• Title/Summary/Keyword: 데이터 호환성

Search Result 483, Processing Time 0.03 seconds

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

Landscape Object Classification and Attribute Information System for Standardizing Landscape BIM Library (조경 BIM 라이브러리 표준화를 위한 조경객체 및 속성정보 분류체계)

  • Kim, Bok-Young
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.51 no.2
    • /
    • pp.103-119
    • /
    • 2023
  • Since the Korean government has decided to apply the policy of BIM (Building Information Modeling) to the entire construction industry, it has experienced a positive trend in adoption and utilization. BIM can reduce workloads by building model objects into libraries that conform to standards and enable consistent quality, data integrity, and compatibility. In the domestic architecture, civil engineering, and the overseas landscape architecture sectors, many BIM library standardization studies have been conducted, and guidelines have been established based on them. Currently, basic research and attempts to introduce BIM are being made in Korean landscape architecture field, but the diffusion has been delayed due to difficulties in application. This can be addressed by enhancing the efficiency of BIM work using standardized libraries. Therefore, this study aims to provide a starting point for discussions and present a classification system for objects and attribute information that can be referred to when creating landscape libraries in practice. The standardization of landscape BIM library was explored from two directions: object classification and attribute information items. First, the Korean construction information classification system, product inventory classification system, landscape design and construction standards, and BIM object classification of the NLA (Norwegian Association of Landscape Architects) were referred to classify landscape objects. As a result, the objects were divided into 12 subcategories, including 'trees', 'shrubs', 'ground cover and others', 'outdoor installation', 'outdoor lighting facility', 'stairs and ramp', 'outdoor wall', 'outdoor structure', 'pavement', 'curb', 'irrigation', and 'drainage' under five major categories: 'landscape plant', 'landscape facility', 'landscape structure', 'landscape pavement', and 'irrigation and drainage'. Next, the attribute information for the objects was extracted and structured. To do this, the common attribute information items of the KBIMS (Korean BIM Standard) were included, and the object attribute information items that vary according to the type of objects were included by referring to the PDT (Product Data Template) of the LI (UK Landscape Institute). As a result, the common attributes included information on 'identification', 'distribution', 'classification', and 'manufacture and supply' information, while the object attributes included information on 'naming', 'specifications', 'installation or construction', 'performance', 'sustainability', and 'operations and maintenance'. The significance of this study lies in establishing the foundation for the introduction of landscape BIM through the standardization of library objects, which will enhance the efficiency of modeling tasks and improve the data consistency of BIM models across various disciplines in the construction industry.

Design and Implementation of Telematics Contents Gateway Based on Interoperability (상호운영성 기반의 텔레매틱스 컨텐츠 게이트웨이 설계 및 구현)

  • Kim, Do-Hyun;Min, Kyoung-Wook;Jang, Byung-Tae;Li, Ki-Joune
    • The KIPS Transactions:PartD
    • /
    • v.14D no.2
    • /
    • pp.249-264
    • /
    • 2007
  • As the need for telematics contents services due to the frequent traveling of people is increasing, it is necessary to provide various telematics contents by connecting and integrating current telematics contents which are collected and provided by each individual data provider. However, it is difficult to integrate or exchange the current telematics contents, because the data providers use different telematics contents models. Therefore, we propose a 'telematics contents gateway(TCG); system, which enables to integrate different telematics contents, so that the contents can be interoperable. The TCG can be a solution for several problems in the current telematics contents providing system. First of all, it has been impossible to search the contents without any information about data providers, because of the absence of metadata in the current systems. For this problem, TCG supports a search function based on a web-service technology. Second, TCG provides a common road network model for interoperability, and the model can be a solution to integrate different road network models into the common model. Moreover, integration algorithm for enhancing the correctness of integration will be proposed. In addition, it is designed by multi threads and multi queue structure. The TCG developed with C# on a windows system has been running and we verified that there was no information loss in the integration process. In addition, the speed of content integration and transfer satisfied the requirement of telematics services providers.

A UTMI-Compatible USB2.0 Transceiver Chip Design (UTMI 표준에 부합하는 USB2.0 송수신기 칩 설계)

  • Nam Jang-Jin;Kim Bong-Jin;Park Hong-June
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.5 s.335
    • /
    • pp.31-38
    • /
    • 2005
  • The architecture and the implementation details of a UTMI(USB2.0 Transceiver Macrocell Interface) compatible USB2.0 transceiver chip were presented. To confirm the validation of the incoming data in noisy channel environment, a squelch state detector and a current mode Schmitt-trigger circuit were proposed. A current mode output driver to transmit 480Mbps data on the USB cable was designed and an on-die termination(ODT) which is controlled by a replica bias circuit was presented. In the USB system using plesiochronous clocking, to compensate for the frequency difference between a transmitter and a receiver, a synchronizer using clock data recovery circuit and FIFO was designed. The USB cable was modeled as the lossy transmission line model(W model) for circuit simulation by using a network analyzer measurements. The USB2.0 PHY chip was implemented by using 0.25um CMOS process and test results were presented. The core area excluding the IO pads was $0.91{\times}1.82mm^2$. The power consumptions at the supply voltage of 2.5V were 245mW and 150mW for high-speed and full-speed operations, respectively.

An Analysis of a Request for the Development of Computer Application Technology in an Architectural Construction Management System (건축공정 관리시스템의 전산적용 최적화를 위한 시스템 개발 요구 분석)

  • Kwon, Choon-An;Ji, Suk-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.6
    • /
    • pp.567-575
    • /
    • 2011
  • With the development of construction information, a computerization tool for architectural process control is a necessary tool. However, the reality is that the conditions and understanding of users are not sufficient to fully utilize such a tool. In particular, it was analyzed that the reason for the negative feedback from hands-on workers regarding the current process control information system is that there is a difficulty in accessing the system for users that are not process and planning experts, due to a lack of information and technical contents at the phase of control and planning prior to the process plan. Therefore, the demands of users and a direction for the improvement of a system in terms of optimizing process control computerization were investigated, with the aim of addressing the disadvantages of the existing system and developing a professional system that is specialized in the construction industry. Therefore, it is necessary to construct an integrated WBS (IWBS) that combines WBS with CBS, and subsequently, it is judged that the most important aspect is the integrated technology of compatibility and operation of data that is linked with OBS. The process information must then deal with the changing information; in other words, the amount of construction, construction cost, and the required construction period etc., by coding data into a 4-unit index, such as a project unit (WBS Level 1), a project facility unit (WBS Level 2), a management department unit (OBS Level 1), and a control manager unit (OBS Level 2). After that, it was found that it is necessary to develop a computer system to consistently integrate process information into a management department.

Design and Implementation of Picture Archiving and Communication System Component using the RFID for Mobile Web Environments (모바일 웹 환경을 위한 의료영상저장전송시스템 컴포넌트의 설계 및 구현)

  • Kim Chang-Soo;Yim Jae-Hong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.6
    • /
    • pp.1124-1131
    • /
    • 2006
  • The recent medical treatment guidelines and the development of information technology make hospitals reduce the expense in surrounding environment and it requires improving the quality of medical treatment of the hospital. Moreover, MIS, PACS(Picture Archiving and Communication System), OCS, EMR are also developing. Medical Information System is evolved toward integration of medical IT and situation is changing with increasing high speed in the ICT convergence. Mobile component refers to construct wireless system of hospital which has constructed in existing environment. Through RFID development in existing system, anyone can log on easily to internet whenever and wherever. It is the core technology to implement automatic medical processing system. This paper provides a basic review of RFID model, PACS application component services. In addition, designed and implemented database server's component program and client program of mobile application that recognized RFID tag and patient data in the ubiquitous environments. This system implemented mobile PACS that performed patient data based db environments, and so reduced delay time of requisition, medical treatment, lab.

Design and Implementation of Mobile Medical Information System Based Radio Frequency IDentification (RFID 기반의 모바일 의료정보시스템의 설계 및 구현)

  • Kim, Chang-Soo;Kim, Hwa-Gon
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.317-325
    • /
    • 2005
  • The recent medical treatment guidelines and the development of information technology make hospitals reduce the expense in surrounding environment and it requires improving the quality of medical treatment of the hospital. That is, with the new guidelines and technology, hospital business escapes simple fee calculation and insurance claim center. Moreover, MIS(Medical Information System), PACS(Picture Archiving and Communications System), OCS(Order Communicating System), EMR(Electronic Medical Record), DSS(Decision Support System) are also developing. Medical Information System is evolved toward integration of medical IT and situation si changing with increasing high speed in the ICT convergence. These changes and development of ubiquitous environment require fundamental change of medical information system. Mobile medical information system refers to construct wireless system of hospital which has constructed in existing environment. Through RFID development in existing system, anyone can log on easily to Internet whenever and wherever. RFID is one of the technologies for Automatic Identification and Data Capture(AIDC). It is the core technology to implement Automatic processing system. This paper provides a comprehensive basic review of RFID model in Korea and suggests the evolution direction for further advanced RFID application services. In addition, designed and implemented DB server's agent program and Client program of Mobile application that recognized RFID tag and patient data in the ubiquitous environments. This system implemented medical information system that performed patient data based EMR, HIS, PACS DB environments, and so reduced delay time of requisition, medical treatment, lab.

  • PDF

Performance Analysis of the Encryption Algorithms in a Satellite Communication Network based on H-ARQ (H-ARQ 기반 위성통신망에서 암호화 알고리즘에 따른 성능 분석)

  • Jeong, Won Ho;Yeo, Bong-Gu;Kim, Ki-Hong;Park, Sang-Hyun;Yang, Sang-Woon;Lim, Jeong-Seok;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • Since the broadcast message in satellite signals the security of the data is extremely poor compared to other communication technologies such as the broadcast signal. Thus, encryption of the communication satellite has become a very important issue, an analysis of the communication performance of a general service is always required. In this paper, In order to analyze the encrypted communication the turbo code in an IP-based satellite communication applies the code rate compatible punctured and The wireless channel in consideration of the actual satellite communication was constructed by placing a weight on the Rayleigh fading and the Rician fading two channels. Retransmission-based error control scheme were constructed in the best performance of H-ARQ Type-II, III scheme of a number of ways that are recently considered. we analyzed the effects of normal service against a satellite communication network The security services were configured with encryption algorithms AES, ARIA (CTR, CBC mode).

Enhanced-x VSB System Development for Next Generation Terrestrial DTV RF Transmission (차세대 지상파 DTV 전송시스템 개발)

  • Kim, Sung-Hoon;Lee, Jea-Young;Lee, Soo-In;Ahn, Chie-Teuk;Kim, Ki-Doo
    • Journal of Broadcast Engineering
    • /
    • v.12 no.2
    • /
    • pp.120-127
    • /
    • 2007
  • In this paper, we describe a new 1/4 rate robust modulation techniques for Enhanced-x VSB system which is fully backward compatible with ATSC 8-VSB standard. 1/4 rate mode Enhanced-xVSB system provides broadcasters with a wide choice of trade-offs of data rate vs amount of robustness of enhanced data for pedestrian/mobile services. Lab test results of proposed Enhanced-x VSB 1/4 rate mode robust stream are a significantly improved multipath as well as AWGN reception performance for Enhanced-x VSB receiver. We suggest an Enhanced-x VSB terrestrial broadcasting system for ATSC HDTV and pedestrian/portable TV simultaneous broadcasting service providing.

Implementation of the wearable PTT measurement system for health monitoring during daily life (일상생활 건강 모니터링을 위한 착용형 PTT 측정 시스템의 구현)

  • Ye, Soo-Young;Noh, Yun-Hong;Jeong, Do-Un
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.1
    • /
    • pp.220-226
    • /
    • 2011
  • Device of the ECG and pulse signal was made to measure PTT signal using non-invasive method and possible to wearable. PTT alterations were observed according to position change using implemented system.It was needed to ECG and pulse to detect the PTT, used the photoplethymorgraphy appeared to change the blood volume. And also wireless sensor node which was able to Zigbee compatibility was used to transfer the detected ECG and pulse signal to PC. Noise was removed from transit data and algorithm was applied to calculate the PTT. After the evaluation of both the conventional measuring systems and the proposed photoplethymography measuring system, a highly effective and efficient formation and distribution sequences were found within the proposed photoplethymography measuring system.