• Title/Summary/Keyword: 레이져

Search Result 272, Processing Time 0.031 seconds

Characterization of relationship between particle size and powder properties for $BaTiO_3$ ($BaTiO_3$의 입도와 분체특성과의 상관 관계 연구)

  • Chun, M.P.;Cho, J.H.;Kim, B.I.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.15 no.6
    • /
    • pp.244-251
    • /
    • 2005
  • The relationship between particle size of hydro-thermally synthesized barium titanate powders (BT01, BT02, BT03, BT04, BT05) and the powder properties was investigated by means of particle size, specific surface area, zeta potential, XPS, XRD and SEM. Particle size determined by laser light scattering is closely related with specific surface area and the tetragonality (c/a) obtained from XRD. The specific surface area of the samples inversely decreased with increasing particle size except BT03 powder. BT03 sample showed higher surface area than BT04 sample of equivalent particle size, which was attributed mostly to the agglomeration of particles in terms of SEM image and XRD analysis. Zeta potential increased with increasing particle size with the exception of BT02 and BT03 which showed larger minus value of zeta potential in comparison with other BT powders. Beta potential results of BT02 and BT03 are considered to be related with the dissolution of $Ba^{2+}$ ion in these powers which was examined by XPS.

Photophysical Parameters, Photodecomposition, Fluorescence Quenching and Convolutive Voltammetry of 7-Diethylaminocoumarin (DEAC) Laser Dye (7 Diethylaminocoumarin (DEAC) 레이져 염료의 광물리적 파라미터, 광분해, 형광 소광 및 Convolutive Voltammetry)

  • El-Daly, S.A.;El-Hallag, I.S.
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.1
    • /
    • pp.13-22
    • /
    • 2010
  • The photophysical properties of 7-diethylaminocoumarin (DEAC) laser dye have been measured in different solvents. The emission spectrum of DEAC has also been measured in cationic (CTAC) and anionic (SDS) micelles. The laser parameters have been calculated in different solvents namely acetone, dioxane, ethanol and dimethylforamide(DMF). The photoreactivity of DEAC has been studied in $CCl_4$ solvent using 366 nm light. The values of photochemical yield (${\Phi}_c$) and rate constant (k) are determined. The interaction of organic acceptors such as picric acid (PA), tetracyanoethylene (TCNE) and 7,7,8,8-tetracynoquinonedimethane (TCNQ) with DEAC are also studied using fluorescence measurements in acetonitrile ($CH_3CN$). The electrochemical investigation of (DEAC) has been carried out using cyclic voltammetry and convolutive voltammetry combined with digital simulation technique at a platinum electrode in 0.1 mol $L^{-1}$ tetrabutyl ammonium perchlorate (TBAP) in $CH_3CN$ solvent. The electrochemical parameters of the investigated compound were determined using cyclic and convolutive voltammetry. The extracted electrochemical parameters were verified and confirmed via digital simulation method.

Optical Properties of Vertical Cavity Laser - Depleted Optical Thyristor for Low Threshold Current (낮은 문턱 전류를 위한 Vertical Cavity Laser - Depleted Optical Thyristor 의 레이징 특성에 관한 연구)

  • Choi Woon-Kyung;Choi Young-Wan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.7 s.349
    • /
    • pp.1-6
    • /
    • 2006
  • We show for the first time the optical properties of the selectively oxidized vertical cavity laser (VCL) - depleted optical thyristor (DOT), which has not only a low threshold current, but also a high sensitivity to the optical input light. In order to analyze their switching characteristics, nonlinear s-shaped current-voltage characteristics are calculated and the reverse full-depletion voltages (Vneg's) are obtained as function of semiconductor parameters by using a finite difference method (FDM). The selectively oxidized PnpN VCL-DOT clearly shows the nonlinear s-shaped current-voltage and lasing characteristics. A switching voltage of 5.24 V, a holding voltage of 1.50 V, a spectral response at 854.5 nm, and a very low threshold current of 0.65 mA is measured, making these devices attractive for optical processing applications.

Analysis of Wavelength Conversion Characteristics in SSGDBR Laser Diode (SSGDBR 레이저 다이오드의 파장변환 특성 해석)

  • Kim, Su-Hyun;Chung, Young-Chul
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.2
    • /
    • pp.81-89
    • /
    • 1999
  • Among various wavelength conversion technologies, that using the cross-gain modulation in laser diode makes it possible to deal with the high speed signal quite simply and efficiently. In this paper, presented was the applicability of an improved time-domain large-signal dynamic model as a CAD tool to analyzed the characteristics of SSGDBR(Superstructure Grating Distributed Bragg Reflector) laser diodes used for wavelength converters. Using this model, it was shown that this kind of wavelength converter can provide the widely tunable wavelength conversion of the high speed data above 10 Gbps. We also investigated the effect of input optical power and the bias current on the characteristics of the device such as extinction ration and eye diagram. The modeling results show very similar trend to the experimental reports.

  • PDF

Measurements of Thermal Diffusivity of Heavy Rolled Low Carbon Steel Plate With Laser Flash Technique (레이저 섬광법에 의한 압연된 저탄소강 판재의 열확산계수 측정)

  • 배신철;임동주
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.157-171
    • /
    • 1990
  • The heat transfer problem associated with pulse technique for measuring thermal diffusivity was solved by means of Green function. The obtained general solution was discussed so as to apply for all possible cases; kinds of boundary condition and heat source, irradiation positions of heat pulse, radius of heat pulse, one-and two-dimensional heat flow, finite pulse time effects and radiation heat loss systems. Experimentally, the laser flash lamp was used as heat source for measuring thermal diffusivity of low carbon, aluminium chilled steel plate, which was heavily rolled in order to measure the variation of thermal diffusivity in the temperature range from room temperature through 500.deg. C. The derived results are (1) materials produced from same furnace showed a somewhat different thermal diffusivity values. (2) the thermal diffusivity value of rolled material was smaller than unrolled material and the difference decreased as increasing temperature. (3) the thermal diffusivity value of an annealed and temper rolled material was larger than the value of a cold rolled material, even thought smaller than unrolled material. (4) In case of heavy rolled material, there was no consistent relationships between the thermal diffusivity and the reduction in thickness.

Microstructure and Hardness Distributions of $CO_2$ Lser Hrdened 12%-Cr Seel (12%-Cr 강의 $CO_2$ 레이저 표면경화에서 금속조직과 경도분포)

  • 김재도
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.10
    • /
    • pp.1861-1868
    • /
    • 1992
  • Laser beam hardening of 12%-Cr steel has been evaluated by using a continuous wave 3kW co$_{2}$ laser with a hardening mirror set. Experiment was performed on the hardening condition with a laser power of 2.85kW and travel speed of 1.0 and 1.5m/min. Multi passes have been also tried to find the hardening characteristics of partly overlapped zone. The black paint to use at high temperature was adopted to increase the absorptivity of laser beam energy with the wavelength of 10.6.mu.m at the surface of base metal. The microstructure of the hardened layers was observed by using a light microscopy, SEM and TEM. A fine Lamellar martensite formed in the hardened zones exhibits very high Vickers microhardness of 600Hv, whereas the tempered martensite distributes in the base metal with Vickers microhardness of 240Hv.It has been found that laser hardening with multi passes showed no significant drop of the hardness between adjacent passes.

An Investigation on the Flow Characteristics of Water Spray Nozzle (미세 물분무 노즐의 유동특성에 관한 연구)

  • Jun, You Woo;Han, Young Tak;Kim, Chang Seob;Kim, Chang;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.29-33
    • /
    • 2015
  • In this study, the relations of flow rate, discharging distance and droplet size are measured in accordance with the nozzle shape. The dual type nozzles of LPN142 and LPN148, which have identical core diameter (6.0 mm) and the different radial injection angles (${\theta}_2=142^{\circ}$ and $148^{\circ}$), are manufactured. The distribution diameters with discharging distance are quantified by UL2167 test standard. The relations between discharging angle and droplet sizes, which are measured by the method of Helium-Neon laser equipment, are obtained by the empirical correlation as working pressure increase. Moreover, the extinction coefficient, which is major parameter of the radiative transport equation (RTE) is analyzed with variable droplet sizes. Thus, it is possible to opt the nozzle's shape by analyzing the relations of working pressure, spray distance, droplet size and fire characteristics at minimum allowable flow rate.

Effects of Low Reactive Level Laser Irradiation (LLLI) on the Wound Infected with Staphylococcus Aureus (저출력레이져조사가 Staphylococcus aureus 에 감염된 창상에 미치는 영향)

  • Phil-Yeon Lee;Ki-Suk Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.1
    • /
    • pp.153-171
    • /
    • 1996
  • 저수준레이저를 이용하여 창상이나 병소의 치유과정에 대한 효과를 조사하기 위하여 많은 연구가 시행되었다. 연구에 의하면 갈륨비소 레이저광이 생체자극효과를 가진다고 하며, 저수준레이저를 조사하면 단백질과 핵산 (DNA) 합성을 자극하여 치은섬유아세포의 증식을 촉진한다고 보고하였다. 외상병소나 근육병소의 치료에 사용된 레이저치료법에 관한 관심이 점증함에 따라 저수준레이저요법 (LLLI)의 치유효과를 설명하기 위하여 분자생물학적 수준의 연구를 시행하기에 이르렀다. 보고에 의하면 Mutans Streptococcide 는 LLLI를 사용시 증식이 촉진되며, 다른 세균에서도 유사한 증식효과가 나타날 것이라고 주장하였다. 그러므로 LLLI가 피부감염을 야기하는 가장 흔한 원인인 Staphylococcus aureus 도 마찬가지로 증식이 촉진되는 지를 조사해볼 필요가 있으며, 또한 감염과 같이 특정 병적 상태에서의 저수준레이저광의 효과는 아직까지 명확하게 밝혀져 있지 않았다. 그러므로 본 연구의 목적은 첫째, Staphyloc occus aureus 의 증식에 대한 저수준레이저광의 효과를 조사하는 실험이며, 둘째 Staphylococcus aureus 로 가염된 피부창상에 대한 저수준레이저광의 효과를 판정하는데 있다. 34개의 Staphylococcus aureus 배양표본을 사용하여 48시간의 세포주기동안 조사기간과 조사시간, 그리고 레이저 펄스(laser pulse)형에 따라 3가지 실험을 시행하여 증식에 가장 효과적인 상태와 가장 비효과적인 상태의 갈륨비소 반도체 레이저펄스를 결정하였다. 이후 지름 약 6 mm의 개방창상을 44마리 백서의 양측 대퇴부에 형성하여 모든 창상에 S. aureus를 감염시켰다. 모든 표본은 펄스형과 조사방법 (중앙조사법과 주변조사법)에 따르는 실험을 하기 위하여 4가지로 분류하였다. 각 백서의 양측 창상중 하나는 1,3,5,7일 마다 각 실험의 방법에 따라 레이저를 조사하고 실험동물의 다른 창상은 대조군으로서 사용하였다. 모든 창상의 면적은 실험 1,3,5,7 일째에 일정한 거리에서 사진촬영하여 면적계를 이용, 측정한 후 통계적인 의의를 조사하였다. 본 연구의 결과는 저수준레이저는 특정 조건하에서 S. aureus의 증식을 촉진하였다. 그러나 S. aureus에 감염된 창상을 저수준레이저로 조사시 치유가 촉진되었다. 중앙 조사법고 주변조사법에 의한 창상치유효과는 통계적인 의의가 보이지 않았다. 따라서 결론적으로 S. aureus 에 감염된 창상에 직접 또는 간접적이든 pulse의 종류에 관계없이 조사하는 경우 치유효과가 나타나는 것은 정사주위 조직의 LLLI 자극효과가 염증의 확산을 억제한다고 말할수 있다.

  • PDF

$ZnO_{1-x}S_x$ 버퍼층 건식 성장 시 스퍼터링 파워 변화에 따른 CIGS 태양전지 특성

  • Wi, Jae-Hyeong;Jo, Dae-Hyeong;Kim, Ju-Hui;Park, Su-Jeong;Jeong, Jung-Hui;Han, Won-Seok;Jeong, Yong-Deok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.684-685
    • /
    • 2013
  • p-형 반도체인 Cu(In,Ga)$Se_2$ (CIGS) 광 흡수 층은 이보다 에너지 밴드 간격이 큰 n-형 반도체와 이종 접합을 형성한다. 흡수층과 윈도우층 사이의 결정구조 차이와 밴드갭 에너지 차이를 완화시키기 위해 버퍼층이 필요하다. 버퍼층을 형성하는 물질로 화학적 용액 성장법(Chemical Bath deposition)을 사용한 CdS가 많이 적용되어 왔으나 Cd의 유해성 및 습식 공정으로 인한 연속공정에 대한 어려움이 있다. 따라서 버퍼층을 Cd을 포함하지 않는 ZnS, $In_2S_3$, (Zn, Mg)O 등과 같은 물질로 대체하여 원자층 증착법(Atomic Layer Deposition), 펄스레이져증착법(Pulsed Laser Deposition), 스퍼터링(sputtering) 등과 같은 건식으로 성장시키는 연구가 활발히 진행되고 있다. 본 연구에서는 $ZnO_{1-x}S_x$ ($0.2{\leq}x{\leq}0.4$)를 반응성 스퍼터링으로 증착하여 큰 밴드갭 에너지와 높은 광투과율를 갖는 버퍼층을 제작하였다. CIGS 박막의 손상을 줄여주기 위하여 RF 파워는 240, 200, 150, 100 W로 변화시켰다. CIGS 태양전지의 I-V 측정 결과, RF 파워가 150 W일 때 10.7%의 가장 높은 변환 효율을 보였고, 150 W 이상에서는 파워가 증가할 때 단락전류는 감소하였으며 개방전압은 다소 증가하였다. 반면 100 W에서 단락전류는 다소 증가하는 것에 반해 개방 전압이 급격히 낮아졌다. 이것은 파워에 따라 결합되는 산소의 양이 다르기 때문으로 생각된다.

  • PDF

The comparison about lumbar extensor strength between pre op group and post op(after 6 weeks) group in HIVD patient (만성요통환자의 레이져 수술전과 수술6주후의 요부신전근력에 관한 비교)

  • Park, Sung-Kwang;Sok, Hye-Kyong;Kim, Myung-Joon
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.1
    • /
    • pp.353-365
    • /
    • 2000
  • The purpose of this study were to compare the lumbar extensor strength between pre op patients group and after 6 weeks post op patients group. To evaluate lumbar extensor strength of total 273 patients with HIVD. Lumbar extensor strength was measured in 151 male patients and 122 female patients(Lumbar extensor strength was measured in 91 PELD patients group and 182 OLM group patients) by Medx lumbar extension machine. Maximum voluntary lumbar extension strength was appear $149.36{\pm}61.92ft$-lbs in pre op of PELD group, $158.47{\pm}54.67ft$-lbs in post op of PELD group and $135.54{\pm}54.24ft$-lbs in pre op of OLM group. $147.19{\pm}52.42ft$-lbs in post op of OLM group in male. Maximum voluntary lumbar extension strength was appear $83.85{\pm}30.22ft$-lbs in pre op of PELD group. $92.99{\pm}28.66ft$-lbs in post op of PELD group and $75.16{\pm}24.98ft$-lbs in pre op of OLM group, $79.88{\pm}25.25ft$-lbs in post op of OLM group in female. Male and female lumbar extension strength was statistically significant difference(P<.05). Lumbar flexion/extension ratio of the two group was 2.14:1 pre op and 2.05:1 post op in lumbar flexion 72 and 0 degree. The ratio of post op group was lesser than pre op group.

  • PDF