• Title/Summary/Keyword: 동결과 융해

Search Result 847, Processing Time 0.03 seconds

Performance Evaluation of Fiber-Reinforced Concrete Compression Members Transversely Constrained by BFRP (BFRP로 횡구속된 섬유 보강 콘크리트 압축부재의 성능평가)

  • Lee, Gyeong-Bok;Lee, Sang-Moon;Jung, Woo-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.5
    • /
    • pp.607-616
    • /
    • 2022
  • Corrosion and degradation of reinforced structures due to abnormal climates and natural disasters further accelerate the aging of structures. Coping with the decrease in structure performance, many old structures are being repaired and reinforced with low-weight and high-strength materials such as glass fiber composite material (GFRP). To further contribute, this paper focus on a more economical and eco-friendly material, basalt fiber composite (BFRP), which provide a more effective lateral constraint effect for seismic reinforcement. The main variables considered in this study are the curing temperature during the manufacturing of BFRP and the material characteristics of the target concrete member. The lateral constraint reinforcement effect was investigated through the evaluation of the performance of normal concrete and those with improved durability through fiber reinforcement. The reinforcement effect was 3.15 times for normal concrete and 3.72 times for fiber reinforced concrete, and the difference in reinforcement effect due to the improvement of the durability characteristics of the compression member was not significant. Lastly, the performance of the BFRP was compared with the results of the GFRP reinforcement from the previous study. The effect of the BFRP reinforcement was 1.18 times better than that of the GFRP reinforcement.

Durability Properties of Ultra Rapid Hardening Mortar Produced with Alumina-based Binder for Repairing Sewage Treatment Pipes (하수관거 보수용 알루미나계 결합재 초속경 모르타르의 내구 특성)

  • Eun-Ho, Kim;Byung-Jae, Lee;Sun-Mok, Lee;Yun-Yong, Kim
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.4
    • /
    • pp.482-488
    • /
    • 2022
  • In this study, the durability of ultra rapid hardening mortar for sewage pipe was evaluated by type of mortar binder. As a result of analyzing the internal structure for each type of mortar, it was confirmed that Al2(OH)3 was generated in the internal structure of the CAC-based mortar, and its corrosion resistance was superior to that of other types of mortar. As a result of the compressive strength test, OPC had the tsmallest strength, followed by CAC100 > CAC100P > CAC80. This trend was similar to the previous study results. Chloride ion penetration resistance and freeze-thaw test showed similar trends. That is, CAC and C12A7 were better than OPC, and CSA was worse than OPC. This is mostly beacuse of cracks caused by expansion of CSA-based mortar. CAC100P mix showed the best chemical resistance. It is thought that this is because the alumina gel formed inside the mortar and the polymer combine to make the internal structure more dense.

Review of Adequacy for On-Site Application of Concrete Freeze-Thaw Damage Evaluation Method Using Surface Rebound Value (표면반발경도 활용 콘크리트 동해손상 판정법의 현장 적용 적정성 검토)

  • Ji-Sun, Park;Jong-Suk, Lee
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.4
    • /
    • pp.539-546
    • /
    • 2022
  • The current 「Detailed guidelines for the safety and maintenance of facilities (performance Evaluation)」 prescribes that the durability of surface concrete is evaluated by comparing the measuring the surface rebound value between sound parts and non-sound parts that have surface damage due to winter rain or leakage on concrete. However, this evaluation method was proposed by analyzing the correlation with an experimental DB obtained under freeze-thaw simulation promoting the environment without reviewing on-site applicability. Therefore, this study reviewed on-site application appropriateness of the concrete freeze-thaw damage evaluation method for the 21 concrete bridges in Korea. From the results, it was clearly confirmed that there was a difference in the surface rebound value between the sound part and the non-sound on the concrete surface; the current evaluation method is considered appropriate for application at the site. In addition, the necessity of adding a specific method and a measurement position of surface rebound value were also analyzed, and the effectiveness of the current evaluation method was also analyzed when targeting the entire concrete bridge, not the evaluation of some sections.

An Investigation on the Long Term Durability of High-strength Shotcrete Using Field and Combined Deterioration Test (현장실험과 복합열화시험을 통한 고강도 숏크리트의 장기내구성 검토)

  • Ma, Sang-Joon;Choi, Jae-Seok;Ahn, Kyung-Chul;Kim, Sun-Myung;Kim, Dong-Min
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.10
    • /
    • pp.77-91
    • /
    • 2006
  • Domestic practices in shotcrete use have developed in many respects even now, but it still has issues about material, construction, quality standard and so on. In overseas, the construction using high strength shotcrete with $39.2{\sim}58.8 MPa$ of compressive strength is becoming common based on the shotcrete technology of high strength and durability. However, domestic shotcrete design strength is low at around 20.6 MPa of compressive strength and a long term durability is also insufficient. In this paper, field tests using high-quality additives and accelerators were performed to obtain the improvement of shotcrete strength and EFNARC standard was used to evaluate the field test results. In addition, deterioration test combined with the freezing-thawing and carbonation was also performed in order to investigate a long-term durability of high-strength shotcrete. As a result of the field test, the promotion ratio of early strength was $90{\sim}97%$ in case of using alkali-free accelerators. And the compressive strength of the shotcrete using Micro-silica fume was $45.2{\sim}55.8MPa$ and flexible strength was $5.01{\sim}6.66MPa$, so the promotion ratio of strength was $37{\sim}79%$ and $17{\sim}61%$ respectively. The promotion effect of strength by silica fine additives ratio of $7.5{\sim}10%$ for cement mass was much superior to the other cases. It was especially examined that using Micro-silica fume reduced deterioration due to mixed steel fiber and improved a long-term durability of shotcrete.

Revision of Repair Materials Performance Requirement for Concrete Structures (콘크리트 구조물 단면복구공사 보수재료 품질기준개선)

  • Lee, Il Keun;Kim, Ki Hwan;Kim, Hong Sam;Yun, Sung Hwan;Kim, Woo Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.9-20
    • /
    • 2023
  • For highway concrete structures, the deterioration of the structure is accelerated due to the increase in the use of deicing materials, and sectional repair work is being frequently carried out to restore performance. However, after the repair work, re-damage such as cracks, delamination, and poor bond performance is exhibited in the repaired sectional area. In this study, overseas repair material requirements were first analyzed, and present domestic requirements were improved repair material performance through field surveys of common concrete structures, laboratory experiments, and test construction on a disused concrete bridge. In addition, performancebased quality requirements were presented so that all materials that meet the required performance can be applied, and different test methods for each material were unified into concrete test methods for consistent test results analysis. The considered performance requirements were compression strength, bending strength, and bond strength for structural properties, and length change rate, crack resistance, thermal expansion coefficient, and elasticity coefficient were for dimensional behavior. For resistance to chloride penetration resistance and freeze-thaw resistance were presented as durability. The proposed requirements for concrete repair materials are expected to contribute to the improvement of the quality of concrete sectional repair work in Korea.

Preservation of Strawberries and Cucumbers Packaged by Low density polyethylene film impregnated with antimicmbial agent, Scutellariae baicalensis extract (황금추출물을 함유한 항균성 포장필름을 이용한 딸기와 오이의 저장효과)

  • 정순경;조성환
    • Food Science and Preservation
    • /
    • v.9 no.3
    • /
    • pp.271-276
    • /
    • 2002
  • To develop a wrapping film, which suppresses the microbial decay through the storage and prolongs the selflife of fruits and vegetables, the antimicrobial packaging films were prepared and applied to the preservation of strtwberries and cucumbers. Low density polyethylene(LDPE) film of 50㎛ thickness was faricated with 1% of Scutellariae baicalensis extract. The LDPE film impregnated with Scutellariae baicalensis extract showed antimicrobial activity on the disk test against Bacillus cereus, Escherchia coli and Fusarium sp.. The antimicrobial film changed the color and light transmittance, but did not affect heat shrinkage, mechanical tensile strength and wattability. Strawberries and cucumbers were separately wrapped with packaging films in the state of closely-adhered packaging as well as modified atmosphere packaging(MAP). The wrapped strawberries and cucumbers were stored for 21 days at 5$\^{C}$ and for 40 days at l0$\^{C}$, respectively. For the packaged strawberries and cucumbers at 5$\^{C}$ and 10$\^{C}$, the LDPE film impregnated with Scutellariae baicalensis extract showed the reduced growth of total aerobic bacteria, molds and yeasts and did not give any negative effect on other quality attributes during storage in comparison with conttrol film without any additive.

Embryo Transfer with Sex-Determined Hanwoo Embryos Produced by In-vitro Fertilization (성감별된 한우 체외수정란의 수정란 이식)

  • 김용준;이창민;정구남;이해리;조성우;김용수;신동수;홍유미;유일정
    • Journal of Embryo Transfer
    • /
    • v.18 no.2
    • /
    • pp.97-108
    • /
    • 2003
  • In-vitro fertilized Hanwoo embryos were biopsied for sex determination by PCR. Biopsied embryos were incubated for 1∼2 hours for the recovery. Those sexed Hanwoo embryos were transferred to 49 Hanwoo and 16 Holstein recipients from February 2000 to February 2001. Of 65 recipients, 14 cows(12 Hanwoo and 2 Holstein) delivered the same offspring as sex-determined by PCR, therefore the conception rate was 21.5%. 1. Total 65 embryos(male 35, female 30) were transferred to recipients, and 14 calves (male 6, female 8) were delivered. In comparison between sex by PCR method and sex of calves born after embryo transfer, the accuracy of sex determination was 100.0%. 2. The conception rate after transfer with biopsied embryo between Hanwoo and Holstein was 24.5% and 12.5% 3. The conception rate after transfer with biopsied embryo between fresh and frozen-thawed embryos was 23.5% and 14.3%. 4. The conception rate according to the season when embryo was transferred was 11.8, 29.4, 23.5 and 20.0% for spring, summer, autumn and winter, respectively. 5. The conception rate according to embryo quality after biopsy was 41.7, 30.0 and 0.0% for excellent, good and fair quality. 6. The conception rate according to thickness of uterine horn was 71.4, 18.9, 11.8 and 0.0% for 0, +, ++ and +++ thickness. 7. The conception rate according to the site in the uterine hem where embryo was put was 30.0, 20.0 and 10.0% for cranial, mid, and caudal part of uterine horn. 8. The conception rate according to the quality of corpus luteum ipsilateral to the uterine horn where embryos was transferred was 41.2, 14.3 and 15.4% for excellent, good and fair quality. 9. The conception rate according to the time required for embryo transfer was 18.2, 30.0, 30.0, 0.0 and 25.0% for 10, 15, 20, 25 and 30 minutes. 10. The conception rate according to parity of recipients was 26.5, 19.1, 14.3 and 0.0% for the primiparous, the 2nd parous, the 3rd parous and the 4th parous recipients. These results indicated that fresh embryos are more demanded than frozen-thawed embryos for good conception rate in embryo transfer with biopsied-sexed embryo. Also, it was indicated that we should consider embryo-recovering condition, recipient's uterine thickness, transfer site in uterine horn, quality of corpus luteum, time required for transfer and parity of recipient to achieve good conception rate in ET with biopsied-sexed embryos.

Analysis of Semen Parameters, Sperm Activity, and Fertility of Somatic Cell Cloned Hanwoo Bulls (체세포 복제 한우 수소의 정액 성상, 정자의 활동성 및 수정 능력 분석)

  • Bae, Seong-Hoon;Hwang, Seong-Soo;Yang, Byong-Chul;Go, Yeoung-Kyu;Kim, Dong-Hoon;Im, Gi-Sun;Choi, Hwa-Sik;Jin, Dong-Il;Yang, Boh-Suk;Seong, Hwan-Hoo
    • Reproductive and Developmental Biology
    • /
    • v.31 no.3
    • /
    • pp.139-143
    • /
    • 2007
  • This study was performed to investigate the reproductive characteristics of the cloned Hanwoo bulls produced by SCNT. The semen ejaculated from the cloned bulls (C-38 and C-39) and normal Hanwoo bull was properly measured the volume, the number of sperm, and the viability of frozen-thawed sperm. The sperm activity was analyzed using computer assisted sperm analysis (CASA). To analyze fertilizing ability of the cloned bulls, in vitro fertilization and artificial insemination were performed using the frozen-thawed semen. There were no differences in semen volume, sperm concentration, and the viability of frozen-thawed sperm between cloned bulls and normal bull. The difference was statistically significant in total motility, curvilinear velocity (VCL), straight-line velocity (VSL), and average-path velocity (VAP) of both cloned bulls compared to those of normal Hanwoo bull, respectively (p<0.05). The cleavage and blastocyst development rate were not different between the groups. five cloned cows were artificially inseminated using the frozen-thawed semen of C-38, two of them became pregnant. Two second generation calves (one male and one female) were produced. Based on these results, the cloned Hanwoo bulls showed normal reproductive abilities of semen parameters and sperm activity to their comparators and produced cloned calves, although there are some individual differences on the parameters.

Studies on the Viability of Short-preserved Whole Semen and Frozen Semen in Small Species Dogs (소형 개 정액의 단기보존과 동결보존후의 생존성에 관한 연구)

  • 김용섭;김상근;유상식;정진호
    • Korean Journal of Animal Reproduction
    • /
    • v.23 no.2
    • /
    • pp.127-132
    • /
    • 1999
  • This study was carried out to investigate the general characteristics such as volume, sperm concentration, sperm motility, sperm abnormality on whole semen, removed seminal plasma(RSP) semen and fractional semen of small dogs, and the effect of temperature and preservatio time and cryopreservation on motility of whole and removed seminal plasma semen. Multiple ejaculates were collected from small dogs by the digital manipulation of penis. 1. Average sperm concentration, sperm motility and abnormal sperm rates of whole semen and RSP semen were 5.07$\pm$2.32$\times$10$^{6}$ cells/$m\ell$, 95.42$\pm$2.65%, 4.42$\pm$0.157% and 4.69$\pm$3.27~4.25$\pm$3.65$\times$10$^{6}$ cells/$m\ell$, 91.17$\pm$3.85~88.52$\pm$3.85%, 6.57$\pm$0.43~5.54$\pm$0.52%, respectively. 2. Average semen volume per ejaculate, sperm concentration, sperm motility and abnormal sperm rate of 1st fractional semen were 0.92$\pm$0.7$m\ell$, 4.57$\pm$0.78$\times$10$^{6}$ cells/$m\ell$, 10.72$\pm$3.21% and 5.50$\pm$0.70%. Average semen volume per ejaculate, sperm concentration, sperm motility and abnormal sperm rate of 2nd fractional semen were 2. 14$\pm$0.19$m\ell$, 2.01$\pm$0.12$\times$10$^{6}$ cells/$m\ell$, 95.44$\pm$4.21% and 4.31$\pm$0.53%. Average semen volume per ejaculate, sperm concentration, sperm motility and abnormal sperm rate of 3rd fractional semen were 2.66$\pm$0.23$m\ell$, 2.35$\pm$0.21$\times$10$^{6}$ cells/$m\ell$, 90.71$\pm$2.63%, 6.33$\pm$0.91%, respectively. 3. Motility of whole semen and RSP semen were higher at 2$0^{\circ}C$ than at 4$^{\circ}C$ or 37$^{\circ}C$. When preservation temperature was 2$0^{\circ}C$, sperm motility were 98.32% at 1 hr, 92.15% at 5 hrs, 90.23% at 10 hrs 82.08% at 15 hrs 70.07% at 20 hrs 60.02% at 20 hrs 37.19% at 40 hrs respectively. 4. Average sperm motility of frozen 2nd fraction semen and RSP semen were 33.3$\pm$8.7, 54.7$\pm$9.5%, respectively. Sperm motility was significantly higher in frozen 2nd fraction semen and RSP semen compared with control group.

  • PDF

Variation of Image Analysis Results for Determining the Characteristics of the Air-Void System on Hardened Concrete (콘크리트 공극구조 분석을 위한 화상분석결과의 변동성 분석)

  • Jeon, Sung-Il;An, Ji-Hwan;Lee, Jin-Beom;Kwon, Soo-Ahn
    • International Journal of Highway Engineering
    • /
    • v.13 no.1
    • /
    • pp.157-168
    • /
    • 2011
  • Recently, the cases of freeze-thaw distress on concrete pavement in domestic have been reported periodically. Hereupon, the necessity to establish the standard of spacing factor came to the fore. The test method for analyzing spacing factor is provided in the standard of ASTM C 457. Since researchers tend to judge study results subjectively, the results should be revised throughly. Image analysis program for determining the characteristics of air-void system on hardened concrete identify air void through the difference of a color. The pixel intensity values used in this program have a significant effect on the analysis results. This study compared the automated void count by varying pixel intensity values with the manual void count in order to determine the optimum range of pixel intensity values. Also, this study analyzed the air-void characteristics on eight kinds of concrete mixtures. In this study, it was confirmed that the variation of void counted manually was around 10% from the results of round robin test, and that the optimum range of pixel intensity values is around 80~90. And it was also confirmed that air content (as a whole) was increased generally and spacing factor was decreased by increasing air-entrainer content. But some concrete mixtures showed a tendency that air content was constant and spacing factor was decreased by increasing air-entrainer content. This causes the air entrained by air-entrainer has more influence on spacing factor than air content. Also, the deviation of spacing factor by cutting position of concrete specimen was about 30~100${\mu}m$ because of the limit of 2-D image analysis. The additional study about variation of spacing factor by cutting position of concrete specimen will be performed later.