• Title/Summary/Keyword: 골 두께

Search Result 683, Processing Time 0.02 seconds

Effect of Bone Quality on Insertion Torque during Implant Placement; Finite Eelement Analysis (임플란트 식립 시 골질이 주입회전력에 미치는 영향에 관한 삼차원 유한요소 분석)

  • Jeong, Jae Doug;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.109-123
    • /
    • 2009
  • The aim of the study was to assess the influence of insertion torque of bone quality and to compare axial force, moment and von Mises stress using finite element analysis of plastoelastic property for bone stress and strain by dividing bone quality to its thickness of cortical bone, density of trabecular bone and existence of lower cortical bone when implant inserted to mandibular premolar region. The $Br{\aa}nemark$ MKIII. RP implant and cylindrical bone finite model were designed as cortical bone at upper border and trabecular bone below the cortical bone. 7 models were made according to thickness of cortical bone, density of trabecular bone and bicortical anchorage and von Mises stress, axial force and moment were compared by running time. Dividing the insertion time, it seemed 300msec that inferior border of implant flange impinged the upper border of bone, 550msec that implant flange placed in middle of upper border and 800msec that superior border of implant flange was at the same level as bone surface. The maximum axial force peak was at about 500msec, and maximum moment peak was at about 800msec. The correlation of von Mises stress distribution was seen at both peak level. The following findings were appeared by the study which compared the axial force by its each area. The axial force was measured highest when $Br{\aa}nemark$ MKIII implant flange inserts the cortical bone. And maximal moment was measured highest after axial force suddenly decreased when the flange impinged at upper border and the concentration of von Mises stress distribution was at the same site. When implant was placed, the axial force and moment was measured high as the cortical bone got thicker and the force concentrated at the cortical bone site. The influence of density in trabecular bone to axial force was less when cortical bone was 1.5 mm thick but it might be more affected when the thickness was 0.5 mm. The total axial force with bicortical anchorage, was similar when upper border thickness was the same. But at the lower border the axial force of bicortical model was higher than that of monocortical model. Within the limitation of this FEA study, the insertion torque was most affected by the thickness of cortical bone when it was placed the $Br{\aa}nemark$ MKIII implant in premolar region of mandible.

Ultrasonic methods for measuring the cortical bone thickness in bovine tibia in vitro (생체 외 조건의 소 경골에서 초음파를 이용하여 피질골 두께를 측정하기 위한 방법)

  • Lee, Kang Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.557-563
    • /
    • 2022
  • The cortical bone thickness of the tibia is related to fracture risk and overall bone status. The present study aims to investigate the feasibility of two different ultrasonic methods for measuring the cortical bone thickness in bovine tibia in vitro. In the reflection technique, the tibial cortical thickness was determined from ultrasonic reflections from the periosteum and the endosteum producing specific peaks in the signal envelope. In the axial transmission technique, the tibial cortical thickness was determined from ultrasonic guided wave velocities measured along the axial direction of the tibia. The cortical bone thickness determined by using the reflection technique correlated significantly with that measured by using a caliper, with a Pearson's correlation coefficient of r = 0.97 (p < 0.0001). In contrast, the correlation coefficients for the axial transmission technique were r = 0.92 (p < 0.0001) for the first arriving signal method and r = 0.89 (p < 0.0001) for the slow guided wave method. Clinical feasibility should be demonstrated with an in vivo application to address the question whether the ultrasonic methods presented here could be useful as a screening tool for osteoporosis and potentially could be applied to other skeletal sites such as the femur and the radius.

Effect of Corrugation Fluting on the Compressive Strength of Corrugated Fiberboard Box for Food Packaging (골판지의 골 성형이 식품포장용 골판지 상자의 압축강도에 미치는 영향)

  • Kim, Cheong;Her, Jae-Young;Lee, Kwang-Geun
    • Food Engineering Progress
    • /
    • v.14 no.2
    • /
    • pp.106-111
    • /
    • 2010
  • In this study, we performed corrugation fluting experiments to examine the relationship between high-low corrugation of a corrugated medium and compressive strength of corrugated containers for food packaging. A low-grade corrugated medium was found to suffer from weak tensile resistance and to be prone to stealing, which tends to produce low corrugation. In contrast, a medium with a large corrugation deviation often caused slimming during fluting and produced irregular corrugations. Experiments of high-low corrugation distribution according to corrugated medium grades indicate that a high grade medium shows a smaller ratio of low corrugation. The thickness of corrugated fiberboard is weakly correlated to the basis weight of medium, yet positively correlated to the medium thickness (y=3.9732x+4.2712, $R^{2}=0.8142$) and inversely proportional to the medium density (y=-3.1213x+6.8736, $R^{2}=0.9919$). Compressive strength of a corrugated fiberboard box is low, if made of corrugated medium with large low corrugation distribution. Compressive strength showed 13% variation with respect to medium grades and 21% variation for various test samples. The corrugation fluting of a corrugated medium is related to physical properties such as basis thickness and density.

THE BONE GRAFT DECLINED. IS THERE STILL A ROLE FOR IMPLANT SURGERY? (골 이식술이 환자에 의해 거부되는 경우 : 임프란트 술식이 여전히 치료방법으로서 의미를 가질 수 있는가에 관한 고찰)

  • Yang, Yun-Seok;Worthington, Philip
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.19 no.4
    • /
    • pp.362-366
    • /
    • 1997
  • 골의 퇴축 혹은 수술시의 절제로 인해 임플란트를 식립하기엔 불충분한 악골을 가진 환자에 있어서 골 이식술의 필요성은 오랫동안 논의 되어왔다. 골이식술은 악골의 전체 두께(full thickness)결손시 연결성(continuity)의 수복, 혹은 표면(surface)에서의 골상실시 보강(augmentation)목적으로 쓰일 수 있다. 따라서 술자들은 임플란트를 식립하기에 불충분한 악골을 가진 환자에 있어 골 이식술에 권유하게된다. 그러나, 골 이식술은 donor site 의 morbidity혹은 수술에 대한 두려운, 추가되는 비용에 대한 염려등으로 인해 환자에 의해 거부될 때가 종종 있다. 악골 결손으로 인해 골이식없이는 임플란트를 식립하기 어려운 경우에 있어서도 임플란트 술식이 여전히 해결책이 될 수 있을까? 다음의 두가지 증례를 통해 저자등은 골이식술 없이는 임플란트르 식립하기 어려운 경우에 있어서도 임플란트 술식이 여전히 치료방법으로서 의미가 있었음을 보고하는 바이다.

  • PDF

Dependencies of phase velocities of ultrasonic guided waves on cortical thickness in soft tissue-bone mimicking phantoms (연조직-골 모사 팬텀에서 피질골 두께에 대한 유도초음파 위상속도의 의존성)

  • Lee, Kang Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.587-592
    • /
    • 2021
  • Change in the cortical thickness of long bones occurring with aging and osteoporosis is known to be a risk factor for fracture. The present study aims to investigate the dependencies of phase velocities of ultrasonic guided waves on the cortical thickness in 7 soft tissue-bone mimicking phantoms consisting of acrylic plates covered by a 2 mm-thick silicone rubber layer by using the axial transmission technique with a pair of transducers with a center frequency of 200 kHz and a diameter of 12.7 mm. Two distinct propagating waves with different velocities, the First Arriving Signal (FAS) and the Slow Guided Waved (SGW), were consistently observed for all the soft tissue-bone mimicking phantoms. The FAS velocity decreased slightly with increasing thickness, whereas the SGW velocity increased strongly with increasing thickness. The FAS and the SGW velocities were found to be closely consistent with the S0 and the A0 Lamb mode velocities for a free acrylic plate, respectively, suggesting that the presence of the soft tissue mimicking material (2 mm-thick silicone rubber layer) covering the acrylic plates does not influence significantly the velocity measurements.

Correlations of Phase Velocities of Guided Ultrasonic Waves with Cortical Thickness in Bovine Tibia (소의 경골에서 유도초음파의 위상속도와 피질골 두께 사이의 상관관계)

  • Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.56-62
    • /
    • 2011
  • In the present study, the phase velocities of guided ultrasonic waves such as the first arriving signal (FAS) and the slow guided wave (SGW) propagating along the long axis on the 12 tubular cortical bone samples in vitro were measured and their correlations with the cortical thickness were investigated. The phase velocities of the FAS and the SGW were measured by using the axial transmission method in air with a pair of unfocused ultrasonic transducers with a diameter of 12.7 mm and a center frequency of 200 kHz. The phase velocity of the FAS measured at 200 kHz exhibited a very high negative correlation with the cortical thickness and that of the SGW arriving after the FAS showed a high positive correlation with the cortical thickness. The simple and multiple linear regression models with the phase velocities of the FAS and the SGW as independent variables and the cortical thickness as a dependent variable revealed that the coefficient of determination of the multiple linear regression model was higher than those of the simple linear regression models. The phase velocities of the FAS and the SGW measured at 200 kHz on the 12 tubular cortical bone samples were, respectively, consistent with those of the S0 and the A0 Lamb modes calculated at 200 kHz on the cortical bone plate.

A Clinical Report on the Effect of CRS Usage in Degenerative Temporomanibular Joint Disease with Anterior Open Bite Applying Bone Scan (전치부 개교합을 보이는 퇴행성 관절질환에서 골스캔을 이용한 중심위교합장치의 효과 평가에 대한 임상례)

  • 박상배;김병국
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.3
    • /
    • pp.289-294
    • /
    • 1998
  • 본 증례는 측두하악관절의 퇘행성 변화를 보이는 환자에서 악교정 수술의 시행 전에 중심위교합장치를 통해 측두하악관절의 안정화를 유도하고, 또한 골스캔을 이용하여 장치의 치료효과를 평가한 임상증례이다. 환자는 24세의 여성으로 5년 전부터 전치부 개교합이 발생되기 시작하였고, 고형식 저작시 좌측 전이부에 간헐적인 통증이 발생한다는 주소로 본원에 내원하였다. 임상검사상 촉진시 양측 관절낭 후방부에 압통을 호소하였으며, 각각 50, 45mm의 최대개구량 및 최대무통성 개구량을 보였다. 좌측 악관절부에서 단순 관절 잡음, 우측 악관절부에서 염발음이 청취되었으며, 저항검사 및 부하 검사에서는 특기할 반응을 보이지 않았다. 약 7mm의 전치부 개교합의 소견을 보였으며, 파노라마 사진과 횡두개 방사선 사진 소견상 양측 과두의 크기 및 하악지의 높이가 다소 작은 소견이 관찰되었고 자기공명영상 소견상 양측성 비정복성 관절원판의 전방전위가 관찰되었다. 1997년 10월 27일 첫 번째 골스캔 소견상 양측성 비정복성 관절원판의 전방위가 관찰되엇다. 골스캔의 전방 사진에서 Densitometer를 이용하여 좌, 우측 과두부위와 상악 골부위의 가장 어두운 부분의 흑화도를 측정하였다. 각각 3회씩 구하여 평균을 구하고 좌, 우측 과두 대 상악골의 흑화도의 비율을 계산하였다. 첫번째 골스캔의 평균 흑화도는 우측 과두, 좌측과두, 상악골이 각각 0.88, 0.81, 1.32 였다. 1997년 11월 4일 중심위교합장치를 장착하였고 지속적인 물리치료를 시행하였다. 1997년 12월 10일 두 번째 골 스캔을 평균 흑화도는 우측 과두, 좌측 과두, 상악골이 각각 0.33, 0.37, 088 이었다. 1998년 1월 30일 세 번째 골스캔 소견상 두 번째 골스캔과 비교하여 활성도가 감소된 소견을 보였다. 임상검사시 무통이었다. 1998년 2월 25일 술 전 교정 위해 중심위교합장치의 장작을 중지시켰다. 1998년 6월 5일 네 번째 골스캔 소견상 이전 검사들과 비교시 흡수가 감소된 소견을 보였다. 네 번째 골스캔의 평균 흑화도는 우측 과두, 좌측 과두, 상악골이 각각 0.24, 0.19, 0.85 였다. 현재 지속적인 관찰 중이며 본원 교정과에서 악교정수술 위한 술 전 교장을 시행중이다. 결국 첫 번째 골스캔의 과두 대 상악골의 평균 흑화도의 비율은 우측과 좌측이 각각 0.66, 0.61이었고 두 번째 골스캔에서는 우측과 좌측이 각각 0.37, 0.42였고, 네번째 골스캔에서는 우측과 좌측이 각각 0.28, 0.23 이었다. 각 골스캔의 과두 대 상악골의 평균 흑화도의 비율 사이에 유의한 차이가 있는지 검증하기 위해 Standard t-test 와 ANOVA를 시행하였다. 이상의 결과에서 첫 번째, 두 번째, 네 번째 골스캔으로 갈수록 좌, 우측 과두 대 상악골의 흑화도의 비율이 유의하게 감소했음을 알 수 있었다. 결론적으로 본 증례에서는 전치부 개교합이 발생되어 악교정수술이 필요한 환자에게 측두하악관절의 안정화를 위해 중심위교합장치를 사용함으로써 퇴행성 관절질환의 진행을 억제시킬 수 있고, 퇴행성 관절질환의 활성도에 대한 평가시 골스캔이 유용할 수 있음을 보여주었다고 사료된다.

  • PDF

The Short Term Clinical Results of Hemiarthroplasty to Treat Humeral Head Osteonecrosis (상완골 두 비 외상성 골괴사에 시행한 견관절 반 치환술의 단기 추시 결과)

  • Sohn, Kang-Min;Sung, Chang-Meen;Park, Hyung-Bin
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.183-189
    • /
    • 2007
  • Introduction: While uncommon, humeral head osteonecrosis is an indication for arthroplasty when the humeral head collapse is advanced. The current authors report the short-term clinical results of 7 hemiarthroplasties to treat humeral head osteonecrosis. Materials and Methods: This study focused on 7 reconstructed shoulders of 5 patients whose humeral head osteonecrosis was treated with hemiarthroplasty. The postulated causes were alcohol-induced (4 cases) and steroidinduced (3 cases). The minimum follow-up was 12 months. This study compared the preoperative and postoperative shoulder pain, range of motion, and ASES scores. The postoperative patient satisfaction was assessed. Results: The level of pain during exercise was reduced from a preoperative average of 7.6 to a postoperative average of 1.9. The range of motion, in terms of forward flexion, abduction, and external rotation, improved from preoperative averages of $105.7^{\circ}$, $80^{\circ}$, and $22.1^{\circ}$ to postoperative averages of $146.6^{\circ}$, $139.3^{\circ}$, and $44.3^{\circ}$, respectively. The ASES scores increased from a preoperative mean of 39.0 to a postoperative mean of 84.1. The patients' ratings of the outcomes were excellent (5 cases) and good (2 cases). Conclusions: These short-term results indicate that hemiarthroplasty is a reliable treatment method for humeral head osteonecrosis improving shoulder pain, range of motion, and patient satisfaction.

An Anatomical Study using CT Images for the Implantation of Micro-implants (CT 이미지를 사용한 Micro-implants 식립을 위한 매부학적 연구)

  • Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.32 no.6 s.95
    • /
    • pp.435-441
    • /
    • 2002
  • Surgical microscrews were introduced and used as one method to provide absolute anchorage. Some clinicians implanted microscrews or miniscrews into the basal bone below the roots of the teeth to evade damage to the roots. Because the implanted microscrews were positioned too low the applied force was insufficient to retract the anterior teeth or protract the posterior teeth, and the use of microscrews or miniscrews seemed limited in applying vertical force. However Park implanted microscrews(micro-implants (1.2mm in diameter)) into the alveolar bone between the roots of the posterior teeth to change the direction of the applied force toward increasing horizontal component of the force. Moreover, these microscrew implants were positioned in the alveolar bone between the roots without causing discernable damage to the roots. This study was performed to provide guidelines and anatomic data to assist in the determination of the safe location for micro-implants. By measuring the CT images from 21 patients, anatomical data were obtained which were then used as a guide to determine the location for the implantation of micro-implants. The thickness of the cortical bones at the alveaolar bone region increased from the anterior to the posterior teeth area. The mandibular posterior teeth area showed thicker cortical bone. A greater distance was observed in distance between the second premolar root and first molar root in the upper arch, between the first molar root and the second molar root in the lower arch. The alveolar bone of the posterior teeth area is considered the best site for the implantation of micro-implants.

A study on the bone thickness of midpalatal suture area for miniscrew insertion (미니스크류 식립 부위로서 정중 구개봉합부 골의 두께에 관한 연구)

  • Kyung, Seung-Hyun
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.63-70
    • /
    • 2004
  • The midpalatal suture area has some advantages for supporting miniscrews : it has no specific anatomical structure, it is composed of thick cortical bone, and covered with attached gingiva. So it is suitable area for inserting miniscrews. However, the midpalatal suture area appears thinner when seen in ceph. As a result, Clinicians can misunderstand that inserting miniscrews cause the problem, both the risk of perforation and the decrease of stability. The purpose of this article is measuring the vertical bone thickness of the midpalatal suture area for inserting miniscrews. The total of 25patient (male : 13, female : 12), who are in their twenties, were taken CT. The vertical bone thickness of the midpalatal suture area was measures from the transverse section of CT. As a result, We reached a conclusion from the differences of each area. It is as follows: 1. There is no significant difference between the thickness of male group and that of female group. 2. In coronal section, Bone thickness becomes thinner from the midpalatal suture to Left & Right side, in sagittal section, Bone thickness becomes thinner from incisive foramen to PNS. 3. The area that is within 3mm of left and right from the midpalatal suture area transversely and within 25mm backward from the incisive foramen sagittaly is enough for inserting miniscrews.