• Title/Summary/Keyword: 구조보강

Search Result 2,829, Processing Time 0.029 seconds

A Study on the Optimum Modification of Dynamic Characteristics of Stiffened Plate Structure of Ship (선박의 보강판 구조물의 동특성의 최적 변경법에 관한 연구)

  • 박성현;박석주;고재용
    • Journal of the Korean Institute of Navigation
    • /
    • v.25 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • The purpose of this study is the optimum modification of dynamic characteristics of stiffened plate structure. In the method of the optimization, finite element method(FEM), sensitivity analysis and optimum structural modification method are used. To begin with, using FEM, the dynamic characteristics of stiffened plate structure is analyzed. Next, rate of change of dynamic characteristics by the change of design variable is calculated using the sensitivity analysis. Then, amount of change of design variable is calculated using this sensitivity value and optimum structural modification method. The change of natural frequency is made to be an objective function. Thickness of plate and cross section moment become a design variable. It is shown that the results are effective in the optimum modification for dynamic characteristics of the stiffened plate structure.

  • PDF

Integrated evaluation criteria for reinforcement priority of the water distribution systems (상수도 시스템의 보강 우선순위 선정을 위한 통합평가 기술)

  • Kim, Min Jun;Ko, Mun Jin;Kim, Ryul;Choi, Young Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.374-374
    • /
    • 2022
  • 상수도 시스템은 물을 수용가에 깨끗하고 충분하게 공급하는 사회기반시설 중 하나이다. 최근 상수도관로 노후화로 인하여 발생하는 누수, 적수, 단수 등의 피해를 방지하기 위하여 상수도관로 점검 및 진단을 수행하고 관 상태를 평가하여 해당 요소에 대한 보수 및 보강을 시행하고 있다. 하지만 기존의 정비사업은 관 노후도를 고려한 보강계획을 수립하여 효과적인 상수도 시스템 정비를 위하여 상수도관로에 영향을 미치는 수리 및 수질 평가를 통합적으로 고려한 보강 우선순위 결정이 필요하다. 따라서 본 연구에서는 상수도 시스템의 구조적, 비구조적 평가 인자를 동시에 고려한 시스템 보강 우선순위 선정을 위한 통합평가 기술을 제안하였다. 보강 우선순위 선정을 위하여 실제 상수도관로가 설치된 지역을 대상으로 상수도관로의 수리. 수질, 관 상태 등의 구조적 인자와 중요시설, 단수 시 피해인구 등의 비구조적 인자를 고려한 통합평가를 수행하였다. 구조적 인자 중 수리 및 수질 인자는 수리해석기법을 이용하여 기준치 통과 여부에 따라 평가하였으며 상수도관로의 관 상태는 관로의 제원, 매설 깊이, 노후도 등의 기준으로 평가하였다. 이러한 평가를 바탕으로 우선순위 선정을 위해 다기준의사결정법을 이용하여 상수도관로의 보강 우선순위를 선정하였다. 본 통합평가는 상수도관로의 구조적, 비구조적 위험도를 정량적으로 인지할 수 있을 뿐만 아니라 비구조적 인자를 고려하여 기존의 평가방법보다 더 신뢰할 수 있는 결과를 제공한다.

  • PDF

Finite Element Analyses on Ultimate Compressive Strength of Longitudinally Stiffened Polygonal Sections (종방향 보강재로 보강된 다각형 단면 기둥구조의 극한강도 해석)

  • Choi, Byung Ho;Park, Seong Mi;Hwang, Min Oh
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.40-40
    • /
    • 2011
  • 현재 일반적으로 활용되고 있는 원통형 쉘구조로 이루어진 타워구조의 대형화가 추진되면서 제작, 운반 편의성, 단면효율성, 경제성 제고를 위해 다각형단면 기둥구조물의 활용이 대두되고 있다. 하지만 다각형 단면 기둥구조의 극한강도에 대한 자료가 충분치 않고 관련 기준이나 지침이 명확히 제시되고 있지 않은 실정이다. 본 연구에서는 원통형 쉘구조물을 다각형구조물로 대체하여 제작될 경우 축방향 압축에 대한 내하력 향상 효과를 수치해석적으로 검토해 보고자 한다. 해석모델은 지름 2m, 두께 20mm인 원형강관 프로토타입 풍력타워 구조를 참고로 하여 이에 내접하도록 결정한 6~12각형 단면 형상으로써 높이 10,000mm인 3차원 기둥모델을 구현하였고 유한요소프로그램인 ABAQUS를 이용하여 해석하였다. 각 subpanel의 중앙에 종방향 보강재를 설치하였을 때 국부좌굴에 대한 내하력 변화를 비교하기 위해 종방향보강재로 보강한 모델을 구성하여 비교 해석을 수행하였다. 종방향 보강재의 제원은 미국 SSRC 제안식을 기준으로 삼았다. 탄성좌굴해석을 통해 탄성좌굴모드 형상을, 비선형비탄성해석을 통해 최종파괴모드 및 극한강도를 얻었다. 보강 전 후의 탄성좌굴 해석 결과로부터 최소모드의 고유치 값을 비교하였다. 각 subpanel 단면 중심부에 한 개의 보강재를 설치한 경우 탄성좌굴강도가 4배 가량 증가하였다. 이로부터, 보강재(n=1) 설치에 따라 유효 폭두께비가 1/2로 감소하는 효과를 확인 할 수 있다. 비선형해석결과로부터 subpanel의 단면중심에 보강재를 설치한 경우 보강재가 위치한 곳에 고정점이 형성되어 이를 중심으로 국부 좌굴모드에 변화가 생기는 것이 확인되었다. 이러한 변화는 다각형 단면 기둥구조의 내하력 성능, 즉 국부좌굴강도에 영향을 준다. 충분한 강성을 갖는 종방향 보강재가 설치된 경우, 극한상태에서도 유효폭두께비가 줄어드는 것과 같은 강도 향상 효과를 확인할 수 있다. 이러한 사실은 각 해석결과 극한강도를 DIN code, Migita와 Fukumoto의 제안식, SSRC 설계제안식 등과의 비교를 통해 확인할 수 있었다.

  • PDF

Effect of Composite Re-bars Embedded in Concrete on Surface Electrical Resistivity of Concrete (콘크리트내 섬유복합체 보강근이 표면저항치에 미치는 영향)

  • Moon, Do Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.6
    • /
    • pp.212-218
    • /
    • 2011
  • The effect of composite reinforcing bars on surface electrical resistivity of concrete was investigated through experimental program. The resistivity was measured by Wenner method using an equipment with 4 probe. Ordinary steel, GFRP, and CFRP reinforcing bars produced domestically were used and a specimen with no reinforcement was tested for the comparison. This investigation is motivated from the fact that measured value of resistivity of concrete is significantly affected by details of steel reinforcements, such as location, depth and direction of the internal steel reinforcement. These results could be valuable data for evaluation of corrosion degree of concrete structures reinforced or strengthened by the composite reinforcing bars.

Examples for Underwater Repair and Strengthening of Bridge Substructures (수중부 하부 구조의 보수 보강)

  • 유동우
    • Magazine of the Korea Concrete Institute
    • /
    • v.13 no.2
    • /
    • pp.38-43
    • /
    • 2001
  • 교량 하부구조 특히 교각 및 기초의 경우는 지반 또는 수중에 묻혀 있기 때문에 손상을 발견하기도 어렵고 또한 손상의 보수 및 보강이 곤란한 경우가 많다. 하부구조의 손상은 지반의 마모, 침하, 측방유동토압, 하상세굴, 홍수류, 선박 및 유하물에 의한 충격, 지진 등의 여러 원인에 의하여 발생된다. 이러한 손상은 지표수 및 지하수 배제공, 성토공, 지반개량공, 단면보수공, 세굴방지공, 내진보강공 등에 의하여 보수 및 보강이 행하여 진다. 본 고에서는 이러한 하부구조의 보수.보강공법 중 수중부에 실시되는 방법에 대하여 소개하고자 한다.

Experimental Study on the Flexural Performance of Steel Beams Reinforced by AFRP Sheets (아라미드 섬유 쉬트를 이용한 철골 보 부재의 휨 보강 성능에 관한 실험적 연구)

  • Kim, Kang Seok;Nah, Hwan Seon;Kim, Kang Sik;Lee, Hyeon Ju;Lee, Kang Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.2
    • /
    • pp.61-69
    • /
    • 2011
  • Fiber Reinforced Plastic (FRP) sheets have been widely used to retrofit and rehabilitate RC structures, while in case of retrofitting steel structures, there are no codes and researches. It stems from configuration of member and characteristics of bonding behavior. This study focused on the static behavior of steel beams reinforcement by AFRP sheets. The main objective of the experimental programme was the evaluation of the force transfer mechanism, the increment of the beam load carrying capacity and the bending stiffness. A bending test was conducted on a H-shaped steel beam, with aramid FRP sheets bonded to its flanges. The mid-span deflection and the strain from three points along AFRP sheets were recorded Test results exhibit that the increment of the load-carrying capacity with reference to a mid-span deflection level of 15 mm(1/125mm of the clear span) was equal to 9.4% and for the two layers case, an elastic stiffness increment is slightly higher than one layer case.

Bonding Characteristics of Basalt Fiber Sheet as Strengthening Material for Railway Concrete Structures (Basalt 섬유쉬트의 철도시설 콘크리트구조물 보강재로서의 부착거동 연구)

  • Park, Cheol-Woo;Sim, Jong-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.641-648
    • /
    • 2009
  • Concrete structures become more common in railway systems with an advancement of high speed train technologies. As the service life of concrete structures increases, structural strengthening for concrete structures may be necessary. There are several typical strengthening techniques using steel plate and fiber reinforced polymer (FRP) materials, which have their own inherent shortcomings. In order to enhance greater durability and resistance to fire and other environmental attacks, basalt fiber material attracts engineer's attention due to its characteristics. This study investigates bonding performance of basalt fiber sheet as a structural strengthening material. Experimental variables include bond width, length and number of layer. From the bonding tests, there were three different types of bonding failure modes: debonding, rupture and rip-off. Among the variables, bond width indicated more significant effect on bonding characteristics. In addition the bond length did not contribute to bond strength in proportion to the bond length. Hence this study evaluated effective bond length and effective bond strength. The effective bond strength was compared to those suggested by other researches which used different types of FRP strengthening materials such as carbon FRP.

Flexural Behavior of High-strength Concrete Beam Reinforced with AFRP rebar (AFRP rebar로 보강된 고강도 콘크리트 보의 휨 거동)

  • Won, Dong-Min;Joe, Jang-Se;Lee, Young-Hak;Kim, Hee-Cheul
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.323-326
    • /
    • 2009
  • 콘크리트의 보강재로 높은 인장 강도와 비부식성, 비자기성, 비전기성 등의 장점을 갖는 FRP의 사용에 대한 연구가 활발히 진행되고 있다. 하지만 FRP가 갖는 낮은 탄성계수와 취성적 성질로 인해 기존 설계방법을 적용하기에는 문제가 있다. 본 연구에서는 보강비 변화에 따른 AFRP 보강 콘크리트 보의 구조 실험을 수행하여 FRP 보강근을 사용한 콘크리트 부재의 휨 성능 연구에 대한 기초적 자료를 제공하고자 하였다. 각 실험체의 결과 데이터를 비교 분석한 결과 균형보강비를 기준으로 저보강 실험체는 FRP의 파단에 의해 급격한 파괴양상을 보인 반면에, 과보강 실험체는 콘크리트가 압괴하는 파괴 징후를 보이며 파괴에 도달하였다. FRP 보강근을 사용한 보 부재의 설계에 균형보강 이상의 설계가 요구되며, 과보강의 경우 고강도 콘크리트의 사용이 요구되는 것으로 분석되었다.

  • PDF

Experimental Verification of Flexural Response for Strengthened R/C Beams by Stirrup Partial-Cutting Near Surface Mounted Using CFRP Plate (CFRP 플레이트 적용 스터럽 부분절단형 표면매립공법으로 보강된 철근콘크리트 보의 휨 거동에 대한 실험적 평가)

  • Oh, Hong-Seob;Sim, Jong-Sung;Ju, Min-Kwan;Lee, Gi-Hong
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.671-679
    • /
    • 2008
  • The near surface mounted (NSM) FRP strengthening method has been conventionally applied for strengthening the deteriorated concrete structures. The NSM strengthening method, however, has been issued with the problem of limitation of the cutting depth which is usually considered as concrete cover depth. This may be related with degradation of bonding performance in long-term service state. To improve the debonding problem, in this study, the Stirrup partial-cutting NSM (SCNSM) strengthening method using CFRP plate was newly developed. SCNSM strengthening method can be effectively applied to the deteriorated concrete structure without any troubles of insufficient cutting depth. To experimentally verify the structural behavior, the flexural test of the concrete beam by using the SCNSM strengthening method was conducted with the test variable as the strengthening length (32%, 48%, 70%, 80%, 96% of span length). In the result of the test, the NSM and SCNSM strengthened specimen showed similar structural behavior with load-deflection, mode of failure. Additionally, there was no apparent structural degradation by the stirrup partial-cutting. Consequently, it was evaluated that the SCNSM strengthening method can be useful for seriously damaged concrete structures that is hard to apply the conventional NSM strengthening method for increasing the structural capacity.

Structural Characteristics of Reinforced Concrete Beam-Column Joints Repaired and Restrengthening (재보수-보강된 철근콘크리트 보-기둥 접합부의 구조특성)

  • Cho, Chang-Ho;Kim, Jeong-Sup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.2
    • /
    • pp.231-238
    • /
    • 2003
  • Reinforced concrete buildings damaged by earthquake which can be reused can ensure the stability in its structure by repair-restrengthening, but when such a repair-restrengthening is conducted inappropriately or its structural strength is greatly reduced by earthquake again, it should have repair-restrengthening. This study selects beam-column joints which are vulnerable to earthquake as the object of experiment, performs repair-restrengthening after applying the first and the second dynamic loading to the objects of experiment, examines the capacity of restrengthening according to structural characteristics and loading velocity and verifys the validity of repair-restrengthening.