• Title/Summary/Keyword: 가열실험

Search Result 1,286, Processing Time 0.03 seconds

Development and evaluation of MR compatible patch antenna for hyperthermia (온열치료를 위한 MR호환 평판가열안테나 개발 및 성능평가)

  • Kim, D.H.;Chun, S.I.;Jang, M.Y.;Yoon, M.S.;Kim, Y.B.;Jung, B.D.;Nam, S.H.;Mun, C.W.
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.17-21
    • /
    • 2009
  • The thermal treatment have been combined with MRI which is able to acquire both an anatomical image with high-contrast and a thermal image, and have recently used for removing the tumor effectively. This study is to make a patch antenna which is designed to operate at 2.45GHz that has compatibility with MRI. The characteristic and specific absorption rate(SAR) were confirmed using computer simulation and confirmed a possibility of hyperthermia by performing experiment.

  • PDF

Experimental Studies on the Effect of Various Design Parameters on Thermal Behaviors of High Strength Concrete Columns under High Temperatures (다양한 설계변수에 따른 고강도 콘크리트 기둥의 열적 거동 분석을 위한 실험 연구)

  • Shin, Yeong-Soo;Park, Jee-Eun;Mun, Ji-Young;Kim, Hee-Sun
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.377-384
    • /
    • 2011
  • Although concrete is considered as fire proof materials, high strength concrete shows severe material and structural damages when exposed to fire. To understand such damages in high strength concrete structures, the effects of various design parameters and fire condition on the thermal behaviors of high strength concrete structures are investigated in this study. In order to achieve this goal, fire tests are performed on high strength concrete columns with different fire conditions and design parameters including cross sectional area, cover thickness, and reinforcement alignment. To investigate thermal behaviors, temperature distributions and amount of spalling are measured. In overall, the columns show rapidly increasing inner temperatures between 30~60 mins of the fire tests due to spalling. In detail, the higher temperature distributions are observed from the columns with the larger cross section and less cover thickness. Moreover, among the columns with same reinforcing ratio, larger number of reinforcements with the smaller diameter causes the higher temperature distribution. The findings from the experimental study allow not only understanding of thermal behaviors of high strength concrete columns under fire, but also guidance in revising fire safety design.

An Investigation of Surface Appearance of an Injection-Molded Plastic Part with Various Induction Heating Conditions (고주파 가열조건에 따른 플라스틱 사출성형품의 표면특성 고찰)

  • Sohn, Dong-Hwi;Seo, Young-Soo;Park, Keun;Lee, Kwang-Woo
    • Elastomers and Composites
    • /
    • v.44 no.4
    • /
    • pp.358-365
    • /
    • 2009
  • High-frequency induction is an efficient way to rapidly heat mold surface by electromagnetic induction. In the present work, high-frequency induction heating is applied to injection molding of a mobile phone cover in order to eliminate weldlines by efficiently raising the mold temperature. Through the induction heating experiments, the maximum temperature of $143^{\circ}C$ is obtained on the mold surface in 3s of heating, which is higher than the glass transition temperature of the resin material. An injection molding experiment is then performed with the aid of induction heating, from which we can successfully remove all the weldlines of the mobile phone cover. The effect of induction heating conditions such as the heating power and the heating time on the surface appearance is experimentally investigated.

Magnetic Properties of Magnetites at Low Temperatures (자철석의 저온 자화특성)

  • Hong, Hoa-Bin;Yu, Yong-Jae
    • Journal of the Mineralogical Society of Korea
    • /
    • v.24 no.1
    • /
    • pp.37-42
    • /
    • 2011
  • Magnetic properties at low-temperatures can diagnose the presence of certain magnetic minerals in rocks. At the Verwey transition temperature ($T_v$, ~105~120 K), magnetite transforms from monoclinic to cubic structure as the temperature increases. At the isotropic point ($T_i$, ~135 K), magnetocrystalline anisotropic constant of magnetite passes through zero (from negative to positive) as the temperature decreases so that its optimal remanence acquisition axis changes from [111] to [001]. A sharp remanence drop was observed at $T_v$ during warming of LTSIRM (low-temperature saturation isothermal remanent magnetization). For cooling of RTSIRM (room-temperature saturation isothermal remanent magnetization), the remanence decreased on passing $T_i$ and $T_v$. On warming of RTSIRM, remanence recovery becomes more prominent as the average grain size of magnetite increases. In summary, the SIRM memory decreases with increasing grain size of magnetite. A similar, but rather gradual, remanence transition occurs for natural samples due to contribution of cations other than Fe. As a non-destructive tool, low-temperature magnetic behavior is sensitive to unravel the magnetic remanence carriers in terrestrial rocks or meteorites.

Experimental Investigation of Flow Assurance due to Heating Method in Offshore Pipeline (해양플랜트 파이프라인 가열방식에 따른 유동 안정성 실험 연구)

  • Sohn, Sangho;Park, Jaebum;Lee, Jungho
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.1
    • /
    • pp.45-53
    • /
    • 2015
  • The fact that gas hydrate and/or paraffin wax is frequently plugged in offshore pipeline has been become very significant for offshore piepline flow assurance. An active electrical heating along pipeline has adapted in resolving flow assurance problem like as gas hydrate and wax plugging. This study represents a novel internal-swirled heater which was designed and fabricated for more effective heating and thermal mixing through pipeline. The internal-swirled heater suggested in this study shows higher thermal mixing performances than the conventional external-traced heater.

Experimental Study on the Water Content Formula of Fresh Concrete by Microwave Oven Drying Test Method (고주파 가열건조 시험방법에 의한 굳지 않은 콘크리트의 단위수량 추정식에 관한 실험적 연구)

  • Park, Min-Yong;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.2
    • /
    • pp.143-152
    • /
    • 2023
  • In this research, the microwave oven drying method was investigated as a potential accurate testing approach for determining the water content of fresh concrete. To do so, water content estimation formulas employed in three prominent oven drying test methods were selected, and the calculation principles for each equation, along with potential error factors arising during the actual testing process, were considered. Moreover, a concrete test was conducted to validate the possible error factors. Consequently, it was confirmed that estimation errors in the water content of fresh concrete can occur due to sample deviations arising during the wet screening process for creating mortar specimens or deviations in the coarse aggregate sampling quantity during the sample collection process.

Studies on Thermal Oxidation of Soybean Oil -I. Changes in Some Chemical and Physical Properties of a Soybean Oil during Thermal Oxidation- (대두유의 가열산화중의 특성변화 -제 1 보 : 가열산화중의 대두유의 일부 화학적, 물리적 성질의 변화-)

  • Shin, Ae-Ja;Kim, Dong-Hoon
    • Korean Journal of Food Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.257-264
    • /
    • 1982
  • In the present stud changes of some chemical and physical properties of a soybean oil, aerated at 120 ml/min through a porous gas distributor and oxidized at $45^{\circ}C{\sim}180^{\circ}C$, was investigated. The results of the study were as follows: The peroxide, thiobarbituric acid, and iodine value of the soybean oil which was aerated at 120 ml/min increased rapidly as oxidation temperature exceeded over $80^{\circ}C$. The acid value of the oil increased very rapidly as the oxidation temperature passed over $160^{\circ}C$. The content of the unsaturated fatty acid of the oil decreased considerably as the oxidation temperature exceeded over $80^{\circ}C$, whereas that of the saturated fatty acid did not change appreciably. This related well to the changes of the iodine value of the oil subjected to the same experimental conditions. The viscosity and refractive index of the oil increased rapidly as the oxidation temperature passed over $180^{\circ}C$. The following linear relationship hold for the viscosity and refractive index of the oil in the present study. $$V=Aexp({\frac{E}{RT}})$$ where V=viscosity(poise), A=constant, E=activation energy for viscous flow, R=gas constant, T=oxidation temperature$(^{\circ}K)$. The following relationship also hold for the viscosity and refractive index$({n^{20}}_D)$ of the oil at the present experimental conditions. $${n^{20}}_D=1.4614+7.333{\times}10^{-5}t+2.9612{\times}10^{-3}\;InV$$ where t=temperature$(^{\circ}C)$ at which the viscosity was measured.

  • PDF

Fire Damaged Behavior of Real Sized Normal Strength RC Columns (화해를 입은 실물크기 보통강도 RC 기둥의 거동)

  • Lee, Cha-Don;Shin, Yeong-Soo;Hong, Sung-Gul;Lee, Kyung-Ku;Lee, Seung-Whan
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.6
    • /
    • pp.866-876
    • /
    • 2003
  • Experiments were performed for the real sized 12 reinforced concrete columns of 350${\times}$350${\times}$3350 mm with normal concrete in order to observe the fire-damaged behavior of these columns. Columns were heated according to the ISO heating curve. Main experimental parameters were: magnitude of axial load, heating time, cover thickness, and eccentricity. Effects of these parameters on the axial expansion and contraction, rotation, buckling, ISO fire resistance, and structural stability were experimentally quantified. It has been observed that the contraction rate of axial deformation was affected mostly by the duration of heating time and buckling of reinforcement or member by the magnitude of axial load, duration of heating time, cover thickness and eccentricity in order. Based on the experimental observations, ISO fire resistance criteria were qualiatively criticized.

원전 가열운전 자동화시스템에 관한 연구

  • 김창회;박재창;김정수;정철환;함창식;박기용
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.227-232
    • /
    • 1997
  • 본 연구에서는 원자로의 충수 및 배기가 완료된 상태에서부터 원자로 출력 2%까지의 운전을 자동화한 원전 가열운전 자동화시스템을 개발하였다 본 시스템을 개발하기 위해 운전절차서와 운전원 업무경험을 바탕으로 운전모드, 자동화 범위, 자동제어대상 등을 선정하였고, 이를 기반으로 지능형 감독자시스템, 디지털 분산제어시스템, 그리고 신호연계시스템으로 구성된 가열운전 자동화시스템을 개발하였다. 개발된 시스템의 성능을 확인하기 위해 993 MWe급 가압경수로를 모의화한 계측제어 시험검증설비와 연계하여 검증 실험을 수행하였다.

  • PDF

A Study on the Design of an Annular Array Transducer for Ultrasonic Hyperthermia (초음파 Hyperthermia용 동심환 변환기의 설계에 관한 연구)

  • 조영환;성굉모
    • The Journal of the Acoustical Society of Korea
    • /
    • v.5 no.4
    • /
    • pp.37-45
    • /
    • 1986
  • 초음파 Hyperthermia를 이용한 치료는 정상세포에 열적 손상을 주지 않으면서 종양 부위만을 적당한 온도로 가열하여야 하며 따라서 종양세포와 정상세포에 대한 정확한 초음파 세기조절이 필요하 게 된다. 본 논문에서는 초음파 Hyperthermia 용 변환기로서 초점거리와 가열범위를 전자적으로 쉽게 조절할 수 있는 동심환 배열 변환기를 설계하였으며 컴퓨터 모의 실험을 통해 그 성능을 예측하였다. 설계된 변환기는 유효직경 118mm, 동작주파수 320kHz 이며 배열 요소의 수는 12개이다. 그리고 이와 같은 동심환 변환기를 동작시키기 위해 카운터를 이용한 디지털 위상 조절 회로를 설계 제작하였으며, 실험 결과, 위상차를 갖는 신호를 발생시킬 수 있었다.

  • PDF