• Title/Summary/Keyword: 바이패스

Search Result 258, Processing Time 0.028 seconds

Characteristics of Temperature Control by Hot-gas Bypass Flow Rate on Industrial Water Cooler (핫가스 바이패스 유량에 따른 산업용 냉각기의 온도제어 특성)

  • Baek, Seung-Moon;Choi, Jun-Hyuk;Byun, Jong-Yeong;Moon, Choon-Geun;Lee, Ho-Saeng;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1129-1136
    • /
    • 2009
  • The paper presents the performance characteristics for a cooling system using EEV. The water cooler was used to reduce thermal deformation and contraction due to high speed of machine tools and the EEV was used for capacity control for water cooler. The apparatus was designed for hot-gas bypass system which a hot-gas can flows from outlet of compressor to the inlet of evaporator. This experiment is the intermediary study for precise temperature control through PID control. The results show that the evaporator pressure increased and refrigeration capacity decreased as the EEV opening step of hot-gas bypass increased. These results can be used as basic data for the design of effective water cooler.

Development of a High Pressure Turbine Bypass System Pressure Control Model for Power Plant Simulator (발전소 시뮬레이터를 위한 고압 터빈 바이패스 압력 제어 모델 개발)

  • Byun, Seung-Hyun;Lee, Joo-Hyun;Lim, Ick-Hun
    • Journal of the Korea Society for Simulation
    • /
    • v.20 no.4
    • /
    • pp.49-58
    • /
    • 2011
  • It is required that a developed control system should be verified using simulator in terms of functionality and reliability prior to application to a power plant that is a very critical facility in the industry. In this paper, the control model for turbine bypass system was developed for power plant simulator. In order to develop the control model for turbine bypass system, the tool that can be used to implement turbine bypass control logic was developed based on the turbine bypass control system manual. The developed tool was merged into the simulator development environment. The functionality of the developed tool was verified via the simulation based on the each function block specification. The HP turbine bypass pressure control logic was implemented using the developed tool and was integrated with process models and other control models such as boiler control model, turbine control model and boiler feed water pump turbine control model for 500 MW korean standard type fossil power plant. Finally, the validity of the developed control model was shown via simulation result under the integrated simulation environment.

A 2.4-GHz CMOS Power Amplifier with a Bypass Structure Using Cascode Driver Stage to Improve Efficiency (효율 개선을 위해 캐스코드 구동 증폭단을 활용한 바이패스 구조의 2.4-GHz CMOS 전력 증폭기)

  • Jang, Joseph;Yoo, Jinho;Lee, Milim;Park, Changkun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.8
    • /
    • pp.966-974
    • /
    • 2019
  • In this study, we propose a CMOS power amplifier (PA) using a bypass technique to enhance the efficiency in the low-power region. For the bypass structure, the common-gate (CG) transistor of the cascode structure of the driver stage is divided in two parallel branches. One of the CG transistors is designed to drive the power stage for high-power mode. The other CG transistor is designed to bypass the power stage for low-power mode. Owing to a turning-off of the power stage, the power consumption is decreased in low-power mode. The measured maximum output power is 20.35 dBm with a power added efficiency of 12.10%. At a measured output power of 11.52 dBm, the PAE is improved from 1.90% to 7.00% by bypassing the power stage. Based on the measurement results, we verified the functionality of the proposed bypass structure.

The Effects of Hypercapnia and High Flow on Cerebral Metabolism During Cardiopulmonary Bypass (심폐바이패스 시 고탄산분압과 고관류법이 뇌대사에 미치는 영향)

  • 강도균;최석철;윤영철;최국렬;정신현;황윤호;조광현
    • Journal of Chest Surgery
    • /
    • v.36 no.7
    • /
    • pp.472-482
    • /
    • 2003
  • Recent studies have demonstrated that cerebral desaturation during rewarming period of CPB was associated with postoperative neurologic dysfunction. The prevention of cerebral desaturation during CPB may reduce the incidences of neurologic and neuropsychological complications. The present study was prospectively undertaken to compare the clinical effects between two strategies (hypercapnic CPB and high flow CPB) to prevent cerebral desaturation for establishing a proper CPB technique. Material and Method: Thirty-six adult patients scheduled for elective cardiac surgery were randomized into either hypercapnic (Pa$CO_2$ 45~50mmHg, n=18) or high flow group (flow rate 2.75 L/ $m^2$/min and Pa$CO_2$ 35~40mmHg, n=18) during rewarming period of CPB. In each patient, middle cerebral artery blood flow velocity ( $V_{MCA}$), cerebral arteriovenous oxygen content difference (C(a-v) $O_2$), modified cerebral metabolic rate for oxygen (MCMR $O_2$), cerebral oxygen transport rate ( $T_{E}$ $O_2$), incidence of cerebral desaturation (internal jugular bulb blood oxygen saturation $\leq$ 50%), increased rate of S-100 $\beta$ concentration, and arterial and internal jugular bulb blood gas were measured during the five phases of the operation; Pre-CPB, CPB-10 min (steady-state CPB, nasopharyngeal temperature 29~3$0^{\circ}C$), Rewarm-1 (rewarming phase, nasopharyngeal temperature 33$^{\circ}C$), Rewarm-2 (nasopharyngeal temperature 37$^{\circ}C$), and CPB-off. Incidence of postoperative delirium and duration were assessed in all patients. All variables were compared between the two groups. Result: $V_{MCA}$ (157.88$\pm$10.87 vs 120.00$\pm$6.18%, p=0.006), internal jugular bulb $O_2$ saturation (68.01$\pm$2.75 vs 61.28$\pm$2.87%, p=0.03) and $O_2$ tension (41.01$\pm$2.25 vs 32.02$\pm$ 1,67 mmHg, p=0.03), and $T_{E}$ $O_2$(110.84$\pm$7.41 vs 81.15$\pm$8.11%, p=0.003) at rewarming periods were higher in the hypercapnic group than in the high flow group. C(a-v) $O_2$ (4.0$\pm$0.30 vs 4.84$\pm$0.38 mg/dL, p=0.04), COE (0.36$\pm$0.03 vs 0.42$\pm$0.03, p=0.04), increased rate of S- 100$\beta$ (391.67$\pm$23.40 vs 940.0$\pm$17.02%, p=0.003), and incidence of cerebral desaturation (2 vs 4 patients, p=0.04) at rewarming periods, and duration of postoperative delirium (18 vs 34 hr, p=0.02) were low in the hypercapnic group compared to the high flow group. Conclusion: These results indicate that hypercapnic CPB may provide relatively diminished cerebral injury and beneficial effects for cerebral metabolism relatively compared to high flow CPB.low CPB.

Midterm Patency after Off-Pump Coronary Artery Bypass Grafting (심폐바이패스없이 심박동상태에서 시행한 관상동맥우회술후 중기 개통율)

  • Lee, Cheul;Chang, Woo-Ik;Lim, Cheong;Kim, Ki-Bong;Chae, In-Ho;Oh, Byung-Hee;Lee, Myoung-Mook;Park, Young-Bae
    • Journal of Chest Surgery
    • /
    • v.34 no.8
    • /
    • pp.583-590
    • /
    • 2001
  • The aim of this study was to compare one-year graft patency after coronary artery bypass grafting without cardiopulmonary bypass(OPCAB) with that of conventional CABG and that of on-pump beating CABG, and to demonstrate any differences in patency of various conduits among the three groups. Material and Method: We analyzed the results of OPCAB cases(group I; n=122) compared with those of conventional CABG cases(group II; n=65) and those of on-pump beating CABG cases(group III; n=19). In group I, coronary angiography(CAG) was performed immediately postoperatively and 1 year after surgery. In group II and III, CAG was performed 1 year after surgery. Graft patency was graded as grade A(excellent), grade B(fair), or grade O(occluded). Result: The average number of distal anastomoses in groups I, II, and II were 3.1$\pm$1.1, 3.7$\pm$0.9, and 3.6$\pm$0.9, respectively. In group I, postoperative CAG was performed in 92%(112/122) of patients before discharge. The patency rate(grade A+B) was 96.4$(162/168) for arterial grafts, and 85.6%(160/187) for saphenous vein grafts(SVG). One-year follow-up CAG was performed in 74%(90/122) of patients. The patency rate was 97.8%(132/135) for arterial grafts, and 67.9%(106/156) for SVG. In group II, one-year follow-up CAG was performed in 65%(42/65) of patients. The patency rate(grade A+B) was 93.5%(43/46) for arterial grafts, and 86.8%(33/38) for SVG. Conclusion: Our results demonstrated that the patency rate of SVG after OPCAB was significantly lower than that of arterial grafts in the early postoperative CAG(p<0.001), and was also significantly lower than those of SVG of group II(p<0.001) and group III(p<0.01) in the postoperative one-year CAG, although there was no significant difference is one-year patency of arterial grafts among the three groups. Our data suggest that a specific perioperative anticoagulant therapy may be advisable in patients undergoing OPCAB with SVG.

  • PDF

Digital Phase-Locked Loop(DPLL) Technique for UPS (무정전 전원장치용 디지털 위상동기화 기법)

  • 김제홍;최재호
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.3
    • /
    • pp.106-113
    • /
    • 1997
  • In uninterruptible power supply(UPS), a high speed phase control is usually required to compensate transients in the output voltage at the instant of transfer from the ac line to the inverter when the ac line fails or backs to the ac line in case of the inverter fails. To overcome this problem, this paper pre¬sents the closed digital phase-locked loop(DPLL) techniques designed by full software with TMS320C31 digital signal processor and describes the functional operation of the proposed DPLL. Fi¬nally, the performance of the proposed DPLL is shown and discussed through simulation and experiment.

  • PDF

An Experimental Study on the Performance Characteristics of Hot-gas and Liquid Bypass Heat Pump Systems for Capacity Modulation (고온가스 및 액체 바이패스 적용 용량가변 히트펌프의 성능특성에 관한 실험적 연구)

  • Ahn, Jae Hwan;Joo, Youngju;Yoon, Won Jae;Kang, Hoon;Kim, Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.3
    • /
    • pp.137-142
    • /
    • 2013
  • A small air-conditioner or chiller for a constant temperature bath normally uses a constant speed compressor. The constant speed compressor is relatively inexpensive, but it uses on/off control for capacity modulation. The on/off control has several disadvantages, specifically energy loss and large temperature fluctuation. Continuous operation with a bypass system can be an alternative to on/off control, for capacity modulation. In this study, a heat pump system having a hot-gas bypass and a liquid bypass was adopted. The performance of the bypass-type heat pump was measured, by varying the bypass valve opening. The differences of the COP between the hot-gas bypass and the liquid bypass, in the cooling and heating operations, were within 2% and 1%, respectively. The liquid bypass showed a wider range of capacity control in the cooling operation but the hot-gas bypass showed a wider range of capacity control in the heating operation.

Redo CABG Through a Transabdominal Approach - A Case Report - (경복부 접근법을 통한 관상동맥우회술의 재수술 - 1 례 보고 -)

  • 김홍관;김기봉
    • Journal of Chest Surgery
    • /
    • v.35 no.7
    • /
    • pp.553-555
    • /
    • 2002
  • Transabdominal approach in redo coronary artery bypass grafting(CABG) may avoid the risk related to repeat sternotomy. Redo CABG using this approach can be performed safely in selected cases. We report a case of redo off-pump CABG through a transabdominal approach in a 59-year-old woman with recurrent unstable angina after a previous CABG. Through a curvilinear epigastric incision, right gastroepiploic artery(RGEA) was harvested as a graft, and the RGEA-to-right coronary artery anastomosis was performed on the beating heart. A 1-day postoperative angiographic study showed the patent RGEA graft, and she was discharged on postoperative 4th day without any complication.

Off-pump Reoperative Coronary Artery Bypass by Thoracotomy and Laparotomy -A case report - (개흉술과 복부 절개술을 통한 심폐바이패스를 이용하지 않은 관상동맥 재수술 - 1예 보고 -)

  • Kim Jeong-Won;Hahm Shee-Young;Je Hyoung-Gon;Cho Won-Chul;Song Meong-Gun
    • Journal of Chest Surgery
    • /
    • v.39 no.9 s.266
    • /
    • pp.710-713
    • /
    • 2006
  • The incidence of reoperative coronary artery bypass grafting (CABG) has increased because of the rise in the number of patients who have undergone initial CABG. In addition, recent technological advances have resulted in widespread application of off pump coronary artery bypass (OPCAB). We report a case of redo OPCAB through thoracotomy and small laparotomy in 76-year-old man with recurrent unstable angina.

Arterio-Venous Line Connection for Effective Intracardiac Deairing after Open Heart Surgery (개심술 후 저류공기의 효과적인 제거를 위한 동정맥도관의 설치)

  • 정성운;김종원;박준호
    • Journal of Chest Surgery
    • /
    • v.36 no.11
    • /
    • pp.834-838
    • /
    • 2003
  • Background: Deairing from the heart after open heart surgery(cardiopulmonary bypass) is a very important procedure. Artificial arteriovenous fistula was used to remove air, and the efficiency was evaluated by transesophageal echocardiography. Material and Method: Just before termination of cardiopulmonary bypass, a standard pressure transducer line is connected between the stopcocks of the connections in the arterial and venous circuits, creating a small controlled arteriovenous fistula between the arterial and venous cannulas. The degree of intracardiac air and air removal time were evaluated either by transesophageal echocardiography or direct vision of pressure transducer line. Result: By simple procedure, cardiopulmonary time was shortened and air clearing can be confirmed using echocardiography in a few minutes. Conclusion: Creation of arteriovenous fistula using small connecting line between aortic and venous cannula is a very simple and effective method of deairing and preventing of air embolism after open heart surgery.