• Title/Summary/Keyword: 골량

Search Result 48, Processing Time 0.037 seconds

Research on the Bacillus-fermented Enzamin Administration on Human NK Cell Activity and Bone Density of Hamster: A Pilot Study (Bacillus 발효액 Enzamin의 투여가 인체의 NK세포 활성도와 Hamster의 골밀도에 미치는 탐색연구)

  • Won, Ryu Seo;Fujii, Tokio;Lee, Hyung H.
    • Journal of Naturopathy
    • /
    • v.7 no.2
    • /
    • pp.63-69
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the effects of Bacillus fermentation broth (ENM) on the human NK cell activity, and bone matrix density, matrix content and area of hamsters fed ENM. Methods: NK cell activity was tested, and bone mineral density were measured by x-ray. Results: NK cell activity was significantly higher in the control group (644.71 pg/ml) and in the test group (1796.37 pg/ml) (p<.004). Test groups were significantly increased by 1110.37 pg/ml in the pre-test and 1796.37 pg/ml in the post-test(p<.001). Behavioral observations after feeding ENM to hamsters showed normal behavior with no difference between control and test groups. The hamster body weight of the control was 106 g at the initial and final 27 days. In the test group, the initial weight was 96.6 g and the final 27 days was 114 g. No morphological changes were observed in the X-ray photographs of the hamster hind legs. The bone matrix density was 0.059 g/cm3 in control and 0.062 g/cm3 in the test, which was increased by 0.003 g/cm3. The bone matrix content was 0.175 g in the control and 0.196 g in the test. The bone area was 2.95 cm2 in the control and 3.19 cm2 in the test, which was increased by 0.19 cm2. In the autopsy, neither the control nor the test group showed any remarkable abnormality, and each organ was normal. Conclusions: It is thought that ingestion of ENM is useful for immunity enhancement.

  • PDF

Aqueous Extracts of Jibaekjihwang-tang Ameliorate Ovariectomy-induced Climacterium Symptoms in Mouse (난소적출 마우스에서 지백지황탕 열수 추출물의 갱년기 장애 개선 효과 평가)

  • Lee, Seung-Hye;Kim, Dong-Chul
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.30 no.2
    • /
    • pp.16-36
    • /
    • 2017
  • Objectives: The purpose of this study was to evaluate the anti-climacterium effects of Jibaekjihwang-tang (JBJHT), especially on estrogenic, anti-obesity, hypolipidemic, hepatoprotective against fatty liver and anti-osteoporotic effects by Ovariectomy (OVX) mice. Methods: In order to evaluate anti-climacterium effects of JBJHT, we used bilateral OVX female ddY mice. In this study, six groups were used; sham control, OVX control, estradiol, JBJHT 500, 250 and 125 mg/kg treated groups. Since 28 days after OVX surgery, JBJHT extracts were orally treated, and $17{\beta}$-estradiol $0.03{\mu}g/head$ were subcutaneously injected for 84 days, once a day. And then, we observed anti-climacterium effects classified into five categories; estrogenic, anti-obesity, hypolipidemic, hepatoprotective against fatty liver and anti-osteoporotic effects. The results were compared with $17{\beta}$-estradiol $0.03{\mu}g/head$/day subcutaneous treated OVX mice. Results: OVX control mice showed noticeable hypertrophic changes of adipocytes in abdominal fat pads, fatty liver, uterine atrophic changes, decreases of bone strength were also observed in OVX control. However, these estrogen-deficient climacterium symptoms were significantly and dose-dependently inhibited by JBJHT 500, 250 and 125 mg/kg treatment. Moreover, JBJHT 500 mg/kg showed comparable inhibitory effects as compared to those of estradiol $0.03{\mu}g/head$/day subcutaneous treatment. Conclusions: The results suggest that oral administration of JBJHT 500, 250 and 125 mg/kg has clear dose-dependent anti-climacterium effects in OVX mice.

Effect of GnRH analogue on the bone mineral density of precocious or early pubertal girls (성조숙증 혹은 조기 사춘기가 있는 여아에서 단기간의 성선자극호르몬 방출호르몬 효능약제 사용이 골밀도에 미치는 영향)

  • Lim, Jeong Sook;Han, Heon-Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.12
    • /
    • pp.1370-1376
    • /
    • 2009
  • Purpose:Treatment of precocity with gonadotropin releasing hormone analogue (GnRHa) might theoretically exert a detrimental effect on the bone mass during pubertal development. We investigated the short-term changes in bone mineral density (BMD) during GnRHa treatment and the enhancement in the changes with the co-administration of GnRHa and human growth hormone (hGH). Methods:Forty girls with precocious or early puberty who were using GnRHa for more than 1 year were enrolled. Of them, 14 concurrently received hGH. Lumbar bone mineral density was measured before and after the treatment, and bone mineral density-standard deviation scores (BMD-SDSs) were compared according to chronologic age (CA) and bone age (BA), as well as according to the administration of GnRHa alone (Group I) or the co-administration of hGH and GnRHa (Group II). Results:BMDs before and after treatment were in the normal range according to CA but were significantly lower according to BA (P<0.05). During treatment, BMD-SDSs did not change according to CA but significantly increased according to BA (P<0.05). BMD-SDSs in group I did not change during treatment according to CA or BA, while those in group II increased significantly according to BA (P<0.05), but not according to CA. Conclusion:Lumbar BMD was adequate according to CA at initial manifestation of precocity but was lower if compared to BA, that is, BMD did not increase with BA. Because co-treatment with hGH significantly increased BMD-SDSs according to BA, hGH co-treatment could be considered during GnRHa therapy.

Accurate Quality Control Method of Bone Mineral Density Measurement -Focus on Dual Energy X-ray Absorptiometry- (골밀도 측정의 정확한 정도관리방법 -이중 에너지 방사선 흡수법을 중심으로-)

  • Kim, Ho-Sung;Dong, Kyung-Rae;Ryu, Young-Hwan
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.361-370
    • /
    • 2009
  • The image quality management of bone mineral density is the responsibility and duty of radiologists who carry out examinations. However, inaccurate conclusions due to lack of understanding and ignorance regarding the methodology of image quality management can be a fatal error to the patient. Therefore, objective of this paper is to understand proper image quality management and enumerate methods for examiners and patients, thereby ensuring the reliability of bone mineral density exams. The accuracy and precision of bone mineral density measurements must be at the highest level so that actual biological changes can be detected with even slight changes in bone mineral density. Accuracy and precision should be continuously preserved for image quality of machines. Those factors will contribute to ensure the reliability in bone mineral density exams. Proper equipment management or control methods are set with correcting equipment each morning and after image quality management, a phantom, recommended from the manufacturer, is used for ten to twenty-five measurements in search of a mean value with a permissible range of ${\pm}1.5%$ set as standard. There needs to be daily measurement inspections on the phantom or at least inspections three times a week in order to confirm the existence or nonexistence of changes in values in actual bone mineral density. in addition, bone mineral density measurements were evaluated and recorded following the rules of Shewhart control chart. This type of management has to be conducted for the installation and movement of equipment. For the management methods of inspectors, evaluation of the measurement precision was conducted by testing the reproducibility of the exact same figures without any real biological changes occurring during reinspection. Bone mineral density inspection was applied as the measurement method for patients either taking two measurements thirty times or three measurements fifteen times. An important point when taking measurements was after a measurement whether it was the second or third examination, it was required to descend from the table and then reascend. With a 95% confidence level, the precision error produced from the measurement bone mineral figures came to 2.77 times the minimum of the biological bone mineral density change. The value produced can be stated as the least significant change (LSC) and in the case the value is greater, it can be stated as a section of genuine biological change. From the initial inspection to equipment moving and shifter, management must be carried out and continued in order to achieve the effects. The enforcement of proper quality control of radiologists performing bone mineral density inspections which brings about the durability extensions of equipment and accurate results of calculations will help the assurance of reliable inspections.

  • PDF

Influence of implant diameter and length changes on initial stability (임플란트의 직경과 길이 변화가 초기 안정성에 미치는 영향)

  • Cho, Jae-Myoung;Cho, Uk;Yun, Mi-Jung;Jeong, Chang-Mo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.335-341
    • /
    • 2009
  • Statements of problem: Adequate bone quality and quantity were important to achieve initial stability and to prevent early failures. However there were few published data available regarding the actual effect of dimensional change in implant geometry on initial stability. Purpose: The purpose of the current study was to investigate the influence of diameter and length changes on initial stability of implants. Material and methods: Four types of dummy bone (D1, D2, D3 and D4) consisted of cortical and cancellous layers with different thickness were simulated. Implants which had similar surface area to each other ($3.5{\times}13.0-mm$, $4.0{\times}11.5-mm$, $4.5{\times}10.0-mm$, $5.0{\times}8.5-mm$) were inserted in dummy bones. Implant stability as a function of peak insertion torque and resonance frequency values were recorded for each implant. Results: 1. Bone quality was a major influential factor to achieve initial stability (P <.05). 2. In D1, D2 and D3 dummy bones, implant stability quotient values were not significantly different to each other (P >.05), however insertion torques were increased with wider and shorter implants (P <.05). 3. In D4 dummy bone, implant stability quotient values and insertion torques were decreased with wider and shorter implants (P <.05). Conclusion: From a point of view of initial stability, it is suggested that use of wide and short implant may be helpful in avoiding bone augmentation procedures in area of adequate bone quality.

Anti-osteoporotic Activity of Gojineumja Aqueous Extracts on the Ovariectomized Mice (난소적출 마우스에서 고진음자(固眞飮子) 물 추출물의 골다공증 개선 효과)

  • Cho, Su-Yun;Kim, Dong-Chul
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.31 no.4
    • /
    • pp.16-38
    • /
    • 2018
  • Objectives: The objective of this in vivo study is to observe the anti-osteoporotic activities of Gojineumja aqueous extracts (GJEJ) on the ovariectomized (OVX) mice as compared to those of risedronate sodium (RES). Methods: Thirty five days after bilateral OVX, GJEJ was orally administered, for 35 days once a day and then the changes on the body weight and gain during experimental periods, femur weights, bone mineral density (BMD), bone strength (failure load), mineral contents - calcium (Ca) and inorganic phosphorus (IP), histological profiles and histomorphometrical analyses at sacrifice were conducted with serum biochemistry - osteocalcin contents and bone specific alkaline phosphatase (BALP) activities. And the results of GJEJ were compared with RES orally administered OVX mice. Results: As a result of OVX, noticeable increase of body weight and gains and serum osteocalcin levels, decrease of serum BALP activities, femur weights, femur Ca and IP contents, BMD and strength were observed as compared to those of sham control mice, respectively. Also, the decrease of all histomorphometrical indices indicating the bone mass and structure, and the increase of indices about resorption were also detected in the femur of OVX control. However, these estrogen-deficient osteoporotic signs were significantly and dose-dependently inhibited by 35 days of continuous oral treatment of GJEJ, at dose levels of 500, 250 and 125 mg/kg, respectively. Especially, GJEJ 500 mg/kg showed favorable inhibitory activities against estrogen-deficient osteoporosis symptoms induced by OVX as comparable to those of RES 2.5 mg/kg. Conclusions: The results in this study suggest that oral administrations of GJEJ have clear dose-dependent favorable anti-osteoporotic activities in OVX mice.

Histological Comparative Study of Rabbit Maxillary Sinus Augmentation with Bio-Oss and β-TCP (Bio-Oss와 β-TCP를 이용한 토끼 상악동 거상술 후의 조직학적 비교 연구)

  • Moon, Yong-Suk
    • Journal of Life Science
    • /
    • v.28 no.10
    • /
    • pp.1220-1232
    • /
    • 2018
  • The purpose of this animal study was to evaluate, by histological analysis, bone regeneration in rabbit maxillary sinuses with an anorganic bovine graft (Bio-Oss) and a ${\beta}-tricalcium$ phosphate (${\beta}-TCP$) grafting. Bilateral sinus augmentation procedures were performed in 12 adult male rabbits. Rectangular replaceable bony windows were made with a piezoelectric thin saw insert. In the Bio-Oss group, Bio-Oss was grafted and in the ${\beta}-TCP$ group, ${\beta}-TCP$ was grafted and covered by replaceable bony windows. The animals were sacrificed at 2, 4, and 8 weeks after the surgical procedure. The augmented sinuses were evaluated by histomorphometric analysis using hematoxylin-eosin, Masson trichrome, and tartrate-resistant acid phosphatase stains and also by immunohistochemical analysis of proliferating cell nuclear antigen (PCNA), type I collagen, and osteocalcin content. Histologically, new bone formation was found on the surface of Bio-Oss and ${\beta}-TCP$ particles from 2 weeks and continued to 8 weeks. Significant higher new bone formation was revealed in the ${\beta}-TCP$ group than in the Bio-Oss group at 8 weeks. The amount of graft materials was significantly decreased in the ${\beta}-TCP$ group and the number of osteoclasts was significantly increased in the ${\beta}-TCP$ group from 4 to 8 weeks. Immunoreactivity to PCNA was reduced at 8 weeks. The expression of type I collagen was significantly increased in the ${\beta}-TCP$ group at 2 weeks, but was significantly increased in the Bio-Oss group at 8 weeks. Immunoreactivity to osteocalcin was increased from 2 to 8 weeks. These histological results can help in the selection of graft materials for implants. Both Bio-Oss and ${\beta}-TCP$ are proven graft materials, however, these results indicate that ${\beta}-TCP$ showed better bone regeneration results in rabbit maxillary sinus augmentation.

Analysis of thermal changes in bone by various insertion torques with different implant designs (서로 다른 형태의 임플란트의 식립토크가 골에 미치는 열변화에 관한 연구)

  • Kim, Min-Ho;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Seok;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.168-176
    • /
    • 2011
  • Purpose: This study aims at investigating the influence of various insertion torques on thermal changes of bone. A proper insertion torque is derived based on the thermal analysis with two different implant designs. Materials and methods: For implant materials, bovine scapula bone of 15 - 20 mm thickness was cut into 35 mm by 40 - 50 mm pieces. Of these, the pieces having 2 - 3 mm thickness cortical bone were used as samples. Then, the half of the sample was immersed in a bath of $36.5^{\circ}C$ and the other half was exposed to ambient temperature of $25^{\circ}C$, so that the inner and surface temperatures reached $36.5^{\circ}C$ and $28^{\circ}C$, respectively. Two types of implants ($4.5{\times}10\;mm$ Br${\aa}$nemark type, $4.8{\times}10\;mm$ Microthread type) were inserted into bovine scapula bone and the temperature was measured by a thermocouple at 0.2 mm from the measuring point. Finite element method (FEM) was used to analyze the thermal changes at contacting surface assuming that the sample is a cube of $4\;cm{\times}4\;cm{\times}2\;cm$ and a layer up to 2 mm from the top is cortical bone and below is a cancellous bone. Boundary conditions were set on the basis of the shape of cavity after implants. SolidWorks was used as a CAD program with the help of Abaqus 6.9-1. Results: In the in-vitro experiment, the Microhead type implant gives a higher maximum temperature than that of the Br${\aa}$nemark type, which is attributed to high frictional heat that is associated with the implant shape. In both types, an Eriksson threshold was observed at torques of 50 Ncm (Br${\aa}$nemark) and 35 Ncm (Microthread type), respectively. Based on these findings, the Microthread type implant is more affected by insertion torques. Conclusion: This study demonstrate that a proper choice of insertion torque is important when using a specific type of implant. In particular, for the Microthread type implant, possible bone damage may be expected as a result of frictional heat, which compensates for initial high success rate of fixation. Therefore, the insertion torque should be adjusted for each implant design. Furthermore, the operation skills should be carefully chosen for each implant type and insertion torque.