Abstract
This study suggested evaluation of approximately exposure to low-dose ionization radiation from medical images using a computed radiography (CR) system in standard X-ray examination and experimental model can compare diagnostic reference level (DRL) will suggest on optimization condition of guard about medical radiation of low dose space. Entrance surface dose (ESD) cross-measuring by standard dosimeter and optically stimulated luminescence dosimeters (OSLDs) in experiment condition about tube voltage and current of X-ray generator. Also, Hounsfield unit (HU) scale measured about each experiment condition in CR system and after character relationship table and graph tabulate about ESD and HU scale, approximately radiation dose about head, neck, thoracic, abdomen, and pelvis draw a measurement. In result measuring head, neck, thoracic, abdomen, and pelvis, average of ESD is 2.10, 2.01, 1.13, 2.97, and 1.95 mGy, respectively. HU scale is $3,276{\pm}3.72$, $3,217{\pm}2.93$, $2,768{\pm}3.13$, $3,782{\pm}5.19$, and $2,318{\pm}4.64$, respectively, in CR image. At this moment, using characteristic relationship table and graph, ESD measured approximately 2.16, 2.06, 1.19, 3.05, and 2.07 mGy, respectively. Average error of measuring value and ESD measured approximately smaller than 3%, this have credibility cover all the bases radiology area of measurement 5%. In its final analysis, this study suggest new experimental model approximately can assess radiation dose of patient in standard X-ray examination and can apply to CR examination, digital radiography and even film-cassette system.
Keywords
computed radiography (CR); diagnostic reference level (DRL); Hounsfield unit (HU) scale; entrance surface dose (ESD);
Citations & Related Records
연도 인용수 순위
  • Reference
1 W. De Vos, J. Casselman, G. R. Swennen, "Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: a systematic review of the literature.", Int. J. Oral. Maxillofac. Surg., Vol. 38, pp.609-625, 2009.   DOI   ScienceOn
2 H. Precht, O. Gerke, K. Rosendahl, A. Tingberg, D. Waaler, "Digital radiography: optimization of image quality and dose using multi-frequency software.", Pediatr. Radiol., Vol. 42, pp.1112-1118, 2012.   DOI   ScienceOn
3 T. Sasagawa, J. Kunogi, S. Masuyama, S. Ogihara, Y. Takeuchi, Y. Takeshita, N. Kamiya, H. Murakami, H. Tsuchiya, "New computed radiography processing condition for whole-spine radiography.", Orthopedics., Vol. 34, pp.906-910, 2011.
4 UNSCEAR, "Sources and Effects of Ionizing Radiation, Annex D: Medical Radiation Exposure", United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) 2000 Report Vol. I, New York, United Nations, 2000.
5 KFDA, "Radiation Health Newsletter", Korea Food and Drug Administration (KFDA), Vol.17, PP.1-12, 2010.
6 ICRP, "Low-dose Extrapolation of Radiation-related Cancer Risk", International Commission on Radiological Protection (ICRP) Publication 99, 2005.
7 ICRP, "The 2007 Recommendations of the International Commission on Radiological Protection.", ICRP Publication 103, 2007.
8 IAEA, "Absorbed Dose Determination in External Beam Radiotherapy. An International Code of Practice for dosimetry Based on Standards of Absorbed Dose to Water.", International Atomic Energy Agency (IAEA) report series No. 398, Vienna, MD, 2001.
9 ICRP, "Basic Anatomical and Physiological Data for Use in Radiological Protection: Reference Values.", International Commission on Radiological Protection (ICRP) Publication 89, 2002.