single MEA, therefor durability of reinforced MEA was higher than that of single MEA. There was not especially short phenomena in reinforced MEA after degradation accelerated stress test.

The Effect of 12 Weeks of Combined Training on Body Composition, Health-Related Physical Fitness, and Bone Mineral Density of Obese and Osteoporotic Intellectual Disabilities-Case study (12주간 복합트레이닝이 비만과 골다공증 지적장애인의 신체조성, 건강체력, 골밀도에 미치는 영향-사례연구)

  • Han, Dong-Ki;Yang, Han-Nah;Seo, Jin-Hee
    • Journal of Digital Convergence
    • /
    • v.16 no.2
    • /
    • pp.375-383
    • /
    • 2018
  • The purpose of this study was to investigate the effect of exercise training on health-related physical fitness and osteoporosis after 12 weeks of combined training for adults with intellectual disabilities diagnosed with obesity and osteoporosis. The subjects conducted a combined training program consisting of aerobic exercise and strength training twice a week for 12 weeks. Body composition and bone mineral density were measured before exercise, 6, 12 weeks, and health-related physical fitness was measured before and after exercise. Body weight and body fat decreased after exercise and bone density increased after exercise compared to before exercise. Muscle strength, muscle endurance and flexibility were improved after exercise compared to before exercise. It was confirmed that the 12 week compound training increased the leg strength and improved the functions such as walking and running, and increased the health-related fitness and increased bone mineral density.

Characteristics of the Water Pressure Drop Considering Heat Transfer in the Evaporator and Condenser of a Water Chiller (냉수공장에서 열전달을 고려한 응축기와 증발기의 물 압력강하 특성)

  • Nguyen, Minh Phu;Lee, Geun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1293-1300
    • /
    • 2011
  • The configurations of the evaporator and condenser of a water chiller can be determined from the trade-off between the heat transfer area, which is related to the capital cost and the pressure drop, which is associated with the operational cost. In this study, the design of the water chiller focused on minimizing the water pressure drop of both condenser and evaporator for given cooling capacity and requirements. Commercial enhanced tubes were employed to simulate real-life conditions. The results of the present analysis were compared with those obtained by HTRI software for verifying them. The results indicated that a reduction in the water pressure drop, which is associated with the short length of a tube, can be effected by decreasing the number of tube passes and increasing the number of tubes and the tube diameter. However, using a large number of tubes with smaller diameters can reduce the capital cost because the tubes are short. The reduction of the capital cost is due to the fact that a small-diameter tube has low internal thermal resistance and hence contributes to a decrease in the overall thermal resistance per unit length.

Characteristics of Poly(arylene ether sulfone) Membrane for Proton Exchange Membrane Fuel Cells (고분자전해질 연료전지용 Poly(arylene ether sulfone) 막의 특성)

  • Jeong, Jae-Jin;Shin, Yong-Cheol;Lee, Moo-Seok;Lee, Dong-Hoon;Na, Il-Chai;Lee, Ho;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.51 no.5
    • /
    • pp.556-560
    • /
    • 2013
  • Recently, there are many efforts focused on development of more economical non-fluorinated membranes for use in PEMFCs (Proton Exchange Membrane Fuel Cells). In this study, characteristics of poly(arylene ether sulfone)(PAES) were compared with fluorinated membrane at PEMFC operation condition. I-V polarization curve, hydrogen crossover, electrochemical surface area, membrane resistance and charge transfer resistance were measured. PAES membrane showed similar performance compared with fluorinated membrane at 100% relative humidity, but the performance of PAES membrane decreased largely due to low ionic conductivity at low relative humidity.