• 제목/요약/키워드: 방사선시험

Search Result 436, Processing Time 0.035 seconds

The Antifungal Microorganisms to Mycogone perniciosa Magn. in Cultivated Mushroom, Agaricus bisporus (Lang) Sing (양송이 마이코곤병(Mycogone perniciosa Magn.)의 항균성 미생물에 관한 연구)

  • Jhune, C.S.;Cha, D.Y.;You, C.H.
    • The Korean Journal of Mycology
    • /
    • v.18 no.2
    • /
    • pp.96-101
    • /
    • 1990
  • This study was conducted to select the promising antifungal microoganisms for biological control of wet bubble, Mycogone perniciosa. Ninty one isolates of fungi, 342 isolates of bacteria, and 556 actinomycetes were isolated from mushroom composts and soils, were subjected to primary screening test on agar medium base for their antimicrobial spectra. Among them, 12 bacteria and 71 actinomycetes were selected. Among the antibiotic producing microoganisms, 5 cultures were selected on the basis their antibiotic activities on casing soil with Benlate nontolerence M. perniciosa. Finally, AJ-117, AJ-136 and AK-139 were selected as microoganism with antifungal activity against two strains of M. perniciosa.

  • PDF

In-Site Application of Heavyweight Concrete for Radiation Shielding (방사선 차폐용 중량콘크리트의 현장 적용성)

  • Yang, Seung-Kyu;Um, Tae-Sun;Lee, Jong-Ryul;Kim, Yong-Ho;Wu, Sang-Ik;Kim, Tae-Bong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.577-580
    • /
    • 2008
  • This paper was discussed about in-site application of heavyweight(or high density) concrete. Heavyweight concrete was placed with the method of conventional. Placement of conventionally mixed heavyweight concrete is subject to the same considerations of quality control as normal density concrete, except that it is far more susceptible to variations in quality due to improper handling. It is particularly subject to segregation during placement. Segregation of heavyweight concrete results not only in variation of strength but, far more importantly, in variation in density that are intolerable for work this type, since this adversely affects shielding properties. Heavyweight concrete materials and heavyweight concrete should be sampled and tested prior to and during construction to insure conformance with applicable standards and specifications.

  • PDF

CMOS Logic Design and Fabrication for Analyzing the Effect of Transient Radiation Damage (과도 방사선 피해 영향 분석을 위한 CMOS 논리 소자 설계 및 제작)

  • Jeong, Sang-Hun;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.880-883
    • /
    • 2012
  • In this paper, CMOS logic device, the INVERTER, NAND, NOR were designed and fabricated using 0.18um CMOS process for analyzing the effect of transient radiation damage. Fabricated logic devices were measured by applying a 1kHz input at 1.8V supply. As a result, the current consumption of less than 70uA and Rising time, Falling time was within a 4us. Experimental results transmission delays occurred when using a 50M cable for pulse radiation experiments.

  • PDF

DataBase system construction for the study of radiation hardened electronic devices using pulse radiation (펄스방사선을 이용한 내방사선 연구 DB 구축)

  • Ko, Seong-Gon;Oh, Seung-Chan;Hwang, Young-Gwan;Jeong, Sang-Hun;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.778-781
    • /
    • 2012
  • The electronic element the damage occurs with radiation being bombed. In order applies in the artificial satellite or the space ship therefore from the within has radiation introspection the use of the radiation electronic element is essential. Transient radiation tests performed for the first time in Korea evaluation data database (DB) was constructed to. Web-based materials in the DB is designed to be able to search and update, and existing foreign (NASA, ESA) for a total of 695 species, including public sources of data has been entered. Search DB than the existing foreign DB is an efficient and practical.

  • PDF

Pulse Radiation Dose Measurement using the Peak Detector (Peak Detector를 이용한 펄스방사선 선량 측정)

  • Jeong, Sang-hun;Lee, Nam-ho;Oh, Seong-chan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.1020-1022
    • /
    • 2013
  • In this paper, proposed peak detector for the measurement of pulse radiation dose. The speed of the pulse radiation signal is the between a few ns and tens ns. Therefore, it is difficult to measure peak voltage. Peak Detector maintains the peak voltage generated from the sensor for a few ms and the converted signals can be easily measured using the ADC. The peak detector simulation results peak value remained of more than 1ms. Pulse radiation irradiation test results, a dose of $1.95{\times}10^6rad/s$ was measured.

  • PDF

The Analysis of Radiation Effects of Single-Mode Optical Fibers Using Fiber Bragg Grating Sensors (광섬유 브래그 격자 센서를 이용한 단일모드 광섬유의 방사선 영향 분석)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu;Kim, Young-woong;Han, Won-Taek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.732-735
    • /
    • 2013
  • In this study, we are measured gamma-ray induced loss on single-mode (SM) fibers from a total of four different manufactures. The $Co^{60}$ gamma-ray source was used in this test. The gamma-ray is irradiated for 2 hours at the dose rate of 0.6 kGy/hr, 1.2 kGy/hr, 2.4 kGy/hr. In test results, We clearly confirm the dose rate effect in different fiber types and evaluate the radiation sensitivity by the change of the radiation-induced loss.

  • PDF

The analysis on the Pulsed radiation effect for semiconductor unit devices (반도체 단위소자의 펄스방사선 영향분석)

  • Jeong, Sang-hun;Lee, Nam-ho;Lee, Min-woong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.775-777
    • /
    • 2016
  • In this paper presents an analysis of pulsed radiation effects of unit devices. Unit devices are the nMOSFET, pMOSFET, NPN Transistor and those fabricated by the 0.18um CMOS process. Pulsed radiation test results in nMOSFET, the photocurrent of tens nA was generated in $2.07{\times}10^8rad(si)/s$. For the pMOSFET, a photocurrent generation was not observed in $3{\times}10^8rad(si)/s$. For the NPN transistor, the photocurrent was generated with about 1uA. Therefore, the MOSFET must be used than BJT transistor when radhard IC design.

  • PDF

Testing and Analysis of Tube Voltage and Tube Current in The Radiation Generator for Mammography (유방촬영용 방사선발생장치의 관전압과 관전류 시험 분석)

  • Jung, Hong-Ryang;Hong, Dong-Hee;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Breast shooting performance management and quality control of the generator is applied to the amount of current IEC(International Electrotechnical Commission) 60601-2-45 tube voltage and tube current are based on standards that were proposed in the analysis of the test results were as follows. Tube voltage according to the value of the standard deviation by year of manufacture from 2001 to 2010 as a 42-3.15 showed the most significant, according to the year of manufacture by tube amperage value of the standard deviation to 6.38 in the pre-2000 showed the most significant, manufactured after 2011 the standard deviation of the devices, the PAE(Percent Average Error) was relatively low. This latest generation device was manufactured in the breast of the tube voltage and tube diagnosed shooting the correct amount of current to maintain the performance that can be seen. The results of this study as the basis for radiography diagnosed breast caused by using the device's performance and maintain quality control, so the current Food and Drug Administration "about the safety of diagnostic radiation generator rule" specified in the test cycle during three years of self-inspection radiation on a radiation generating device ensure safety and performance of the device using a coherent X-ray(constancy) by two ultimately able to keep the radiation dose to the public to reduce the expected effect is expected.

Safety Evaluation of a Shipping Capsule for Special Form Radioisotope (특수형 방사성 동위원소 운반캡슐의 안전성 평가)

  • Lee, Ju-Chan;Seo, Ki-Seog;Ku, Jeong-Hoe;Bang, Kyoung-Sik;Han, Hyon-Soo;Park, Seong-Won
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.1
    • /
    • pp.35-43
    • /
    • 2001
  • All of sealing capsules to transport a special form radioactive material should be designed and fabricated in accordance with the design criteria prescribed in IAEA standards and domestic regulations. The objective of this study is to demonstrate the safety of a shipping capsule for $^{192}Ir$ special form radioisotope which produced in the HANARO. The safety tests were carried out for the impact, percussion, bending and heat test conditions. And leakage tests were carried out before and after the each test. Also, the safety analyses wert performed using computer codes in order to verify the test results. The capsule showed slight scratches and deformation, and maintained its structural and thermal integrities in all tests without any severe damage or melting. It also met the allowable limits of leakage rate after each test. Therefore, it has been verified that the capsule was designed and fabricated to meet all requirements for the special form.

  • PDF