• Title/Summary/Keyword: 동공

Search Result 399, Processing Time 0.021 seconds

A Study on the Facal motion and for Detection of area Using Kalman Fillter algorithm (Facal motion 예측 및 영역 검출을 위한 칼만 필터 알고리즘)

  • Seok, Gyeong-Hyu;Park, Bu-Yeon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.6
    • /
    • pp.973-980
    • /
    • 2011
  • In this paper, we gaze upon the movement faces the problem points are difficult to identify a user based on points and that corrective action is needed to solve the identification system is proposed a new eye. Kalman filter, the current head of the location information was used to estimate the future position in order to determine the authenticity of the face facial features and structural elements, the information and the processing time is relatively fast horizontal and vertical elements of the face using the histogram analysis to detect. And an infrared illuminator obtained by constructing a bright pupil effect in real-time detection of the pupil, the pupil was tracked - geulrinteu vectors are extracted.

Effective real-time identification using Bayesian statistical methods gaze Network (베이지안 통계적 방안 네트워크를 이용한 효과적인 실시간 시선 식별)

  • Kim, Sung-Hong;Seok, Gyeong-Hyu
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.3
    • /
    • pp.331-338
    • /
    • 2016
  • In this paper, we propose a GRNN(: Generalized Regression Neural Network) algorithms for new eyes and face recognition identification system to solve the points that need corrective action in accordance with the existing problems of facial movements gaze upon it difficult to identify the user and. Using a Kalman filter structural information elements of a face feature to determine the authenticity of the face was estimated future location using the location information of the current head and the treatment time is relatively fast horizontal and vertical elements of the face using a histogram analysis the detected. And the light obtained by configuring the infrared illuminator pupil effects in real-time detection of the pupil, the pupil tracking was - to extract the text print vector.

Adsorption and Antibacterial Properties of Metal Ion Treated Activated Carbon Fiber (금속이온이 처리된 활성탄소섬유의 흡착과 항균성)

  • Oh, Won-Chun;Bang, Seong-Ho
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.131-135
    • /
    • 2000
  • We studied adsorption isotherm, surface properties and antibacterial activity of Cu treated activated carbon fiber (ACF). The BET surface area of Cu treated ACF are distributed to $688.2-887.8m^2/g$. The adsorption results show that BET surface areas move gradually to lower value with increasing treated Cu mole concentration. Using t-method, the specific micropore volumes and average pore size were obtained. From the SEM study, it is also observed that many of micropores in activated carbon fiber are blocked surface after the treatment. And we also observed that the activity of E. coli in kind of colon bacillus increases gradually to larger range with increasing Cu mole ratio. From these results, we suggest the antibacterial mechanism for metal treated ACF.

  • PDF

Real-Time Automatic Tracking of Facial Feature (얼굴 특징 실시간 자동 추적)

  • 박호식;배철수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.6
    • /
    • pp.1182-1187
    • /
    • 2004
  • Robust, real-time, fully automatic tracking of facial features is required for many computer vision and graphics applications. In this paper, we describe a fully automatic system that tracks eyes and eyebrows in real time. The pupils are tracked using the red eye effect by an infrared sensitive camera equipped with infrared LEDs. Templates are used to parameterize the facial features. For each new frame, the pupil coordinates are used to extract cropped images of eyes and eyebrows. The template parameters are recovered by PCA analysis on these extracted images using a PCA basis, which was constructed during the training phase with some example images. The system runs at 30 fps and requires no manual initialization or calibration. The system is shown to work well on sequences with considerable head motions and occlusions.

Real Time 3D Face Pose Discrimination Based On Active IR Illumination (능동적 적외선 조명을 이용한 실시간 3차원 얼굴 방향 식별)

  • 박호식;배철수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.3
    • /
    • pp.727-732
    • /
    • 2004
  • In this paper, we introduce a new approach for real-time 3D face pose discrimination based on active IR illumination from a monocular view of the camera. Under the IR illumination, the pupils appear bright. We develop algorithms for efficient and robust detection and tracking pupils in real time. Based on the geometric distortions of pupils under different face orientations, an eigen eye feature space is built based on training data that captures the relationship between 3D face orientation and the geometric features of the pupils. The 3D face pose for an input query image is subsequently classified using the eigen eye feature space. From the experiment, we obtained the range of results of discrimination from the subjects which close to the camera are from 94,67%, minimum from 100%, maximum.

Ethylene Production and Internal Structure of Developing Maize Seeds (옥수수 종자의 발육 중 ethylene 발생과 내부형태 변화)

  • Lee Suk-Soon;Seo Jung-Moon;Hong Seung-Beom
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.51 no.5
    • /
    • pp.425-431
    • /
    • 2006
  • In order to investigate the effects of ethylene on the seed development of three corn types (dent, sweet, and super sweet corns), aminoethoxyvinyl glycine (AVG) and silver thiosulfate (STS) and ethephon (2-chloroethylphosphonic acid, CEPA) were applied either on whole plants or shanks of ears at 9 and 21 days after silking. Ethylene production of developing super sweet corn seeds was much higher than those of sweet and dent corns. The cavity in the endosperm tissues of the super sweet corn started earlier and endosperm was collapsed more severely compared to those of sweet and dent corns. Ethylene production seemed to be related to the death of endosperm cells to form a cavity. Application of AVG and STS reduced ethylene production and delayed cavity formation in endosperm of super sweet corn seeds, while CEPA increased ethylene production and enhanced the time of cavity formation. AVG and STS increased 100-seed weight, while CEPA decreased.

The Changes in Contrast Sensitivity and Glare Sensitivity when Wearing Circle Contact Lenses after the Refractive Surgery (시력교정술 후 써클콘택트렌즈 착용 시 대비감도 및 눈부심감도 변화)

  • Kwon, Ki Nam;Park, Sang Hee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.23-34
    • /
    • 2016
  • Purpose: In the present study, the effect of circle contact lenses wear on contrast sensitivity and glare sensitivity in a refractive surgery group was investigated. Methods: The contrast sensitivity and glare sensitivity were evaluated using by CGT-1000 for a non-refractive surgery group as control group(40 eyes) and a refractive surgery group(30 eyes) applied plano circle contact lenses, and pupil size was also measured. The correlation between contrast/glare sensitivity and the pupil size was analyzed. Results: In the refractive surgery group, contrast sensitivity in the range of high spatial frequency decreased with wearing circle contact lenses, and amount of decrease for the refractive surgery group was larger than for the control group. The correlation between pupil size and the change of contrast sensitivity was decreased by wearing circle contact lenses, and the correlation was lower in the refractive surgery group than the control group. Furthermore, the wear of circle contact lenses affected on glare sensitivity. In analyzing the change of glare sensitivity by pupil size, the glare was larger in the refractive surgery group than control group. Circle contact lenses in refractive surgery group were not fitted on the center of cornea. Conclusions: In the present study, it is suggested that the sufficient understanding and consideration about the decrease of contrast sensitivity and the increase of glare by wearing circle contact lenses after the refractive surgery is necessary.

The Examination of Refractive Correction and Heterophoria and Monocular Pupillary Distance on Myopic Elementary School Children Wearing Glasses in Gwangju City (광주지역 근시안경 착용 초등학생의 굴절상태와 사위 및 단안PD에 대한 조사)

  • Hwang, Kwang-Ha;Seong, Jeong-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.71-75
    • /
    • 2009
  • Purpose: This study was designed to investigate the condition of refractive correction and heterophoria and monocular pupillary distance on myopic elementary school children wearing glasses in Gwangju city. Methods: Subjective refraction and objective refraction were examined after investigating heterophoria and monocular pupillary distance on 145 (290eye) elementary school children wearing myopia-corrected glasses. Results: 1. Anisometropia > 2.00 D was present in 4 children (3%). 2. 9 anisometropia (47%) were present in 19 undercorrected visual acuity boy wearers. and 16 anisometropia (64%) were present in 25 undercorrected visual acuity girl wearers. 3. Among the 67 myopic glasses boy wearers, the distance between optical centers was coincided with the pupillary distance in 30% (Oculus Uterque), and discrepant in 70% (Oculus Uterque). Among the 78 myopic glasses girl wearers, the distance between optical centers was coincided with the pupillary distance in 23% (Oculus Uterque), and discrepant in 77% (Oculus Uterque). The mean optical center distance was longer than the pupillary distance on both boy and girl wearers 4. The result of measured heterophoria revealed 14% for orthophoria, 63% for exophoria, 23% for esophoria at far distance and 10% for orthophoria, 76% for exophoria, 14% for esophoria at near distance. Conclusions: Correct refractive test and monocular pupillary distance must be examined because incorrect refractive test and pupillary distance induce asthenopia and heterophoria.

  • PDF

Discriminant Analysis of Human's Implicit Intent based on Eyeball Movement (안구운동 기반의 사용자 묵시적 의도 판별 분석 모델)

  • Jang, Young-Min;Mallipeddi, Rammohan;Kim, Cheol-Su;Lee, Minho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.212-220
    • /
    • 2013
  • Recently, there has been tremendous increase in human-computer/machine interaction system, where the goal is to provide with an appropriate service to the user at the right time with minimal human inputs for human augmented cognition system. To develop an efficient human augmented cognition system based on human computer/machine interaction, it is important to interpret the user's implicit intention, which is vague, in addition to the explicit intention. According to cognitive visual-motor theory, human eye movements and pupillary responses are rich sources of information about human intention and behavior. In this paper, we propose a novel approach for the identification of human implicit visual search intention based on eye movement pattern and pupillary analysis such as pupil size, gradient of pupil size variation, fixation length/count for the area of interest. The proposed model identifies the human's implicit intention into three types such as navigational intent generation, informational intent generation, and informational intent disappearance. Navigational intent refers to the search to find something interesting in an input scene with no specific instructions, while informational intent refers to the search to find a particular target object at a specific location in the input scene. In the present study, based on the human eye movement pattern and pupillary analysis, we used a hierarchical support vector machine which can detect the transitions between the different implicit intents - navigational intent generation to informational intent generation and informational intent disappearance.

Aberration Retrieval Algorithm of Optical Pickups Using the Extended Nijboer-Zernike Approach (확장된 네이보어-제르니케 방법에 의한 광픽업의 파면수차 복원 알고리즘)

  • Jun, Jae-Chul;Chung, Ki-Soo;Lee, Gun-Kee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.1
    • /
    • pp.32-40
    • /
    • 2010
  • In this work, the method of acquiring the pupil function of optical system is proposed. The wavefront aberration and the intensity distribution of pupil can be analysed with the pupil function. This system can be adopted to the manufacturing line of optical pickup directly and also has good performance to analysing various property of optical instrument. It is one kind of inverse problem to get pupil functions by 3D beam data. The extended Nijboer-Zernike(ENZ) approach recently proposed by Netherlands research group is adopted to accompany to solve these inverse problem. The ENZ approach is one of a aberration retrieval method for which numerous approaches are available. But this approach is new in the sense that it use the highly efficient representation of pupil functions by means of their Zernike coefficients. These coefficients are estimated by using matching procedure in the focal region the theoretical 3D intensity distribution and measured 3D intensity distribution. The algorithm that can be applied more general circumstance such as high-numerical aperture instrument is developed by modifying original ENZ approach. By these scheme, MS windows based GUI program is developed and the good performance is verified with generated 3D beam data.