The evaluation for Clinical usefulness and Safety of Sirolimus-eluting stent and Paclitaxel-Eluting Stents In Patients With Acute Myocardial Infarction (급성심근경색증 환자의 일차적 관동맥 스텐트 삽입술 시 삽입된 Sirolimus-eluting stent 와 Paclitaxel-eluting stent의 임상적 안정성 및 유용성 평가)

  • Min, Gye-Sik;Han, Man-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.5-10
    • /
    • 2012
  • There is a still unsettled issue about the comparison of long-term clinical effects between sirolimus-(SES) and paclitaxel-eluting stents (PES) for the patients with acute myocardial infarction (AMI). Therefore, we performed a retrospective analysis to evaluate the 4-year clinical outcome of SES as compared with PES after percutaneous coronary intervention (PCI) in patients with AMI. From January 2004 to August 2006, all consecutive patients with acute ST-segment elevation myocardial infarction (STEMI) underwent primary PCI and acute NSTEMI underwent PCI by implantation either SES or PES were enrolled. The occurrence of death, cardiac death, recurrent infarction, target vessel revascularization (TVR) and stent thrombosis were analyzed. The composite of major adverse cardiac events (MACE; death, recurrent infarction and TVR) were also analyzed. During the study period, total 668 AMI patients had visited. Of them, total 522 patients (299 with SES and 223 with PES) were enrolled. During 4-year clinical follow-up, there were similar occurrences of death ($18.3{\pm}3.0%$ vs. $14.6{\pm}2.2%$, p=0.26), cardiac death ($11.2{\pm}2.6%$ vs. $6.8{\pm}1.52%$, p=0.39), re-infarction ($6.4{\pm}1.8%$ vs. $3.3{\pm}1.1%$, p=0.31), and stent thrombosis ($5.4{\pm}1.7%$ vs. $3.2{\pm}1.1%$, p=0.53) between the two groups, consecutively. The occurrences of TVR ($10.0{\pm}3.0%$ vs. $4.0{\pm}1.2%$, p=0.008) and MACE ($29.4{\pm}3.5%$ vs. $19.4{\pm}2.5%$, p=0.003) were significantly higher in patients treated with PES than SES. In AMI patients treated with either SES or PES implantation, SES had a significantly lower risk of TVR and MACE during 4-year clinical follow-up. Rates of death, cardiac death or recurrent infarction, and stent thrombosis were similar.

Performance Measurement of Diagnostic X Ray System (진단용 X선 발생장치의 성능 측정)

  • You, Ingyu;Lim, Cheonghwan;Lee, Sangho;Lee, Mankoo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.447-454
    • /
    • 2012
  • To examine the performance of a diagnostic X-ray system, we tested a linearity, reproducibility, and Half Value Layer(HVL). The linearity was examined 4 times of irradiation with a given condition, and we recorded a level of radiation. We then calculated the mR/mAs. And the measured value should not be more than 0.1. If the measured value was more than 0.1, we could know that the linearity was decreased. The reproducibility was analyzed 10 times of irradiations at 80kVp, 200mA, 20mAs and 120kVp, 300mA, 8mAs. The values from these analyses were integrated into CV equation, and we could get outputs. The reproducibility was good if the output was lower than 0.05. HVL was measured 3 times of irradiation without a filter, and we inserted additional HLV filters with 0, 1, 2, 4 mm of thickness. We tested the values until we get the measured value less than a half of the value measured without additional filter. We tested the linearity, the reproducibility, and HVL of 5 diagnostic X-ray generators in this facilities. The linearity of No. 1 and No. 5 generator didn't satisfy the standard for radiation safety around 300mA~400mA and 100mA~200mA, respectively. HVL of No.1 generator was not satisfied at 80kVp. The outputs were higher in the three-phase equipment than the single-phase equipment. The old generators need to maintain and exchange of components based on the these results. Then, we could contribute to getting more exact diagnosis increasing a quality of the image and decreasing an expose dose of radiation.

Evaluation of Usefulness of SPIO (Superparamagnetic iron oxide) Contrast Agent in MRCP (Magnetic resonance cholangiopancreatography) (자기공명 담도췌장조영술에서의 SPIO 조영제의 유용성 평가)

  • Hong, In-Sik;Lee, Hae-Kak;Cho, Jae-Hwan;Kim, Hyeon-Ju;Jang, Hyun-Cheol;Park, Cheol-Soo;Lee, Sun-Yeob;Goo, Eun-Hoe;Dong, Kyung-Rae;Cho, Moo-Seong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.143-148
    • /
    • 2011
  • The purpose of this study was to examine the usefulness of SPIO contrast agent in Magnetic Resonance Cholangiopancreatography (MRCP) by performing a quantitative comparative analysis in patients undergoing MRCP for gallbladder stones with and without oral injection of SPIO (Superparamagnetic iron oxide) contrast agent. The subjects were 36 patients undergoing MRCP for suspected gallbladder stones between January 2009 and February 2010 and they were divided into halves to compare the two groups of with and without SPIO agent. For each subject in both the injected and non-injected group, T2-weighted images on a 1.5T MR scanner were obtained, using both the breath-holding and respiratory-triggered methods, respectively. The following regions were measured; for breath-hold T2-weighted images, the measurement regions were located at the central part of the gallbladder, and the areas 15 mm away from its center, toward the front and back, respectively, which were chosen to include surrounding tissues, while for respiratory-triggered T2-weighted images, at the central part of the gallbladder, and segment 5 and 6 of liver. In a quantitative analysis, average signal to noise ratio (SNR) in each of regions of interest (ROI) for each group were calculated and then average contrast to noise ratio (CNR) in each of ROI were obtained by using the SNR in the gallbladder as the basis to compare and analyze the values between the two groups. The CNR were higher for the injected group in those regions.

The Design and Fabrication of Conversion Layer for Application of Direct-Detection Type Flat Panel Detector (직접 검출형 평판 검출기 적용을 위한 변환층 설계 및 제작)

  • Noh, Si-Cheol;Kang, Sang-Sik;Jung, Bong-Jae;Choi, Il-Hong;Cho, Chang-Hoon;Heo, Ye-Ji;Yoon, Ju-Seon;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.73-77
    • /
    • 2012
  • Recently, Interest to the photoconductor, which is used to flat form X-ray detector such as a-Se, $HgI_2$, PbO, CdTe, $PbI_2$ etc. is increasing. In this study, the film layer by using the photoconductive material with particle sedimentation was fabricated and evaluated. The quantization efficiency of the continuous X-ray with the 70 kVp energy bandwidth was analyzed by using the Monte Carlo simulation. With the results, the thickness of film with 64 % quantization efficiency was 180 ${\mu}m$ which is similar to the efficiency of 500 ${\mu}m$ a-Se film. And $HIg_2$ film has the high quantization efficiency of 74 % on 240 ${\mu}m$ thickness. The electrical characteristics of the 239 ${\mu}m$ $Hgl_2$ films produced by particle sedimentation were shown as very low dark current(under 10 $pA/mm^2$), and high sensitivity(19.8 mC/mR-sec) with 1 $V/{\mu}m$ input voltage. The SNR, which is influence to the contrast of X-ray image, was shown highly as 3,125 in low driving voltage on 0.8 $V/{\mu}m$. With the results of this study, the development of the low-cost, high-performance image detector with film could be possible by replacing the film produced by particle sedimentation instead to a-Se detector.

The Average Glandular Dose in Mammography and Quality Control of the Equipment Status (유방촬영검사에서 평균유선선량과 장치의 품질관리 실태)

  • Jung, Hong-Ryang;Hwang, Su-Lyun;Ha, Bon-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.111-120
    • /
    • 2011
  • A purpose of study is to develop optimization and radiation dose exposure reference level by measuring actual radiation dose in condition of quality control of mammography equipment for 39 clinics. The result were as follows. First, we measured T-test separating radiology from general clinic. According to the test, mAs was measured at average 78.58 mAs; radiology at 80.16 mAs and general clinic at 77.22 mAs. And, kerma rate was measured at average 7.71 mGy/mR; radiology at 8.94 mGy/mR and general clinic at 6.66 mGy/mR. HVL was measured at average 0.42 mmAl; radiology at 0.40 mmAl and general clinic at 0.43 mmAl. Average glandular dose was measured at average 1.14 mGy; radiology at 1.09 mGy and general clinic at 1.19 mGy. Second, we measured value of mAs, HVL, processing method and so on dividing two groups. And, we compared and analyzed average value measured using T-test. As a result, there was significance level in SID(P<0.05). There was significance level in mAs(P<0.05). Because processor was measured at 1.00 mGy and CR at 1.17 mGy according to the processing method of radiology. Third, according to the correlation analysis, radiology had significance level between average glandular dose and mAs and general clinic had significance level between average glandular dose and SID(P<0.05). Forth, as a result of regression analysis, mAs affected 22.7%t of average glandular dose and SID affected 21.7% of average glandular dose, which had significance level(P<0.05). And, mAs affected 29.0% of average glandular dose in radiology and SID affected 29.1% of average glandular dose in general clinic, which was most influential.

Evaluation of Approximate Exposure to Low-dose Ionizing Radiation from Medical Images using a Computed Radiography (CR) System (전산화 방사선촬영(CR) 시스템을 이용한 근사적 의료 피폭 선량 평가)

  • Yu, Minsun;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.455-464
    • /
    • 2012
  • This study suggested evaluation of approximately exposure to low-dose ionization radiation from medical images using a computed radiography (CR) system in standard X-ray examination and experimental model can compare diagnostic reference level (DRL) will suggest on optimization condition of guard about medical radiation of low dose space. Entrance surface dose (ESD) cross-measuring by standard dosimeter and optically stimulated luminescence dosimeters (OSLDs) in experiment condition about tube voltage and current of X-ray generator. Also, Hounsfield unit (HU) scale measured about each experiment condition in CR system and after character relationship table and graph tabulate about ESD and HU scale, approximately radiation dose about head, neck, thoracic, abdomen, and pelvis draw a measurement. In result measuring head, neck, thoracic, abdomen, and pelvis, average of ESD is 2.10, 2.01, 1.13, 2.97, and 1.95 mGy, respectively. HU scale is $3,276{\pm}3.72$, $3,217{\pm}2.93$, $2,768{\pm}3.13$, $3,782{\pm}5.19$, and $2,318{\pm}4.64$, respectively, in CR image. At this moment, using characteristic relationship table and graph, ESD measured approximately 2.16, 2.06, 1.19, 3.05, and 2.07 mGy, respectively. Average error of measuring value and ESD measured approximately smaller than 3%, this have credibility cover all the bases radiology area of measurement 5%. In its final analysis, this study suggest new experimental model approximately can assess radiation dose of patient in standard X-ray examination and can apply to CR examination, digital radiography and even film-cassette system.

Clinical Correlation between the Autoimmune Thyroid Disease for the Thyroid Autoimmune Antibodies and the Maximum Standardized Uptake Value: Base on the Hashimoto's Thyroiditis and the Graves' Disease (자가 면역 갑상선 질환에 대한 최대 표준섭취계수와 갑상선 자가 항체의 임상적 상관관계: 하시모토 갑상선염과 그레이브스병 중심으로)

  • Woo, Minsun;Baek, Chulin;Yoo, Jueun;Song, Jongwoo;Im, Inchul;Son, Juchul;Cho, Soodong;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.241-248
    • /
    • 2014
  • The purpose of this study were to analyze the clinical correlation between the thyroid autoimmune antibodies (anti-TPO Ab, anti-TG Ab, and TSH) and the maximum standardized uptake value ($SUV_{max}$) base on the Hashimoto's thyroiditis and the Graves' disease in diffusely $^{18}F-FDG$ uptake of the thyroid gland to the PET/CT image. To achieve this, we was performed the PET/CT examination for the 1,097 subjects from May 2010 to April 2013 in the health screening, and was detected the diffused FDG thyroid uptake, and was additionally performed the thyroid function test (TFT) and the ultrasound (US). As a results, the autoimmune thyroid disease with the diffused FDG thyroid uptake were discovered 39 patients (3.9%), of this, the Hashimoto's thyroiditis was 43.6% and the Graves' disease was 23.1%. Hashimoto's thyroiditis was shown the positive reaction of high titer between the anti-TPO Ab and the anti-TG Ab level, and the correlation coefficient between the $SUV_{max}$ and the anti-TPO Ab was a statistically significant (r>04, p<0.05). Also, Graves' disease was shown the positive reaction of high titer most of the thyroid autoimmune antibodies, and the correlation coefficient between the $SUV_{max}$ and the anti-TPO Ab was a statistically significant (r>05, p<0.01). Therefor, when have a high standard of the $SUV_{max}$ due to the diffusely $^{18}F-FDG$ uptake of the thyroid gland, Hashimoto's thyroiditis and Graves' disease were proportionally increased the anti-TPO Ab and TSH level, respectively. The correlation coefficient between the $SUV_{max}$ and the thyroid autoimmune antibodies will be the most influential criterion that was a standard of judgment for the epihpenomenon of the autoimmune thyroid disease, and it will be available for the clinical application.

Correlation between the Seoul Neuropsychological Screening Battery of the Parkinson's Disease Patient with Mild Cognitive Impairment and Change of the Cerebral Ventricle Volume in the Brain MRI (경도인지장애를 동반한 파킨슨병 환자의 서울신경심리검사와 뇌 자기공명영상에서 뇌실 체적 변화에 대한 상관관계)

  • Lee, Hyunyong;Kim, Hyeonjin;Im, Inchul;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.231-240
    • /
    • 2014
  • The purpose of this study were to analyze that the Seoul neuropsychological screening battery (SNSB) for the evaluating cognitive assessment of the Parkinson's disease patients with mild cognitive impairment (PD-MCI) and the changes of the cerebral ventricle volume in the brain magnetic resonance imaging (MRI), and we has been bring forward the guideline to determine the diagnostic criteria for the PD-MCI. To achieve this, we was diagnosed with Parkinson's disease patients (PD-MCI group: 34 patients; Parkinson's disease with normal cognition, PD-NC group: 34 patients) to perform the SNSB test for the attention, language, memory, visuospatial, and frontal/executive functions and the brain MRI. Additionally, to compared the change of the cerebral ventricle volume, we performed the brain MRI for the 32 normal control (NC) group. The volumetric analysis for a specific cerebral ventricle performed by using Freesurfer Ver. 5.1 (Massachusetts general Hospital, Boston MA, USA). As a results, compared to the PD-NC group, the PD-MCI group were statistically significant reduction in the ability to perform the memory and the visuospatial function (p<0.05). The volumetric changes for a specific cerebral ventricle were statistically significant variation in the left and right lateral ventricle, left and right inferior lateral ventricle, and 3rd ventricle. Although, in order to compared the objectification, the normalized percentage applied to the volumetric changes showed to extend the PD-MCI group than the PD-NC group. Specially, the left and right ventricle extension for the PD-MCI patients conspicuously had showed a quantitative linear relationship between the memory and the visuospatial function for the SNSB (r>0.5, p<0.05). Therefore, we were able to judge the diagnostic criteria of the PD-MCI through that can observe the volumetric variation of the specific cerebral ventricle by using Freesurfer in brain MRI, and to analyze the correlation between the SNSB.

Monitoring on Dose Index Analyzed in the Mammography (유방촬영검사에서 선량지표분석에 대한 모니터링)

  • Cho, Ji-Hwan;Lee, Hyo-Yeong;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.477-482
    • /
    • 2016
  • This study is tried to determine whether the management of medical radiation is well handled by comparison the guidelines of KFDA(korea food & drug administration) with analysis of dose indicator in mammography. As a method, it is analysed that kVp, exposure time, mAs, compressed breast thickness, average glandular dose and body mass index that were classified in the examination of both breasts by CC(cranio-caudal) and MLO(medio-lateral oblique) with EMR(electronic medical record) and dose report that were sent to the PACS(picture archiving communication system). As a result, in the site inspection according to the age, Compressed breast thickness in CC and MLO were the thickest of 45.6 mm and 49.6 mm in the 50-59 year old respectively. In the overall average compressed breast thickness, CC were 44.2 mm and MLO were 48.9 mm. MLO has more thick by 4.7 mm. In average glandular dose, CC were 1.05 mGy and MLO were 1.14 mGy. MLO has higher by 0.09 mGy than CC. As the compressed breast thickness increases 10mm, CC and MLO increases 0.15 mGy and 0.17 mGy respectively. When it was compared with the average glandular dose of 1.16 mGy per 1 film presented by KFDA, CC was showed 1.05 mGy. However, the 60 mm or more was found to exceed a 1.30 mGy. Also, As the compressed breast thickness was higher, body mass index showed high score. And in the case of 25 or more in the obese body index according to body mass index, it was showed obesity in case of the compressed breast thickness was more than 50mm.

The vacuolar processing enzyme (VPE) mutation suppresses an HR-like cell death induced by the double knockout mutant of vacuolar Ca2+-ATPases in Arabidopsis (애기장대에서 두 액포막 칼슘펌프 돌연변이에 의하여 유도되는 세포사멸 표현형의 액포수식효소(VPE) 돌연변이에 의한 억제)

  • Park, Hyeong-Cheol;Lee, Sang-Min;Kim, Ho-Soo;Chung, Woo-Sik
    • Journal of Plant Biotechnology
    • /
    • v.38 no.2
    • /
    • pp.169-175
    • /
    • 2011
  • Calcium ($Ca^{2+}$) signals have been implicated in regulating plant development and responses to the environmental stresses including a programmed cell death pathway. In animals and plants, cytosolic $Ca^{2+}$ signals have been involved in the activation of programmed cell death (PCD). Recently, we reported that disruption of Arabidopsis vacuolar $\b{A}$utoinhibited $\underline{C}a^{2+}$-$\b{A}$TPases (ACAs), ACA4 and ACA11, resulted in the activation of a salicylic acid-dependent programmed cell death pathway. Although extensive studies have revealed various components of a PCD in plants, executors to directly induce PCD are well unknown. Here, we provide that the vacuolar processing enzymes (VPEs) are involved in a PCD induced by the double knockout mutant of vacuolar $Ca^{2+}$-ATPases in Arabidopsis. The gene expression of VPE was rapidly up-regulated and the enzyme activity of VPE was increased in the double mutant plants. We also generated aca4/aca11/avpe, aca4/aca11/${\gamma}$vpe and aca4/aca11/avpe/${\gamma}$vpe mutant plants. Although cell death phenotype of the double mutant plants was not completely disappeared in the triple and quadruple mutant plants, the triple and quadruple mutant plants showed to significantly delay cell death phenotype of the double mutant plants. These results suggest that the VPE is involved in the HR-like cell death in the double mutant of vacuolar $Ca^{2+}$-ATPases in Arabidopsis.