1 |
Miura F, Mogi M, Ohura Y, Hamanaka H. The super-elastic property of the Japanese NiTi alloy wire for use in orthodontics. Am J Orthod Dentofacial Orthop 1986;90:1-10
DOI
ScienceOn
|
2 |
Chen R, Zhi YF, Arvystas MG. Advanced Chinese NiTi alloy wire and clinical observations. Angle Orthod 1992;62:59-66
|
3 |
Miyazaki S, Ohmi Y, Otsuka Y, Suzuki Y. Characteristics of deformation and transformation pseudoelasticity in Ti-Ni alloys. J Phys-Paris supplement 1982;255-60
|
4 |
Andreasen GF, Hilleman TB. An evaluation of 55 cobalt substituted Nitinol wire for use in orthodontics. J Am Dent Assoc 1971;82:1373-5
DOI
|
5 |
Stamm T, Hohoff A, Wiechmann D, Sutfeld J, Helm D. Accuracy of third-order bends of nickel-titanium wires and the effect of high and low pressure during memorizing heat treatment. Am J Orthod Dentofacial Orthop 2004;126:476-85
DOI
ScienceOn
|
6 |
Lee JH, Park JB, Andreasen GF, Lakes RS. Thermomechanical study of Ni-Ti alloys. J Biomed Mater Res 1988;22:573-88
DOI
ScienceOn
|
7 |
Kusy RP. A review of contemporary archwires: their properties and characteristics. Angle Orthod 1997;67:197-207
|
8 |
Otsubo K, Yoneyama T, Hamanaka H, Soma K. Influence of temperature on the force level of a super-elastic Ni-Ti alloy wire under strain. J J Dent Mater 1993;12:521-7
|
9 |
Oltjen JM, Duncanson MG Jr, Ghosh J, Nanda RS, Currier GF. Stiffuess-deflection behavior of selected orthodontic wires. Angle Orthod 1997;67:209-18
|
10 |
Andreasen GF, Morrow RE. Laboratory and clinical analyses of nitinol wire. Am J Orthod 1978;73:142-51
DOI
ScienceOn
|
11 |
Andreasen GF, Brady PR. A use hypothesis for 55 Nitinol wire for orthodontics. Angle Orthod 1972;42:172-7
|
12 |
Abel E, Luo H, Pridham M, Slade A. Issues concerning the measurement of transformation temperatures of NiTi alloys. Smart Mater Struct 2004;13:1110-7
DOI
ScienceOn
|
13 |
Wilkinson PD, Dysart PS, Hood JA, Herbison GP. Load-deflection characteristics of supere1astic nickel-titanium orthodontic wires. Am J Orthod Dentofacial Orthop 2002;121:483-95
DOI
ScienceOn
|
14 |
BK Cha, DS Choi, NK Lee. SimpIication of orthodontic treatment procedure using superelastic Ni-Ti archwires: One wire system. Korean J Clin Orthod 2005;11:82-9
|
15 |
Gil FJ, Manero JM, Planell JA. Effect of grain size on the martensitiec transformation in NiTi alloy. J Mater Sci 1995;30:2526-30
DOI
|
16 |
William AB, Theodore E. Wire Alloy. Orthodontic materials scientific and clinical aspects 2001;4:84-104
|
17 |
Miura F, Mogi M, Ohura Y. Japanese NiTi alloy wire: use of the direct electric resistance heat treatment method. Eur J Orthod 1988;10:187-91
DOI
|
18 |
Nakano H, Satoh K, Norris R, Jin T, Karnegai T, Ishikawa F, Katsura H. Mechanical properties of several nickel-titanium alloy wires in three-point bending tests. Am J Orthod Dentofacia1 Orthop 1999;115: 390-5
DOI
ScienceOn
|
19 |
Bradley TG, Brantley WA, Culbertson BM. Differential scanning calorimetry (DSC) analyses of superelastic and nonsuperelastic nickel -titanium orthodontic wires. Am J Orthod Dentofacial Orthop 1996;109:589-97
DOI
ScienceOn
|
20 |
Burstone CJ, Qin B, Morton JY. Chinese NiTi wire-a new orthodontic alloy. Am J Orthod 1985;87:445-52
DOI
ScienceOn
|
21 |
Yoneyama T, Doi H, Hamanaka H, Okamoto Y, Mogi M, Miura F. Super-elasticity and thermal bahavior of Ni-Ti alloy orthdontic arch wires. Dent Mater J 1992;11:1-10
DOI
ScienceOn
|
22 |
Gamer LD, Allai WW, Moore BK. A comparison of frictional forces during simulated canine retraction of a continuous edgewise arch wire. Am J Orthod Dentofacial Orthop 1986;90:199-203
DOI
ScienceOn
|
23 |
Kim YB. A reassessment of orthodontic wire selection. J Korean Gnatho-Orthod Res 1995;2:151-97
|
24 |
American Dental Association ASC MD 156: Restorative and Orthodontic Materials. Specification #32
|