• Title/Summary/Keyword: 동공크기

Search Result 108, Processing Time 0.03 seconds

Changes in Spherical Aberration and Coma Aberration after Wearing Aspheric Soft Contact Lens in Young Myopes (젊은 성인 근시안에서 비구면 소프트 콘택트렌즈 착용 후 구면수차와 코마수차의 변화)

  • Lim, Dong-Kyu;Kwon, Hyeok;Lee, Koon-Ja
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.469-482
    • /
    • 2018
  • Purpose : We investigated the change of spherical and comma aberrations after wearing aspheric soft contact lens (ASCL) in young myopes. Methods : Fifty young myopes ($23.15{\pm}1.70years$, spherical equivalent: $-2.90{\pm}1.75D$) were recruited and refractive errors were corrected using ASCL (Biotrue, Bausch+Lomb, USA). High order aberrations were measured in the 4 mm pupil size using the wavefront analyze and pupil sizes were measured with a pupillometer at the modes of scotopic condition (light off) at 3.5 m in the 100 lx illuminance condition. Results : Spherical aberrations and coma aberration of the 20s myopes were $0.026{\pm}0.031{\mu}m$ and $0.078{\pm}0.039{\mu}m$ respectively, and $0.019{\pm}0.026{\mu}m$ and $0.082{\pm}0.038{\mu}m$ after ASCL wear that spherical aberration was decreased and coma aberration was increased. However, spherical aberration was decreased in the 68% of the subject have positive spherical aberration, and increased in the 11% of the subject have negative spherical aberration. Coma aberration was increased in the 53% of the subject, did not change in the 19% of the subjects, and decreased in the 28% of the subject. Spherical aberration was not different with the refractive errors in low and moderate myopies, however, coma aberrations was higher in the higher myopes. Conclusion : In a scotopic condition without accommodation stimuli, spherical aberration is decreased after wearing ASCL, however in the subject have negative spherical aberration spherical aberration could be increased, and which is thought to be the influence of contact lens design and pupil size.

Study on Development of Infrared Retinoscope (적외선 검영기의 개발에 관한 연구)

  • Lee, Ik-Han;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.29-34
    • /
    • 2004
  • The aim of this thesis research is to develop equipment measuring refractive state in order to measure the general ocular function using PC-based Foucault Test(Knife Edge Test). The Image of light generated from the reflection of incident light in retina thru Knife Edge Test was photographed using a CCD camera. The resulting image was then analyzed to measure the size of pupil by measuring the diameter of reflected image. The reflection state was judged from the orientation of reflected image and the degree of abnormal reflection was confirmed by measuring the size of second image of reflection. The aberration value was calculated from the magnitude of spherical aberration obtained by comparing the brightness of second reflected image appeared in the opposite direction to the reflected image.

  • PDF

Concealed information test using ERPs and pupillary responses (ERP와 동공 반응을 이용한 숨긴정보검사)

  • Eom, Jin-Sup;Park, Kwang-Bai;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.15 no.2
    • /
    • pp.259-268
    • /
    • 2012
  • In a P300-based concealed information test (P300 CIT), the result of the test is greatly affected by the value of the probe stimulus. With a probe stimulus of low value, the detection rate decreases. The aim of this study was to determine whether the pupil-based concealed information test (Pupil CIT) could be used in addition to the P300 CIT for the probes of low value. Participants were told to choose one card from a deck of five cards (space 2, 3, 4, 5, 6), Then a P300 CIT and a Pupil CIT for the selected card were administered. P300s were measured at 3 scalp sites (Fz, Cz, and Pz), and the pupil sizes of left and right eyes were recorded. The P300 amplitude measured at Fz, Cz, and Pz was significantly different between the probe and irrelevant stimuli. And, in the Pupil CIT, the pupil size was also different between the two stimuli for both eyes. The detection rates of the P300 CIT were 44% at Fz and Cz sites and 36% at Pz site. And the detection rates of the Pupil CIT were 52% for the left eye and 60% for the right eye. There is a trend that the detection rate of the Pupil CIT was higher than that of the P300 CIT, but the difference didn't reach significance partly because of the relatively small sample size. The correlation between the decision based on the P300 CIT and that based on the Pupil CIT was not significant. As a conclusion, it is recommended to use a Pupil CIT instead of a P300 CIT when the value of the probe is low. And a combination of the measures may be superior to either one of them in detection rate.

  • PDF

A Study on Eyes Region Detection on a Mobile Phone (휴대폰에서 눈 영역 검출 연구)

  • Park, Hyun-Ae;Park, Kang-Ryoung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.05a
    • /
    • pp.789-792
    • /
    • 2005
  • 최근 급격히 발전한 휴대폰은 다양한 기능을 가지고 있다. 그 중 디지털 카메라의 기능을 겸비한 휴대폰은 디지털 카메라의 판매량을 앞서고 있고, 메가픽셀의 고화소 디카폰의 개발로 대중화가 더욱 가속화되고 있다. 카메라폰을 응용한 연구분야로는 생체인식기술을 적용할 수 있으며, 본 논문은 제약이 많은 휴대폰 환경에서 홍채인식기술을 적용하기 위한 휴대폰 카메라로 취득된 얼굴영상에서의 눈 영역을 검출하는 방법을 제안한다. 얼굴영상에서 눈은 피부나 머리카락보다 빛에 대한 반사율이 높아 각막에 specular reflection이 생기게 되고, 동공은 눈의 다른 지역에 비해 흑화소가 많다는 특징을 가지고 있다. 이러한 두 가지 특징을 이용하여 동공 후보 영역을 선정하였고, 선정된 이진영상에서 수평 프로파일과 수직 프로파일을 적용하여 동공 후보 영역을 줄이면서 동공의 중심 위치를 검출한다. 본 연구는 휴대폰 환경을 고려하였기 때문에 최소한의 메모리 사용과 적은 연산량을 목표로 하여 눈의 위치를 검출 한다. 실험 결과, 입력 영상 내에 일정크기의 동공영역이 존재할 경우 높은 눈 영역 추출 성공률을 보이며, 본 연구에서 제안한 알고리즘을 실제 휴대폰에서 수행한 결과 평균571.6ms의 시간이 소요됨을 알 수 있었다.

  • PDF

DEM Simulation on the Initiation and Development of Road Subsidence (개별요소법을 활용한 도로함몰 발생과 전개거동 예측)

  • Kim, Yeonho;Park, Seong-Wan
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.7
    • /
    • pp.43-53
    • /
    • 2017
  • Road subsidence, frequently occurring in urban areas, is caused by collapsing of surface layer due to underground cavities followed by a loss of soils. To better understand this phenomenon, the mechanism of cavity formation should be identified firstly. Two kinds of possible subsidence mechanisms were established through previous case studies and the numerical analyses based on Distinct Element Method were conducted for each of these mechanisms. It was confirmed that particle loss and surface settlement can develop differently depending on slit size, void ratio, and particle shape among the various factors influencing the road subsidence. The result demonstrated that the effects of varying cavity diameter and depth could be quantified as a damage chart.

Ocular and Facial Dimension of Primary School (초등학교 학생 눈의 외부측정)

  • Kim, Chang Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.2 no.1
    • /
    • pp.145-148
    • /
    • 1997
  • The mersurements of the inter outer canthal distance (IOCD), inter inner canthal distance(IICD), inter temporal distance (ITD), length palpebral fissure (LPF) and inter pupilly distance(PD) were followed in 852 healthy Korean from 7 to 13 years old. The change of average dimension was 6 mm in PD and 20 mm in ITD during primary school, and then grow up to the dimension of adult. The dimension of ITD and LPF in female was larger than male from 8 to 10 years old. The dimension of LPF increased by change of IOCD more than IICD.

  • PDF

Comparative Study on Growth Stage Aging Changes of The Right and Left Eye Size in Korean (성장기 연령 변화에 따른 좌우안 크기 변화 비교 연구)

  • Park, Soo Bong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.209-216
    • /
    • 1998
  • The purpose of this study was to compare the right and left eye size, distance between two eyes, interpupillary distance on growth stage aging changes in Korean. The author divided into 5 groups according to subject's age(group A : 7~12 years, group B : 13~15 years, group C : 16~18 years, group D : 19~24 years, group E : 25~30 years). The high values of inter outer canthal distance(T) and distance between two eyes(G) were 94.30 mm, 36.66 mm at group B respectively. The ratio of identical eye size was about 10.0% in A, B, C group but 22.7% in E group. P[T-(right eye size + left eye size) / 2] was wider than IPD. Data showed that the difference was 5.72 mm in group B and 1.13 mm in group E. The reason for this is that the pupils are displaced nasally from the center of the limbal ring. This has significant meaning in ophthalmic procedures.

  • PDF

The effect of inter-pupillary distance on stereopsis (동공간 거리가 입체시 지각에 미치는 영향)

  • 감기택;이주환
    • Korean Journal of Cognitive Science
    • /
    • v.14 no.3
    • /
    • pp.37-49
    • /
    • 2003
  • Most 3D display systems heavily depend on binocular disparity to produce 3-dimensional depth of a scene. In principle, the vergence angle of the object on fixation and binocular disparity of non-fixated objects vary with the inter-pupillary distance(IPD) of the observer. However, most stereo systems provide the identical stereo image pairs regardless of the observers' IPD, which may result in variation in the perceived depth. In this study, we manipulated the vergence angle of the fixated object and binocular disparity of the non-fixated object. The range of the individual difference in the perceived depth was found to be increased with the increase of disparity for both the fixated and non-fixated objects, and the individual difference was well fitted by the regression line of the observers' IPD. These results suggest that individual difference in the perceived depth from the identical stereo images should be greatly reduced if the stereo system calibrates the disparity of the object by the observers' IPD in generating the stereo images and the regression line found in this study might be useful in the calibrating the disparity of the images.

  • PDF

Study of Accomodation-lag using Monocular Estimation Method(MEM) (단안평가법(MEM)을 이용한 조절지체에 대한 연구)

  • Park, Eun-kyoo;Seo, Jung-Ick
    • Journal of the Korea society of information convergence
    • /
    • v.6 no.2
    • /
    • pp.51-55
    • /
    • 2013
  • The accomodation is made to see near objects. This accomodation have different characteristics from individual to individual. Difference also occurs accommodation of the theory and real. This is accomodative-lag. Depth of focus directly affects the accomodative-lag. Depth of focus is affected by the refractive power and the size of the pupil. Depth of focus becomes deeper as the size of the pupil is small, the refractive power is increased. The accomodative-lag occur more as depth of focus is deep. In this paper, a study was made of the relationship of the accomodative-lag and refractive power. A Monocular Estimation Method(MEM) use for measuring the accomodative-lag. Results were measured by MEM, it tended to increase the refractive power so as to increase the accodative-lag. The accomodative-lag amount was measured at 0.51D. Men were measured at 0.52D, women were measured at 0.49D. The accomodative-lag by gender tended also increases the amount of refractive power increases.

  • PDF

Development of Videooculograph for Vestibular Function Test (전정 기능 평가를 위한 영상 안구 운동 측정 시스템의 개발)

  • 김수찬;남기창;이원선;김덕원
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.3
    • /
    • pp.189-198
    • /
    • 2003
  • Videooculography (VOG) is one of the eye-movement measurement methods used for objective evaluation of vestibule -ocular reflex. A key feature of VOG is to estimate accurately the center of pupil and ocular torsion with being less influenced by the upper eyelid droop, eyelashes, corneal reflection, and eye blinks. Especially, it Is important to find the accurate center of the pupil in 3-D VOG because the inaccurate pupil center causes significant errors on measuring torsional eye movement. A new algorithm was proposed to find the center of pupil which is a little influenced by factors mentioned above. In this study, real time three-dimensional VOG which can measure horizontal, vortical, torsional eye movements, and the diameter of pupil was implemented using the proposed method.