• Title/Summary/Keyword: 띠철근 기둥

Search Result 69, Processing Time 0.023 seconds

Effect of ties on the ductility in reinforced concrete rectangular column (띠철근 형상이 철근 콘크리트 사각형 기둥의 연성에 미치는 영향)

  • Han, Chang-Yun;Kim, Chang-Hoon;Park, Sang-Yeol;Jwa, Yong-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.81-82
    • /
    • 2009
  • The purpose of this study is to evaluate the influence that shape of tie has on the ductility of reinforce concrete rectangular column with experiment. There is the standard of the shape and arrengement of tie bar for RC column, but nevertheless currently a tie used in some fields under construction has been constructed in different way from the design for the convenience of construction. A research was required to analyze the problem on the behavior of RC column caused from a shoddy and fault construction of tie, and then evaluate the safety.

  • PDF

Evaluation of Axial Behavior of Columns Strengthened with Different Transverse Reinforcements in Jacket Section (확대단면에서의 띠철근 배근 방법에 따른 보강 기둥의 중심 축하중 거동 평가)

  • Hwang, Yong-Ha;Yang, Keun-Hyeok;Sim, Jae-Il;Choi, Yong-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.81-88
    • /
    • 2018
  • The present study evaluated the effective arrangement approach of transverse reinforcement in the jacket section for seismic strengthening of reinforced concrete columns. To simulate the full-scale columns, the section dimensions were determined as $450{\times}450mm$ for non-seismic existing columns and $750{\times}750mm$ for section enlargement strengthening columns. Over-lapped channel-shape bars and prefabricated bar units were proposed for closed-hoops in the jacket section, and conventional cross-ties anchored into existing columns and V-ties were considered for the supplementary ties. Test results showed that the axial capacity of the existing column and section enlargement columns with over-lapped channel-shape hoops was similar to the nominal strength calculated using ACI 318-14 procedure whereas the section enlargement column with prefabricated bar units possessed 1.25 times higher axial capacity than the nominal prediction. Furthermore, the axial ductility ratio of the section enlargement column with prefabricated bar unit was 139% higher than that of the existing column despite the potential size effect on ductility of concrete. Thus, it can be concluded that the developed prefabricated bar unit technique is practically useful for preventing the premature buckling of longitudinal reinforcement and confining core concrete in the section enlargement strengthening columns.

Fire Resistance of High Strength Concrete Columns with Tie Spacing (띠철근 간격에 따른 고강도 콘크리트 기둥의 내화 성능)

  • Park, Chan-Kyu;Lee, Seung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.393-396
    • /
    • 2008
  • This paper presents the experimental results on the fire performance of high strength concrete(HSC) column made with different tie spacing. Three HSC columns measuring 305${\times}$305mm in cross section were prepared to evaluate the effect of tie spacing with 150, 210, 300mm, respectively. Compressive strength was 69MPa at test. As a result, the fire performance of HSC columns was greatly influenced by tie spacing. The fire resistance increases with decreasing the tie spacing.

  • PDF

Seismic Performance of Octagonal Flared RC Columns using Oblong Hoops (장방형 띠철근을 이용한 팔각형 플레어 RC 기둥의 내진성능)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.1-9
    • /
    • 2015
  • Transverse steel bars are used in the plastic hinge zone of columns to insure adequate confinement, prevention of longitudinal bar buckling and ductile behavior. Fabrication and placement of rectangular hoops and cross-ties in columns are difficult to construct. Details of reinforcement for rectangular section require a lot of rectangular hoops and cross-ties. In this paper, to solve these problems, the new lateral confinement method using oblong hoop is proposed for the transverse confinement of the flared column. It can be the alternative for oblong cross-section and flared column with improved workability and cost-efficiency. The final objectives of this study are to suggest appropriate oblong hoop details and to provide quantitative reference data and tendency for seismic performance or damage assessment based on the drift levels such as residual deformation, elastic strain energy. This paper describes factors of seismic performance such as ultimate displacement/drift ratio, displacement ductility, response modification factor, equivalent viscous damping ratio and effective stiffness.

Failure Behavior of Octagonal Flared RC Columns Using Oblong Hoops (장방형 띠철근을 이용한 팔각형 플레어 RC 기둥의 파괴거동)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.58-68
    • /
    • 2014
  • Transverse steel bars are used in the plastic hinge zone of columns to insure adequate confinement, prevention of longitudinal bar buckling and ductile behavior. Fabrication and placement of rectangular hoops and cross-ties in columns are difficult to construct and require larger amount of transverse steels. In this paper, to solve these problems, the new lateral confinement method using oblong hoop is proposed for the transverse confinement of columns of the oblong cross-section and flared column. The experimental study for octagonal oblong cross-section was carried out by the flared columns test in strong axis. The lateral confinement method using proposed oblong hoop detail showed satisfactory performance of lateral confinement. Therefore it can be the alternative for oblong cross-section and flared column with improved workability and cost-efficiency.

Influence of Concrete Strength and Lateral Ties on Behavior of High-Strength Concrete Columns Subjected to Eccentric Compressive Load (편심 압축력을 받는 고강도 콘크리트 기둥의 거동에 미치는 띠철근 및 콘크리트 강도의 영향)

  • Lee, Young Ho;Chung, Heon Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.95-104
    • /
    • 2007
  • This study was focused on the effect of concrete strength and lateral ties of concrete columns subjected to eccentric compressive loads. The twenty-four concrete columns with $200mm{\times}200mm$ square cross-section were tested. The main variables were concrete strength, spacing and configuration of lateral ties, and eccentricity ratios. From the experiment, the followings were investigated ; 1) In all cases, it was observed that the increase of concrete compressive strength led to the decrease of ductility. Also, as the eccentricity ratios increased, the effect of ductility enhancement by lateral ties decreased. 2) As the ties spacing decreased from 100mm to 30mm, the magnitude of axial load acting on the concrete column showed an enhancement of 1.1~1.2 times and the descending curve after a peak moment presented a smooth decline. 3) The high-strength concrete columns required a design of lateral ties to increase the volumetric ratios and density of tie spacing to sustain a proper strength and ductility. Accordingly, regardless of concrete strength, the current AIK design code to specify the maximum tie spacing of concrete columns was proven to lead to the poor strength and ductility for seismic design. Therefore, it is necessary to develop a new seismic design code that connects volumetric ratios and tie spacing of concrete columns with concrete strength.

Reversed Cyclic Loading Tests on Precast Beam-Column Joints with Headed Reinforcement (프리캐스트 보-기둥 헤드철근 연결부 반복하중 실험)

  • Kim, In-Gyu;Yu, Sung-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.3
    • /
    • pp.369-376
    • /
    • 2003
  • One of the most complex reinforcement location in the precast building frame is the beam-column joint in a prefabricated construction. It is generally resulted from the vortical bars of column, anchorage bars of beam, and bars of hoop. Particularly the hooked anchorage bars of beam are confronted with hoop and main column bars. The headed reinforcement is considered to place them easily and to reduce the anchorage length in a precast construction. Reversed cyclic loading tests are performed on four beam-column specimens to evaluate the strength and behavior of beam to column and column to column connections. The result of test shows that the headed reinforcement has a similar performance than that of hooked reinforcement in a precast specimen with strong column and weak beam joints. The splice column joints which are used frequently in the domestic fields also show reliable behaviors in those tests with strong column and weak beam joints.

Effect of T-Plate Anchorage on the Flexural Behavior of Reinforced Concrete Columns Strengthened with Wire Rope Units (와이어로프로 보강된 철근콘크리트 기둥의 휨 거동에 대한 강판 정착의 영향)

  • Sim, Jae-Il;Yang, Keun-Hyeok;Byun, Hang-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.493-494
    • /
    • 2009
  • Two strengthened columns and an unstrengthened control column were tested to failure under cyclic lateral load combined with a constant axial load to effect of anchorage of T-shaped steel plate in the strengthened column using wire rope units. Main variables considered were anchorage method of T-shaped steel plate. Tested columns were compared with those of conventionally tied columns tested by research of before. Test results showed that lateral load capacity and the displacement ductility ratio of anchorage of T-shaped steel plate in the strengthened column increased 40% and 130% than unstrengthened column, respectively. In particular, at the same effective lateral reinforcement index, a much ductility ratio was observed in the strengthened columns than in the tied columns.

  • PDF

The Volumetric Ratio of Transverse Reinforcement of R/C Columns Considering Effective Lateral Confining Reduction Factor (유효횡구속압력 감소계수를 사용한 RC 기둥의 횡보강근량 평가)

  • Kim, Jong-Keun;Ahn, Jong-Mun;Shin, Sung-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.3
    • /
    • pp.311-318
    • /
    • 2009
  • An experimental investigation was conducted to examine the hysteretic behaviors of ultra-high strength concrete tied columns. The purpose of this study is to propose the volumetric ratio of transverse reinforcement for ultra-high strength concrete tied columns with 100 MPa compressive strength. Nineteen 1/3 scaled columns were fabricated to simulate an 1/2 story of actual structural members with the main variables of axial load ratio, configurations and volumetric ratios of transverse reinforcement. The results show that the deformability of columns are affected by the configurations and volumetric ratios of transverse reinforcement. Especially, it has been found that the behavior of columns are affected by axial load ratio rather than the amounts and the configurations of transverse reinforcement. To improve the ductility behavior of RC column using ultra high strength concrete in a seismic region, We suggested the amount of transverse reinforcement for all data that satisfy the required displacement ductility ratio over 4. It is means that the lateral confining reduction factor (${\lambda}^c$) considering the effective legs, configuration and spacing of transverse reinforcement and axial load ratio was reflected for the volumetric ratio of transverse reinforcement.

Bearing Strength of Concrete Column and Steel Beam Composite Joints (콘크리트 기둥과 철골 보 합성골조 접합부에서의 지압강도)

  • Kim, Byong-Kook;Lee, Won-Kyu;Choi, Oan-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.3
    • /
    • pp.417-424
    • /
    • 2003
  • A bearing failure in RCS(Reinforced Concrete Column and Steel Beam) system is recognized as one of the distinct joint failure modes for the composite frames. Vertical and transverse reinforcement in addition to concrete are effective for better transfer of vortical forces through concrete bearing. To examine the effect of the vertical bars, tie bars, a U-type detail developed in this study and concrete confinement, local bearing tests were conducted using 22 small-scale concrete block specimens. Test results show that vertical reinforcement and tie bars mainly contribute to the bearing capacity. However larger amounts of tie reinforcement are required than those recommend from ASCE guidelines, to apply the nominal concrete strength as 2 $f_{ck}$ over the bearing area. Cross ties are proved to be highly effective for resisting the vertical forces. Maximum bearing strength can be increased upto 2.5 $f_{ck}$ . An accurate prediction model for bearing strength is proposed for better design of the composite Joint.