• Title/Summary/Keyword: 격리 표준

Search Result 24, Processing Time 0.027 seconds

Study on Multiple Shock Wave Structures in Supersonic Internal Flow (초음속 내부유동에서 다수의 충격파 구조에 대한 연구)

  • James, Jintu K;Kim, Heuy Dong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.3
    • /
    • pp.31-40
    • /
    • 2020
  • The structure and dynamics of multiple shock waves are studied numerically using a finite volume solver for a model with nozzle exit Mach number of 1.75. At first, the shock variation based on images were analyzed using a Matlab program then later to the wall static pressure variation. The amplitude and frequency variation for multiple shock waves are analyzed. The cross-correlation between the shock location suggests that the first and the second shocks are well correlated while the other shocks show a phase lag in the oscillation characteristics. The rms values of pressure fluctuations are maximum at the shock locations while the other parts in the flow exhibit a lower value os standard deviation.

A Numerical Study on Pressure Fluctuation and Air Exchange Volume of Door Opening and Closing Speeds in Negative Pressure Isolation Room (음압격리병실에서의 병실 문의 개폐속도에 따른 실간 압력변동 및 공기교환량에 대한 해석적 연구)

  • Kim, Jun Young;Hong, Jin Kwan
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.24 no.1
    • /
    • pp.51-58
    • /
    • 2018
  • Purpose: In this study, through the comparison of the pressure fluctuation and air exchange volume in negative isolation room according to the type of the door and door opening/closing speeds, which is one of the main factors causing the cross contamination of the negative pressure isolation room, establishes standard operating procedures to prevent cross contamination in high risk infectious diseases and isolation room design. Methods: In this study, the air flow each of the room is analyzed using ANASYS CFX CODE for flow analysis. In addition, the grid configuration of the door is constructed by applying Immersed Solid Methods. Results: The pressure fluctuation due to the opening and closing of the hinged door was very large when the moment of the hinged door opened and closed. Especially, at the moment when the door is closed, a pressure reversal phenomenon occurs in which the pressure in the isolation room is larger than the pressure in the anteroom. On the other hand, the pressure fluctuation due to the opening and closing of the sliding door appeared only when the door was closed, but the pressure reversal phenomenon not occurred at the moment when the sliding door was closed, unlike the hinged door. As the opening and closing speed of the hinged door increases, the air exchange volume is increased. However, as the opening and closing speed of the sliding door is decreased, the air exchange volume is increased. Implications: According to the results of this study, it can be concluded that the pressure fluctuation due to the opening and closing of the hinged door is greater than the pressure fluctuation due to the opening and closing of the sliding door. In addition, it can be confirmed that the pressure reversal phenomenon, which may cause to reduce the containment effect in negative pressure isolation room, is caused by the closing of the hinged door. Therefore, it is recommended to install a sliding door to maintain a stable differential pressure in the negative isolation room. Also, as the opening and closing speed of the hinged door is slower and the opening and closing speed of the sliding door is faster, the possibility of cross contamination of the room can be reduced. It is therefore necessary to establish standard operating procedures for negative isolation room for door opening and closing speeds.

Feasibility of Analyzing Soil Organic Carbon Fractions using Mid-Infrared Spectroscopy (중적외선분광분석법을 이용한 토양 유기 탄소 분획 분석)

  • Hong, Seung-Gil;Shin, JoungDu;Park, Kwang-Lai;Lee, Sang-Beom;Kim, Jinho;Kim, Seok-Cheol;Shiedung, Henning;Amelung, Wulf
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.23 no.3
    • /
    • pp.85-92
    • /
    • 2015
  • For concerning the climate change issues, the carbon sequestration and importance of soil organic matter are receiving high attention. To evaluate carbon sequestration in soil is important to determine the soil organic carbon (SOC) fractions such as WESOC (Water extractable soil organic carbon), and $CO_2$ emission by soil microbial respiration. However, the analyses for those contents are time-consuming procedure. There were studied the feasibility of MIRS (Mid-Infrared Spectroscopy), which has short analysis time for determining the WESOC and an incubated carbon in this study. Oven-dried soils at $100^{\circ}C$ and $350^{\circ}C$ were scanned with MIRS and compared with the chemically analyzed WESOC and cumulative carbon dioxide generated during 30, 60, 90, and 120 days of incubation periods, respectively. It was observed that an optimized determination coefficient was 0.6937 between WESOC and untreated soil processed by spectrum vector normalization (SNV) and 0.8933 between cumulative $CO_2$ from 30 days incubation and soil dried at $350^{\circ}C$ after subtracting air-dried soil processed by 1st derivatives. Therefore, it was shown that Quantification of soil organic carbon fractions was possibility to be analyzed by using MIRS.

Design of pHEMT channel structure for single-pole-double-throw MMIC switches (SPDT 단일고주파집적회로 스위치용 pHEMT 채널구조 설계)

  • Mun Jae Kyoung;Lim Jong Won;Jang Woo Jin;Ji, Hong Gu;Ahn Ho Kyun;Kim Hae Cheon;Park Chong Ook
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.207-214
    • /
    • 2005
  • This paper presents a channel structure for promising high performance pseudomorphic high electron mobility transistor(pHEMT) switching device for design and fabricating of microwave control circuits, such as switches, phase shifters, attenuators, limiters, for application in personal mobile communication systems. Using the designed epitaxial channel layer structure and ETRI's $0.5\mu$m pHEMT switch process, single pole double throw (SPDT) Tx/Rx monolithic microwave integrated circuit (MMIC) switch was fabricated for 2.4 GHz and 5 GHz band wireless local area network (WLAN) systems. The SPDT switch exhibits a low insertion loss of 0.849 dB, high isolation of 32.638 dB, return loss of 11.006 dB, power transfer capability of 25dBm, and 3rd order intercept point of 42dBm at frequency of 5.8GHz and control voltage of 0/-3V These performances are enough for an application to 5 GHz band WLAN systems.

A Study on the Status and Direction of the Nursing Hospital Certification System (요양병원 인증제도의 현황과 방향에 대한 연구)

  • Park, Jong-won
    • Journal of Venture Innovation
    • /
    • v.5 no.1
    • /
    • pp.145-154
    • /
    • 2022
  • This study briefly compares the first-cycle certification of nursing hospitals with the second-cycle certification, reviews the changes and achievements of the second-cycle certification and the third-cycle certification, and examples of challenges and solutions in the process of preparing the third-cycle certification. In this study, it is suggested as follows. First, in order to see the practical effect of certification intended by the government, the exhibition is prepared in a short period of time before certification. Second, after the implementation of the nursing hospital certification system, research on the hospital performance of the medical institution certification system is insufficient in terms of quality and quantity. Therefore, in order to see the effect on the certification system, various research support is also required so that research on this can be actively conducted. Third, design certification standard guidelines from a long-term perspective so that the standard guidelines for certification do not change significantly, and certify not only the guidelines but also individual standards and forms that can be used by medical institutions. Fourth, in the four-cycle certification, accurate and realistic guidelines for infection control and quarantine ward operation support should be developed. The importance of managing infectious diseases will be highlighted in the future due to COVID-19. Fifth, medical institutions can improve the quality of medical care in nursing hospitals and have competitiveness if their daily activities, not short-term certification preparation, are carried out in accordance with certification standards, which affects performance. Sixth, when preparing for certification, nursing hospital officials have problems in organizing documents or processing administratively in the short term as in the past. This is also based on the certification criteria for the usual business process.

Compact Orthomode Transducer for Field Experiments of Radar Backscatter at L-band (L-밴드 대역 레이더 후방 산란 측정용 소형 직교 모드 변환기)

  • Hwang, Ji-Hwan;Kwon, Soon-Gu;Joo, Jeong-Myeong;Oh, Yi-Sok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.7
    • /
    • pp.711-719
    • /
    • 2011
  • A study of miniaturization of an L-band orthomode transducer(OMT) for field experiments of radar backscatter is presented in this paper. The proposed OMT is not required the additional waveguide taper structures to connect with a standard adaptor by the newly designed junction structure which bases on a waveguide taper. Total length of the OMT for L-band is about 1.2 ${\lambda}_o$(310 mm) and it's a size of 60 % of the existing OMTs. And, to increase the matching and isolation performances of each polarization, two conducting posts are inserted. The bandwidth of 420 MHz and the isolation level of about 40 dB are measured in the operating frequency. The L-band scatterometer consisting of the manufactured OMT, a horn-antenna and network analyzer(Agilent 8753E) was used STCT and 2DTST to analysis the measurement accuracy of radar backscatter. The full-polarimetric RCSs of test-target, 55 cm trihedral corner reflector, measured by the calibrated scatterometer have errors of -0.2 dB and 0.25 dB for vv-/hh-polarization, respectively. The effective isolation level is about 35.8 dB in the operating frequency. Then, the horn-antenna used to measure has the length of 300 mm, the aperture size of $450{\times}450\;mm^2$, and HPBWs of $29.5^{\circ}$ and $36.5^{\circ}$ on the principle E-/H-planes.

Design of an Analog Array using Enhancement of Electric Field on Floating Gate MOSFETs (부유게이트에 지역전계강화 효과를 이용한 아날로그 어레이 설계)

  • Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.8
    • /
    • pp.1227-1234
    • /
    • 2013
  • An analog array with a 1.2 double poly floating gate transistor has been developed with a standard CMOS fabrication process. The programming of each cell by means of an efficient control circuit eliminates the unnecessary erasing operation which has been widely used in conventional analog memories. It is seen that the path of the signal for both the programming and the reading is almost exactly the same since just one comparator supports both operations. It helps to eliminate the effects of the amplifier input-offset voltage problem on the output voltage for the read operation. In the array, there is no pass transistor isolating a cell of interest from the adjacent cells in the array. Instead of the extra transistors, one extra bias voltage, Vmid, is employed. The experimental results from the memory shows that the resolution of the memory is equivalent to the information content of at least six digital cells. Programming/erasing of each cell is achieved with no detectable disturbance of adjacent cells. Finally, the unique shape of the injector structure in a EEPROM is adopted as a cell of analog array. It reduces the programming voltage below the transistor breakdown voltage without any special fabrication process.

Design of an Analog Array Using Floating Gate MOSFETs (부유게이트를 이용한 아날로그 어레이 설계)

  • 채용웅;박재희
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.10
    • /
    • pp.30-37
    • /
    • 1998
  • An analog array with a 1.2 $\mu\textrm{m}$ double poly floating gate transistor has been developed with a standard CMOS fabrication process. The programming of each cell by means of an efficient control circuit eliminates the unnecessary erasing operation which has been widely used in conventional analog memories. It is seen that the path of the signal for both the programming and the reading is almost exactly the same since just one comparator supports both operations. It helps to eliminate the effects of the amplifier input-offset voltage problem on the output voltage for the read operation. In the array, there is no pass transistor isolating a cell of interest from the adjacent cells in the array. Instead of the extra transistors, one extra bias voltage, Vmid, is employed. The experimental results from the memory shows that the resolution of the memory is equivalent to the information content of at least six digital cells. Programming/erasing of each cell is achieved with no detectable disturbance of adjacent cells. Finally, the unique shape of the injector structure in a EEPROM is adopted as a cell of analog array. It reduces the programming voltage below the transistor breakdown voltage without any special fabrication process.

  • PDF

Performance Analysis of Flow Control Method Using Virtual Switchs on ATM (ATM에서 가상 스위치를 이용한 흐름 제어 방식의 성능 분석)

  • 조미령;양성현;이상훈
    • Journal of the Korea Computer Industry Society
    • /
    • v.3 no.1
    • /
    • pp.85-94
    • /
    • 2002
  • EMRCA(Explicit Max_min Rate Control Algorithm) switch, which has been proposed in the ATM(Asychronous Transfer Mode) standard, controls the ABR(Available Bit Rate) service traffic in the ATM networks. The ABR service class of ATM networks uses a feedback control mechanism to adapt to varying link capacities. The VS/VD(Virtual Source/Virtual Destination) technique offers the possibility to segment the otherwise end-to-end ABR control loop into separate loops. The improved feedback delay and the control of ABR traffic inside closed segments provide a better performance and QoS(Quality of Service) for ABR connections with respect to throughput, delay, and jitter. This paper is study of an ABR VS/VD flow control method. Linear control theory offers the means to derive correct choices of parameters and to assess performance issues, like stability of the system, during the design phase. The performance goals are a high link utilization, fair bandwidth distribution and robust operation in various environments, which are verified by discrete event simulations. The major contribution of this work is the use of linear control theory to model and design an ABR flow control method tailored for the special layout of a VS/VD switch, the simulation shows that this techniques better than conventional method.

  • PDF

Assessment of Covid-19 Response of the Medical Institutions Based on ISO Public Service Quality Management Framework (ISO 기반 공공서비스 품질관리 프레임워크를 바탕으로 한 의료기관의 COVID-19 대응 현황 평가)

  • Pyun, Jebum;Kim, Seungbeom
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.25 no.6
    • /
    • pp.69-84
    • /
    • 2020
  • This study is conducted to improve the quality of healthcare services responding to COVID-19 by applying the public service quality management framework that is developed from ISO18091:2019 by the Ministry of the Interior and Safety of South Korea. The COVID-19 pandemic has been impacting the world since early 2020, and now in November 2020, it still has not been eliminated. The Korean medical institutions were able to prevent the spread of COVID-19 by agile test and strict cohort isolation. As a result, the so-called K-medical defense has achieved a positive reputation from around the world. In this study, we check and evaluate the current status of the COVID-19 response targeting some Korean hospitals by applying a quality control checklist based on the public service quality management framework. Status of 7 categories are analyzed based on the interview with 3 medical institutions. We also suggest improvements for better medical service quality in case of COVID-19 being prolonged.