• Title/Summary/Keyword: 근접효과

Search Result 708, Processing Time 0.028 seconds

Analysis of Changes in Ion Concentration with Time and Drainage Ratio under EC-based Nutrient Control in Closed-loop Soilless Culture for Sweet Pepper Plants (Capsicum annum L. 'Boogie') (EC 기준 순환식 파프리카 수경재배에서 시간 경과 및 배액율에 따른 이온농도 변화 분석)

  • Ahn, Tae-In;Shin, Jong-Wha;Son, Jung-Eek
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.298-304
    • /
    • 2010
  • Nutrient uptake by plants and drainage ratio in culture beds can affect ion balance and concentrations of nutrient solutions in electrical conductivity (EC)-based closed-loop soilless culture. This study was conducted to analyze ion concentration changes with time and drainage ratio under EC-based nutrient control in closed-loop soilless culture for sweet pepper plants (Capsicum annum L. 'Boogie'). At first experiment, ion concentrations of the nutrient solution were periodically analysed while collected drainage was being reused by mixing with fresh nutrient solution at a dilution rate of EC $2.2\;dSm^{-1}$. Changes in ion concentrations of $K^+$, $Ca^{2+}$, $Mg^{2+}$, $NO_3^-$, $SO_4^{2-}$, and $PO_4^{3-}$ were 1.13, 5.35, 0.92, 0.9, 1.10, $0.19\;meq{\cdot}L^{-1}$, respectively. Ion balance such as $K^+$ : $Ca^{2+}$ and $SO_4^{2-}$ : $NO_3^-$ were mainly affected during the recirculation of nutrient solution. At second experiment, ion concentrations and EC of drainage were compared before and after replenishment under different four drainage ratios of 7%, 16%, 39%, and 51%. Ion ratios of the recirculated nutrient solutions such as $K^+$ : $Ca^{2+}$ for cation and $SO_4^{2-}$ : $NO_3^-$ for anion were investigated. ECs of drainage decreased with increase of drainage ratio and each ion concentration showed the same trends as EC did. Ion balances in drainage with drainage ratio were a little different from each other, but each ratio could be corrected by replenishment process. The ion balance at 7% drainage ratio was closest to initial ratio and followed by 16%, 51%, and 39% in the order. Ion balance such as $K^+$ : $Ca^{2+}$ and $NO_3^-$ : $PO_4^{3-}$ were mainly affected the correction process.

P300 speller using a new stimulus presentation paradigm (새로운 자극제시방법을 사용한 P300 문자입력기)

  • Eom, Jin-Sup;Yang, Hye-Ryeon;Park, Mi-Sook;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.16 no.1
    • /
    • pp.107-116
    • /
    • 2013
  • In the implementation of a P300 speller, rows and columns paradigm (RCP) is most commonly used. However, the RCP remains subject to adjacency-distraction error and double-flash problems. This study suggests a novel P300 speller stimuli presentation-the sub-block paradigm (SBP) that is likely to solve the problems effectively. Fifteen subjects participated in this experiment where both SBP and RCP were used to implement the P300 speller. Electroencephalography (EEG) activity was recorded from Fz, Cz, Pz, Oz, P3, P4, PO7, and PO8. Each paradigm consisted of a training phase to train a classifier and a testing phase to evaluate the speller. Eighteen characters were used for the target stimuli in the training phase. Additionally, 5 subjects were required to spell 50 characters and the rest of the subjects were to spell 25 characters in the testing phase. Classification accuracy results show that average accuracy was significantly higher in SBP as of 83.73% than that of RCP as of 66.40%. Grand mean event-related potentials (ERPs) at Pz show that positive peak amplitude for the target stimuli was greater in SBP compared to that of RCP. It was found that subjects tended to attend more to the characters in SBP. According to the participants' ratings on how comfortable they were with using each type of paradigm on 7-point Likert scale, most subjects responded 'very difficult' in RCP while responding 'medium' and 'easy' in SBP. The result showed that SBP was felt more comfortable than RCP by the subjects. In sum, the SBP was more correct in P300 speller performance as well as more convenient for users than the RCP. The actual limitations in the study were discussed in the last part of this paper.

  • PDF

The Evaluation of Quantitative Accuracy According to Detection Distance in SPECT/CT Applied to Collimator Detector Response(CDR) Recovery (Collimator Detector Response(CDR) 회복이 적용된 SPECT/CT에서 검출거리에 따른 정량적 정확성 평가)

  • Kim, Ji-Hyeon;Son, Hyeon-Soo;Lee, Juyoung;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.55-64
    • /
    • 2017
  • Purpose Recently, with the spread of SPECT/CT, various image correction methods can be applied quickly and accurately, which enabled us to expect quantitative accuracy as well as image quality improvement. Among them, the Collimator Detector Response(CDR) recovery is a correction method aiming at resolution recovery by compensating the blurring effect generated from the distance between the detector and the object. The purpose of this study is to find out quantitative change depending on the change in detection distance in SPECT/CT images with CDR recovery applied. Materials and Methods In order to find out the error of acquisition count depending on the change of detection distance, we set the detection distance according to the obit type as X, Y axis radius 30cm for circular, X, Y axis radius 21cm, 10cm for non-circular and non-circular auto(=auto body contouring, ABC_spacing limit 1cm) and applied reconstruction methods by dividing them into Astonish(3D-OSEM with CDR recovery) and OSEM(w/o CDR recovery) to find out the difference in activity recovery depending on the use of CDR recovery. At this time, attenuation correction, scatter correction, and decay correction were applied to all images. For the quantitative evaluation, calibration scan(cylindrical phantom, $^{99m}TcO_4$ 123.3 MBq, water 9293 ml) was obtained for the purpose of calculating the calibration factor(CF). For the phantom scan, a 50 cc syringe was filled with 31 ml of water and a phantom image was obtained by setting $^{99m}TcO_4$ 123.3 MBq. We set the VOI(volume of interest) in the entire volume of the syringe in the phantom image to measure total counts for each condition and obtained the error of the measured value against true value set by setting CF to check the quantitative accuracy according to the correction. Results The calculated CF was 154.28 (Bq/ml/cps/ml) and the measured values against true values in each conditional image were analyzed to be circular 87.5%, non-circular 90.1%, ABC 91.3% and circular 93.6%, non-circular 93.6%, ABC 93.9% in OSEM and Astonish, respectively. The closer the detection distance, the higher the accuracy of OSEM, and Astonish showed almost similar values regardless of distance. The error was the largest in the OSEM circular(-13.5%) and the smallest in the Astonish ABC(-6.1%). Conclusion SPECT/CT images showed that when the distance compensation is made through the application of CDR recovery, the detection distance shows almost the same quantitative accuracy as the proximity detection even under the distant condition, and accurate correction is possible without being affected by the change in detection distance.

  • PDF

Evaluation of Incident Detection Algorithms focused on APID, DES, DELOS and McMaster (돌발상황 검지알고리즘의 실증적 평가 (APID, DES, DELOS, McMaster를 중심으로))

  • Nam, Doo-Hee;Baek, Seung-Kirl;Kim, Sang-Gu
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.7 s.78
    • /
    • pp.119-129
    • /
    • 2004
  • This paper is designed to report the results of development and validation procedures in relation to the Freeway Incident Management System (FIMS) prototype development as part of Intelligent Transportation Systems Research and Development program. The central core of the FIMS is an integration of the component parts and the modular, but the integrated system for freeway management. The whole approach has been component-orientated, with a secondary emphasis being placed on the traffic characteristics at the sites. The first action taken during the development process was the selection of the required data for each components within the existing infrastructure of Korean freeway system. After through review and analysis of vehicle detection data, the pilot site led to the utilization of different technologies in relation to the specific needs and character of the implementation. This meant that the existing system was tested in a different configuration at different sections of freeway, thereby increasing the validity and scope of the overall findings. The incident detection module has been performed according to predefined system validation specifications. The system validation specifications have identified two component data collection and analysis patterns which were outlined in the validation specifications; the on-line and off-line testing procedural frameworks. The off-line testing was achieved using asynchronous analysis, commonly in conjunction with simulation of device input data to take full advantage of the opportunity to test and calibrate the incident detection algorithms focused on APID, DES, DELOS and McMaster. The simulation was done with the use of synchronous analysis, thereby providing a means for testing the incident detection module.

A Study on the Forecasting Model on Market Share of a Retail Facility -Focusing on Extension of Interaction Model- (유통시설의 시장점유율 예측 모델에 관한 연구 -상호작용 모델의 확장을 중심으로)

  • 최민성
    • Journal of Distribution Research
    • /
    • v.5 no.2
    • /
    • pp.49-68
    • /
    • 2001
  • In this chapter, we summarize the results on the optimal location selection and present limitation and direction of research. In order to reach the objective, this study selected and tested the interaction model which obtains the value of co-ordinates on location selection through the optimization technique. This study used the original variables in the model, but the results indicated that there is difference in reality. In order to overcome this difference, this study peformed market survey and found the new variables (first data such as price, quality and assortment of goods, and the second data such as aggregate area, and area of shop, and the number of cars in the parking lot). Then this study determined an optimal variable by empirical analysis which compares an actual value of market share in 1988 with the market share yielded in the model. However, this study found the market share in each variables does not reflect a reality due to an assumption of λ-value in the model. In order to improve this, this study performed a sensitivity analysis which adds the λ value from 1.0 to 2.9 marginally. The analyzed result indicated the highest significance with the market share ratio in 1998 at λ of 1.0. Applying the weighted value to a variable from each of the first data and second data yielded the results that more variables from the first data coincided with the realistic rank on sales. Although this study have some limits and improvements, if a marketer uses this extended model, more significant results will be produced.

  • PDF

Oxidative Degradation of PCE/TCE Using $KMnO_4$ in Aqueous Solutions under Steady Flow Conditions (유동조건에서 $KMnO_4$도입에 따른 수용액중 PCE/TCE의 산화분해)

  • Kim, Heon-Ki;Kim, Tae-Yun
    • Economic and Environmental Geology
    • /
    • v.41 no.6
    • /
    • pp.685-693
    • /
    • 2008
  • The rates of oxidative degradation of perchloroethene (PCE) and trichloroethene (TCE) using $KMnO_4$ solution were evaluated under the flow condition using a bench-scale transport experimental setup. Parameters which are considered to affect the reaction rates tested in this study were the contact time (or retention time), and the concentration of oxidizing agent. A glass column packed with coarse sand was used for simulating the aquifer condition. Contact time between reactants was controlled by changing the flow rate of the solution through the column. The inflow concentrations of PCE and TCE were controlled constant within the range of $0.11{\sim}0.21\;mM$ and $1.3{\sim}1.5\;mM$, respectively. And the contact time was $14{\sim}125$ min for PCE and $15{\sim}36$ min for TCE. The $KMnO_4$ concentration was controlled constant during experiment in the range of $0.6{\sim}2.5\;mM$. It was found that the reduction of PCE and TCE concentrations were inversely proportional to the contact time. The exact reaction order for the PCE and TCE degradation reaction could not be determined under the experimental condition used in this study. However, the estimated reaction rate constants assuming pseudo-1st order reaction agree with those reported based on batch studies. TCE degradation rate was proportional to $KMnO_4$ concentration. This was considered to be the result of using high inflow concentrations of reactant, which might be the case at the vicinity of the source zones in aquifer. The results of this study, performed using a dynamic flow system, are expected to provide useful information for designing and implementing a field scale oxidative removal process for PCE/TCE-contaminated sites.

Accelerated Hyperfractionated Radiotherapy for Locally Advanced Uterine Cervix Cancers (국소진행된 자궁경부암에서의 가속과분할 방사선치료)

  • Seo, Young-Seok;Cho, Chul-Koo;Yoo, Seong-Yul;Kim, Mi-Sook;Yang, Kang-Mo;Yoo, Hyung-Jun;Choi, Chul-Won;Lee, Kyung-Hee;Lee, Eui-Don;Rhu, Sang-Young;Choi, Suck-Chul;Kim, Moon-Hong;Kim, Beob-Jong
    • Radiation Oncology Journal
    • /
    • v.26 no.1
    • /
    • pp.24-34
    • /
    • 2008
  • Purpose: To assess the efficacy of the use of accelerated hyperfractionated radiotherapy(AHRT) for locally advanced uterine cervix cancers. Materials and Methods: Between May 2000 and September 2002, 179 patients were identified with FIGO stage IIB, IIIB, and IVA cancers. Of the 179 patients, 45 patients were treated with AHRT(AHRT group) and 134 patients were treated with conventional radiotherapy(CRT group), respectively. Patients undergoing the AHRT regimen received a dose of 30 Gy in 20 fractions(1.5 $Gy{\times}2$ fractions/day) to the whole pelvis. Subsequently, with a midline block, we administered a parametrial boost with a dose of 20 Gy using 2 Gy fractions. Patients also received two courses of low-dose-rate brachytherapy, up to a total dose of 85{\sim}90 Gy to point A. In the CRT group of patients, the total dose to point A was $85{\sim}90$ Gy. The overall treatment duration was a median of 37 and 66 days for patients that received AHRT and CRT, respectively. Statistical analysis was calculated by use of the Kaplan-Meier method, the log-rank test, and Chi-squared test. Results: For patients that received cisplatin-based concurrent chemotherapy and radiotherapy, the local control rate at 5 years was 100% and 79.2% for the AHRT and CRT group of patients, respectively(p=0.028). The 5-year survival rate for patients with a stage IIB bulky tumor was 82.6% and 62.1% for the AHRT group and CRT group, respectively(p=0.040). There was no statistically significant difference for severe late toxicity between the two groups(p=0.561). Conclusion: In this study, we observed that treatment with AHRT with concurrent chemotherapy allows a significant advantage of local control and survival for locally advanced uterine cervix cancers.

Applicability of Vegetation Index and SPAD Reading to Nondestructive Diagnosis of Rice Growth and Nitrogen Nutrition Status (식생지수와 SPAD를 이용한 벼 생육 및 질소영양상태의 비파괴적 진단 가능성 검토)

  • Kim Min-Ho;Shin Jin-Chul;Lee Byun-Woo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.6
    • /
    • pp.369-377
    • /
    • 2005
  • Precise application of topdressing nitrogen (N) fertilizer is indispensible for securing high yield and good quality of rice and minimizing N losses to the environment as well. For precise N management, growth and nitrogen nutrition status (NNS) should be diagnosed rapidly and accurately. The objective of the study was to evaluate the applicability of vegetation index (VI) calculated from hyperspectral canopy reflectance measurement and SPAD reading to nondestructive in situ diagnosis of growth and NNS of rice. Canopy reflectance, SPAD read­ing, growth parameters, and NNS characteristics were measured from various N treatments to evaluate the relationships among them for two cropping seasons from 2001 to 2002. The correlation coefficient of VIs with variables of growth and NNS increased positively as rice canopy became more closed. Regardless of growth stages, VIs had significantly high correlations with LAI, shoot dry weight (DW), shoot N content and nitrogen nutrition index (NNI). Those correlation coefficients increased steadily before heading stage as rice grew up. However, tiller number and leaf N concentration showed significantly high correlations with VIs only at and after panicle initiation stage (PIS). Among the VIs, RVIgreen had significantly higher correlation with the measured parameters than the other VIs: it showed correlation coefficients greater than 0.8 with leaf and shoot N concentration and DW, and much higher coefficients greater than 0.9 with LAI, shoot N content, and NNI. At LAI of below 2.5, VIs had non-significant or low correlations with the growth and NNS indicators due to the background effects. SPAD reading had significantly high correlation with leaf N concentration and NNI at each growth stage. In addition, it had significant correlations with variables of growth and NNS at PIS and booting stage, particularly, at booting stage. Though SPAD reading had a significantly high correlation value at a given growth stage in each year, it showed very weak relationship with variables of growth and NNS when pooled across growth stages and years. In conclusion, RVIgreen was found to be the most reliable VI to estimate the growth and NNS of rice around at PIS, but SPAD reading had much limitations.

Effects of Compost Leachate on Growth and Yield of Leaf Lettuce in Hydroponic Culture (퇴비단 여과액비가 수경재배에서 상추의 생육과 수량에 미치는 영향)

  • Ryoo, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.15 no.1
    • /
    • pp.51-58
    • /
    • 2009
  • The compost leachate was dark-colored solution that leaches out of the bottom of the compost pile. The compost leachate was rich in nutrients and can potentially used in plant culture. In the organic production, commercial liquid fertilizer was used to insure the availability of nutrients during the formation of the yield. The cost of supplemental liquid fertilizer could be reduced by developing a fertilizer based on animal fertilizer. This experiment was conducted to investigate the effect of different combination of compost leachate and conventional inorganic solution in hydroponic culture for lettuce growth. Six different treatments were applied. The compost leachate(CL) and nutrient solution(NS) were mixed by six different mixing ratios of 0:100, 20:80, 40:60, 60:40%, 80:20 and 100%:0% based on nitrogen content. The chemical nutrient solution was the solution of National Horticulture Research Station for the growth of leaf lettuce. The concentration of nutrient solution was adjusted 1.5 mS/cm in EC. The compost leachate was low in phosphorus(P), calcium(Ca), magnesium(Mg), but rich in potassium(K). The plant height of lettuce treated with CL 20+NS 80% was similar with 100% NS of control plot. Plant height was highest in the plot of CL 20+NS 80%. The treatment of 100% compost leachate was lowest in the growth characteristics of leaf lettuce. Number of leaf was very low in 100% compost leachate compared with plot of chemical nutrient solution. In the beginning of growth stage, SPAD value was reduced in plot treated with CL100%, but CL20+NS80% plot was higher compared to 100% compost leachate. SPAD value of leaf lettuce leaves was decreased as the amount of CL was increased. The dry weight of lettuce were 107.4, 104.2g in plot of NS 100% and CL 20%+NS80%, respectively. The leaf number and plant weight were decreased at high application plots of compost leachate. The leaf lettuce showed lowest in the plot treated with 100% compost leachate, and the growth of lettuce severely decreased after application of 100% CL treatment. The results showed that compost leachate can be use as liquid fertilizer for the organic hydroponic production. The mixture solution of 20% of compost leachate and 80% of nutrient solution could be used as a nutrition solution in hydroponic culture of leaf lettuce. Our studies have shown that is possible to produce using compost leachate, although growth is slower than when using a conventional inorganic hydroponic solution.

  • PDF

The Influence of Botulinum Toxin Type A Masticatory Efficiency (보툴리눔 A형 독소가 저작효율에 미치는 영향)

  • Park, Hyung-Uk;Kwon, Jeong-Seung;Kim, Seong Taek;Choi, Jong-Hoon;Ahn, Hyung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.1
    • /
    • pp.53-67
    • /
    • 2013
  • This study was aimed to evaluate the masticatory efficiency after botulinum toxin type A (BTX-A) injection during 12 weeks using objective and subjective test. Also, we compared the difference of masticatory efficiency between group that injected into the masseter muscle only (M-group) and group that injected into the masseter and temporalis muscle (M-T group). The mixing ability index (MAI) was used as the objective indicator, and visual analogue scale (VAS) and food intake ability (FIA) index were used as the subjective indicators. It was concluded that masticatory efficiency was significantly lowered after a BTX-A injection into the masticatory muscle, but it gradually recovered in a predictable pattern by the 12 weeks. The disturbance of subjective masticatory efficiency was lasted longer than objective masticatory efficiency. The masticatory efficiency was lower in M-T group than M group. It was statistically significant in the VAS and FIA at 4 weeks, but the MAI showed no significancy. After 4weeks, there was rapid recovery of muscle function in M-T group, and the difference between two groups was not significant. It could be concluded that there will be no serious disturbance of mastication compared to injection is done only into the masseter muscle, even if injection is done into the masseter and temporalis muscle in dose of this study. According to the food properties, it was confirmed that people feel more discomfort on taking hard and tough foods after BTX-A injection and not only hard foods, but also intake of soft and runny foods were influenced by botulinum toxin injection.