• Title/Summary/Keyword: 기둥길이

Search Result 182, Processing Time 0.028 seconds

Strength Prediction Model of Interior Flat-Plate Column Connections according to Design Parameters (설계변수에 따른 플랫플레이트-기둥 접합부의 강도산정모형)

  • Lee, Do-Bum;Park, Hong-Gun;Lee, Li-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.3 s.93
    • /
    • pp.405-414
    • /
    • 2006
  • In the present study, a numerical analysis was performed for interior connections of continuous flat plate to analyze the effect of design parameters such as column section shape, gravity load and slab span on the behavioral characteristics of the connections. For the purpose, a computer program for nonlinear FE analysis was developed, and the validity was verified. Through the parametric study, the variations of shear stress distribution around the connection were investigated. According to the result of numerical analysis, as the length of the cross section of column in the direction of lateral load increases and gravity load increases, the effective area and the maximum shear strength providing the torsional resistance decrease considerably. And as the slab span loaded with relatively large gravity load increases, the negative moment around the connection increases and therefore the strength of connection against unbalanced moment decreases. By considering the effect of design parameters on the strength of the connections, the effective shear strength to calculate the torsional moment capacity of connection was proposed and the effectiveness of the proposed shear strength was verified.

Length of Plastic Hinge in RC Columns under Cyclic Loading (반복 하중을 받는 철근콘크리트 기둥의 소성힌지 길이)

  • Park, Jong-Wook;Choi, Im-Jun;Moon, Cho-Hwa;Lee, Jung-Yoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.11-12
    • /
    • 2009
  • The small height to depth ratio column dominated by shear after tension steel yielded and the energy dissipation capacity reduce remarkably due to the affection of axial force. This procedure incur in the plastic hinge region and not in all of the region at the same time but from somewhere where the energy was concentrated. This study was reported about the variation of length of the plastic hinge under cyclic loading of the RC columns through the test.

  • PDF

Dimensional Characteristics and Species Identification of Posts in the 19th century Houses in Cheongdo, Korea (경북 청도 지역 19세기 고택의 기둥의 크기와 수종 식별)

  • Eom, Young Geun;Oh, Sei Chang;Xu, Guang Zhu;Kim, Sam Sung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.177-183
    • /
    • 2009
  • Characteristics analysis and species identification of post were carried out in four old traditional wooden frame houses in Cheongdo-gun. The diameter and height of post, and distance between posts are related with each other. It was considered that the traditional wooden frame houses were constructed according to the diameter and height of post as a basic dimension in distance between posts. Of the wood member samples obtained in the site, softwoods in three old houses and hardwoods in one old house were separated through light microscopy. The hardwoods were found to be Castanea crenata. and softwoods were all identified as Pinus densiflora.

A Study of Teaching Materials for the Professional Development of Elementary School Teachers: The Number of Development Figures of the Triangular Prism and the Quadrangular Prism (초등교사의 전문성 신장을 위한 교재 연구: 삼각기둥과 사각기둥의 전개도의 수)

  • Park, Kyo Sik
    • Journal of Elementary Mathematics Education in Korea
    • /
    • v.20 no.3
    • /
    • pp.393-406
    • /
    • 2016
  • In the sixth grade mathematics, drawing of development figures of the triangular prism and the quadrangular prism is recommended in terms of the creativity. In this sense, the teacher has the need to check in advance all the possible development figures of the triangular prism and the quadrangular prism before teaching on them. However, previous studies that currently give all the possible development figures of the triangular prism and the quadrangular prism are hard to find. For this reason, in this paper, as a study of teaching materials for the professional development of elementary school teachers, the method of finding all the possible development figures of the triangular prism and all the possible development figures of the quadrangular prism without omissions and overlaps and the number of each of development figures which can be obtained by that method are discussed. Here lengths of the three sides of base planes of the triangular prism are different each other and lengths of the four sides of base planes of the quadrangular prism are different each other. This discussion is needed in terms of a study of teaching materials in order to prepare for predictable questions to ask the number of the possible development figures of the triangular prism and the number of the possible development figures of the quadrangular prism in classes. In addition, through this discussion, this paper presents the development figures of the triangular prism and the development figures of the quadrangular prism without omissions and overlaps. And teachers can take advantage of them for determining the correctness of the development figures drew by students and guiding students to draw the development figures creatively in actual classes.

A Study on Elastic Buckling Strength of Truss-Stayed Single Column System (트러스로 보강된 단일기둥시스템의 탄성좌굴강도에 대한 연구)

  • Kim, Kyung-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5984-5989
    • /
    • 2011
  • The buckling strength of a pin-ended column may be increased significantly by reinforcing it with an assemblage of cross-arm members rigidly connected to the modpoint of the column and stayed members connecting the ends of the columns and cross-arm members. The purpose of the stays and cross-arm members is to introduce restraint against translation and rotation and thereby decrease the effective buckling length of the column. In this study, buckling strengths of the reinforced columns were quantitatively evaluated from analytical solutions and elastic/inelastic finite elements analysis and the results were compared each other. It was found that the reinforcing system may increase the buckling strength up to 8 times compared to ones without reinforcing system.

Static and Dynamic Stability Analyses of Simple Tapered Columns with Constant Volume (일정체적 단순지지 변단면 기둥의 정·동적 안정해석)

  • Lee, Byoung Koo;Kim, Suk Ki
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3A
    • /
    • pp.533-538
    • /
    • 2006
  • This study deals with the static and dynamic stability analyses of simple tapered columns with constant volume. The crosssections of column taper are the regular polygons whose depths are varied with the parabolic functional fashion. The hingedhinged end constraint is chosen as the boundary condition of the column. The non-dimensional ordinary differential equation governing free vibrations of such column subjected to an axial load is derived and solved numerically. From numerical results, the relationships between natural frequencies and section ratios are obtained, from which the configurations of dynamic optimal shapes of columns and the strongest columns are extracted.

Plastic Hinge Length of Reinforced Concrete Columns with Low Height-to-Width Ratio (전단경간비가 작은 철근콘크리트 기둥의 소성힌지 길이)

  • Park, Jong-Wook;Woo, Jae-Hyun;Kim, Byung-Il;Lee, Jung-Yoon
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.5
    • /
    • pp.675-684
    • /
    • 2010
  • The reinforced concrete members are designed to fail in flexural to lead ductile fracture. In the building structures, the failure is typically imposed on beams to prevent damages in columns. However, progression of plastic collapse mechanism may ultimately develop, a plastic hinge at the bottem end of the first floor column, which then can be subjected to shear or bond finally due to large axial force and small shear span-to-depth ratio. In this study, 10 RC column specimens failed in shear after flexural yielding was investigated to determine the factors affecting the plastic hinge length. The findings of this study showed that the most effective factor affecting the plastic hinge length was an axial force. As an axial force increase, an axial strain and a ductility ratio were decreased obviously. The test also shows the observed plastic hinge length was about 0.8~1.2d and the this result has difference compared with forward research.

Nonlinear Lateral Behavior and Cross-Sectional Stress Distribution of Concrete Rocking Columns (콘크리트 회전형 기둥의 비선형 횡방향 거동 및 단면응력 분포 분석)

  • Roh, Hwa-Sung;Hwang, Woong-Ik;Lee, Hu-Seok;Lee, Jong-Seh
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.285-292
    • /
    • 2012
  • Fixed connection is generally used for beam and column connections of concrete structures, but significant damages at the connection due to severe earthquakes have been reported. In order to reduce damages of the connection and improve seismic performance of the connection, several innovative connections have been suggested. One newly proposed connection type allows a rotation of the connection for applications in rotating or rocking beams, columns, and shear walls. Such structural elements would provide a nonlinear lateral force-displacement response since their contact depth developed during rotation is gradually reduced and the stress across the sections of the elements is non-linearly distributed around a contact area, which is called an elastic hinge region in the present study. The purpose of the present study is to define the elastic hinge region or length for the rocking columns, through investigating the cross-sectional stress distribution during their lateral behavior. Performing a finite element analysis (FEA), several parameters are considered including axial load levels (5% and 10% of nominal strength), different boundary conditions (confined-ends and cantilever types), and slenderness ratios (length/depth = 5, 7, 10). The FEA results showed that the elastic hinge length does not directly depend on the parameters considered, but it is governed by a contact depth only. The elastic hinge length started to develop after an opening state and increased non-linearly until a rocking point(pre-rocking). However, the length did not increase any more after the rocking point (post-rocking) and remained as a constant value. Half space model predicting the elastic hinge length is adapted and the results are compared with the numerical results.

An Experimental Research on the Shear Friction Behavior of Beam-Column Joints of Partial Precast Concrete Structures (부분PC 보-기둥 접합부의 전단 마찰 거동에 관한 실험 연구)

  • Kim, Sang-Yeon
    • Land and Housing Review
    • /
    • v.5 no.2
    • /
    • pp.91-97
    • /
    • 2014
  • An experimental program was initiated to investigate the structural capacity of PC (Precast Concrete) beam-column joints used for the underground parking structure. Static testing of 4 typical PC beam-column joints specimens was conducted. Specimens were designed to span a range of parameters typically encountered for such members, based on findings from the survey of existing PC joint details used in the construction fields in Korea. The specimens were four by their joint types and testing parameters. The specific structural behavior germane to each specimen, and general observations on overall member behavior as a function of the considered parameters, are reported. From the results of tests on four PC joints specimens, the beam-column joints of PC structure used for the underground parking building was found to have similar structural capacities when comparing to the cast-in-place concrete system.

Strength Experimental Study on Precast Column-R.C. Foundation Anchor Joint Subjected to Cyclic Horizontal Loading (반복-수평력을 받는 프리캐스트기둥- RC기초 Anchor 접합부의 내력 실험 연구)

  • Lee, Ho;Jung, Hwoan-Mok;Cha, Byung-Gi;Byun, Sang-Min
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.2
    • /
    • pp.45-52
    • /
    • 2009
  • This paper experimentally evaluates the strength characteristics of precast column-R.C. foundation anchor joint subjected to the cyclic horizontal load. The study presents differences in accurate stress transfer path and destruction mechanism between the concrete structural body applying the precast column-R.C. foundation anchor joint and the concrete structural body applying the steel joint. the result from width load experiment on reinforcing steel under the cyclic horizontal load provides the necessary minimum insertion length to construct the precast column-R.C. foundation anchor joint. This study also presents the accurate stress transfer path and destruction mechanism on the anchor joint th meet the customer's requirements, comparing stress transfer path and destruction mechanism provided by the experiment and those provided by the product manual. Eventually, this study presents all the necessary fundamental data to provide the construction design with accurate number of reinforcing steel, diameter of the steel, fixation length of the steel, etc. to build the optimum precast concrete column.

  • PDF