• 제목/요약/키워드: 건식벽체

검색결과 43건 처리시간 0.025초

건식벽체에 폴리싱타일을 적용하기 위한 유기.무기질 혼합계 타일접착제 종류에 따른 부착안정성 평가 연구 (A Study on the Estimation of Adhesive Stability According to Organic Inorganic Mixed Tile Bond Type for Application of Polishing Tile to Dry Wall System)

  • 유재강;박성규;배기선;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2001년도 학술논문발표회
    • /
    • pp.8-13
    • /
    • 2001
  • In recently, polishing tile(porcelain homogeneous polished tile) was used in the construction field as a finishing material. But, there happened some problems such as tile exfoliation by construction condition in early ages. Also, in the dry wall system which used to lightweight wall, for use of polishing tile on dry wall, the examination of adhesive stability of polishing tile is needed. In this Paper, adhesive strength of Polishing tile was investigated by tile bond types on gypsum board and non asbestos board coated by tar-urethane and polymer modified cementitious waterproofing membrane(Series I). Then, the effect of heat stress and vibration was estimated on gypsum and non asbestos board(Series II).

  • PDF

조립형 건식벽체의 차음성능 개선 공법에 관한 연구 (Method of how to improve transmission loss of dry walls)

  • 김경호;전진용;김성훈;이형기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.719-724
    • /
    • 2013
  • In the case of newly developed stud which has more performance of sound transmission loss, it is expected that sound would transmit through runner than stud. so we developed construction method of runner and stud. As a result, sound transmission loss is improved about 2 dB by using this method. But this construction method could be applied to only newly developed stud. In addition, sound leak of wall joint is about 2 dB, and it could be improved by using rubber gasket at joint.

  • PDF

스틸 하우스 적용 스틸 스터드의 형상에 따른 단열성능 비교 연구 (A Comparison Analysis on Thermal Performance According to Shape of Steel Stud Applied to Steel House)

  • 장철용;이나은;엄은정
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.241-245
    • /
    • 2009
  • The dry wall using steel stud is used to buildings in the inside and outside of the country because it has the merit that application is possible to various architecture. The purpose of this study is to measure thermal performance of dry wall which uses steel stud transformed one by using measurement equipment to decrease heat bridge of steel stud and ensure heat performance as dry wall. As a comparative performance test result, dry wall which uses steel stud transformed one has a performance enhancement compare with the dry wall using general steel stud.

  • PDF

현장실험을 통한 학교교실의 벽체 차음성능 및 측로전달소음 조사 (Investigation of the sound insulation performance of walls and flanking noises in classrooms using field measurements)

  • 류다정;박찬재;한찬훈
    • 한국음향학회지
    • /
    • 제36권5호
    • /
    • pp.329-337
    • /
    • 2017
  • 미국과 영국에서는 교실의 적정한 음환경을 제공하기 위하여 잔향시간 및 배경소음에 대한 기준이 수립되어 있다. 또한 이를 실현하기 위한 건축계획방법 및 실내마감재 적용에 대한 가이드라인을 제시하고 있다. 그러나 대한민국의 경우 학교 교실의 배경소음 기준을 만족하기 위한 가이드라인이 부족할 뿐만 아니라 이에 기초가 되는 교실 벽체의 차음성능에 대한 실태조사가 부족한 실정이다. 본 연구에서는 학교 교실의 실내외 소음에 대한 차음성능을 조사하기 위하여 대한민국 청주시 소재 중학교 2개소의 외부벽체와 실간벽체의 구조를 조사하였다. 실내외 벽체의 차음성능 및 측로전달소음을 비교분석하기 위하여 투과손실, 가중 표준화 음압레벨차, 음향 감쇠 계수, 신호대잡음비 등을 측정하였다. 연구결과 실간벽체의 경우 건식벽으로 건립된 학교의 차음성능이 습식벽보다 높게 나타났으며, 특히 중고파수대역에서 높은 차음성능을 나타내었다. 외부벽체의 경우 각 학교 별로 차음성능을 비교하였을 때 단창을 이중으로 배치한 학교보다 복층유리를 사용한 학교의 성능이 더 높은 것으로 나타났다. 또한 측로전달소음의 경우 창문을 모두 개방하거나 복도 측 창문과 문을 연 경우 기준을 초과하는 것으로 나타나 내부 소음에 의해 학생이 음성전달에 방해를 받을 수 있음을 알 수 있었다.

현장실험을 통한 건식경량벽체의 부착물에 대한 하중 저항성 평가에 관한 연구 (A Study on the Evaluation of The Load Resistancy of Lightweight Wall against Wall Attachments through Field Tests)

  • 김태익;이주민;김상헌;최수경;서치호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.183-184
    • /
    • 2015
  • Recent structural approach of the House of Commons has been an increase in demand for dry wall light due to a change in load bearing composite structure of a flat plate type structure under the name of long-life housing, attach the attachment to the wall as the needs of the residents of reserved space increases things that are on the rise. However, depending on the strength of collapse accidents is shown wall and recent wall deposits are required, a load resistance evaluation method of the deposit of the need is the situation. Therefore, in this study, for the evaluation of the evaluation of dry lightweight wall as widely used gypsum board and ALC lightweight wall of two types of laboratory the wall through the previous studies to be installed in direct co-housing to the target and field experiments I want to evaluate the different points.

  • PDF

건식 경량벽체의 내충격성 시험용 연질 충격체의 줄 길이에 따른 하중변동 특성 (Load Variation Characteristics about Rope Length of Large Soft Body of Lightweight Wall Impact Resistance test)

  • 김기준;송정현;안홍진;신윤호;지석원;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.182-183
    • /
    • 2014
  • In case of large soft body impact test at the construction site, the test conditions are different from conditions at the laboratory, and the length of rope to hold the impact specimen must be changed. In a previous study, the fact that the size of impact load is varied by the length of rope on the large soft body impact specimen was confirmed. In this study, the length of rope and fall height were set as independent variables to conduct the load analysis test. It was determined that the load fluctuation was occurred depending on the length of rope under the fall height over 100 mm, and it is concluded that the additional setup of fall height to modify the actual impact load size is required when the length of rope is below 2.5 m. In this study, the modified formula to put equal size of impact load regardless of the length of rope was extracted through the experiment.

  • PDF

공동주택의 건식 가변벽체 접합부 차음성능 향상을 위한 구조음장 특성 해석기법에 관한 연구 (Study on Structural-Acoustic Characteristics for Improving Soundproof Qualities to Changeable Wall in Apartment Buildings)

  • 김화일
    • 한국환경과학회지
    • /
    • 제18권11호
    • /
    • pp.1291-1297
    • /
    • 2009
  • The purpose of this study was to establish structural bone noise analysing method for apartments building floor with Structural-Acoustic coupling analysis. Nowadays, noise through floor is recognized as important problem with the consequence that noise isolation technique is studied in the various fields of industry. From among noise factors, resonance sound is main reason for floor's solid noise. therefore, In this study, evaluation method for composite material slab is established and that a case study is suggested with it.

한옥 축부(軸部) 시공법 개선 연구 (A Study on the Improvement of Wall Execution Method on Hanok)

  • 김도경
    • 한국산학기술학회논문지
    • /
    • 제11권7호
    • /
    • pp.2670-2675
    • /
    • 2010
  • 한옥에서 축부는 건물의 외관과 실내 환경, 공사기간 및 공사비와 밀접한 관련을 지닌 부분이다. 본 연구에서는 전통적인 시공법을 분석하여 전통 한옥의 장점으로서의 특성을 유지하면서 개선된 한옥 축부의 시공법을 제안하였다. 그 개선안은 기성품의 사용, 전체 공정의 건식 조립공법화, 기둥과 벽체의 일괄 시공, 기밀성과 단열성능 향상 등의 특성을 지닌다. 앞으로 시제품의 제작과 성능 시험 등의 단계를 거쳐야 하겠지만 한옥의 형태적 특성을 유지하면서 공사기간과 공사비를 줄이는데 일조할 수 있을 것으로 기대한다.

계층분석법(AHP)을 이용한 마감공정의 계획 및 관리요인 분석에 관한 연구 - 초고층 주거건축물 공사 건식벽체공법을 대상으로 (A Study on the Analysis of Planning and Management Factors of Finishing Works Using an Analytic Hierarchy Process)

  • 이치주;김재준;이윤선
    • 한국건설관리학회논문집
    • /
    • 제8권1호
    • /
    • pp.132-140
    • /
    • 2007
  • 건설 산업의 새로운 부가가치 영역으로 초고층 주거건축에 대한 관심과 투자가 증가하고 있다. 이러한 초고층 건축물을 시공하는 과정에서 많은 작업들이 층별로 반복적이며 동시에 진행되는 마감공사는 업체별 공사 관리 능력에 따라 공기 차이가 발생하고 있고, 이는 전체 사업 공기에 큰 영향을 주고 있는 것으로 나타났다. 마감공사의 효율적 수행을 위해서는 초고층 주거 건축물 마감공사의 현장 특성을 고려한 작업의 생산성 영향요인을 도출하고 중요 요인에 대한 중점 관리의 필요성이 제기되고 있다. 생산성 영향요인에는 기술적 요소 외에도 마감공사의 프로세스를 계획하고 관리하는 많은 복합적인 요소들이 존재한다. 본 연구에서는 계층 분석적 의사결정 기법인 AHP 분석을 통해 마감공사 프로세스의 계획 및 관리 요인측면에서 생산성 영향요인의 중요도를 분석하였다. 이와 같이 중요도가 높게 나온 요인 중 잠재 개선 효과가 큰 요인들에 대한 중점 관리 및 연구를 수행한다면 마감공사의 생산성 영향요인에 대한 이해를 높여주는 한편 실무적 관리방향을 제시함으로써 건설기업의 체계적 인 생산성 관리에 기여할 수 있을 것이다.

잔골재로서의 바텀애시를 사용한 플라이애시 시멘트 압출경화체의 공학적 특성 (Engineering Performance of Extruded Fly Ash Cement Panel with Bottom Ash)

  • 이명진;김진만;한동엽;최덕진;이근우
    • 한국건설순환자원학회논문집
    • /
    • 제3권3호
    • /
    • pp.252-260
    • /
    • 2015
  • 본 연구의 목적은 석탄회 중 바텀애시를 이용하여 시멘트압출성형 패널에 잔골재대체재(보형성 유지)의 용도로 적용을 함으로써 산업 부산물을 처리함과 동시에 새로운 용도를 창출하기 위한 기초자료를 제시하는 것이다. 선행연구에서는 건식벽체로 사용되는 시멘트 압출성형 패널에 비정제 플라이애시를 시멘트계 재료로 대체하여, 최대 80%까지 대체가 가능하였다. 하지만, 압출성형체는 압출 직후 자중에 의해 약간의 침하가 발생을 하게 되는데, 이는 반응성이 느린 플라이애시를 대량 사용한 경우에 늦은 경화로 인한 것이다. 본 연구에서는 자중에 의한 침하에 저항하기 위한 용도로 바텀애시를 잔골재대체재로의 사용가능성과 최적사용량을 검토하였다. 그 결과 바텀애시의 대체율이 증가함에 따라 압출경화체의 압출성은 저하 되었지만 관입저항성은 증가하였다. 그러므로 기존의 자중에 의한 패널의 침하현상은 잔골재 대체재를 사용함으로써 보완이 가능하였다. 또한 바텀애시 대체율 20%, 최대 입자 크기 0.6mm, 오토클레이브 양생에서 적절한 강도특성을 발현하고 있다. 본 연구의 결과를 통해 차후 바텀애시의 활용방법이 확대되고, 바텀애시를 잔골재로 활용함으로서 부가가치 상승에 기여할 것으로 예상된다.