• Title/Summary/Keyword: 'room'

Search Result 15,343, Processing Time 0.04 seconds

The Study on the Interior Spatial Characteristics of Korean Single-Family Houses which were Designed by Architect (우리나라 단독주택 내부의 평면적 구성방식과 입체적 구성방식에 관한 연구)

  • Lee You-Mi
    • Journal of the Korean housing association
    • /
    • v.16 no.1
    • /
    • pp.89-95
    • /
    • 2005
  • This study aims to analyze interior spatial characteristics of Korean single-family house which were designed by architects. For that purpose, plans, pictures and data of Korean single-family 113 houses which appeared in architectural publications from 1998.7 to 2002.6. were collected. The results of this study are the followings; 1) the ratio of southern-facing is higher in living room and master bedroom than in dining room and kitchen; 2) spatial elements of master bedroom are bedroom, bathroom and dressroom, those of dining room and kitchen are dining room, kitchen and multipurpose room and those of family bathroom are bathroom and restroom; 3) the living room does not located in the center of the plan; 4) the ratio of exterior door is higher in kitchen and master bedroom than in dinning room and living room; 5) stairs located in hall, corridor, livingroom etc., 6) there are void spaces in about half of houses which were collected.

New Learning Hybrid Model for Room Impulse Response Functions (새로운 학습 하이브리드 실내 충격 응답 모델)

  • Shin, Min-Cheol;Wang, Se-Myung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.23-27
    • /
    • 2007
  • Many trials have been used to model room impulse responses, all attempting to provide efficient representations of room acoustics. The traditional model designs for room impulse response seem to fail in accuracy, controllability, or computational efficiency. In time domain, a room impulse response is generally considered as the combination of three parts having different acoustic characteristics, initial time delay, early reflection, and late reverberation. This paper introduces new learning hybrid model for the room impulse response. In this proposed model, those three parts are modeled using different models with learning algorithms that determine the length or boundary of each model in the hybrid model. By the simulation with measured room impulse responses, it was examined that the performance of proposed model shows the best efficiency in views of both the parameter numbers and modeling error.

  • PDF

New Learning Hybrid Model for Room Impulse Response Functions (새로운 학습 하이브리드 실내 충격 응답 모델)

  • Shin, Min-Cheol;Wang, Se-Myung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.3
    • /
    • pp.361-367
    • /
    • 2008
  • Many trials have been used to model room impulse responses, all attempting to provide efficient representations of room acoustics. The traditional model designs for room impulse response seem to fail in accuracy, controllability, or computational efficiency. In the time domain, room impulse responses are generally considered as combination of the three Parts having different acoustic characteristics, initial time delay, early reflection, and late reverberation. This paper introduces new learning hybrid model for room impulse responses. In this proposed model, those three parts are modeled using different models with learning algorithms that determine the boundary of each model in the hybrid model. By the simulation with measured room impulse responses, the performance of proposed model shows the best efficiency in views of computational burden and modeling error.

A Study on Spatial Composition of the Reusing Unit in High-rise Mixed-Use Condominium (초고층 주상복합 아파트 단위평면의 공간구성에 관한 조사연구)

  • 소윤경;하미경
    • Journal of the Korean housing association
    • /
    • v.13 no.3
    • /
    • pp.45-53
    • /
    • 2002
  • The purpose of this study is to examine the characteristics of unit plans in the high-rise mixed-use condominium and to provide the data fur architectural planning and design. The tools of statistical analysis are frequency, percentage, mean, cross-tab, and correlation. The results of this study are as fellows; The most frequently found shape of unit is a deformed polygon. The common rooms in housing units are dressing room, powder room, offset-kitchen, family room, passage, hallway, and foyer. The specially prepared spaces are wash room, home bar, independent porch, and garden. As to room size and area ratio in a dwelling unit, those of living room are biggest and highest irrespective of unit size. As the floor area of unit increases, does the size of each room and space but the area ratio of each room decreases. This research is made to develop an Apartment Information System. This integrated information system is to be designed to provide residents of high-rise mixed-use condominiums with convenient, economical, and safe life.

Users' Behavior Study for the Planning of One-room System Houses (원룸시스템 주택 계획을 위한 거주자 행태연구)

  • 조성희;권미지
    • Journal of the Korean housing association
    • /
    • v.14 no.3
    • /
    • pp.165-174
    • /
    • 2003
  • The demand for one-room system house as a new type of house will increase gradually, and residents also tend to be diversified. However, a method of planning of planning of one-room system house was limited and unified. Current floor plans of the one-room don't utilize a benefit of open plan in small areas. The purpose of this study is to propose several guidelines for the planning of one-room system houses that correspond to residents' needs in order to facilitate the benefit of open plan such as efficiency and multi-purpose use in small area. For this, a field survey was carried out as case studies, with individual interviews, questionnaires, and actual survey including taking pictures. Subjects were 50 residents who living in one-room system houses in Busan. Space usage behavior of residents, residential satisfactions, and preference attitudes on the attached service facilities were analyzed. The results were synthesized to suggest several guidelines for planning of one-room system house.

Distribution of Pollutant on the Indoor Air of Passenger Car (철도차량 객차내 오염물질의 분포경향에 관한 전산해석)

  • So, Jin-Sub;Chun, Chul-Kyun;Park, Chan-Su;Choi, Ju-Seok
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.2
    • /
    • pp.7-16
    • /
    • 2003
  • The transfer of air pollutants between passenger room and service room in train are investigated by the computational analysis. The effects of service room temperature, inlet velocity, initial concentration and heating are studied. The flow induced by the difference of density between two rooms is found to take the major role in transfer of polluted air. Low temperature of service room enhances the polluted air flow into passenger room along the floor. Exhaust fan above the door between two rooms is not effective for this case. Strong inlet flow is found to suppress polluted air flow from service room. The heating of passenger room can promote air pollution.

  • PDF

Research about correlation of slab vibration mode and heavy-weight floor impact sound (슬래브의 동특성과 중량충격음의 상관관계에 관한 연구)

  • Chung, J.Y.;Lee, S.W.;Im, J.B.;Jeong, G.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.839-843
    • /
    • 2008
  • Receiving room's floor impact sound level is been influenced to various factor of slab thickness, room size, structure etc. This study examined the noise of upper part slab and room mode in receiving room to be importance factor that influence in receiving room level among this factors. According to this study, vibration mode in slab and room mode are concentrated on frequency that is high level relatively. This causes bad effect in floor impact sound level. Therefore, method to reduce floor impact sound level is to change vibration mode using slab upper part's resilient material or reduce room mode in receiving room.

  • PDF

Work Experiences of Delivery Room Nurses: A Phenomenological Study (분만실 간호사의 근무 경험에 관한 현상학적 연구)

  • Lee, Yunjung
    • Women's Health Nursing
    • /
    • v.23 no.2
    • /
    • pp.78-88
    • /
    • 2017
  • Purpose: This study aimed to understand meaning and essentials in work experiences of delivery room nurses. Methods: A phenomenological perspective was used for this qualitative research. Ten delivery room nurse with more than 3 years of work experience participated in this study. Data were collected through individual in-depth interviews with the nurses, between December 2012 and April 2013. Data were analyzed using Colaizzi's method. Results: Nine theme clusters and four categories emerged from the data as follows: 1) factors influencing career decision-making, 2) gap between reality and expectations, 3) difficulties with working in the delivery room, and 4) motivation to work in the delivery room. Conclusion: Based on the results of this study, strategies to improve working environment of the delivery room nurses are necessary. Also, better policy are required to firmly establish the role of the delivery room nurses' role as recognized professionals.

Cooling Performance Measurement of a 3 Room Type Inverter Heat Pump System (3실형 인버터 열펌프 시스템의 냉방성능 측정)

  • 정광진;최영돈;장효환;송재복;박윤철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.431-439
    • /
    • 2001
  • Recently, multi-room type heat pump system has aroused much attention, because it can achieve much reduction of installation cost and space as well as energy saving in companion with the single room type heat pump system. In the present study, performance characteristics of a 3 room type inverter driven heat pump system, which is widely spread in Japanese market, are measured.. In the single room operation, performances of a heat pump system such s the difference of compressor outlet and inlet pressures and the mass flowrate may increase with the increase of cooling capacity so that COP of the system decrease with the increase of cooling capacity. However, in the 2 room operation, mass flowrate and COP of the total system increase markedly as compared with the single room operation.

  • PDF

Basic Experimental Study on Room Lighting Effects using Artificial Light Source (인공 광원을 이용한 실내 조명 효과에 대한 기초 실험 연구)

  • Kim, Jeongbae
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.1
    • /
    • pp.29-33
    • /
    • 2011
  • This study is performed to investigate the effect of the artificial light for room lightening. To do that, the experiments were done using the black room with 1m3 and performed to show the effect of the length between the room and light source and light intensities as LUX. The LUX of 18 sites in the room was measured using LUX meter. The length between the room and the light source was chosen as 500mm, 1000mm, and 1500mm and the light intensities was 3 levels. The results were shown the distinct difference between the part directly projected through the light path and non-directly projected. So, the light delivery path have to be modified for next step research. The results were very sensitive for the part directly projected through the light path. This study showed the basic results for room lightening using light source to simulate the solar lightening and was worth in a strict sense as fundamental study.

  • PDF