Browse > Article
http://dx.doi.org/10.6109/jkiice.2011.15.1.220

Implementation of the wearable PTT measurement system for health monitoring during daily life  

Ye, Soo-Young (동서대학교)
Noh, Yun-Hong (동서대학교)
Jeong, Do-Un (동서대학교)
Abstract
Device of the ECG and pulse signal was made to measure PTT signal using non-invasive method and possible to wearable. PTT alterations were observed according to position change using implemented system.It was needed to ECG and pulse to detect the PTT, used the photoplethymorgraphy appeared to change the blood volume. And also wireless sensor node which was able to Zigbee compatibility was used to transfer the detected ECG and pulse signal to PC. Noise was removed from transit data and algorithm was applied to calculate the PTT. After the evaluation of both the conventional measuring systems and the proposed photoplethymography measuring system, a highly effective and efficient formation and distribution sequences were found within the proposed photoplethymography measuring system.
Keywords
PTT(Pulse Transit time); ECG(Electrocardiogram);
Citations & Related Records
연도 인용수 순위
  • Reference
1 Jochanan E. Naschitz, Stanislas Bezobchuk, Renata Mussafia-Priselac, "Pulse transit time by R-wave-gated infrared phtoplethysmotraphy : review of the literature and personal experience", Journal of Clinical Monitoring and Computing, vol.18, pp. 333-342, 2004.   DOI   ScienceOn
2 S. C. Millasseau, R. P. Kelly, J. M. Ritter, et al., "Determination of age-related increases in large artery stiffness by digital pulse contour analysis", Clinical Science, vol. 103, pp.371-377, 2002.   DOI
3 J. Oliver and D. J. Webb, "Noninvasive Assessment of Arterial Stiffness and Risk of Atherosclerotic Events", Arterioscler Thromb Vasc Biol, vol. 23, pp.554-556, 2003.   DOI   ScienceOn
4 P. Salvi, G. Lio, C. Labat, et al., "Validation of a new non-invasive portable tonometer for determining arterial pressure wave and pulse wave velocity: the Pulse Pen device", J. Hypertens, vol. 22, pp.2285- 2293, 2004.   DOI   ScienceOn
5 P. J. Chowienczyk, R. P. Kelly, H. MaxCallum, et al.,"Photoplethysmographic Assessment of Pulse Wave Reflection", J Am Coll of Cardiol, vol. 34, no. 7, pp.2007-14, 1999.   DOI   ScienceOn
6 Ezzati M, Lopez AD, Rodgers A, Murray CJL. "Comparative quantification of health risks: global and regional burden of disease attributable to selected major risk factors," Geneva: World Health Organization, 2004.
7 N. K. Gopaul, M. D. Manraj, A. Hebe, et al., "Oxidative stress could precede endothelial dysfunciton and insulin resistance in Indian Mauritians with impaired glucose metabolism", Diabetologia, vol. 44, pp.706-712, 2001.   DOI   ScienceOn
8 통계청, "만성질환 현황"