• Title/Summary/Keyword: 건축시공 현장적용

Search Result 341, Processing Time 0.023 seconds

A Study on the Development of a Construction Field Management Model based on BIM (BIM기반 건설현장 관리모델 개발에 관한 연구)

  • Jun, Young-Woong;Lee, Myoung-Sik
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.1
    • /
    • pp.127-135
    • /
    • 2010
  • As the amount of construction information used in the growing construction field increases, the importance of efficient construction field management has been growing. Accordingly, this study aims to identifythe application situation and possibility of BIM through theoretical examinations and domestic & overseas case studies of BIM, and attempts to suggest an approach to the formulation of an efficient construction field management model through the implementation of phase-oriented and cooperation entity-oriented analysis in the construction field. In the future, the conclusions of this study should be used to formulate an actual construction field management model and apply it in the field.

콘크리트 모듈 시공이음부의 설계기법

  • Yang, In-Hwan;Ju, Geon-Hyeong;Kim, Gyeong-Cheol
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2011.06a
    • /
    • pp.195-197
    • /
    • 2011
  • 플로팅 건축구조용 콘크리트 부유체 구조는 현장 근처의 제작장에서 제작한 후에 제작된 부재를 현장으로 이동하여 가설장비를 이용해 각 부재를 조립해서 함체 구조를 완성하는 방법인 프리캐스트 부재 방법을 적용하는 것이 유리하다. 따라서, 연결부의 기능과 구조적 성능을 최대한으로 유지시킬 수 있는 적절한 연결기법을 적용해야 한다. 본 연구에서는 콘크리트 함체 연결부에 적용할 수 있는 연결기법을 연구하였다.

  • PDF

Mock up test and Field Application of Black Concrete Applying Superplasticizer containing Carbon Amino Silica Black (카본아미노실리카 블랙 고성능감수제(CASB-SP)를 사용한 블랙콘크리트의 Mock-up Test 및 현장적용)

  • Hong, Seok-Min;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.6
    • /
    • pp.627-633
    • /
    • 2013
  • This paper presents the result of a mock-up test and field application of concrete that is black in color thanks to the application of superplasticizer containing carbon amino silica black (CASB-SP). Mock-up specimen with a size of $3000{\times}1500{\times}40$ mm was fabricated with black concrete applying 0.5% of CSAB-SP with 27 MPa. After dividing the zone in wall mock-up specimen, three different water repelling agents were applied to verify its effect of efflorescence prevention. It was found that the use of CASB-SP with 0.5% made the black concrete develop a highly clear black color, and the epoxy type water repelling agent had better performance in efflorescence prevention. Based on mock-up test, field application was conducted with bridge member. It was also found that the application of CASB-SP showed favorable results in black color development.

Application of Ultra High Performance Concrete with Pre-mix Binder (프리믹스 결합재를 활용한 초고성능콘크리트의 현장적용)

  • Koo, Kyung-Mo;Kim, Ki-Hoon;Hwang, Yin-Seong;Kim, Won-Ki
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.172-173
    • /
    • 2019
  • In this study, application of ultra high performance concrete(UHPC) with pre-mix binder were presented on civil, architectural and special field. The UHPC can be applied to a variety of site due to its excellent flowability, mechanical properties, impact resistance and fire resistance. It is necessary to apply the pre-mix binder to take into account the productivity and performance improvements of the UHPC.

  • PDF

Field Application of Mass Concrete Applying Hydration Heat Differential Method and Insulation Curing Method (수화발열량차 및 단열양생 공법을 활용한 매스콘크리트의 현장적용)

  • Han, Jun-Hui;Lim, Gun-Su;Shin, Se-Jun;Jeon, Choung-Keun;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.227-228
    • /
    • 2023
  • This study is tocompare and analyze the results of hydration heat analysis and on-field measurements using the method with hydration heat difference and insulation curing method for controlling hydration heat in mass concrete. As a result of the analysis, the temperature difference between the center and the surface was predicted very similarly, and the mass concrete surface was controlled to a safe level when evaluating with a temperature crack index, and after being finished, it was confirmed that there was no hydration crack.

  • PDF

Field Application of Foundation Mass Concrete Applying Hydration Heat Differential Method and Insulation Curing Method (매스콘크리트의 수화열 해석 및 현장 계측을 통한 수화발열량차 공법의 현장적용성)

  • Han, Jun-Hui;Lim, Gun-Su;Shin, Se-Jun;Jeon, Choung-Keun;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.229-230
    • /
    • 2023
  • In this study, the hydration heat differential method was applied to mass concrete structures, and the hydration heat analysis was compared and analyzed with on-site measurement results. The results showed that the temperature history measurements of mass concrete were managed at a difference of 8.4 ℃, and although there was some deviation in thermal stress, a similar trend was observed. Consequently, it was determined that the thermal stress on the surface of mass concrete is less than its tensile strength, which would prevent the occurrence of thermal cracks.

  • PDF

A Study on the Application of Quality Management to Fire Door Construction (방화문 시공시 현장품질관리지침 적용에 관한 연구)

  • Choi, Dong-ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.90-91
    • /
    • 2019
  • When the fire door is recently installed in the field, there are frequent cases where the fire door is manufactured with fire door having low quality or different structure compared to the performance that the fire door producer has confirmed in the performance test or the construction specification. Accordingly, on-site quality management and maintenance guideline for fire doors were presented. In this paper, we tried to explain the requirements for the construction of fire doors during the on-site quality management and maintenance guideline for fire doors presented in the study.

  • PDF

Analysis of BIM Impact on Preventing Rework in Construction Phase (시공단계 BIM 적용에 의한 재시공 방지 효과분석)

  • Lee, Myung-Do;Cha, Min-Su;Lee, Ung-Kyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.2
    • /
    • pp.169-176
    • /
    • 2018
  • The purpose of this study is to analyze the effects of applying BIM to the construction phase on preventing rework. Previous studies have presented the contribution of BIM in various ways, but a more practical and reliable analysis methodology are required. In this study, a BIM effect analysis methodology was proposed after collecting requirements on BIM effect analysis from field professionals. In the case study, the rework prevention effect was analyzed based on the proposed methodology. As a result, it was found that BIM application produced the rework prevention effect of approximately KRW 370,519,593. In addition, a consultation with field professionals on the suitability of the proposed methodology and effect analysis results were revealed that the results were sufficiently reliable. The results of this study can be used as efficient basic materials for research on BIM performance measurement in the future.

Evaluation of Performance of Grouts and Pipe Sections for Closed-loop Vertical Ground Heat Exchanger by In-situ Thermal Response Test (현장 열응답 시험을 통한 수직 밀폐형 지중열교환기용 그라우트와 열교환 파이프 단면의 성능 평가)

  • Lee, Chul-Ho;Park, Moon-Seo;Min, Sun-Hong;Choi, Hang-Seok;Sohn, Byong-Hu
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.7
    • /
    • pp.93-106
    • /
    • 2010
  • In performing a series of in-situ thermal response tests, the effective thermal conductivities of six vertical closed-loop ground heat exchangers were experimentally evaluated and compared one another, which were constructed in a test bed in Wonju. To compare thermal efficiency of the ground heat exchangers in field, the six boreholes were constructed with different construction conditions: grouting materials (cement vs. bentonite), different additives (silica sand vs. graphite) and the shape of pipe-sections (general U-loop type vs. 3 pipe-type). From the test results, it can be concluded that cement grouting has a higher effective thermal conductivity than bentonite grouting, and the efficiency of graphite better performs than silica sand as a thermally-enhancing addictive. In addition, a new 3 pipe-type heat exchanger provides less thermal interference between the inlet and outlet pipe than the conventional U-loop type heat exchanger, which results in superior thermal performance. Based on the results from the in-situ thermal response tests, a series of economic analyses have been made to show the applicability of the new addictives and 3 pipe-type heat exchanger.

Construction Performance Evaluation of Steel Staircase Systems based on Construction Simulation CYCLONE Techniques (건설시뮬레이션 사이클론 기법을 활용한 시스템 철골계단 공법의 현장적용성 평가)

  • Lee, Jeong-Hun;Lee, Kyung-Suk;Kim, Hyun-Mi;Kim, Young-Suk;Han, Seung-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.6
    • /
    • pp.19-26
    • /
    • 2010
  • Advanced construction technologies have been rarely applied to practical construction operations on jobsites due to a lack of quantified evaluation data of the performance of such technologies. The basic objective of this study is to suggest a feasible way for the evaluation of the performance of new technologies based on construction simulation techniques, which have been frequently used in academic research for productivity estimation. Steel staircase systems were selected as the new technology to be investigated. The simulation was implemented in various ways, such as one staircase to six staircases on a floor. The simulation results provided in this study suggest that planners are able to make a fundamental decision on the use of targeted new technology with the estimated performance data (productivity and unit costs). These findings also indicate that a simulation technique could be one of the methods appropriate for use as a planner's decision-making tool.