• Title/Summary/Keyword: 도량형

Search Result 17, Processing Time 0.021 seconds

Development of Calibration System of Helium Permeation Type Standard Leaks (헬륨 투과형 표준리크 교정장치 개발)

  • Hong S.S.;Lim I.T.;Shin Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.4
    • /
    • pp.347-353
    • /
    • 2006
  • A helium permeation type standard leak calibration system has newly developed by using dynamic gas expansion method. The measurement range was extended lower to $10^{-6}$ Pa L/s for participating CCM (Consultative Committee for Mass and Related Quantities) standard leak key comparison. For the system, pressure ratios of high and ultra-high vacuum chamber and porous plug conductance for helium gas were determined. By using the system, a permeation type standard leak of $5.6{\times}10^{-4}$ Pa L/s range was calibrated. The calibration result showed that the difference between standard commercial leak was 11.1 %.

A Empirical Study about the Impact of the Calibration and Measurement Capability(CMC) on Korean Trade (교정 및 측정능력(CMC)이 한국의 무역에 미치는 영향에 관한 실증분석)

  • Park, Jookeun;Han, Seong;Park, Jongseon
    • Journal of Technology Innovation
    • /
    • v.25 no.2
    • /
    • pp.127-152
    • /
    • 2017
  • With the advent of the WTO system in 1995, non-tariff barriers including technical barriers to trade(TBT) has become one of the important issues in world trade order. The purpose of this study is to analyse an impact of the calibration and measurement capabilities(CMC), the degree of equivalence of national measurement standards which is maintained by NMIs to provide governments with a technical foundation for wider agreements related to international trade. The results of the analysis using the gravity model with the proxy of the CMC shows that the CMC has a positive impact on Korean trade. Particularly, it was estimated that the CMC registered by high-income economies has more impact on Korean trade than those by low income economies. This implies that the countries highly dependent upon foreign trade like Korea need to have much more interest in the investment into measurement standards and science which is generally considered to be a public goods.

Historical Changes in Weights and Measures of Herbal Formulas in Medical Classics (기존한약서의 현대적 용량 환산을 위한 도량형의 시대적 변천 고찰)

  • Han, Cheon-Hee;Lee, Soo-Yeon;Kim, Ji-Hoon;Kim, Yun-Kyung
    • Herbal Formula Science
    • /
    • v.25 no.1
    • /
    • pp.103-113
    • /
    • 2017
  • Objectives : Korea and China are applying different conversion standards for weight in traditional medicine books. This study aims to research and suggest how to convert the units of weight in old traditional medicine classics into the contemporary unit of grams. Methods : Historical documents of Korea and China were used to review the process in which weights and measures changed in each country and the manners in which the Chinese units of weight were introduced to Korea. Results : Weights and measures changed with time. They became almost standardized by the period of Song in China, when coins played the most crucial role, and it was introduced to Korea. Donggaryang, the standard container for weights and measures in ancient China, Gaewontongbo, a coin in Tang, Sangpyeongtongbo, a coin in Joseon, and a scale in Joseon were used as strong foundations for conclusion from literature review. Weight of a 1-don(coin) in the time a traditional medicine books were written was used as a unit of weight in those books. Sangpyeongtongbo, a 1-don coin in Joseon, weighs 4 grams on average. Conclusions : Since the current conversion of 1-don coin into 3.75 grams is not supported by literature review, it is suggested that 1-don(coin) as a unit of weight in traditional medicine books of Joseon, may be better converted into 4 grams, while that of China is converted to 3.73 grams.

Survey on Setting New Standards for Estimation of Acupoints in the Upper Limb of Normal Adults (정상(正常) 성인(成人) 남녀(男女) 상지부위(上肢部位)의 실측(實測)을 통한 혈부위(穴部位) 도량형(度量衡)의 기준(基準) 정립(定立))

  • Sung, Byoung-Sik;Kwon, O-Sang;Jeon, In-Suk;Kim, Jae-Hyo;Ahn, Sung-Hun;Sohn, In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.25 no.3
    • /
    • pp.1-14
    • /
    • 2008
  • Objectives : Weights and measures (度量衡) in Korean traditional medicine have been changed in many dynasties and countries. Thus, measurements of chon (寸) and cheok (尺) have been considered as symbolical meaning in recent studies on meridians and acupoints. The present study was made to settle up standard measurement by surveying length of each parts of upper limb as follows. Methods : To calculate length of 1 chon (寸), the length of each part was divided into the numbers of chon (寸) as shwon in ${\ll}$Goldo Hwangjenaegyeong-yeongchu (靈樞 骨度篇)${\gg}$; the chon (寸) length in ${\ll}$Goldo Hwangjenaegyeong-yeongchu (靈樞 骨度篇)${\gg}$ was compared with the chon (寸) length which is calculated by dividing human average hight into 75 chon. Results : Increment of length of 1 chon (寸) did not change as increment of height in subjects. Length of 1 chon (寸) in height is representative of length of 1 chon (寸) in each parts of upper limb. Conclusions : We suggest that most suitable length of 1 chon (寸)for the standard measurement of acupoint location is 2.20 ${\pm}$ 0.17 cm based on length of elbow joint to wrist joint.

  • PDF

Results of Key Comparison on LS1P Microphones (LS1P 마이크로폰 핵심측정표준 국제비교 결과)

  • Suh Jae Gap;Jho Moon Jae;Kwon Hyu-Sang;Suh Sang Joon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.194-201
    • /
    • 2005
  • Since the necessity for the accurate measurement in the field of acoustics, vibration, and ultrasound was internationally increased, CCAUV (Consultative Committee for Acoustics , Ultrasound and Vibration) was created by the CIPM (International Committee for Weights and Measures) in 1998. One of the first activities of CCAUV is the key comparison on 1' standard microphones. The key comparison was done from April. 1999 to April. 2001 and 12 NMIs(National Metrology Institutes) including KRISS (Korea Research Institute of Standards and Science) were participated. The pilot laboratory was the National Physical Laboratory(NPL). The traveling standards were two LSIP(Laboratory Standard 1' Pressure Type) microphones specified in IEC 61094-1 and the calibration frequency ranges covers from 63Hz to 8kHz. In this paper, the analyzed results in the final report were summarized.

New Standards for Measurement in Meridians & Acupoints by Taking the Size of Normal Male Legs (정상 성인 남자(男子) 하지부위(下肢部位)의 수혈(?穴) 정위(定位)를 위한 도량형(度量衡) 산출)

  • Yu, Shin-Jong;Kwon, Oh-Sang;Ahn, Seong-Hoon;Kim, Young-Jin;Kim, Kyung-Sik;Sohn, In-Chul;Kim, Jae-Hyo
    • Journal of Pharmacopuncture
    • /
    • v.13 no.1
    • /
    • pp.93-101
    • /
    • 2010
  • Objective : Standard of measurement in Korean Medicine has been changed in dynasty and location. Thus, cun (寸) and chi (尺) as unit of measurement for meridians and acupoints could be recognized as the length of equally divided portions of a certain long bone or the distance between two anatomical landmarks and as an symbolical meaning to date. The goal of this study is to propose a new standard measurement in the metric system for the relative measurement of cun and chi as unit of measurement for meridians and acupoints in normal male legs. Methods : This study was conducted by gauging each parts of normal male legs in the metric system and comparing to the relative measurement of cun and chi as follows; to calculate 1 cun, the length of each parts was divided into the unit of cun referred to Measurement of the Bone in Neijing Lingshu (靈樞 骨度篇); it was compared the unit of cun referred to Measurement of the Bone in Neijing Lingshu with cun which was calculated by dividing subject's height into 75 cun, respectively. Result : There has no significant difference in length of 1 cun among each leg's areas based on a standard of subject's height. The unit of cun by the metric length in the legs was similar to the unit of cun referred to Measurement of the Bone in Neijing Lingshu based on each subject's height. Conclusion : It is suggested that an unit of cun as the measurement for meridians and acupoints in the male legs should be considered to the ranges from 2.4cm to 2.6cm.

Review on the Ancient korea Length, Weight and Volumetric Measures (고대 한국의 도량형 고찰)

  • 김소보;나영아
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.4 no.1
    • /
    • pp.1-18
    • /
    • 1994
  • This study is designed to delve into the measuring systems of different periods so as to help with more exact representations of cultures of different periods. The basis of the measuring system in china stems from the huangjong (Huangzhong : the yellow bell) of the period of Huangdi, the length of the bell being the width of 90 black millet grains. Do (Du : width) ; 1 bun=the width of one black millet grain, 1 Chon=10 Buns, 1 Chuk=10 Chons, 1 Jang=10 Cheoks, 1 In=10 Jangs. Ryang (Lyang : volume) ; 1 Yak=the weight of 1,200 grains in the yellow bell, 1 Hab=2 Yaks, 1Seung=10 habs, 1 Du=10 Seungs, 1 Gok=10 Dus. Hyung (Hung : weight) ; 12 Jus=the weight of 1 Yak, 1Yang=24 Jus are equal 1 Hab in weight, 1 Geun=16 Ryangs, 1 Jo=30 Geuns, 1 Seo=4 Jo. In the era of Eun (In) it was decided that the 9-chon length of the Yellowbell shall be 1 Cheok. The Cheok of Ju was set at 4/5 of the length of the yellow bell. The Cheok of Ju breaks into Yongjocheok, Joryegicheok, Pogeumcheok. Yongjocheok, arising from Rohbancheok of the Ju period, is part of Gokcheok also used as a measuring tool for wooden works. The Han cheok has the same length as the yellow bell. The Sang Cheok is 4/5 of the length of the yellow bell. The Tang Cheok was originally the same as the Sang cheok but became longer and longer to be the Long cheok (31.3cm). The length-measuring system used in the three-nation era of Korea includes the gijeom cheil (35.52cm), Ju cheok (25.45cm), sunje Cheok (23.5cm), the Long Tang Cehok (29.706 cm), making 10 Bun 1 Chon and 10 Chon 1 Cheok. The volume-measuring system(Seung) was 198.81 ㎤ before 681 BC in the shilla Dynasty and was 596.42 ㎤ after that. In the seventh year of Kng Munjong of the Koryo dynasty the standard measuring system with the Long Tang Cheok as its basis was adopted, and the standard volume-measuring tools were used under the name of Migok, Daesodugok, Mijangdu, (29.706 cm), making 10 Bun 1 Chon and 10 Chon 1 Cheok. The volume-measuring system(Seung) was 198.81㎤ before 681 BC in the shilla dynasty and was 596.42 ㎤ after that. In the seventh year of King Munjong of the Koryo dynasty the standard measuring system with the Long Tang Cheok as its basis was adopted, and the standard volume-measuring tools were used under the name of Migok, Daesodugok, Kijangdu, Habseung and gokseok. The 1 Seung volumes of theses toolas were 596,447,927 and 1053㎤, respectively. were called Migok, Daesodugok, Mijangdu, Habseung and Gokseok, being respectively 596,447,927, 1053 ㎤, respectively. In the Chosun Dynasty the length of the Yeongjocheos was 27.6 cm or 31.220 in the Sejong era, 29.8 from Heonjong through Gojong, and 30.3 cm after the 6th year of King Kwangmu, and the volume of Du(Mal) also changed like 4.121 or 5.964, 5.187, 23.08 $\ell$, and the 1-Jeonjung also changed like 2.66 or bout 4, 3.45, 3.75 in line with the changes of the length system.

  • PDF