Browse > Article

Effect of Bone Quality on Insertion Torque during Implant Placement; Finite Eelement Analysis  

Jeong, Jae Doug (Department of Prosthodontics, College of Dentistry, Dankook University)
Cho, In-Ho (Department of Prosthodontics, College of Dentistry, Dankook University)
Publication Information
Journal of Dental Rehabilitation and Applied Science / v.25, no.2, 2009 , pp. 109-123 More about this Journal
Abstract
The aim of the study was to assess the influence of insertion torque of bone quality and to compare axial force, moment and von Mises stress using finite element analysis of plastoelastic property for bone stress and strain by dividing bone quality to its thickness of cortical bone, density of trabecular bone and existence of lower cortical bone when implant inserted to mandibular premolar region. The $Br{\aa}nemark$ MKIII. RP implant and cylindrical bone finite model were designed as cortical bone at upper border and trabecular bone below the cortical bone. 7 models were made according to thickness of cortical bone, density of trabecular bone and bicortical anchorage and von Mises stress, axial force and moment were compared by running time. Dividing the insertion time, it seemed 300msec that inferior border of implant flange impinged the upper border of bone, 550msec that implant flange placed in middle of upper border and 800msec that superior border of implant flange was at the same level as bone surface. The maximum axial force peak was at about 500msec, and maximum moment peak was at about 800msec. The correlation of von Mises stress distribution was seen at both peak level. The following findings were appeared by the study which compared the axial force by its each area. The axial force was measured highest when $Br{\aa}nemark$ MKIII implant flange inserts the cortical bone. And maximal moment was measured highest after axial force suddenly decreased when the flange impinged at upper border and the concentration of von Mises stress distribution was at the same site. When implant was placed, the axial force and moment was measured high as the cortical bone got thicker and the force concentrated at the cortical bone site. The influence of density in trabecular bone to axial force was less when cortical bone was 1.5 mm thick but it might be more affected when the thickness was 0.5 mm. The total axial force with bicortical anchorage, was similar when upper border thickness was the same. But at the lower border the axial force of bicortical model was higher than that of monocortical model. Within the limitation of this FEA study, the insertion torque was most affected by the thickness of cortical bone when it was placed the $Br{\aa}nemark$ MKIII implant in premolar region of mandible.
Keywords
Implant; Insertion torque; moment; axial force; finite element analysis;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Johansson P, Strid K-G. Assessment of bone quality from cutting resistance during implant surgery. Int J Oral Maxillofac Implants 1994;9:279-288
2 Schulte W, Lucas D, Muhlbradt L, Scholz F, Bretschi J, Frei D. Periotest-ein neues Verfahren und Gerat zur Messung der Function des Pardontiums. Zahnartzl Mitt 1983;73:1229-1240
3 Friberg B, Sennerby L, Roos J, Lekholm U. Identificarion of bone quality in conjunction with insertion of titanium implants. Clin Oral Implants Res 1995; 6:213-219   DOI   ScienceOn
4 Sullivan DO, Sennerby L, Jagger D, Meriedith N. A comparision of two methods of enhancing implant primary stability. Clinical Implant Dentistry and Related Research 2004;6:48-57   DOI   ScienceOn
5 Carter DR, Caler WE. Cycle dependent and time dependent bone fracture with repeated loading. J Biomech Eng 1983;105-166
6 Misch CE, Qu Z, Bibez MW. Mechanical properties of trabecular bone in the human mandible. J Oral Maxillofac Surg 1999;47:700-706
7 Petrie CS, Williams JL. Comparative elvaluation of implant design: influence of diameter, length and taper on strains in the alveolar crest. Clin Oral Implants Res 2005;16:486-494   DOI   ScienceOn
8 Weinstein AM. Klawitter JJ, Anand SC, Schuessler R. Stress analysis of porous rooted dental implants. J Dent Res 1976;55:772-777   DOI   PUBMED   ScienceOn
9 Misch CE. Density of Bone: effect on treatment plans, surgical approach, healing, and progressive loading. Int J Oral Implant 1990;6:23-31
10 Ueda M, Matsuki M, Jacobsgon M, Tjellstr$\ddot{o}$m A. The relationship between insertion torque and removal torque analyzed in fresh temporal bone. Int J Oral Maxilofac Implants 1991;6:442-447
11 Johansson CB, Albrektsson T. Integration of screw implants in the rabbit: A one-year follow-up of removal torque of titanium implants. Int J Oral Maxillofac Implants 1987:2;69-75
12 Cho IH, Lee JB, Kim YJ, Lim CJ, Yeo HH, Ryu KH Hur YG, Lee JS. Upgrade Dental Implant. Myungmun Publishing Co. Inc. 2006; 40-41
13 Beer A, Gahleitner A, Holm A, Tschabitscher M, Homolka P. Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible. Clin Oral Implants Res 2003;14: 616-620   DOI   ScienceOn
14 Frost HM. Mechanical adaptation. Frost's mechanostat theory. In Martin RB, Burr DB, editors. Structure, function, and adaptation of compact bone. New York, Baven Pres 1989:179-181
15 Carl E. Misch, Dental implant prosthodontics. Gi sung Publishing Co. Inc 2005:135-137
16 Albrektsson T, Zarb G, Worthington P, Eriksson AR. The longterm efficacy of currently used dental implant: a review and proposed criteria of success. Int J Oral Maxillofac Implants 1986;1:11-25
17 Albrektsson T, Wennerberg A. The impact of oral implant-past and future, 1966-2024. J Can Dent Assoc 2005;71:327
18 Satoh T, Maeda Y, Komiyama Y. Biomechanical rationale for intentionally inclined implants in the posterior mandible using 3D finite element analysis. Int J Oral Maxillofac Implants 2005;20:533-539
19 Ivanoff C-J, Sennerby L, Lekholm U. Influence of mono-and bicortical anchorage on the integration of titanium implants. Int J Oral Maxillofac Surg 1996;25:229-235   DOI   ScienceOn
20 Kitamura E, Stegaroiu R, Nomura S, Miyakawa O. Biomechanical aspect of marginal bone resorption around osseointegrated implants: considerations based on a three-dimensional finite element analysis. Clin Oral Implants Res 2004;15:401-412   DOI   ScienceOn
21 Meredith N. Assessment of Implant stability as a prognotic determinant. Int J Prothodont 1998;11: 491-501
22 Br$\dot{a}$nemark PI. Osseointegration and its experimental background. J Prosthet Dent 1983;50:399-409   DOI   ScienceOn
23 Carter TB, Frost DE, Tucher MR, Juniga JR. Cortical thickness in human mandibles: clinical relevance to the sagittal split ramus osteotomy. Int J Adult Orthod Orthognath Surg 1991;6:257-260