• Title/Summary/Keyword: 교정효과

Search Result 667, Processing Time 0.028 seconds

Histologic changes of tooth and periodontal tissues applying to contraction & intrusion force for the maxillary four incisors of dogs (성견 상악 4절치의 Contraction과 압하시 치아 및 주위 조직의 조직학적 변화에 관한 실험 연구)

  • Kim, Young-Kuk;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.535-549
    • /
    • 1999
  • The Purposes of this study were to investigate the initial tissue changes on the teeth and surrounding tissues under contraction and intrusive force by contraction UTA. A control and experimental dogs, 10-months in age, were studied. Contraction and intrusive force(60gm) were applied at upper four incisors by contraction UTA. Experimental dogs were sacrificed at 2 weeks and 4 weeks after force application, respectively. In this study, 2 experimental groups were designed by the duration of force applied(E1, E2). The specimens were taken around the upper first and second incisor in each groups and were prepared for the H-E and MT stain for light microscopic observation. From the results of the study, the following conclusions may be drown. : 1. In control group, the periodontal ligament width was constant from apical third to cervical third of the root and periodontal fiber arrangement was horizontal or oblique in cervical third, oblique in middle third and apical third. In alveolar bond, smooth appearance was shown with osteoblast. 2. In experimental group 1, in proportion to force was concentrated at labial middle third and apical third of root of the upper first and second incisors, root of these tooth tipped labially and intruded at a time. 3. In experimental group 2, periodontal ligament width and arrangement was similar to control and observed strong calcified response at the labial middle third of root. But, alveolar bond resorption and cementum resorption were as before seen at labial middle third and apical third of root that force was concentrated.

  • PDF

Efficiency of ceramic bracket debonding with the Er:YAG laser (세라믹 브라켓의 제거 시 Er:YAG 레이저의 효능)

  • Suh, Chung-Hwan;Chang, Na-Young;Chae, Jong-Moon;Cho, Jin-Hyoung;Kim, Sang-Cheol;Kang, Kyung-Hwa
    • The korean journal of orthodontics
    • /
    • v.39 no.4
    • /
    • pp.213-224
    • /
    • 2009
  • Objective: The aim of this study was to find out whether Er:YAG laser can aid in debonding ceramic brackets, and to see what kind of method will be the most appropriate for debonding. Methods: One hundred and ninety teeth, monocrystalline brackets ($MISO^{TM}$, HT, Ansan-Si, Korea), polycrystalline brackets ($Transcend^{TM}$ series 6000, 3M Untek, Monrovia, CA, USA) and the KEY Laser3 (KavoDental, Biberach, Germany) were used. Experimental groups were classified according to the type of ceramic brackets, and the amount of laser energy (0, 140, 300, 450, 600 mJ). After applying laser on the bracket at two points at 1 pulse each, the shear bond strength was measured. The effect of heat caused by laser was measured at the enamel beneath the bracket and pulp chamber. After measuring the shear bond strength, adhesive residue was evaluated and enamel surface was investigated using SEM. Results: All ceramic bracket groups showed a significant decrease in shear bond strength as the laser energy increased. The greatest average temperature change was $3.78^{\circ}C$ on the enamel beneath the bracket and $0.9^{\circ}C$ on the pulp chamber. Through SEM, crater shape holes caused by the laser was seen on the enamel and adhesive surfaces. Conclusions: If laser is applied on ceramic brackets for debonding, 300 - 450 mJ of laser energy will be safe and efficient for monocrystalline brackets ($MISO^{TM}$), and about 450 mJ for polycrystalline brackets ($Transcend^{TM}$ series 6000).

The effect of admixture of vitamin $D_3$ and dexamethasone on the activity of osteoblastic cells (Vitamin $D_3$와 Dexamethasone의 복합 투여가 골모세포에 미치는 영향에 관한 연구)

  • Lim, Na-Won;Park, Young Joo;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.29 no.3 s.74
    • /
    • pp.383-397
    • /
    • 1999
  • Bone is a dynamic tissue which is constantly remodelled by subsequent cycles of bone resorption and formation. Glucocorticoid and vitamine $D_3$ are known as regulating substances in bone metabolism. In vitro experiments using bone tissue, it was suggested that glucocorticoid inhibits bone resorption, whereas the effect of glucocorticoid on bone formation are complex- increasing or decreasing effect. The active form of vitamin $D_3$, 1,25-dihydroxycholecalciferol[1.25-$(OH)_2D_3$], has been reported to stimulate osteoblastic activities including the production of ALP, type I collagen, and osteoclacin. The purpose of this study was to evaluate the effect of admixture of vitamin $D_3$ and dexamethasone, one of glucocorticoids, on osteoblastic cell line(MC3T3-E1). Alkaline phosphatase(ALP) and MTT assay were conducted in the cultivated cells with 1, 10, 100nM/ml of 1,25-$(OH)_2D_3$ and/or 10nM/ml, 100nM/ml, $1{\mu}M/ml$ of dexamethasone. The observed results were as follows. 1. The activity of osteoblastic cells with $1{\mu}M/ml$ of dexamethasone was significantly increased at 1-day cultivation with comparison to control group, but was decreased afterwards. But the activity of ALP was greatest in $1{\mu}M/ml$ of dexamethasone and increased with time lapsed. 2. The activity of osteoblastic cells with vitamin $D_3$ was significantly increased dose-dependently at 1-day cultivation, but was significantly decreased in l00nM/.ml at 2-day cultivation, and was a little increased again at 3-day cultivation. The activity of ALP was increased in 10nM/ml or 100nM/ml at 2-day or 3-day cultivation, and was greatest in 100nM/ml at 3-day cultivation. 3. In case of admixture of dexamethasone and vitamin $D_3$, the cellular activity was decreased in any concentration of vitamin $D_3$ at 2-day cultivation, but was increased again at 3-day cultivation, which was greater than that in control or dexamethasone only group. The activity of ALP was decreased at 1-day cultivation, but was increased in the admixture of 10nM/ml or 100nM/ml of dexamethasone with 100nM/ml of vitamin $D_3$ at 2-day cultivation, and was again decreased at 3-day cultivation.

  • PDF

Evaluation of Radiation Exposure Dose for Examination Purposes other than the Critical Organ from Computed Tomography: A base on the Dose Reference Level (DRL) (전산화단층촬영에서 촬영 목적 부위와 주변 결정장기에 대한 피폭선량 평가: 선량 권고량 중심으로)

  • Lee, Seoyoung;Kim, Kyunglee;Ha, Hyekyoung;Im, Inchul;Lee, Jaeseung;Park, Hyonghu;Kwak, Byungjoon;Yu, Yunsik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.121-129
    • /
    • 2013
  • In this study measured patient exposure dose for purpose exposure area and peripheral critical organs by using optically stimulated luminescence dosimeters (OSLDs) from computed tomography (CT), based on the measurement results, we predicted the radiobiological effects, and would like to advised ways of reduction strategies. In order to experiment, OSLDs received calibration factor were attached at left and right lens, thyroid, field center, and sexual gland in human body standard phantom that is recommended in ICRP, and we simulated exposure dose of patients in same condition that equal exposure condition according to examination area. Average calibration factor of OSLDs were $1.0058{\pm}0.0074$. In case of left and right lens, equivalent dose was measure in 50.49 mGy in skull examination, 0.24 mGy in chest, under standard value in abdomen, lumbar spine and pelvis. In case of thyroid, equivalent dose was measured in 10.89 mGy in skull examination, 7.75 mGy in chest, 0.06 mGy in abdomen, under standard value in lumber spine and pelvis. In case of sexual gland, equivalent dose was measured in 21.98 mGy, 2.37 mGy in lumber spine, 6.29 mGy in abdomen, under standard value in skull examination. Reduction strategies about diagnosis reference level (DRL) in CT examination needed fair interpretation and institutional support recommending international organization. So, we met validity for minimize exposure of patients, systematize influence about exposure dose of patients and minimize unnecessary exposure of tissue.

Analysis of Complications Associated with the Nuss Procedure: Risk Factors and Preventive Measures (너스수술의 합병증에 대한 고찰: 위험인자 분석과 예방책의 제시)

  • Park, Hyung-Joo;Chang, Won-Ho;Jeon, Cheol-Woo;Park, Han-Gyu;Lee, Seock-Yeol;Lee, Cheol-Sae;Youm, Wook;Lee, Kihl-Roh
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.524-529
    • /
    • 2004
  • Background: Since the Nuss procedure for the correction of pectus excavatum is in its early stage, there have been problems that need to be solved. We examined complications in a single-institute experience of the Nuss technique in order to develop possible solutions to prevent them. Material and Method: 335 consecutive patients, who underwent the modified Nuss procedure between August 1999 and October 2002, were studied retrospectively. Median age was 8 years (range 1 to 46). 264 patients (78.8%) were in pediatric group (age$\leq$15) and 71 patients (21.2%) were in adult group (age> 15). 193 patients (57.6%) had symmetric and 142 patients (42.4%) had asymmetric pectus configurations. Risk factors predicting postoperative complications were analyzed using multi-variate logistic regression. Result: Postoperative complication rates were 18.9% (61/335) in total patients. Frequent complications were pneumothorax 24 (7.5%), bar displacement 11 (3.4%), and wound seroma 10 (3.1%) in order. Early complications (within a month, 49 cases, 15.2%) were pneumothorax (n=23, 6.9%), wound seroma (n=12, 3.6%), and bar displacement (n=8, 2.4%). Late complications (after a month, 12 cases, 3.7%) were pericarditis and pericardial effusion (n=5, 1.5%), bar displacement (n=4, 1.2%), and hemothorax (n=3, 0.9%). Techniques were modified to prevent complications especially in bar shaping and fixation, which led to decrease complication rate in later experience (Operation Date 1: 15/51 (29.4%) vs Operation Date 2: 34/284 (12.0%), p=0.004). Grand Canyon type (eccentric long canal type) showed higher complication rate than other types (GC type: 12/30(40%) vs Others: 37/305 (12.1%), p<0.001). Major risk factors are severity of pectus (OR=2.88, p=0.038), Grand Canyon type (OR=2.82, p=0.044), and Op. Date 1 (OR=4.05, p=0.001). Conclusion: Major complications were related to severe eccentric type of pectus configuration (Grand Canyon type) and lack of surgeon's experience (Op. Date 1). Com-plication rate was reduced with accumulation of experience and advancement of surgical techniques. The Nuss procedure can be performed at a low risk of complications with our current technique.

THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PHENOMENON PRODUCED DURING RETRACTION OF FOUR MAXILLARY INCISORS (상악 4절치의 후방견인시 나타나는 현상에 관한 유한요소법적 분석)

  • Cheon, Ok-Jin;Kim, Tae-Woo;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.525-541
    • /
    • 1995
  • This study was designed to investigate force systems and tooth movements produced by retraction archwire during retraction of four maxillary incisors after the maxillary canine retraction into the maxillary first premolar extraction space using the computer-aided three-dimensional finite element method. A three-dimensional finite element model, consisting of 2248 elements and 3194 nodes, was constructed. The model consisted of maxillary teeth and surrounding periodontal membranes, .022'$\times$.028'-slot brackets, and 5 types of retraction archwires(.019'$\times$.025' stainless steel archwire) modeled using the beam elements. The contact between the wire and the bracket slot was modeled using the gap elements because of the non-linear elastic behaviors of the contact between them. The forces and moments, End displacements produced by retraction archwire were measured at various conditions to investigate the difference according to types of loops, magnitudes of activation force, gable angle, and anterior lingual root torque. The results were expressed quantitative and visual ways in the three-dimensional method. The following conclusions can be drawn from this study.1. When the tear-drop loop archwire was activated, the mesio-distal and lingual translational movements of the teeth helped to close the extraction space, but unwanted movements of the teeth including intrusions and extrusions, and rotational movements in each direction occurred. 2. Activation of T-loop archwire compared with those of other types of retraction archwires produced the least translational movements of the teeth helped to space closure and also the least unwanted movements of the teeth. 3. Increasing amount of activation in the tear-drop archwire led not only to increase of translational movements of the teeth helped to space closure, but also to increase of unwanted movements of the teeth. 4. Addition of gable bend in the tear-drop archwire helped anterior teeth to translational movements in the mesio-distal direction, but increased unwanted movements of the teeth 5. Addition of anterior lingual root torque in the tear-drop archwire helped central and lateral incisor to improve their facio-lingual inclination, but increased unwanted movements of the teeth.

  • PDF

The Evaluation of Quantitative Accuracy According to Detection Distance in SPECT/CT Applied to Collimator Detector Response(CDR) Recovery (Collimator Detector Response(CDR) 회복이 적용된 SPECT/CT에서 검출거리에 따른 정량적 정확성 평가)

  • Kim, Ji-Hyeon;Son, Hyeon-Soo;Lee, Juyoung;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.55-64
    • /
    • 2017
  • Purpose Recently, with the spread of SPECT/CT, various image correction methods can be applied quickly and accurately, which enabled us to expect quantitative accuracy as well as image quality improvement. Among them, the Collimator Detector Response(CDR) recovery is a correction method aiming at resolution recovery by compensating the blurring effect generated from the distance between the detector and the object. The purpose of this study is to find out quantitative change depending on the change in detection distance in SPECT/CT images with CDR recovery applied. Materials and Methods In order to find out the error of acquisition count depending on the change of detection distance, we set the detection distance according to the obit type as X, Y axis radius 30cm for circular, X, Y axis radius 21cm, 10cm for non-circular and non-circular auto(=auto body contouring, ABC_spacing limit 1cm) and applied reconstruction methods by dividing them into Astonish(3D-OSEM with CDR recovery) and OSEM(w/o CDR recovery) to find out the difference in activity recovery depending on the use of CDR recovery. At this time, attenuation correction, scatter correction, and decay correction were applied to all images. For the quantitative evaluation, calibration scan(cylindrical phantom, $^{99m}TcO_4$ 123.3 MBq, water 9293 ml) was obtained for the purpose of calculating the calibration factor(CF). For the phantom scan, a 50 cc syringe was filled with 31 ml of water and a phantom image was obtained by setting $^{99m}TcO_4$ 123.3 MBq. We set the VOI(volume of interest) in the entire volume of the syringe in the phantom image to measure total counts for each condition and obtained the error of the measured value against true value set by setting CF to check the quantitative accuracy according to the correction. Results The calculated CF was 154.28 (Bq/ml/cps/ml) and the measured values against true values in each conditional image were analyzed to be circular 87.5%, non-circular 90.1%, ABC 91.3% and circular 93.6%, non-circular 93.6%, ABC 93.9% in OSEM and Astonish, respectively. The closer the detection distance, the higher the accuracy of OSEM, and Astonish showed almost similar values regardless of distance. The error was the largest in the OSEM circular(-13.5%) and the smallest in the Astonish ABC(-6.1%). Conclusion SPECT/CT images showed that when the distance compensation is made through the application of CDR recovery, the detection distance shows almost the same quantitative accuracy as the proximity detection even under the distant condition, and accurate correction is possible without being affected by the change in detection distance.

  • PDF

Morphologic Changes of the Pulmonary Arteries after Stent Implantation on Branch Pulmonary Artery Stenosis - Impact of Pulmonary Insufficiency - (폐동맥 분지협착에 스텐트 삽입 후 유발되는 폐동맥의 형태변화 - 폐동맥 폐쇄 부전의 역할 -)

  • Kim, Me Jin;Kang, Du Cheol;Choi, Jae Young;Lee, Jong Kyun;Sul, Jun Hee;Lee, Sung Kyu
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.1
    • /
    • pp.67-75
    • /
    • 2003
  • Purpose : Intravascular stent implantation for the treatment of postoperative branch pulmonary artery(PA) stenosis has been used successfully. However, the cross sectional area of contralateral branch PA does not regress in spite of the successful dilation of the stenotic branch PA after stent implantation. We analyzed the morphologic and hemodynamic factors on the size of branch PA after successful stent implantation. Methods : The subjects in our study were 23 children who had undergone stent implantaion from Jan. 1995 to Jul. 2002 in the Division of Yonsei Pediatric Cardiology. We evaluated the cross sectional area index(CSAI) of branch PA before and after stent implantation at follow-up catheterization. We also investigated factors such as residual pulmonary stenosis, pulmonary regurgitation(PR), systolic pressure of right ventricle, and lung perfusion scan. Results : The CSAI of the RPA without stenosis changed from mean $238{\pm}17mm^2/BSA$ to mean $249{\pm}20mm^2/BSA$(P=0.47), but didn't regress. The CSAI of the LPA with stenosis was increased effectively by stent implantation from the mean $102{\pm}12mm^2/BSA$ to mean $125{\pm}11mm^2/BSA$(P< 0.05). At follow up after stent implantation, the CSAI of PA is correlated with the residual PR fraction after stent implantation. Conclusion : In a group with increased residual PR, CSAI of RPA was found to be significantly increased between the pre- and post-stages of stent implantation. So, we suspect that the pulmonary regurgitation remaining after right ventricle outlet tract(RVOT) dilatation surgery is correlated with the increase in CSAI of RPA.

Verification of Radiation Therapy Planning Dose Based on Electron Density Correction of CT Number: XiO Experiments (컴퓨터영상의 전자밀도보정에 근거한 치료선량확인: XiO 실험)

  • Choi Tae-Jin;Kim Jin-Hee;Kim Ok-Bae
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.105-113
    • /
    • 2006
  • This study peformed to confirm the corrected dose In different electron density materials using the superposition/FFT convolution method in radiotherapy Planning system. The experiments of the $K_2HPO_4$ diluted solution for bone substitute, Cork for lung and n-Glucose for soft tissue are very close to effective atomic number of tissue materials. The image data acquisited from the 110 KVp and 130 KVp CT scanner (Siemes, Singo emotions). The electron density was derived from the CT number (H) and adapted to planning system (Xio, CMS) for heterogeneity correction. The heterogeneity tissue phantom used for measurement dose comparison to that of delivered computer planning system. In the results, this investigations showed the CT number is highly affected in photoelectric effect in high Z materials. The electron density in a given energy spectrum showed the relation of first order as a function of H in soft tissue and bone materials, respectively. In our experiments, the ratio of electron density as a function of H was obtained the 0.001026H+1.00 in soft tissue and 0.000304H+1.07 for bone at 130 KVp spectrum and showed 0.000274H+1.10 for bone tissue in low 110 KVp. This experiments of electron density calibrations from CT number used to decide depth and length of photon transportation. The Computed superposition and FFT convolution dose showed very close to measurements within 1.0% discrepancy in homogeneous phantom for 6 and 15 MV X rays, but it showed -5.0% large discrepancy in FFT convolution for bone tissue correction of 6 MV X rays. In this experiments, the evaluated doses showed acceptable discrepancy within -1.2% of average for lung and -2.9% for bone equivalent materials with superposition method in 6 MV X rays. However the FFT convolution method showed more a large discrepancy than superposition in the low electron density medium in 6 and 15 MV X rays. As the CT number depends on energy spectrum of X rays, it should be confirm gradient of function of CT number-electron density regularly.

  • PDF

Induced Prism by the Categories of Spectacle Frames (안경테 종류에 따른 유발프리즘)

  • Park, Woo-Jung;Kim, Soo Woon;Hwang, Hae-Young;Yu, Dong-Sik;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.311-319
    • /
    • 2012
  • Purpose: One of the critical aspects on dispensing glasses is to match the center of pupils to the optical center of lenses as the mismatched glasses are able to induce uncomfortable effects called prism which has been known to induce phoria, a main cause for asthenopia in many cases. Therefore, we investigated the induced prism occurred by mismatching centers between the center of pupils and the optical center of lenses. Methods: In this study, total 103 subjects were examined whether the center of pupils and the optical center of lenses are matched in horizontal and vertical directions, and then, the data was categorized into 4 groups based on the structural components of glasses. Total amount of prism was compared to show the effect of the glasses frame on the prism induction, and the value of measured prism was compared with the German RAL-RG 915 regulations. Results: The results in respect to the horizontal component showed that the induced prism was not found in 10.7% of total subjects. 73.8% of total subjects were influenced by induced prism, the range of prism was in a tolerance level. However, the 15.5% of total subjects seemed to be influenced by prism which is out of the criterion of tolerance. In case of vertical component, 23.3% of total subjects showed no effects of prism while early adopting glasses, 54.4% of total subjects showed a little prism effect within the criterion of tolerance, and 22.3% of total subjects showed the prism effect out of the tolerance range. This data indicates that group A and B that are less likely adjustable by fitting induce more prism than group C and D in horizontal and vertical components. Conclusions: In higher refractive error condition, it was found that aligning the optical center of lenses with the center of pupils by pre-fitting of glasses frame minimized prism induction in horizontal and vertical components, which ameliorates ocular fatigue. Therefore, appropriate optometric dispensing through fitting by opticians and precise design about monocular PD and monocular Oh are necessary to improve visual perception.