• Title/Summary/Keyword: 부착 실험

Search Result 2,841, Processing Time 0.028 seconds

Broadband Transmission Noise Reduction Performance of Smart Panels Featuring Piezoelectric Shunt Damping and Passive Characteristics (압전감쇠와 수동적 특성을 갖는 압전지능패널의 광대역 전달 소음저감성능)

  • 이중근;김재환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.150-159
    • /
    • 2002
  • The possibility of a broadband noise reduction of piezoelectric smart panels is experimentally studied. Piezoelectric smart panel is basically a plate structure on which piezoelectric patch with shunt circuits is mounted and sound absorbing material is bonded on the surface of the structure. Sound absorbing materials can absorb the sound transmitted at mid frequency region effectively while the use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. To be able to tune the piezoelectric shunt circuit, the measured electrical impedance model is adopted. Resonant shunt circuit composed of register and inductor in stories is considered and the circuit parameters are determined based on maximizing the dissipated energy through the circuit. The transmitted noise reduction performance of smart panels is investigated using an acoustic tunnel. The tunnel is a square crosses sectional tunnel and a loud speaker is mounted at one side of the tunnel as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across the panels is measured. Noise reduction performance of a double smart panel possessing absorbing material and air gap shows a good result at mid frequency region except the first resonance frequency. By enabling the piezoelectric shunt damping, noise reduction is achieved at the resonance frequency as well. Piezoelectric smart panels incorporating passive method and piezoelectric shunt damping are a promising technology for noise reduction in a broadband frequency.

Enhanced Transdermal Delivery of Vitamin C Derivative using lontophoretic Gel Patch with Flexible Thin Layer Battery (Flexible Thin Layer Battery가 부착된 lontophoretic Gel Patch를 이용한 Vitamin C 유도체의 경피 흡수 증진)

  • Cho, Wan-Goo;Rang, Mun-Jeong;Song, Young-Sook;Lim, Young-Ho;Park, Hyeon-Woo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.33 no.1 s.60
    • /
    • pp.23-28
    • /
    • 2007
  • Ascorbic acid (vitamin C, AsA) has been known as a strong reducing agent and is supposed to retard the synthesis of melanin pigment. A main problem that arose in using vitamin C in cosmetic formulation was its poor stability and low skin permeability, which result in low lightening efficacy in clinical trials. In this study, iontophoretic gel patch with flexible thin layer battery was employed in order to enhance skin permeation of vitamin c derivative (ascorbyl glucoside, AsAG) and to increase its lightening efficacy. in vitro iontophoretic skin permeation and stability of AsAG, safety and clinical lightening efficacy of iontophoretic patch containing 2% AsAG solution were examined. A optimun current of ionthophoretic patch for korean women was 0.1 mA, considering the skin permeability and skin irritation of consumers. We suggest that iontophoretic gel patch could be a safe system for enhancing the skin permeation of AsAG and lightning efficacy.

Evaluation of Washing Efficiency of Collective PM by Electrostatic Precipitator in Subway Station Using Nano Bubble (나노버블을 이용한 지하철용 전기집진기 포집먼지에 대한 세척효율 평가)

  • Lee, Hyung-Don;Lee, Seung-Hwan;Park, Chan-gyu
    • Clean Technology
    • /
    • v.26 no.1
    • /
    • pp.13-21
    • /
    • 2020
  • Air pollutants in a subway are complexly caused by outdoor factors such as ventilating opening and indoor factors such as the movement of passengers on the subway. According to recent research results, most of the air pollutants generated in subway tunnels and stations are caused by indoor variables such as train movement. To control air pollutants such as particulate matter (PM), a prevention facility such as the electrostatic precipitator (EP) or bag filter collector was required in a subway station. In particular, the PM removed by the EP must be kept clean continuously to manage PM effectively. Therefore, a nano-bubbling washing system was developed in this study to clean a contaminated collecting plate in an EP at the main subway tunnel in Seoul. Removal efficiency compared with normal water and nano-bubbling water was likewise studied. As a result, the washing efficiency of collective PM increased in accordance with the increasing of injection pressure, with nano bubbling washing being 130.8% higher than tap water. According to increase in washing times, the maximum washing efficiency was 143.1% higher than tap water, but suitable washing times were less than 3 times. According to the results of the washing efficiency by variation of residence time, it was confirmed that the maximum residence time of nano-bubble water was maintained within 5 minutes.

The Experimental Study on The Compressive Strength of Concrete Using High Quality Recycled Fine Aggregate Produced by Sulphuric Water and Low Speed Wet Abrasional (황산수와 저속습식마쇄기로 생산된 고품질 순환 잔골재의 콘크리트 압축강도에 관한 실험적 연구)

  • Choi, Duck-Jin;Lee, Dae-Guen;Kim, Ha-Suk;Kawk, Eun-Gu;Kang, Chul;Kim, Jin-Man
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.385-388
    • /
    • 2008
  • Recycled fine aggregate has low quality because it contains large amount of old mortar. So, its usage is limited to a lower value-add, such as the roadbed material etc. Also, alkaline water occurred from treatment process of the waste concrete is becoming the cause of environmental problem. Accordingly, this study is to develop on the high quality recycled fine aggregate produced by low speed wet abraser using sulphuric. We investigated the properties of compressive strength of the mortar which was manufactured using recycled fine aggregate containing calcined gypsum produced by earlier mentioned process. Test results indicate that concrete using recycled fine aggregate containing calcined gypsum is higher compressive strength than concrete using other sands.

  • PDF

Mechanical Properties of Strain-Hardening Cement Composites(SHCCs) according to the Water-Cement Ratio (물시멘트비에 따른 변형경화형 시멘트 복합체의 역학적 특성)

  • Kim, Yun-Su;Jang, Yong-Heon;Jang, Gwang-Su;Jeon, Esther;Yun, Hyun-Do;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.465-468
    • /
    • 2008
  • SHCCs (Strain Hardening Cement Composites) show the high energy tolerance capacity due to the interfacial bonding of the fibers to the cement matrix. For effective material design and application of SHCCs, it is needed to investigate the compression, four-point bending, direct tensile response of SHCCs with different types of fibers and water-cement ratio. For these purposes, three kinds of fibers were used: PP(polypropylene, 2.0%), PVA(Polyvinyl alcohol, 2.0%), PE (Polyethylene, 1.0%). Also, effects of water-cement ratio(0.45, 0.60) on the SHCCs were evaluated in this paper. As the result of test, SHCCs with PVA and PE fiber were showed better overall behavior than specimens with PP fibers on bending and direct tensile test. Also, for the same type of fiber, SHCCs with water-cement ratio of 0.45 exhibited higher ultimate strength than specimen with water-cement ratio of 0.60 on compression strength, and showed the multiple cracking on bending and direct tensile test. Therefore, to improve of workability and dispersibility of SHCCs on water-cement ratio of 0.60, continual studies were needed.

  • PDF

Model Identification for Control System Design of a Commercial 12-inch Rapid Thermal Processor (상업용 12인치 급속가열장치의 제어계 설계를 위한 모델인식)

  • Yun, Woohyun;Ji, Sang Hyun;Na, Byung-Cheol;Won, Wangyun;Lee, Kwang Soon
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.486-491
    • /
    • 2008
  • This paper describes a model identification method that has been applied to a commercial 12-inch RTP (rapid thermal processing) equipment with an ultimate aim to develop a high-performance advanced controller. Seven thermocouples are attached on the wafer surface and twelve tungsten-halogen lamp groups are used to heat up the wafer. To obtain a MIMO balanced state space model, multiple SIMO (single-input multiple-output) identification with highorder ARX models have been conducted and the resulting models have been combined, transformed and reduced to a MIMO balanced state space model through a balanced truncation technique. The identification experiments were designed to minimize the wafer warpage and an output linearization block has been proposed for compensation of the nonlinearity from the radiation-dominant heat transfer. As a result from the identification at around 600, 700, and $800^{\circ}C$, respectively, it was found that $y=T(K)^2$ and the state dimension of 80-100 are most desirable. With this choice the root-mean-square value of the one-step-ahead temperature prediction error was found to be in the range of 0.125-0.135 K.

THE THERAPEUTIC EFFECT OF FLUORIDE-CONTAINING ADHESIVE TAPE ON DENTIN HYPERSENSITIVITY (불소함유 접착 테이프의 상아질 지각과민증 치료효과)

  • Jang, Hyang-Gil;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.367-376
    • /
    • 2009
  • In this clinical research, the fluoride tape(SCMC-T-5) using fluoride(NaF) was developed and manufactured and the treatment effect of the fluoride tape in dentin hypersensitivity patients was evaluated and compared with the effect of existing fluoride varnish($CavityShield^{TM}$). Twenty two healthy adult patients(88 teeth) having dentin hypersensitivity participated in this clinical research and they were divided into two groups. The fluoride product was applied according to the manufacturer's instruction and the level of pain in the tooth after giving irritation using compressed air and ice stick was measured just after the application, after 3 days, after a week and after 4 weeks each using visual analog scale(VAS). In the experimental group, compared with the early VAS scores, all other VAS scores showed the significant decreases statistically. In the control group, all VAS scores except the VAS score of 34.091(air) measured 3 days after(using the irritation examination by the compressed air) showed the significant decreases statistically when compared with the early VAS scores. The fluoride tape and fluoride varnish used in this clinical research were able to treat the dentin hypersensitivity effectively.

  • PDF

Target Localization and Dose Delivery Verification used a Water Phantom in Stereotactic Radiosurgery (정위적 방사선 수술에서 물팬텀을 이용한 목표점 및 전달 선량확인)

  • Kang, Young-Nam;Lee, Dong-Jun;Kwon, Soo-Il;Kwon, Yang
    • Progress in Medical Physics
    • /
    • v.7 no.2
    • /
    • pp.19-28
    • /
    • 1996
  • It is important that the precise decision of the region and the accurate delivery of radiation dose required for treatment in the stereotactic radiosurgery. In this research, radiosurgery was carried with Leksell streotactic frame(LSF) which is especially developed water phantom to verify in experiment. Leksell Gamma Knife and LSF are used in radiosurgery is the spherical water phantom has the thickness of 2 mm, the radius of 160mm. The film for target localization and ionchamber for dose delivery was used in measurement instruments We compare the coordinate of target which is initialized by biplannar film with simple X-ray to the coordinate of film measured directly. The calculated dose by computer simulation and the measured dose by ionization chamber are compared. In this research, the target localization has the range ${\pm}$0.3mm for the acceptable error range and the absolute dose is :${\pm}$0.3mm for the acceptable error range. This research shows that the values measured by using the especially manufactured phantom are included the acceptable error range. Thus, this water phantom will be used continuously in the periodic quality assurance of Gamma Knife Unit and Leksell Stereotactic Frame.

  • PDF

The Treatment of Synthetic Wastewater by Biological Fluidised Bed With Air Lift Aeration (간접폭기식(間接曝氣式) 생물학적(生物學的) 유동층(流動層)을 이용한 합성하수(合成下水) 처리(處理))

  • Kim, Hwan Gi;Lee, Ki Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.3
    • /
    • pp.33-44
    • /
    • 1987
  • To improve the ability of oxygen transfer in Biological Fluidised Bed(BFB) processes, air lift aeration system was introduced, experimental investigations were performed for the oxygen transfer in reactor, the fluidisation as to Biomass Volatile Solids variation and the relationship between substrate removal rate and oxygen utilization. The experiments for this purpose were executed for the synthetic wastewater by continuous type reactor at $20^{\circ}C$ using reticulated polypropylene sheets as media. The obtained results showed that the oxygen transfer by air lift aeration would be more effective than any other aeration systems used in BFB reactor. Also, it has observed that the critical biomass concentration in reactor took a range of 20 to 23g/l. Applying cages to BFB reactor, biomass would be maintained uniformly in the bed and the fluidisation characteristics of media could be improved. Varying F/M ratio from 0.36 to 0.73, BOD removals were 91% or more. Therefore, this process was suited to the treatment of which F/M ratios are variable and specific oxygen uptake rates ($K_r$) were 0.23 to 0.26g $O_2/g\;VSS{\cdot}day$ at range of 15 to 20g BVS/l.

  • PDF

Characterization of Interfacial Adhesion of Cu-Cu Bonding Fabricated by Thermo-Compression Bonding Process (열가압 접합 공정으로 제조된 Cu-Cu 접합의 계면 접합 특성 평가)

  • Kim, Kwang-Seop;Lee, Hee-Jung;Kim, Hee-Yeoun;Kim, Jae-Hyun;Hyun, Seung-Min;Lee, Hak-Joo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.7
    • /
    • pp.929-933
    • /
    • 2010
  • Four-point bending tests were performed to investigate the interfacial adhesion of Cu-Cu bonding fabricated by thermo-compression process for three dimensional packaging. A pair of Cu-coated Si wafers was bonded under a pressure of 15 kN at $350^{\circ}C$ for 1 h, followed by post annealing at $350^{\circ}C$ for 1 h. The bonded wafers were diced into $30\;mm\;{\times}\;3\;mm$ pieces for the test. Each specimen had a $400-{\mu}m$-deep notch along the center. An optical inspection module was installed in the testing apparatus to observe crack initiation at the notch and crack propagation over the weak interface. The tests were performed under a fixed loading speed, and the corresponding load was measured. The measured interfacial adhesion energy of the Cu-to-Cu bonding was $9.75\;J/m^2$, and the delaminated interfaces were analyzed after the test. The surface analysis shows that the delamination occurred in the interface between $SiO_2$ and Ti.