• 제목/요약/키워드: 보강 섬유

검색결과 1,623건 처리시간 0.028초

선배합방법에 의한 섬유보강 시멘트의 강도 특성에 관한 연구 (A Study on the Strength Properties of Glass Fiber Reinforced Cement made by Premixing Method)

  • 김용부;조정민
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1990년도 봄 학술발표회 논문집
    • /
    • pp.5-10
    • /
    • 1990
  • There are two main methods in reinforcing cements with glass fibers : spray-suction and premixing method. But GRC have been mostly studied by spray technique. In order to develop GRC made by premixing method, in this paper, the influence of glass fiber length, volume content and curing conditions upon the compressive, direct tensile and bending strengths of composites fabricated by a premixing method, were investigated. According to the test results, although it was difficult to obtain perfectly uniform distribution of fibers in GRC Pannel, it was found that tensile strength of cements with glass fiber was improved 2~5 times and flexural strength 4 times compared to conventional cement mortar upto fiber length 35 mm, volume content 4%.

  • PDF

유리섬유쉬트로 보강된 콘크리트 기둥의 유한요소해석 (Finite Element Analysis of Concrete Columns Strengthened with Glass Fiber Sheets)

  • 정택원;송하원;변근주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.449-454
    • /
    • 2002
  • For finite analysis of concrete columns strengthened with glass fiber sheets, an effective concrete model which considers the confining effects by lateral reinforcement and glass fiber sheets is necessary. In this paper, the so-called elasto-plasticity and continuum fracture model (EPF model) is modified to consider high confining effects of strengthened reinforced concrete columns by introducing a simple correction factor ($\alpha$) which relates maximum lateral confining stress of the column to the evolution of deviatoric plasticity. Then, a finite element analysis is carried out for the strengthened reinforced concrete columns using the modified EPF model and equally spaced truss elements. It is shown that the, analysis predicts well the failure behavior of reinforced concrete columns strengthened with glass fiber sheets.

  • PDF

유리섬유 보강 원형 철근콘크리트 교각의 내진성능에 관한 준정적 실험연구 (Quasi-Static Test for Seismic Performance of Circular R.C. Bridge Piers Before and After Retrofitting)

  • 정영수;이강균;한기훈;이대형
    • 콘크리트학회논문집
    • /
    • 제11권5호
    • /
    • pp.107-118
    • /
    • 1999
  • 10 RC bridge piers have been made on a 1/3.4 scale model, and six piers of them were retrofitted with glassfiber. The have been tested in the quasi-static cyclic load so as to investigate their seismic enhancement before and after retrofitting with glassfibers. The objective of this experimental study is to investigate how to strength the ductility of reinforced concrete bridge piers which have been nonseismically designed and constructed in Korea before 1992. Important test parameters are axial load, load pattern, retrofit type. Glassfiber sheets were used for retrofitting in the plastic hinge region of concrete piers. The nonlinear behavior of bridge columns have been evaluated through their yield and ultimate strength, energy dissipation, displacement ductility and load-deflection characteristics under quasi-static cyclic loads. It can be concluded from the test that concrete piers strengthened with glassfibers have been enhanced for their ductile behavior by approximate 50%.

Steel Cord와 PVA 혼합섬유 보강 고인성 시멘트 복합체의 비빔 및 압축강도 특성 (Mixing and Compressive Strength Characteristics of Steel Cord and PVA Hybrid Fiber Reinforced Cement-Based Composites)

  • 윤현도;양일승;한병찬;복산양;전에스더;문연준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.28-31
    • /
    • 2004
  • This paper discusses the role of micro and macrofibers in the workability, compressive strength, and failure of cementitious composites. Workability(flow), compressive strength, splitting strength and fracture mechanism of hybrid fiber reinforced cement composites(HFRCC) have been investigated by means of Korean Standard (KS). The specific blend pursued in this investigation is a combination of polyvinyl alcohol(PVA) and steel cord. It was demonstrated that a hybrid combination of steel and PVA enhances fiber dispersion compared to only steel cord reinforced cement composites and that the brittle and wide cracking was much reduced in HFRCC as expected because in the matrix containing the PVA fiber around the steel cord, a multiple microcracking occurred and the steel cord could sufficiently work for bridging the cracked surface.

  • PDF

재료요인이 초고강도 강섬유 보강 시멘트 복합체의 압축강도에 미치는 영향 (The effect of material factors on the compressive strength of ultra-high strength Steel Fiber Reinforced Cementitious Composites)

  • 박정준;고경택;강수태;류금성;김성욱;이장화
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.288-291
    • /
    • 2004
  • In this paper, to make ultra-high strength SFRCC with the range of compressive strength 180MPa, it was investigated the constitute factors of ultra-high strength SFRCC influenced on the compressive strength. The experimental variables were water-cementitious ratio, replacement of silica fume, size and proportion of sand, type and replacement of filling powder, and using of steel fiber in ultra-high strength SFRCC. As a result, in water-binder ratio 0.18, we could make ultra-high strength SFRCC with compressive strength 180MPa through using of silica fume, quartz sand with below 0.5mm, filling powder and steel fiber.

  • PDF

아라미드섬유쉬트로 휨 보강된 RC보의 부착파괴 방지 상세에 관한 실험적 연구 (An Experimental Study to Prevent Debdonding Failure of RC Beams Strengthened by Aramid Fiber Sheets)

  • 최기선;유영찬;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.84-87
    • /
    • 2004
  • Nominal flexural strength of RC members strengthened with FRP sheets is generally based on the tensile strength of composite materials obtained from coupon tests. This method is based on the assumption that bond failure does not occur until the FRP sheet reaches its rupture strength. According to the previous researches, however, bond failure often occurs before the FRP sheet reaches its rupture strength. Some attempts were made to control debonding failure by increasing the bonded length of sheet or wrapping the section around their side of the member(U-wrap). In this study, the flexural failure mechanism of RC beams strengthened with AFRP sheets with different bond lengths is investigated. Their strengthening details to prevent the premature debonding failure are also suggested and its effectiveness is verified.

  • PDF

하이브리드 섬유 보강 시멘트 복합체의 인장 특성에 관한 연구 (A Study on Tension Properties on Hybrid Fiber Reinforced Cement-Based Composit)

  • 안영태;홍성걸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.340-343
    • /
    • 2004
  • The cement-based composites have been used for construction industry because of their economy, suitability for architecture and structure function, fire resistance, low fee of repair, easiness for acquisition. but the limited strain capacity of these makes them tension-weak, brittle, and considerable notch-sensitive. As one of solution, FRC(fiber reinforced concrete) have been investigated for regulating weakness of the cement-based composites. In these day different fiber types are proposed for better performance such as HFRC(hybrid fiber reinforced concrete). This study shows experimental results to search the ultimate strength, the ultimate mean strain, and the tension toughness of HFRC. The tension toughness is proportional to the amount of steel fiber and carbon fiber. In this experimental program we kept the total of steel fiber and carbon fiber as $1.0\%,\;1.5\%$, respectively.

  • PDF

Steel Cord와 PVA 혼합섬유 보강 고인성 시멘트 복합체의 인장강도 특성 (Tensile Strength Characteristics of Steel Cord and PVA Hybrid Fiber Reinforced Cement-Based Composites)

  • 윤현도;양일승;한병찬;복산양;전에스더;문연준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.18-21
    • /
    • 2004
  • This paper discusses how steel cord and PVA hybrid fibers enhance the performance of high performance fiber reinforced cementitious composites (HPRFCC) in terms of elastic limit, strain hardening response and post peak of the composites. The effect of microfiber(PVA) blending ratio is presented. For this purpose flexure, direct tension and split tension tests were conducted. It was found that HFRCC specimen shows multiple cracking in the area subjected to the greatest bending tensile stress. Uniaxial tensile test confirms the range of tensile strain capacity from 0.5 to $1.5\%$ when hybrid fiber is used. The cyclic loading test results identified a unique unloading and reloading response for this ductile composite. Cyclic loading in tension appears not to affect the tensile response of the material if the uniaxial compressive strength during loading is not exceeded.

  • PDF

섬유보강 폴리머 시멘트 모르타르의 초기수축균열 및 내구특성 (Plastic Shrinkage and Durability Characteristics of Fiber Reinforced Polymer-Modified Mortars)

  • 원종필;장필성;김명균;공태웅
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.156-159
    • /
    • 2004
  • The intention of this study is to reduce the plastic shrinkage of the polymer modified cement mortar using the PVA fiber. The durability of PVA fiber reinforced polymer cement mortar was also evaluated. The test results of PVA fiber reinforced polymer modified cement mortar were compared with plain polymer modified cement mortar(non-fiber). In conclusion, PVA fiber reinforced polymer modified cement mortar showed an ability to reduce the total crack area and maximum crack width significantly. Also. fiber reinforced polymer modified cement mortar show improved durability performance.

  • PDF

훅트강섬유보강철근콘크리트보의 휨거동에 관한 실험적 연구 (Experimental Study on the Flexural Behavior of Reinforced Hooked Steel Fibrous Concrete Beam)

  • 심종성;이차돈;김규선;오홍섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.311-318
    • /
    • 1995
  • Increases in strength and ductilities of steel fiber reinforced concrete(SFRC) under direct tension and compression result in improvements of flexural behavior of reinforced steel fibrous concrete beam(RSFCB) Use of hooked steel fibers in stead of round steel fibers enhances futher the structural porperties of a beam due to their greater mechanical bond resistance compared to that of round steel fibers. Flexural strength, initial stiffness ductility and failure mechani는 of RSFCB are dependent upon material and structural parameters and among which are the volume fraction of fibers, reinforcement ratio, and casting depth of SFRC in a beam section. The flexural behavior of RSFCB's are examined experimentally in this study and some conclusions are made regarding those effects of main material and structural parameters on the overall behavior of RSFCB.

  • PDF