• Title/Summary/Keyword: 벤츄리 관

Search Result 9, Processing Time 0.018 seconds

Development of Venturi System for Microbubble Generation (미세기포 생성을 위한 벤츄리 시스템 개발)

  • Yun, Jeong Eui;Kim, Joo Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.10
    • /
    • pp.865-871
    • /
    • 2014
  • This study was conducted with the aim of developing a venturi-type air supply system for a microbubble generator. In order to determine the influence of the varying geometry of the venturi tube on the flow characteristics, a computational fluid dynamics (CFD) simulation was performed using the commercial CFD software ANSYS CFX-15. Furthermore, in order to elucidate the effects of variation in major design dimensions such as the air supply hole size, position of holes, and number of holes on the air supply characteristics, two-phase multiflow CFD analysis was performed. The analysis results showed that the starting point of expansion on the venturi tube with 0.75 is the best hole position and that the air supply hole size and the number of holes are linearly proportional to the amount of air.

CFD Analysis for the Design of a Venturi Tube-type Air Bubble Generator with Porous Material Throat (다공성 재질의 목을 가진 벤츄리 관 공기방울 발생장치의 설계를 위한 유동해석)

  • Yun, Jeong-Eui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.10
    • /
    • pp.667-672
    • /
    • 2016
  • The goal of this study was to develop a venturi-type air bubble generator with a porous material throat. Using the two-phase multi-flow CFD analysis for the venturi tube, researchers determined the optimal design of major dimensions, such as the venturi throat length and diameter, in order to control the performance of the air bubble supply through the porous material throat in a venturi tube. Researchers then determined the relationship between the flow rate of supply water and the major design dimensions of the venturi-type air generator for maximizing the performance of the air bubble supply through the porous material throat in a venturi tube.

A study on the improvement of cleaning performance in bag-filter (여과집진기의 탈진 거동 개선에 관한 연구)

  • Hong, Sung-Gil;Kum, Young-Ho;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1571-1578
    • /
    • 2015
  • The cleaning characteristics of pulse air jet type cleaning system which is widely applied in the industries were identified by utilizing the computational fluid dynamics (CFD) and the cleaning performance in modified shape of dedusting unit was compared in this study. The review on each shape of cleaning part showed that the case of installing the nozzle on the blow tube (Case-3) and the case of installing the double intaking tube to the venturi (Case-4 and Case-5) were more excellent than the structure (Case-1). Also, the optimal venturi shape was designed and examined its applicability to the site in a pilot scale plant. A combined system of a blow tube and a venturi proposed by this study turned out to be very effective for concentrating an cleaning air compared to existing systems, such as using only blow tube and combines the blow tube and venturi. In addition, as a result of installing and testing a venturi proposed by this study, the cleaning frequency and cleaning time were much improved compared to a case of using a commercial venturi that is under use at the industrial sites.

A study on the exhaust gas recirculation in a MILD combustion furnace by using a Venturi nozzle (MILD 이용한 배기가스 재순환에 관한 연구)

  • Ha, Ji Soo;Shim, Sung Hoon
    • Journal of Energy Engineering
    • /
    • v.22 no.4
    • /
    • pp.413-419
    • /
    • 2013
  • The present study used the MILD combustor, which has coaxial cylindrical tube. The outside tube of the MILD combustor corresponds to the exhaust gas passage and the inner side tube is the furnace passage. A numerical analysis was accomplished to elucidate the characteristics of exhaust gas entrainment toward the inner furnace with the changes of venturi nozzle geometrical parameters, nozzle position, nozzle gap between high pressure air nozzle and venturi nozzle, and with the change of high pressure nozzle inlet velocity. The entrainment flow rate for the case with the high pressure air nozzle attached at the exhaust gas wall has relatively small change with the change of nozzle gap. That for the case with the high pressure air nozzle exposed to the exhaust gas has monotonically increase with the change of nozzle gap. The flow rate ratio of entrainment flow rate has considerably increase tendency with relatively lower air inlet velocity, on the other hand, that with relatively higher air inlet velocity could be seen relatively small increase.

Experimental Analysis of Flow Induced Vibration Measurement Using Fiber Optic Sensor (광섬유 센서를 이용한 유체유기진동의 실험적 측정 연구)

  • Lee, Jongkil
    • 대한공업교육학회지
    • /
    • v.34 no.1
    • /
    • pp.274-286
    • /
    • 2009
  • Fiber optic sensor is widely used in measuring acoustic and vibration. Especially interferometric sensors are more suitable to measure the acoustic signal. In this paper, a Fabry-Perot interferometric fiber optic sensor was used to measure flow induced vibration. This vibration also measured using an accelerometer, and the data was compared to one other. The venture, nozzle, drop barrel, and rapid expansion in the pipeline are the measuring objects. The flow rate is changed from 50 L/min to 150 L/min and the average flow velocity was about 7 m/s. Based on the experimental results the suggested fiber optic sensor detects flow induced vibration effectively. Therefore, this kind of fiber optic sensor can be applied to the monitoring the flow induced noise and vibration such as pipelines, cables, buildings.

A study on the optimization design of pulse air jet system to improve bag-filter performance (여과집진기의 탈진 성능 향상을 위한 충격 기류 분사 시스템 최적화 설계에 관한 연구)

  • Hong, Sung-Gil;Jung, Yu-Jin;Park, Ki-Woo;Jeong, Moon-Heon;Lim, Ki-Hyuk;Suh, Hye-Min;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3792-3799
    • /
    • 2012
  • The dedusting characteristics of pulse air jet type dedusting system which is widely applied in the industries were identified by utilizing the computational fluid dynamics (CFD) and the dedusting performance in modified shape of dedusting unit was compared in this study. The review on the dedusting air volume, air stream distribution and inflow velocity distribution on each shape of dedusting part showed that the case of installing the nozzle on the blow tube (Case-3) and the case of installing the double intaking tube to the venturi (Case-4 and Case-5) were more excellent than the structure (Case-1) which is widely applied in the field in its amplification effect on the air volume and extension of stream width. The specification of venturi was decided to apply the selected Case-5 for the option of the commercial back filter. It is considered that the dedusting air volume will be maintained in maximum in the case of 50 mm and 90 mm for the diameter of internal and external intaking pipe respectively.

Fluidized Bed Feeding Method of the Particulate Metallic Fuel for a Variable Concentration Quality (유동층 방식의 밀집상과 희박상 거동을 이용한 분말형 금속 연료 정량 공급 방법)

  • Ko, Tae-Ho;Yoon, Woong-Sup
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.422-428
    • /
    • 2011
  • 금속을 청정 에너지원으로 이용하기 위해 분말형 금속연료 연소시스템이 필요하고, 이에 대한 선행연구로 분말을 정량 공급할 수 있는 공급기를 설계 제작하였다. 유동층 방식의 분말 공급에 영향을 미칠 수 있는 변수들을 피스톤 및 벤츄리관이 적용된 공급 방법을 사용하여 통제한 후, 조절 가능한 공급기 내부 압력만을 변수로 하여 중요 성능인 분말 공급량을 직접적인 중량 측정 방법으로 측정하였다. 측정 실험의 결과로부터 연소시스템에 적용할 공급기의 작동 조건을 도출할 수 있었고, 작동 조건에서 벗어난 영역에서 분말 공급기가 가지고 있는 문제점을 확인하였다.

  • PDF

Analysis of Turbulent Gas-Particle Suspension Flows in a Venturi (固體粒子 가 浮上된 벤츄리管 流動 의 解析)

  • 성형진;정명균
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.2
    • /
    • pp.133-140
    • /
    • 1984
  • A "two-fluid" equation model has been applied for predicting gas-solid suspension flows through a Venturi tube. In the "two-fluid"equation model, the bulk motion of the particles is considered as a continuum whose governing equation is obtained by averaging the conservation equations over a volume and expressing the equations in differential forms. Closure of the time-mean equations is achieved by modeling the turbulent correlations with an extended mixing-length theory. Proposed closure model is found to aptly simulate the dependency of the static pressure drop on the particle size, flow rate and the loading ratio.d the loading ratio.

An Experimental Study on the Improvement of Foam Fire-Extinguishing System's Mixing Ratios by Expanding the Cross Sectional Area of the Stock Solution Inhaling Piping (원액흡입배관 단면적 확장에 의한 포 소화설비 혼합비 개선에 관한 실험적 연구)

  • Yun, Ki-Jo;Jang, Kyung-Nam;Baek, Eun-Sun;Park, Bong-Rae;Park, Hee-Joog
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.30-37
    • /
    • 2013
  • The ultimate purpose of the present study is to secure a effective method for foam liquid discharge when the mixing ratio deviates from the permissible range due to a decrease in the bypass flow rate resulting from a decrease in the cross sectional area of the foam liquid piping ranging from the branching header of one foam proportioner to the branching headers of multiple branching foam fire-extinguishing systems in the region for fire extinguishing and then to the standpipe at the lower part of the storage tank when a fire occurred in a combustible tank. To this end, the cause of mixing ratio variations following changes in the flow rates of existing foam fire extinguishing systems was analyzed, methods for compensation for constant mixing ratios were investigated, and it was proved that metering orifice replacements that could expand the cross sectional area of the stock solution inhaling piping was the most effective way for the improvement of form fire extinguishing systems' mixing ratios through foam proportioner venturi, foam chamber orifice, and metering orifice replacement experiments.