Fire Damaged Behavior of Real Sized Normal Strength RC Columns  

Lee, Cha-Don (Dept. of Architectural Engineering, Chung-Ang University)
Shin, Yeong-Soo (Dept. of Arichitecture, Ewha womans University)
Hong, Sung-Gul (Dept. of Architecture, Seoul National University)
Lee, Kyung-Ku (Fire Insurance Laboratories)
Lee, Seung-Whan (Dept. of Architectural Engineering, Chung-Ang University)
Publication Information
Journal of the Korea Concrete Institute / v.15, no.6, 2003 , pp. 866-876 More about this Journal
Abstract
Experiments were performed for the real sized 12 reinforced concrete columns of 350${\times}$350${\times}$3350 mm with normal concrete in order to observe the fire-damaged behavior of these columns. Columns were heated according to the ISO heating curve. Main experimental parameters were: magnitude of axial load, heating time, cover thickness, and eccentricity. Effects of these parameters on the axial expansion and contraction, rotation, buckling, ISO fire resistance, and structural stability were experimentally quantified. It has been observed that the contraction rate of axial deformation was affected mostly by the duration of heating time and buckling of reinforcement or member by the magnitude of axial load, duration of heating time, cover thickness and eccentricity in order. Based on the experimental observations, ISO fire resistance criteria were qualiatively criticized.
Keywords
experiments; reinforced concretes columns; heating time; ISO fire resistance;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Lin, T. D., Zwiers, R I., Burg, R. G., Lie, T. T.,and McGrath, R J., 'Fire Resistance of Reinforced Concrete Columns,' PCA Research and Development Bulletin RD101B, Portland Cement Association, 1992, pp.1-26
2 Lie, T. T. and Allen, D. E., 'Fire Resistance of Reinforced Concrete Colunms,' Division of Building Research National Research CounciI of Canada Ottawa, Canada, pp.245-254
3 Lie, T. T., Lin, T. D., Allen, D. E., and Abrams, M.S., 'Fire Resistance of Reinforced ConcreteColumns,' National Research Council CanadaDivision of Building Research, Canada, 1984, pp.1-20
4 Lie, T. T., 'New facility to determine fire resistanceof columns,' Fire Research Section, Division ofBuilding Research, National Research Council ofCanada, Ottawa, Ont, KIA 0R6, 1980, pp.551-558
5 Yamazaki, N., Yamazaki, M., Mochida, T., Mutoh,A., Miyashita, T., Ueda, M., Hasegawa, T.,Sugiyama, T., Hirakawa, K., Kikuchi, R., Hiramoto,M., Saito, K., 'Structural Behavior of Reinforced Concrete Structures at High Temperatures," NuclearEngineering and Design, Vol.156, 1995, pp.121-138
6 Franssen, J. M., 'Failure Temperature of a SystemComprising a Restrained Column Submitted toFire,' Fire Safety Journal, Vol.34, 2000, pp.191-207
7 Harmathy,T. Z., 'Fire Safety Design and Concrete,'Longman Scientific & Technical. 1993. pp.1-412
8 강병희, 오창희, '고온수열콘크리트의 성상에 관한 실험적 연구(2)/물리적 성질을 중심으로,' 대한건축학회 논문집, 5권(통권24호), 1989, pp.285-292
9 조재열, '고온에 노출된 콘크리트의 잔류압축강도특성에 관한 연구', 공학석사학위논문, 서울대학교대학원,1995, pp.34-42
10 ACI Committee 216R, 'Guide for Determining the Fire Endurance of Concrete Elements,' ACI216R-89, American Concrete Institute, Detroit MI,1989, pp. 1-26
11 Sidibe, K, Duprat, F., Pinglot, M, And Bourret, B.,'Fire Safety of Reinforced Concrete Columns,' ACIStructural Journal, 2000, pp.642-647
12 콘크리트 구조설계기준, 건설교통부, 1999. pp.70
13 KSF2257-1, '건축구조부재의 내화시험방법 - 일반요구사항,' 한국표준협회, 산업표준심의회심의. 1999년11월30일 제정. pp.1-17
14 KSF2257-7, '건축구조부재의 내화시험방법 - 기둥의성능조건', 한국표준협회, 산업표준심의회 심의. 1999년11월30일 제정. pp.1-7
15 Draft International Standard ISO/FDIS 834-1: 1999(E), pp.12-26
16 강병희, 오창희, 김화중, 김인수, '가열시의 콘크리트 내부온도분포 산정에 관한 실험적 연구', 대한건축학회 논문집, 7권, 6호, 1991, pp.237-245
17 강석원, 홍성걸, 신영수, '고온에서의 비선형 변형도를 고려한 콘크리트 구조물에서의 열응력 분포' 한국콘크리트학회 가을학술발표회 논문집, 12권 2호, 통권 제23호, 2000, pp.1145-1150
18 허은진, '철근콘크리트 휨부재의 내화성능에 관한 실험적 연구', 공학석사학위논문, 부산대학교대학원, 2001,pp.1-100
19 강석원, '고온에 노출된 철근 콘크리트 기둥 및 보의 수치 해석', 공학박사학위논문,서울대학교대학원, 2001,pp.1-151
20 '내화구조의 인정 및 관리기준', 건축물의 피난·방화구조등의 기준에 관한 규칙 제 3조, 건교부고시 제2000-93호, 2000. pp.-~2