• Title/Summary/Keyword: 강제환기

Search Result 95, Processing Time 0.037 seconds

Validation of FDS for Predicting the Fire Characteristics in the Multi-Compartments of Nuclear Power Plant (Part I: Over-ventilated Fire Condition) (원자력발전소의 다중 구획에서 화재특성 예측을 위한 FDS 검증 (Part I: 과환기화재 조건))

  • Mun, Sun-Yeo;Hwang, Cheol-Hong;Park, Jong Seok;Do, Kyusik
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.31-39
    • /
    • 2013
  • The Fire Dynamics Simulator (FDS) has been applied to simulate a full-scale pool fire in well-confined and mechanically ventilated multi-compartments representative of nuclear power plant. The predictive performance of FDS was evaluated through a comparison of the numerical data with experimental data obtained by the OECD/NEA PRISME project. To identify clearly the FDS results regarding to the user-dependence in the process of FDS implementation except for the intrinsic limitation of FDS such as simple combustion model, only the over-ventilated fire condition was chosen. In particular, the importance of accurate boundary conditions (B.C.) in mechanically ventilated system were discussed in details. It was known from FDS results that the B.C. on inlet and outlet vents did significantly affect the thermal and chemical characteristics inside the compartments. Finally, it was confirmed that the FDS imposed an accurate ventilation B.C. provided qualitatively good agreement with temperatures, heat fluxes and concentrations measured inside the nuclear-type multi-compartments.

An Exprimental Study on the Heat Transfer Performance in a Fluidized Bed Double Pipe Heat Exchanger (수직이중관식(垂直二重管式) 유동층형(流動層形) 열교환기(熱交換器)의 전열성능(傳熱性能)에 관한 실험적(實驗的) 연구(硏究))

  • Yoo, Ji-Oh;Seo, Jeong-Yun
    • Solar Energy
    • /
    • v.14 no.2
    • /
    • pp.39-50
    • /
    • 1994
  • Experiments have been conducted to measure the heat transfer coefficient and pressure drop in fluidized bed double pope heat exchangers with smooth tube and longitudinal finned tube. The effect of particle size(alumina beads; do=0.41, 0.54, 0.65, 0.77 mm) and static bed height on the heat transfer coefficient has been evaluated in terms of pumping power. The heat transfer coefficient for the smooth tube and finned tube heat exchangers has been compared with single phase double pipe heat exchanger. Results show that the heat transfer coefficients for the finned tube in $2.96{\sim}3.45$ times higher than the smooth tube. The heat transfer coefficients for the fluidized bed heat exchanger is higher than the single phase heat exchanger for the most of pumping power range tested. The maximum increase in the heat transfer coefficient for fluidized bed is 91.3% for the smooth tube and 127.1% for the finned tube.

  • PDF

A Study on the Non-Hazardous Method for complying with the Explosion Proof Criteria of the Electrolysis (수전해설비의 전기방폭 기준 만족을 위한 비방폭화 방안에 관한 연구)

  • YongGyu, Kim;ShinTak, Han;JongBeom, Park;ByungChan, Kong;GyeJun, Park;SeungHo, Jung
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.65-75
    • /
    • 2022
  • Recently, the possibility of fire and explosion due to hydrogen leakage and the resulting risk are increasing since the operating pressure of the electrolysis increases. This study performed the hazardous area classification in accordance with KS C IEC 60079-10-1 and KGS GC101 in consideration of the general operating conditions of the electrolysis. In addition, in order to achieve a To Non-hazardous, an appropriate ventilation rate was estimated to maintain a concentration of less than 25 % of the lower explosive limit. As a result, it was reviewed that the electrolysis is classified as an hazardous area when only natural ventilation is applied, and a huge amount of ventilation is required to classify it as a non-hazardous area.

Study on Ventilation Efficiency of a Mechanically Ventilated Broiler House­(I)Summer Season (강제환기식 육계사내의 환기효율성 조사연구­(I)하절기)

  • 이인복;정문성;유병기;전종기;김경원;이승기
    • Journal of Animal Environmental Science
    • /
    • v.9 no.2
    • /
    • pp.103-112
    • /
    • 2003
  • In this study, the distributions of internal climates such as air temperature, humidity, dust, ammonia gas, and air velocity were systematically measured at a mechanically ventilated broiler houses during summer season, with local weather data. The analysis was focused on the suitability, stability, and uniformity of internal climate, resulting in serious stress on chickens and decrease of productivity In the mechanically ventilated broiler house, the difference between measured and recommended air temperatures(suitability) was 10.4C in maximum during the summer time. The difference of air temperature in the house between day and night was $8.7^{\circ}C$ in maximum. And maximal hourly range of internal air temperature at 0.4m height from the floor was $3.7^{\circ}C$ suggesting it maintained thermal uniformity in the broiler house. The $NH_3$ and dust concentrations were pretty low because ventilation was fully performed. The air speed at chicken location was measured 2.2m/s and 1.7m/s, respectively without and with chicken existence.

  • PDF

The Diffusion Behavier Analysis Caused by High Pressure Natural Gas Leak in Enclosure with and without Ventilation System (I) (밀폐공간 및 강제환기공간에의 천연가스 고압분출 시 농도 확산분포 거동해석 (I))

  • Ha, Tae-Woong;Ha, Jong-Man;Kim, Eun-Ja
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.23-31
    • /
    • 2012
  • The basic understanding of gas diffusion and technology to predict the diffusion phenomena are needed to prepare against a disaster of leakage of natural gas and to design better consistent and reliable gas supply system in enclosure. The experimental results of British Gas Technology Co. are used in present study as a reference of theoretical study using CFD. The present results of 2D CFD analysis for mass flow rate of nozzle release show good agreement with experimental results within 2.6 % error. 3D CFD analysis for the characteristics of natural gas diffusion in enclosure with various ventilation patterns also gives reasonable agreement with experimental results.

A Study on the Long-term Operating plan of Ventilation System of Apartment House in terms of Energy Performance (공동주택 강제 환기 시스템의 건물에너지 측면에서의 장기적 운영 방안에 관한 연구)

  • Kim, Seung-Chul;Yoon, Jong-Ho;Baek, Nam-Choon;Shin, U-Cheul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.115-123
    • /
    • 2011
  • Because buildings recently built have been highly insulated and highly airtight, it is impossible to emit toxic substances from interior finishing materials only by natural ventilation. Therefore, they cause indoor air pollution and it may threaten the user"s health such as atopic dermatitis, bronchial asthma and (allergic) rhinitis. Domestically, users spend indoors 80 percent of their time of a day. With the increased interest in indoor air quality, the introduction of forced ventilation system for new-built apartment buildings has been legislated. However, toxic substances from indoor are mostly below there commended standard approximately 23 months later. Thus, this study has assumed the status of the apartment buildings 23 months later through a simulation, regarded $CO_2$ as an exclusive indoor air pollution source. In the process of effectively eliminating the $CO_2$, this study has also been conducted on an operating plan that can provide superior performance from the energy side.

  • PDF

Flow and Heat Transfer Analysis for the Ventilating System in Automobile Interior with a Forced Exhaust (강제배기를 수반한 자동차 실내의 환기시스템에 대한 유동 및 열전달 해석)

  • Lee Sang-Ho;Moh Jeong-Hah
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.4 s.235
    • /
    • pp.469-476
    • /
    • 2005
  • Numerical modeling has been carried out to investigate the two-dimensional air flow in automobile interior with a forced exhaust close to main air inlet for typical ventilation modes. The characteristics such as streamlines and temperature fields in the passenger compartment room with the forced exhaust are analyzed with comparison of the cases without a forced exhaust. The simulation results show that air flow on the floor near the front seat is increased with the forced exhaust for all ventilation modes. Flow recirculation in the cabin is most active in mode 2 with a vertical suction inlet in comparison with other two modes. In particular, less time is taken for air temperature to reach the inlet temperature due to the forced exhaust for the ventilation modes. Finally, it could be predicted that ventilating air flow is much improved with the forced exhaust in the interior Modeling results in this study can be applied to the optimal design of automobile interior fur air ventilation system.

Study on Ventilation Efficiency of A Mechanically Ventilated Broiler House- (I)Summer Season (강제환기식 계사의 환기성능 조사연구-(I)하절기)

  • 이인복;유병기;정문성;윤진하;전종길;김경원;김현태
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.02a
    • /
    • pp.171-176
    • /
    • 2003
  • 육계사의 대형화에 따른 최적환경조성의 중요성이 대두되고 있어서, 이에 따른 적합한 시설환경이 더욱 요구되고 있으나 적정환기가 이루어지지 않아 육계의 생산성 향상에 어려움이 많이 있다. 국내 대형육계사내 최적환경제어를 위한 주요환경변수의 기초자료가 매우 부족한 실정이다. 최 등(1999)은 육계사의 대표적인 여러 계사구조에서 온도, 습도, 유해가스농도 및 육계의 체중, SDS 발생율 및 폐사율, 도체이상 발생율 등을 조사하였다 황보 등(2002)은 3(W)$\times$5(L)$\times$3(H)의 무창계사에서 환경요소 중에 온도, 습도, 공기유속을 분석하여 환경효율을 조사하였다. 대부분의 관련연구들의 자료로는 계사내 환경 균일성, 적정성, 안정성 등을 효과적으로 분석하는 것이 어려웠다. (중략)

  • PDF

저온기 육용계사의 적정 환기체계 구명

  • 이덕수;나재천;최희철;송준익;이상진;김형호
    • Proceedings of the Korea Society of Poultry Science Conference
    • /
    • 2002.11a
    • /
    • pp.108-109
    • /
    • 2002
  • The study was carried out to iind out the suitable ventilation system of the broiler house in winter season in Korea. Ammonia (NH$_3$-N) gas concentration (4.2ppm) of the system of pipe air inlet-forced chimney outlet was lower than that of the system of side wall inlet. The growth performance of broilers in the house equiped with pipe air inlet-chimney exhaust was higher than that of other ventilation systmes in which the average daily gain, feed efficiency and heat cost per head in the system of pipe air inlet-forced chimney excretion were 45.6g, 1.71 and 35.4 won per head, respectively. When the lengths of pipe air inlets were compared, the wind speed from the 4 meter-inlet was highest. The temperature of the broiler house equipped with the pipe air inlet system was higher (5.9 ∼ 7.7$^{\circ}C$) than that of the curtains in side wall Inlet system, in which the pipe air inlet system expects the lower heat cost.

  • PDF