Surgical microscrews were introduced and used as one method to provide absolute anchorage. Some clinicians implanted microscrews or miniscrews into the basal bone below the roots of the teeth to evade damage to the roots. Because the implanted microscrews were positioned too low the applied force was insufficient to retract the anterior teeth or protract the posterior teeth, and the use of microscrews or miniscrews seemed limited in applying vertical force. However Park implanted microscrews(micro-implants (1.2mm in diameter)) into the alveolar bone between the roots of the posterior teeth to change the direction of the applied force toward increasing horizontal component of the force. Moreover, these microscrew implants were positioned in the alveolar bone between the roots without causing discernable damage to the roots. This study was performed to provide guidelines and anatomic data to assist in the determination of the safe location for micro-implants. By measuring the CT images from 21 patients, anatomical data were obtained which were then used as a guide to determine the location for the implantation of micro-implants. The thickness of the cortical bones at the alveaolar bone region increased from the anterior to the posterior teeth area. The mandibular posterior teeth area showed thicker cortical bone. A greater distance was observed in distance between the second premolar root and first molar root in the upper arch, between the first molar root and the second molar root in the lower arch. The alveolar bone of the posterior teeth area is considered the best site for the implantation of micro-implants.
Keywords
Micro-implant; Thickness of cortical bone; Distance between roots; Distance between bone surface and roots;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Turley PK, Kean C, Schur J. et al. Orthodontic Force Application to Titanium Endosseous Implant. Angle Orthod 1988 : 58 : 151-62
2 Dahlberg G. Statistical methods for medical and biological stu-dents. london: George Allen and Unwin: 1940
3 Kanomi R. Mini-implant for Orthodontic Anchorage, J Clin Orthod 1997: 31 : 763-7
4 Park HS. A new protocol of the sliding mechanics with micro-implant anchorage(MIA), Kor J Orthod 2000 : 30(6) : 677-85
5 Senut B. Computerized tomography of a Neanderthal humerus from Le Regourdou(Dordogne, France) : comparisons with modern man, J Hum Evol 1985 : 14 : 717-23
6 Spoor CF, Zonneveld FW, and Macho GA. Linear measurements of cortical bone and dental enamel by computed tomography: application and problems, Am J Phys Anthropol 1993 : 91 : 469-84   DOI   ScienceOn
7 Daegling OJ. Biomechanics of cross-sectional size andshape in the hominoid mandibular corpus, Am J Phys Anthropol 1989 : 80: 91-106   DOI   PUBMED   ScienceOn
8 Park HS, Kim JB. The use of titanium microscrew implant as orthodontic anchorage. Keimyung Univ Med J. 18(4) : 509-15
9 Costa A, Raffaini M, Melsen B. Miniscrews as Orthodontic An- chorage, A prelininary report Int. J. Adult. Orthod. Orthogn. Surg. 1998: 13: 201-9
10 Park HS. The use of Micro-implant as orthodontic anchorage. Nare Pub. Co. Seoul 2001
11 Gray JB, Steen ME, King GJ, Clark AE. Studies on the Efficacy of Implants as Orthodontic Anchorage. Am J Orthod 1983: 83 : 311-7   DOI   ScienceOn
12 Tsunori M, Mashita M, and Kasai K. Relatioship between facial types and tooth and bone characteristics of the mandible obtained by CT scanning, Angle Orthod 1998: 68(6) : 557-62
13 Park HS, Bae SM, Kyung HM, Sung JH Micro-implant anchorage tor treatment of a skeletal class I bialveolar protrusion, J Clin Othod 2001 : 35(7) : 417-22
14 Champy M, Pape HD, Gerlach Kl, and Lodde JP : Mandibular fraetures in Kruger E, Schilli W, and Worthington P. : Oral and maxillofacial traumatology Vol. 2 Quintessence publishing Co. Inc. Chicago, london, Berlin, Rio de Janeiro, Tokyo, 1986 pp. 19-43
15 Park HS. The skeletal cortical anchorage using titanium microscrew implants, Kor J Orthod. 1999 : 29 : 699-706
16 Roberts WE, Nelson Cl, Goodacre CJ. Rigid Implant Anchorage to Close a Mandibular First Molar Extraction Site. J Clin Orthod 1994: 28 : 693-704
17 Sherman AJ. Bone Reaction to Orthodontic Forces on Vitreous Carbon Dental Implants. Am J Orthod 1978: 74 : 79-87   DOI   ScienceOn