Browse > Article
http://dx.doi.org/10.4334/JKCI.2009.21.3.311

The Volumetric Ratio of Transverse Reinforcement of R/C Columns Considering Effective Lateral Confining Reduction Factor  

Kim, Jong-Keun (Dept. of Architectural Engineering, Hanyang University)
Ahn, Jong-Mun (Dept. of Architectural Design, Ansan College)
Shin, Sung-Woo (Dept. of Architectural Engineering, Hanyang University)
Publication Information
Journal of the Korea Concrete Institute / v.21, no.3, 2009 , pp. 311-318 More about this Journal
Abstract
An experimental investigation was conducted to examine the hysteretic behaviors of ultra-high strength concrete tied columns. The purpose of this study is to propose the volumetric ratio of transverse reinforcement for ultra-high strength concrete tied columns with 100 MPa compressive strength. Nineteen 1/3 scaled columns were fabricated to simulate an 1/2 story of actual structural members with the main variables of axial load ratio, configurations and volumetric ratios of transverse reinforcement. The results show that the deformability of columns are affected by the configurations and volumetric ratios of transverse reinforcement. Especially, it has been found that the behavior of columns are affected by axial load ratio rather than the amounts and the configurations of transverse reinforcement. To improve the ductility behavior of RC column using ultra high strength concrete in a seismic region, We suggested the amount of transverse reinforcement for all data that satisfy the required displacement ductility ratio over 4. It is means that the lateral confining reduction factor (${\lambda}^c$) considering the effective legs, configuration and spacing of transverse reinforcement and axial load ratio was reflected for the volumetric ratio of transverse reinforcement.
Keywords
ultra-high strength concrete; tied column; configuration; transverse reinforcement; lateral confining reduction factor;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 ACI Committee 318, “Building Code Requirements for Structural Concrete,” ACI 318-05 and ACI 318R-05, American Concrete Institute, Farmington Hills, Michigan, USA, 2005. 430 pp.
2 Sakai, K. and Sheikh, S. A., “What Do We Know about Confinement in Reinforced Concrete Columns?,” ACI Structural Journal, Vol. 86, No. 2, 1989, pp. 192-207
3 Sheikh, S. A. and Khouy, S. S., “A Performance-Based Approach for the Design of Confining Steel in Tied Columns,” ACI Structural Journal, Vol. 94, No. 4, 1997, pp. 421-431
4 Saatcioglu, M. and Razvi, S. R., “Displacement -Based Design of Reinforcement Concrete Columns for Confinement,” ACI Structural Journal, Vol. 99-S1, No. 1, 2002, pp. 3-11
5 안종문, “축력과 반복횡력을 받는 고강도 철근콘크리트 기둥의 거동,” 한양대학교 대학원 건축공학과 박사학위논문, 2000, 226 pp.
6 한범석, “고강도 콘크리트의 횡구속 모델과 고강도 철근콘크리트 띠철근 기둥의 압축거동,” 한양대학교 대학원 건축공학과 박사학위논문, 2002, pp. 161-175
7 이영호, 박성용, 정헌수, “지진형태의 하중을 받는 철근콘크리트 기둥의 스터브 효과에 미치는 축력비의 영향,” 대한건축학회 논문집, 24권, 5호 2008. pp. 75-84
8 Razvi, S. and Saatcioglu, M., “Confinment Model for High-Strength Concrete,” Journal of Structural Engineering, Vol. 125, No. 3, 1999, pp. 281-289   DOI   ScienceOn
9 Watson, S., Zahn, F. A., and Park, R., “Confining Reinforcement for Concrete Columns,” Journal of Structural Engineering, Vol. 120, No. 6, 1994, pp. 1798-1824   DOI   ScienceOn
10 Sheikh, S. A. and Uzumeri, S. M., “Strength and Ductility of Tied Concrete Columns,” ASCE Journal of Structural Engineering, Vol. 106, No. 5 1980 pp. 1079-1102