• Title/Summary/Keyword: 물리적 등가

Search Result 102, Processing Time 0.036 seconds

A study on the Effectivness of Hand-made Paraffin Thyroid Phantom (Paraffin을 이용한 Thyroid Phantom제작에 따른 유용성에 관한 연구)

  • Park, Soung-Ock;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.237-243
    • /
    • 2007
  • Phantoms are very necessary for quality assurance of radio nuclides imaging systems to maintain standards and to ensure reproducibility of test. General quality assurance and instrument quality control are essential in every hospital. The human tissue equivalent materials are aluminum, areryl, water and epoxy..etc. It is very important to select optimum equivalant materials for a phantoms in QC. Especially, paraffin is very similar with human soft tissue in X or Gamma-ray physical characteristics and easy to buy with economically. We made a paraffin thyroid phantom and compare with thyroid areryl phantom, also used commercially in practice. Two small size cold spots(3 and 6 mm diameter) and a hot spot(3 mm diameter) embeded in paraffin phantom. And imaged with $^{99m}TcO_4$ by camera for analysis about spatial resolution and noise at the hot and cold spots. We got some results as below : 1. No difference in counting rate and noise between both arcryl and paraffin thyroid phantoms. 2. The best spatial resolution can be seen 6 cm distance between pinhole collimator and thyroid phantoms(arcryl and paraffin). 3. More optimal spatial resolution could acquired in paraffin thyroid phantom. Paraffin is very similar with human soft tissue in atomic number, density and relative absorbtion function, and can be shaped easily what we wanted. So we can recommendation paraffin as quality assurance phantom because its usefulness, economical benefit and purchasability.

  • PDF

Impedance Calculation of Power Distribution Networks for High-Speed DRAM Module Design (고속DRAM모듈 설계에 대한 전원평면의 임피던스계산)

  • Lee, Dong-Ju;Younggap You
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.3
    • /
    • pp.49-60
    • /
    • 2002
  • A systematic design approach for Power distribution network (PDN) is presented aiming at applications to DRAM module designs. Three main stages are comprised in this design approach: modeling and simulation of a PDN based on a two-dimensional transmission line structure employing a partial element equivalent circuit (PEEC); verification of the simulation results through comparison to measured values; and design space scanning with PDN parameters. Impedance characteristics for do-coupling capacitors are analyzed to devise an effective way to stabilize power and ground plane Performance within a target level of disturbances. Self-impedance and transfer-impedance are studied in terms of distance between circuit features and the size of do-coupling capacitors. A simple equation has been derived to find the do-coupling capacitance values yielding impedance lower than design target, and thereby reducing the overall computation time. The effectiveness of the design methodology has been demonstrated using a DRAM module with discrete do-coupling capacitors and a strip structure.

Comparison of Distribution following Treatment Method in Total Body Irradiation (전신방사선조사에서 치료방법에 따른 선량분포 특성 비교)

  • 김성규;김명세;신세원
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.21-28
    • /
    • 1995
  • In recent years there has been a growing interest in total body irradiation. For refractory leukemia or lymphoma patients, varions techniques and dose regimens were intridused, including high dose total body irradiation for destruction of leukemic or bone marrow cells and immunosupperression prior to bone marrow transplantation. Accurate provision for specified dose and the desired homogeneity are essential before clinical total body irradiatio. When performed in total body irradiation, the problem obtain uniform uniform dose distribution in brain, neck, lung, umbilicus, pelvis and leg. Authors compared to dose distribution with method 1 and method 1. The method 1 used compensationg filters for homogeneous dose distribution(Minesota University Method). The method 2 used fixing frame made in acryl developing authors. Results were following 1. Method 1 was showed dose distribution from 95.6% to 100%, method 2 showed dose distribution from 95.4% to 100% 2. Method 2 was showed different to 3.4% at skin region and midline in the brain. In the neck, showed different to 1.5%. In the umbilicus, showed different to 2.3%.

  • PDF

Design of a Miniature Power Divider Based on the CRLH Zeroth Order Resonator with the Bandpass Filtering for the Military Satellite (군 위성통신 중계기용 대역통과 여파기 특성을 갖는 CRLH O-차 공진 기반 소형 전력분배기의 설계)

  • Eom, Da-Jeong;Kahng, Sung-Tek;Song, Choong-Ho;Woo, Chun-Sik;Park, Do-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.8C
    • /
    • pp.637-644
    • /
    • 2012
  • In this paper, a new compact power divider is suggested. Instead of the quarter wavelength transmission line(TX-line)s for the branches of the conventional Wilkinson's power divider design method, we use our composite right- and left-handed(CRLH) TX-line zeroth order resonator(ZOR) bandpass filters of one twelfth wavelength and reduce the physical length of the power divider. Besides, the filters in the branches can secure the passband for power-division. To validate the proposed power divider, we take an L-band for millitary satellaite transponder as the test case and the performances of the circuit and full-wave simulation results with the CRLH properties of the structure are shown with the dispersion curve and E-field at the ZOR. The measurement is compared with the simulation results. Also, the size reduction effect by the proposed scheme is addressed

Dose Distribution of Total Body Irradiation for Bone Marrow Transplantation in Leukemia (백혈병에서 골수이식을 위한 전신방사선조사시 선량분포 특성)

  • 김성규;김명세;신세원
    • Progress in Medical Physics
    • /
    • v.7 no.2
    • /
    • pp.47-55
    • /
    • 1996
  • Total Body Irradiation(TBI) is one of the essential treatment modalities in bone marrow transplantation for leukemia and lymphoma. Various techniques and dose regimens were introduced with sevelal advantages and disadvantages. In TBI, lung block could reduce lung dose to 75% of original beam for decreasing lung dose with homogenous total body irradiation. Accurate provision for specified dose and the desired homogeneity are essential before clinical total body irradiation. When performed in total body irradiation, the problem obtain uniform dose distribution in brain, neck, lung, umbilicus, pelvis and leg. Authors compared to dose distribution with method 1 and method 2. The method 1 used compensating filters for homogeneous dose distribution(Minesota University Method). The method 2 used fixing frame made in aeryl developing authors. Results were following. 1. Method 1 was showed dose distribution from 95.6% to 100%, method 2 showed dose distribution from 95.4% to 100%. 2. Method 2 was showed different to 3.4% at skin region and midline in the brain. In the neck, showed different to 1.5%. In the umbilicus. showed different to 2.3%.

  • PDF

Optimization of Coaxial to Microstrip Transition (동축커넥터와 마이크로스트립의 전이구조 최적화)

  • 강경일;김진양;이해영
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.2
    • /
    • pp.70-77
    • /
    • 2003
  • In this paper, analysis and measurement on coaxial connecter designed for packaging of microwave and micro strip transition structure are carried out. Even though researches on optimization of various kinds of transition structures have been conducted actively; however, the range of the application was very limited since they have been focused mainly on improvement of specific transmission line. Therefore, in this paper, we tried to analyze three kinds of substrates of which dielectric constants are 2,5,10 and are commercially used nowadays. Besides, we have confirmed reliability of FEM analysis, extracted equivalent circuit of transition area, found out factors determining extracted physical values, and made proof of electromagnetic variations for optimum characteristics. In addition, transition structure showing optimized characteristics on the basis of dielectric and microstrip structure was proposed. We reckon that the result of this research will apply with effect to transition design in microwave packaging development.

Analysis of Transmission Mode and Bandwidth for LF and MF Antenna (중·장파 대역 안테나의 대역폭 및 전송방식 해석)

  • Kim, Young-Wan
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.4
    • /
    • pp.401-407
    • /
    • 2018
  • The transmission bandwidth of shorted-monopole antenna in the frequency range of LF and MF was analyzed and the transmission mode considering the permissible data rate dependant on the transmission bandwidth was analyzed in this paper. Based on the required ERP, the output power of transmitter was deduced by considering the antenna efficiency. The analyses are for DGPS and time information transmission system in the frequency range of 283.5kHz and 65kHz respectively. The transmission antenna was modeled as TLM antenna that designed in the limited antenna site. The antenna equivalent circuit and antenna bandwidth were deduced based on the simulation analysis of antenna characteristics. The analyzed antenna bandwidth was compared with the simulated antenna bandwidth. Also the transmission mode for transmitter of LF and MF was proposed by considering the antenna bandwidth.

Dual-Band Unequal Power-Divider Miniaturized by Metamaterial CRLH Phase-Shift Lines (메타 재질 구조 CRLH 전송선 기반 소형 이중 대역 비균등 전력분배기)

  • Eom, Da-Jeong;Kahng, Sung-Tek
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.9
    • /
    • pp.1048-1057
    • /
    • 2012
  • In this paper, a new compact dual-band unequal power divider is suggested. Instead of the quarter wavelength transmission line(TX-line)s for the branches of the conventional Wilkinson's power divider, we use composite right- and left-handed(CRLH) phase-shift lines and can reduce the physical length. With the non-linear dispersion of the meta-meterial, each branch in the proposed divider is designed to have $+90^{\circ}$ and $-90^{\circ}$ at $f_1$ and $f_2$ respectively. To validate the proposed method, the performances of the circuit and full-wave simulation results are shown with the CRLH dispersion curve. The measurement results are compared with the simulation results. Also, the size reduction effect by the proposed scheme is addressed.

Development and Evaluation of Quality Assurance Worksheet for the Radiation Treatment Planning System (방사선치료계획 시스템의 정도관리 절차서 개발 및 유용성 평가)

  • Cho Kwang Hwan;Choi Jinho;Shin Dong Oh;Kwon Soo Il;Choi Doo Ho;Kim Yong Ho;Lee Sang Hoon
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.186-191
    • /
    • 2004
  • The periodic Quality Assurance (QA) of each radiation treatment related equipments is important one, but quality assurance of the radiation treatment planning system (RTPS) is still not sufficient rather than other related equipments in clinics. Therefore, this study will present and test the periodic QA program to compare, evaluation the efficiency of the treatment planning systems. This QA program is divided to terms for the input, output devices and dosimetric data and categorized to the weekly, monthly, yearly and non-periodically with respect to the job time, frequency of error, priority of importance. CT images of the water equivalent solid phantom with a heterogeneity condition are input into the RTPS to proceed the test. The actual measurement data are obtained by using the ion chamber for the 6 MV, 10 MV photon beam, then compared a calculation data with a measurement data to evaluate the accuracy of the RTPS. Most of results for the accuracy of geometry and beam data are agreed within the error criteria which is recommended from the various advanced country and related societies. This result can be applied to the periodic QA program to improve the treatment outcome as a proper model in Korea and used to evaluate the accuracy of the RTPS.

  • PDF

Ring-Shaped Inductive Sensor Design and Application to Pressure Sensing (환형 인덕티브 센서의 설계 및 압력센서로의 적용)

  • Noh, Myounggyu;Kim, Sunyoung;Baek, Seongki;Park, Young-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.10
    • /
    • pp.995-999
    • /
    • 2015
  • Inductive sensors are versatile and economical devices that are widely used to measure a wide variety of physical variables, such as displacement, force, and pressure. In this paper, we propose a simple inductive sensor consisting of a thin partial ring and a coil set. The self-inductance of the sensor was estimated using magnetic circuit analysis and validated through finite element analysis (FEA). The natural frequency of the ring was estimated using Castigliano's theorem and the method of equivalent mass. The estimation was validated through experiments and FEA. A prototype sensor with a signal processing circuit is built and applied to noninvasively sense the pressure inside a flexible tube. The obtained sensor outputs show quadratic behavior with respect to the pressure. When fitted to a quadratic equation, the least-square measurement error was less than 2%. The results confirm the feasibility of pressure sensing using the proposed inductive sensor.