Background: It has been known that internal thoracic artery grafting has a better patency rate compare to other graft conduits in coronary revascularization. Better patency rates can be expected in more coronary arteries with the use of bilateral internal thoracic artery. However, there were some debates on the complications after the use of bilateral internal thoracic artery. The purpose of our study was to reveal the results of bilateral internal thoracic artery. Material and Method: The 26 coronary artery bypass operations with bilateral internal thoracic artery were performed from July 2001 to May 2002. We compared the results of 8 diabetic patients to those of 18 non-diabetic patients. We compared the results of BITA (bilateral internal thoracic artery) group to those of SITA (single internal thoracic artery) group that were 20 patients and performed during same period. Result: There was no mortality. There was one wound complication in the diabetic group and one in the non-diabetic group. There were no significant differences in operation time, duration of mechanical ventilation, amount of bleeding, infusing duration of cardiotonics, and complication between two groups. There were no significant differences in results between the BITA group and the SITA group. Conclusion: There were no significant differences in early results between the BITA group and the SITA group, and there were no significant differences in results between the diabetic group and the non-diabetic group. We think coronary artery bypass grafting with the use of bilateral internal thoracic artery is considered in diabetic patients.
The da Vinci telemanipulator system (Intuitive Surgical, Sunnyvale, CA USA) is the most advanced robotic surgical system and has been increasingly used for cardiac surgical procedures. We report out first clinical experience of use of the da Vinci telemanipulator system for endoscopic harvesting of the bilateral thoracic artery andmulti-vessel small thoracotomy off pump CABG for 3-vessel disease. The da Vinci telemanipulator system has been previously utilized primarily for mitral valve surgery.
Background: To avoid the adverse effects of cardiopulmonary bypass and to overcome late vein graft failure we routinely peformed off-pump total arterial coronary revascularization. Material and Method: From July 2000 to August 2001, 104 consecutive patients underwent first elective off-pump total arterial coronary revascularization. Both internal mammary, radial and gastroepiploic arteries were used. Sequential and composite grafts were used to achieve complete revascularization. Perioperative adverse events and postoperative angiograms were analyzed. Result: A total of 252 arterial conduits were used with an average of 2.47 grafts per patient. A total of 326 distal anastomosis were performed with a mean of 3.13 distal anastomosis per patient. Cross over to on-pump occurred in seven patients (6.7%). Of these 4 were due to unstable hemodynamics during lateral or posterior wall stabilization as a result of cardiomegaly and 3 were due to uncontrolled bleeding during dissection of diffusely dimunitive deeply placed intramyocardial coronary arteries. There were no opeartive deaths. Two cases of perioperative myocardial infarction and transient neurologic complications occurred, respectively. Of the 312 distal anastomoses, 308 (98.7%) were compatible with Fitz-Gibboll A or B patency grading. Conclusion: Off-pump total arterial coronary revascularization was technically feasible in most elective cases with satisfactory early results. However, on-pump coronary bypass surgery should be considered in difficult circumstances, such as cardiomegaly or unfavorable anatomy of the target coronary artery.
Kim, Do-Kyun;Yoo, Kyung-Jong;Youn, Young-Nam;Yi, Gi-Jong;Lee, Sak;Chang, Byung-Chul;Kang, Meyun-Shick
Journal of Chest Surgery
/
v.40
no.3
s.272
/
pp.209-214
/
2007
Background: Failed percutaneous transluminal coronary angioplasty (PTCA) is occasionally required for emergency coronary artery bypass grafting (CABG). The aim of this study was to assess the outcome of patients receiving emergency CABG after failed PTCA. Material and Method: Between May 1988 and May 2005, 5712 patients underwent PTCA, where 84 (1.4%) failed. 27 patients underwent emergency CABG after failed PTCA. The mean age was $63.7{\pm}8.9\;(46{\sim}80)$ years, with 14 male patients (51.9%). Result: All patients underwent emergent surgical revascularization within 6 hours. 22 patients underwent conventional CABG and 5 underwent off-pump CABG. The causes of PTCA failure were coronary obstruction due to new thrombi formation during the procedure (n=4), coronary dissection (n=17), coronary artery rupture (n=3) and 3 due to other causes. The rate of in-hospital operative mortality after emergent operation was 18.5% (5/27). A univariate analysis revealed that patients who died more often had left anterior descending artery disease, a preprocedural shock status, postoperative use of multiple isotropics and postoperative use of intra-aortic balloon pump. The mean follow up duration was $53.6{\pm}63.4$ months. Conclusion: Although PTCA is known to be life saving, there is still a high risk for morbidity and mortality following emergency CABG after failed PTCA, despite the advancement in PTCA techniques. This result will help identify and more effectively treat patients selected for PTCA when emergency CABG is required.
In off-pump coronary artery bypass grafting (CABG), multiple proximal anastomosis may increase the risk of cerebral embolism (air, debris) and aortic injury (dissection, pseudoaneurysm). Radial artery (RA) has no intraluminal valve such as saphenous vein. We applied Cabrol technique using aortic root replacement for proximal anastomosis in off-pump CABG. Cabrol technique using RA graft can reduce numbers of proximal anastomosis and reduce number of aortic manipulation in off-pump CABG. We report a Cabrol technique for proximal anastomosis in off-pump CABG with RA graft.
We have experienced 25 cases of aortic aneurysm from October 1987 to January 1996. Patients ranged in age from 26yrs to 73yrs(mean age 52. Syrs). There were 13 males and 12 females. Eighteen cases were thoracic aneurysm and seven were abdom nal aneurysm. The cause of aneurysm were dissecting in 16cases aneurysms and non-dissecting in 9 cases. Risk factors of aortic aneurysm were hypertension, hypercholesterolemia, Marfan's syndrome. In thoracic aneurysm patients, 1'S cases of dissecting aneurysm underwent aneurysmectomy and replacement of vessel interposition graft with or without coronary artery implantation on the graft. 6 cases of non-dissecting aneurysm underwent operation with same policy as dissecting aneurysm. In 7 case of abdominal aneurysm,all patients underwent aneurysmectomy and graft interposition with straight i)r Y graft. Thcre were 5 postoperative death(mortality 20%). Several cases of complications were improved with proper managements. All survivors showed improvement in clinical symptom and sign and discharged without specific complications.
Bang Jung Hee;Woo Jong Su;Kim Si Ho;Choi Pil Jo;Cho Kwang Jo
Journal of Chest Surgery
/
v.38
no.6
s.251
/
pp.434-437
/
2005
Since the operative mortality rate of the Acute aortic dissection has been reducing, a more extensive primary repair of the dissected aorta is preferred for acute aortic dissection to reduce the needs of secondary procedures. We performed a total aortic arch replacement with distal stent-grafting in acute type A aortic dissection. The patient was a 50-years old man. He recovered from the operation and was followed up for 7 months. The pseudolumen in the descending aorta was obliterated with the stent.
We have experienced a case of coronary artery bypass surgery without extracorporeal circulation through limited anterior thoracotomy. The lesion was a single vessel disease involving the take off of the left anterior descending artery(LAD) which showed tubular lesion with irregular contour and eccentric stenosis of more than 95% luminal narrowing. Percutaneous transluminal coronary angioplasty(PTCA) seemed to have moderate success rate and moderate complication rate. A segment of left internal mammary artery(LIMA) from the second rib down to the sixth rib was harvested through the bed of resected fourth costal cartilage. Anastomosis between LIMA and LAD was performed under beating condition. The patient was extubated in the operation room and showed excellent postoperative course without complications. The coronary angiography on the postoperative 7th day revealed good patency at the anastomosis site.
Park Il;Kim Kyu Tae;Lee Jong Tae;Chang Bong Hyun;Lee Eung Bae;Cho Joon Yong
Journal of Chest Surgery
/
v.38
no.7
s.252
/
pp.489-495
/
2005
In the surgical treatment of aortic dissection, aortic arch replacement under total circulatory arrest is often performed after careful inspection to determine the severity of disease progression. Under circulatory arrest, antegrade or retrograde cerebral perfusion is required for brain protection. Recently, antegrade cerebral perfusion has been used more, because of the limitation of retrograde cerebral perfusion. This study is to compare these two methods especially in the respect to neurological complications. Material and Method: Forty patients with aortic dissection involving aortic arch from May 2000 to May 2004 were enrolled in this study, and the methods of operation, clinical recovery, and neurological complications were retrospectively reviewed. Result: In the ACP (antegrade cerebral perfusion) group, axillary artery cannulation was performed in 10 out of 15 cases. In the RCP (retrograde cerebral perfusion) group, femoral artery Cannulation was performed in 24 out of 25 cases. The average esophageal and rectal temperature under total circulatory arrest was $17.2^{\circ}C\;and\;22.8^{\circ}C$ in the group A, and $16.0^{\circ}C\;and\;19.7^{\circ}C$ in the group B, respectively. Higher temperature in the ACP group may have brought the shorter operation and cardiopulmonary bypass time. However, the length of period for postoperative clinical recovery and admission duration did not show any statistically significant differences. Eleven out of the total 15 cases in the ACP group and thirteen out of the total 25 cases in the RCP group showed neurological complication but did not show statistically significant difference. In each group, there were 5 cases with permanent neurological complications. All 5 cases in the ACP group showed some improvements that enabled routine exercise. However all 5 cases in RCP group did not show significant improvements. Conclusion: The Antegrade, cerebral perfusion, which maintains orthordromic circulation, brings moderate degree of hypothermia and, therefore, shortens the operation time and cardiopulmonary bypass time. We concluded that Antegrade cerebral perfusion is safe and can be used widely under total circulatory arrest.
Background: Side clamping of ascending aorta during proximal graft anastomosis in coronary bypassing surgery in-creases the risk of direct aortic injury as well as embolization of intimal atheroma. Heartstring proximal sealing system (Guidant Corporation, Santa Clara, Calif), developed to avoid aortic side clamping, may minimize risks of such complications. The aim of the current study is to compare the surgical outcomes of the two proximal anastomosis techniquesi.e., Heartstring system versus aortic side clamping in off pump coronary bypassing' surgery (OPCAB). Material and Method: From January 2003 to August 2008, 499 patients underwent OPCAB. Of them, proximal graft anastomosis was performed using Heartstring system in 182 patients (Group I) and conventional manual anastomosis in 317 patients (Group II). The two groups were compared for postoperative major complications and mortality. Result: Two groups showed similar characteristics in terms of preoperative demographic data, left ventricular ejection fraction, renal function and history of diabetes, hypertension and smoking. Although there was no inter-group difference in the history of cerebral ischemia (p=0.48), preoperative brain magnetic resonance angiography revealed greater incidence of severe carotid artery stenosis (>75% of lumen) in the Group I than in the. Group II (44.5% in the Group I and 30.0% in the Group II, p=0.003). There were no inter-group differences in postoperative mortality (p=0.40) and complications (p=0.47) including neurologic events (3 in the Group land 2 in the Group II, p=0.258). Whereas neurologic events all comprised transient ischemic attacks in the Group I, they comprised multiple embolic strokes in the Group II. One patient in the Group II experienced aortic dissection during proximal anastomosis which resulted in ascending aortic replacement. Conclusion: Although proximal anastomosis using Heartstring system did not show statistically significant benefit over aortic side clamping, the. absence of embolic stroke maybe a definite benefit which may be better defined through further studies over a larger cohort.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.