• Title/Summary/Keyword: 방사선효과

Search Result 1,833, Processing Time 0.027 seconds

Effect of Selenium on the Thyroid gland Antioxidative Metabolisms in Rat Model by Ionizing Radiation (셀레늄이 전리방사선에 의한 힌쥐 모델에서의 갑상선 항산화계에 미치는 영향)

  • Choi, Hyung-Seok;Choi, Jun-Hyeok;Jung, Do-Young;Kim, Jang-Oh;Shin, Ji-Hye;Min, Byung-In
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.135-142
    • /
    • 2017
  • Selenium (Se), which is natural materials existing was known as an important component of selenoprotein, one of the important proteins responsible for the redox pump of a living body. Selenium was orally administered to Rat and irradiated with 10 Gy of radiation. Then, the thyroid gland was used as a target organ for 1 day, 7 days and 21 days to investigate the radiation protection effect of selenium (Se) through changes of blood components, thyroid hormones (T3, T4), antioxidant enzyme (GPx) activity and thyroid tissue changes. As a result, there was a significant protective effect of hematopoietic immune system(hemoglobin concentration, neutrophil, platelet)(p<0.05). The activity of Glutathione Peroxidase (GPx), the antioxidant enzyme, and the activity of the target organ, thyroid hormone (T3, T4), also showed significant activity changes (p<0.05). In the observation of tissue changes, it was confirmed that there was a protective effect of thyroid cell damage which caused the cell necrosis by radiation treatment. Therefore, it is considered that selenium(Se) can be utilized as a radiation defense agent by inducing immunogenic activity effect of a living body.

The Efficacy of Induction Chemotherapy in Stage III Non-Small Cell Lung Cancer (제 3기 비소세포 폐암에서 유도 화학 요법의 효과)

  • Cho Heung Lae;Joo Young Don;Sohn Seung Chang;Sohn Chang Hak
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.283-289
    • /
    • 1998
  • Purpose : This study was performed to analyze the efficacy of induction chemotherapy fellowed by radiation therapy in locally advanced non-small cell lung cancer Materials and Methods : Eighty patients with locally advanced non-small cell lung cancer treated from 1989 to 1995 at Pusan Paik hospital were analyzed retrospectively. Twenty-one patients were treated with induction chemotherapy followed by radiation therapy and Fifty-nine Patients were treated with radiation therapy alone. Chemotherapy regimen consisted of cisplatin-based combination (2 or 3 drugs). All patients were treated by Co-60 or 6 MV linear accelerators. Radiation dose ranged from 50 Gy to 80 Gy (median 64.8 Gy). We evaluated response rate, survival rate, and pattern of failure in both treatment groups. Results : Overall response rate in induction chemotherapy group and radiotherapy alone group were 48% and 45%, respectively. Of the 80 patients, 46 patients were evaluable for pattern of failure. Initial failure pattern in induction chemotherapy group was as follows: 8 (67%) at locoregional, 4 (33) in distant metastasis. Radiation alone group was 21 (71%) and 5 (29%), respectively. Results showed no difference of distant failure between induction chemotherapy group and radiation alone group. The 1 and 2 year survival rate in induction chemotherapy group were 43% and 14%, respectively and in radiotherapy alone group, 31% and 7%, respectively (p=0.135). Conclusion : In stage III non-small cell lung cancer, induction chemotherapy and radiation therapy showed increased tendency in survival with no statistical significance Induction chemotherapy seems to have no effect of decreasing distant failure and no survival advantage compared with radiotherapy alone.

  • PDF

Immune Cell Activation and Co-X-irradiation Effect of Eleutherococcus senticosus Maxim Root (가시오갈피 뿌리의 면역세포 활성 및 방사선 병용효과)

  • Kwon, Hyoung-Cheol;Park, Jeong-Seob;Choi, Dong-Seong
    • Radiation Oncology Journal
    • /
    • v.25 no.3
    • /
    • pp.185-191
    • /
    • 2007
  • Purpose: This study was performed to investigate the effects of immune cell activation and the antitumor effect for the combination of treatment with X-irradiation and E/eutherococcus senticosus Maxim Root (ESMR) on mouse tumor cells. Materials and Methods: ESMR (250g) was extracted with 80% methanol, concentrated under decompression and lyophilized. To determine whether ESMR is able to activate the immune cells or not, the proliferation of splenocytes in vitro and the number of B cells and T cells in splenic lymphocytes in ESMR-pretreated mice were evaluated. X-irradiation was given to the mouse fibrosarcoma tumor cells (FSa II) by 250 kv X-irradiation machine. The cytotoxicity of ESMR was evaluated from its ability to reduce the clonogenecity of FSa II cells. In X-irradiation alone group, each 2, 4, 6 and 8 Gy was given to FSa II cells. In X-irradiation with ESMR group, 0.2 mg/ml of ESMR was exposed to FSa II cells for 1 hour before X-irradiation. Results: The proliferation of cultured mouse splenocytes and thymocytes were enhanced by the addition of ESMR in vitro. The number of B cells and T cells in mouse splenic lymphocytes was significantly increased in ESMR pretreated mice in vivo. In FSa II cells that received a combination of 0.2 mg/ml of ESMR with X-irradiation exposure, the survival fraction with a dose of 2, 4 and 6 Gy was $0.39{\pm}0.005$, $0.22{\pm}0.005$ and $0.06{\pm}0.007$, respectively. For FSa II cells treated with X-irradiation alone, the survival fraction with a dose of 2, 4 and 6 Gy was $0.76{\pm}0.02$, $0.47{\pm}0.008$ and $0.37{\pm}0.01$. The difference in the survival fraction of the mouse FSa II cells treated with and without ESMR was statistically significant (p<0.05). Conclusion: Treatment with ESMR increased cell viability of mouse splenocytes in vitro and especially the subpopulation of B cells and T cells in splenocytes in ESMR-pretreated mice. However, treatment with ESMR did not increase the level of Th and Tc subpopulations in the thymocytes. Treatment with the combination of ESMR and X-irradiation was more cytotoxic to mouse tumor cells than treatment with X-irradiation alone; this finding was statistically significant.

The Effect of Irradiation and Cis-diamminedichloroplatinum(II) in the Rat Brain : Analysis of Histopathology at 3 and 6 Months after Treatment (횐쥐 뇌에 방사선조사와 Cis-diamminedichloroplatinum(II)의 효과 : 치료 후 3개월과 6개월에서의 조직학적분석)

  • Lee Kyung-Ja;Chang Seung-Hee;Koo Heasoo
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.125-138
    • /
    • 1998
  • Purpose : To evaluate the late effect(3 and 6 months) of cis-diarnrninedichlo-roplatinum(II)(cisplatin) on the radiation brain damage when the cisplatin was intraperitoneally infused immediately after whole brain irradiation in the rats. Materials and Methods : The histolopathological findings of the brain were examined in rat brains at 3 and 6 months after the treatment. The rats were irradiated(20 or 22.5 Gy, RT) or cisplatin was injected intraperitoneally(2,4, or 8mg/kg, CT) and in combined treatment group, cisplatin(2mg/kg) was injected immediately after irradiation(20 or 22.5 Gr). Histopathological examination was done mostly in irradiation or cisplatin alone groups, because the rats in combined group died during experimental period except 2 rats. Results : The rats treated with cisplatin showed marked epithelial vacuolation with perivascular edema and vascular dilatation in choroid plexus at 3 months as well as multifocal necrosis involving fimbria and cerebellar hemispheres at 3 and 6 months. The changes were more prominent in rats with 2mg/kg injection compared to rats with 8mg/kg injection. The rats with RT and combined CT and RT showed characteristic delayed irradiation effects such as focal coagulation necrosis and vascular changes, which were more marked than previous reports Prominent perivascular and leptomenin-geal astrocytic Proliferation was well documented by anti-GFAP antibody. Cisplatin treatment did not enhance the effect of radiation-induced changes of blood vessels and astrocytic proliferation. Conclusion : The focal necrosis was the most consistently noted finding in this study, it suggested the possibility to use this as an evaluation factor for combined effects of RT and cisplatin.

  • PDF

A Study on the Evaluation of Radiation Safety in Opened-Ceiling-Facilities for Radiography Testing (천장 개방형 RT 사용시설의 방사선 안전성 평가 연구)

  • Sung-Hoe, Heo;Won-Seok, Park;Seung-Uk, Heo;Byung-In, Min
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.741-749
    • /
    • 2022
  • Radiography-Testing that verify the quality of welding structures without destruction are overwhelmingly used in industries, but many safety precautions are required as radiation is used. The workers for Radiography-Testing perform the inspection by moving the Iridium-192 radiation source embedded in the transport container of the gamma-ray irradiator within or outside the facility. The general facility is completely blocked about radiation from the outside with thick concrete, but if it is difficult for worker to handle object of inspection, facilities ceiling can be opened. A general facility may be constructed using a theoretical dose evaluation method because all exterior facilities are blocked, but if the ceiling is open, it is not appropriate to evaluate radiation safety with a simple theoretical calculation method due to the skyshine effect. Therefore, in this study, the radiation safety of the facility was evaluated in the actual field through an ion chamber survey-meter and an accumulated dose-meter called as OSLD, and the actual evaluation environment was modeled and evaluated using the Monte Carlo simulation code as FLUKA. According to the direction of the irradiation, the radiation dose at the facility boundary was difficult to meet the standards set by the regulatory authority, and radiation safety could be secured through additional methods. In addition, it was confirmed that the simulation results using the Iridium-192 source were valid evaluation with the actual measured results.

A Synthesis of Iron Oxide Based and Gadolinium Oxide Based Radiosensitizer for the Therapeutic Enhancement of Proton Beam Cancer (양성자 빔 암치료효과 개선을 위한 산화철 및 산화가돌리늄 나노입자 기반의 방사선증감제 합성)

  • Kang, Bo Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.325-332
    • /
    • 2014
  • Metallic nanoparticles have attractive properties in biomedical applications such as diagnostics and therapeutics. Cross linked dextran coated iron oxide nanoparticles (SPIONs) and silica coated gadolinium oxide nanoparticles (SPGONs) have been synthesized as a radiosensitizer in the proton beam cancer therapy. The dextran and silicaused for the protective moieties on the SPIONs and SPGONs respectively. Size distributions of synthesized nanoparticles were confirmed 3~5 nm for SPIONs and 30~100 nm for SPGONs by transmission electron microscope (TEM). Cell survival fraction measurement and Western blot assay were performed to evaluate the radiosensitization effects of synthesized radiosensitizer. The calculated radiosensitization of SPIONs and SPGONs at 90 % cell death from the measured cell survival curves were 1.23 and 1.03 respectively. Western blotting results also show the same consistent results that the amount of released cytochrome c from mitochondria was considerably increased for the cancer cells taken up SPIONs.

Intracavitary Irradiation of Locally Advanced Recurrent Adenocarcinoma of Rectum Along the Fistula Tract (누도를 따라 재발한 직장암의 강내조사)

  • Kim Kyeong Ae;Kim Sung Kyu;Shin Sei One;Kim Myung Se;Song Sun Kyuo;Shim Min Chul;Kwun Koing Bo
    • Radiation Oncology Journal
    • /
    • v.6 no.2
    • /
    • pp.289-293
    • /
    • 1988
  • Radiation therapy has been used as adjuvant therapy or primary treatment for inoperable, remnant or recurrent cancer. Many authors reported good palliation effect by external irradiation or interstitial therapy, but the report of intracavitary irradiation for recurrent, inoperable rectal cancer is very rare. We experienced a case of recurrent adenocarcinoma of rectum along fistula tract after laparotomy and postoperative radiotherapy who achieved very good palliation by intracavitary irradiation. Even though we have only good palliation without impressive survival improvement in this case, we hope that this technique may achieve good local control In other similar patients.

  • PDF

Evaluation of the Effectiveness of 3D Printing Shielding Devices using Monte Carlo Simulation in Plain Radiography (일반영상 검사 시 몬테칼로 시뮬레이션을 이용한 3D 프린팅 차폐기구의 효용성 평가)

  • Cho, Yong In;Kim, Jung Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.303-311
    • /
    • 2020
  • Scattering-ray generated during plain radiography can cause secondary exposure to organs and tissues other than the target area. Currently, Shielding devices used to reduce radiation exposure are mostly used for radiation protection of workers, and radiation protection of patients is rarely performed. Therefore, this study intends to evaluate the organ dose by scattered-rays and the effectiveness 3D printing materials as a radiation shielding device during plain radiography through simulation. As a result, the absorbed dose for each organ at the time of examination showed a high effect due to the secondary scattering-ray as the distance from the source was close and the organ closer to the skin surface. The dose reduction effect due to the use of 3D printing shielding devices to protect this showed a higher shielding effect in the case of mixed printing materials compared to plastics.

Radiation Resistance Evaluation of Thin Film Transistors (박막트랜지스터의 방사선 내구성 평가)

  • Seung Ik Jun;Bong Goo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.625-631
    • /
    • 2023
  • The important requirement of industrial dynamic X-ray detector operating under high tube voltage up to 450 kVp for 24 hours and 7 days is to obtain significantly high radiation resistance. This study presents the radiation resistance characteristics of various thin film transistors (TFTs) with a-Si, poly-Si and IGZO semiconducting layers. IGZO TFT offering dozens of times higher field effect mobility than a-Si TFT was processed with highly hydrogenated plasma in between IGZO semiconducting layer and inter-layered dielectric. The hydrogenated IGZO TFT showed most sustainable radiation resistance up to 10,000Gy accumulated, thus, concluded that it is a sole switching device in X-ray imaging sensor offering dynamic X-ray imaging at high frame rate under extremely severe radiation environment such as automated X-ray inspection.

Radioprotective Effect of Post-treatment with Rutin on γ-Irradiation-induced Cellular Damage in Mice (감마선 조사로 유도된 세포 손상 마우스에서 루틴 투여 후의 방사선 방호 효과)

  • Kang, Jung Ae;Yoon, Seon Hye;Rho, Jong Kook;Choi, Dae Seong;Jang, Beom-Su;Park, Sang Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.3
    • /
    • pp.388-393
    • /
    • 2015
  • This study aimed to investigate the therapeutic effect of rutin against whole-body ${\gamma}$-irradiation in BALB/c mice. BALB/c mice were randomly divided into four groups and exposed to 6 Gy ${\gamma}$-irradiation. One hour later, mice were orally administered rutin (50 and 100 mg/kg) for seven consecutive days. ${\gamma}$-Irradiation (6 Gy) resulted in cellular damage as manifested by elevated levels of plasma hepatic marker enzymes and lipid peroxidation in liver tissue, accompanied with decreased spleen and thymus indices, and white blood cell count. In addition, ${\gamma}$-irradiation significantly decreased the levels of antioxidant enzymes such as superoxide dismutase, glutathione peroxidase and catalase. Rutin treatment significantly protected against ${\gamma}$-irradiation-induced cellular damage, which was evident by the improvement in the status of most of the investigated parameters. Therefore, rutin has beneficial effects against radiation-induced damage.