• 제목/요약/키워드: $^{99}Tc$ analysis

검색결과 211건 처리시간 0.145초

HDPy 및 HDTMA로 개질된 벤토나이트에 대한 Re(VII)의 흡착반응 분석 (Investigation of Sorption Reaction of Re(VII) onto HDPy- and HDTMA-modified Bentonite)

  • 최준명;하준혁;최란영;이준엽
    • 방사선산업학회지
    • /
    • 제18권3호
    • /
    • pp.167-171
    • /
    • 2024
  • Technetium-99 (99Tc) is recognized as a critical concern in the disposal of spent nuclear fuel due to its long half-life and remarkable stability, existing predominantly as TcO4- in the natural environment. The anionic form of technetium is highly soluble and mobile, posing significant environmental risks from the viewpoint of nuclear waste management. Thus, developing efficient and cost-effective sorbents for aqueous Tc(VII) is essential for mitigating relevant contamination. In the present work, the adsorption characteristics of Re(VII), a chemical analog of Tc(VII), were investigated using the clay mineral bentonite, modified with two different organic cations: hexadecylpyridinium (HDPy) and hexadecyltrimethylammonium (HDTMA). Sorption experiments were conducted at a liquid-to-solid ratio of 1 g/L with Re(VII) solutions prepared at concentrations from 10-4 mol/L to 10-6 mol/L. The sorption ratio and distribution coefficients were determined with samples collected at reaction times of 10, 50, 100, and 500 minutes after 0.45 ㎛ syringe filtration. In parallel, the modified bentonite samples were further analyzed using the X-ray diffraction (XRD) method to understand the adsorption mechanism of Re(VII) onto the target minerals. According to the quantification analysis results, a rapid equilibrium reaction of aqueous Re(VII) for all modified bentonite samples was identified. Moreover, near-complete adsorption of Re(VII) was observed when the bentonite was modified at 200-400% of its cation exchange capacity (CEC) for both organic cations. For cases of lower modification, the HDTMA-modified bentonite showed relatively higher adsorption efficiency compared with the one modified with HDPy. This result was inferred to be due to the difference in inter-layer spacing based on the characteristics of the organic cations. It is expected that the results obtained through this study will serve as a preliminary case for the synthesis of adsorbents for the retardation of highly mobile anionic radionuclides, such as I and Tc, in the natural environment.

Hydroxyapatite 안구보충물삽입술 후 골신티그라피를 이용한 섬유혈관증식 평가: 평면영상과 SPECT 영상에서의 비교 (Assessment of Vascularization within Hydroxyapatite Ocular Implant by Bone Scintigraphy: Comparative Analysis of Planar and SPECT Imaging)

  • 임석태;손명희;박순아
    • 대한핵의학회지
    • /
    • 제33권6호
    • /
    • pp.475-483
    • /
    • 1999
  • 목적: 안구보충물로 사용된 hydroxyapatite 내로의 섬유혈관증식은 이물질 반응으로 인한 염증의 동반없이 의안의 운동성을 유지시키기 위한 운동성 나사못을 삽입하는데 중요한 역할을 한다. 안구보충물 삽입술 후에 섬유혈관증식의 정도를 알아보는데 Tc-99m MDP를 이용한 평면영상과 단면영상에서 정성적 평가와 정량적 평가의 비교분석을 함으로서 완전한 섬유혈관증식을 예측하는데 단면영상의 유용성을 알아보고자 하였다. 대상 및 방법: 안구 제거술후 hydroxyapatite를 이용하여 안구보충술을 시행받고 $197{\pm}81$일 후에 골신티그라피를 시행받은 17명의 환자(남:녀=12:5, 연령; $50.4{\pm}17.5$세)의 18예를 대상으로 하였다. 골신티그라피는 Tc-99m MDP 740 MBq를 정맥주사 후 4시간 경과뒤에 이중헤드 감마카메라(ECAM, Siemens, Germany)로 안면부 평면영상을 얻은 후 이어서 단면영상을 얻었다. 평면영상과 단면영상에서의 안구보충물의 방사능 섭취가 비교(nasal bridge)보다 약한 경우를 grade 1, 비슷한 경우를 grade 2, 강한 경우를 grade 3로 평가하였고, 정상안구에 대한 안구보충물의 섭취비를 정량적으로 구하여 운동성 나사못 삽입술 후 시행된 세극등 검사에서 염증반응의 동반 없이 완전한 섬유혈관증식을 보인 환자 군과 염증 반응의 동반과 함께 불완전한 섬유혈관증식을 보인 환자 군으로 나누어 비교 분석하였다. 결과: 평면영상에서 grade 1은 9예, grade 2가 1예, grade 3가 2예로 충분한 섬유혈관증식을 의미하는 grade 2와 3를 보인 경우가 9예 (50%) 이었으나 단면영상에서는 grade 1이 6예, grade 2가 4예, grade 3가 8예로 평면영상에 비하여 grade 2와 3를 보이는 경우가 12예(61%) 이었다. 정성적 평가에 의한 완전한 섬유혈관증식을 예측하는 데 있어서 평면영상은 예민도가 60% (9/15),특이도 100% (3/3), 양성예측률 100% (9/9), 음성예측률 33.3% (3/9), 정확도 66.7% (12/18) 이었고 단면영상은 예민도 80% (12/15), 특이도 100% (3/3), 양성예측률 100% (12/12), 음성예측률 50% (3/6), 정확도 83.3% (15/18) 이었다. 정량적으로 구한 안구보충물 내의 방사능 섭취비는 평면영상에서 grade 1은 $1.19{\pm}0.10$, grade 2는 $2.16{\pm}0.43$, grade 3는 $3.57{\pm}0.74$로 grade가 높을수록 정량적 섭취비가 유의하게 증가하였다(p<0.001). 단면영상에서 grade 1은 $3.06{\pm}1.22$, grade 2는 $3.71{\pm}0.83$, grade 3는 $12.49{\pm}4.31$로 grade가 높을수록 정량적 섭취비가 유의하게 증가하였다(p<0.001). 완전한 섬유혈관증식을 보인 환자 군과 불완전한 섬유혈관증식을 보인 환자군으로 나누어 정량적으로 측정한 방사능 섭취비를 비교시 평면영상에서는 $1.96{\pm}0.87$$1.17{\pm}0.08$로 유의한 차이를 보이지 않았으나 단면영상에서는 $8.44{\pm}5.45$$2.20{\pm}0.87$로 유의한 차이를 보였다 (p<0.05). 결론: 안구보충물 삽입 후 섬유혈관증식을 평가할 때 평면영상에 비하여 단면영상이 섬유혈관증식 정도를 평가하는데 보다 도움을 주었다.

  • PDF

도파민 운반체 영상의 임상이용을 위한 실제적 접근 (Practical Approach for the Clinical Use of Dopamine Transporter Imaging)

  • 김재승
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권6호
    • /
    • pp.425-434
    • /
    • 2008
  • Dopamine transporter imaging is useful in the diagnosis of Parkinson's disease and the most successful technique in the clinical use of neuroreceptor imaging. Recently, several radiopharmaceuticals including I-123 FP-CIT, Tc-99m TRODAT, and F-18 FP-CIT for dopamine transporter imaging have been approved for the routine clinical use in several European countries, Taiwan and Korea, respectively. This review summarized the practical issue for the routine clinical examination of dopamine transporter imaging.

정상 MRI 소견을 보이는 외상성 뇌손상 환자에서 국소뇌혈류량의 이상 (Reduced Regional Cerebral Blood Flow in Patients with Traumatic Brain Injury Who Had No Structural Abnormalities on Magnetic Resonance Imaging : A Quantitative Evaluation of Tc-99m-ECD SPECT Findings)

  • 김남희;정영기
    • 생물정신의학
    • /
    • 제9권2호
    • /
    • pp.152-158
    • /
    • 2002
  • Background & Purpose:Neuropsychological disorders after traumatic brain injury(TBI) are poorly correlated with structural lesions detected by structural neuroimaging techniques such as computed tomography(CT) scan or magnetic resonance imaging(MRI). It is well known that patients with TBI have cognitive and behavioral disorders even in the absence of structural lesions of the brain. This study investigated whether there are abnormalities of regional cerebral blood flow(rCBF) in TBI patients without structural abnormality on MRI, using technetium 99m ethyl cysteinate dimer(Tc-99m-ECD) single photon emission computed tomography(SPECT) scans. Materials and Methods:Twenty-eight TBI patients without structural abnormality on MRI(mild, n=13/moderate, n=9/severe, n=6) and fifteen normal controls were scanned by SPECT. A voxel-based analysis using statistical parametric mapping(SPM) was performed to compare the patients with the normal controls. Results:rCBF was reduced in the right uncus and the right lateral orbitofrontal gyrus in the TBI patients. However, no increase of rCBF was noted in the patients in comparison to the normal controls. Conclusions:These results suggest that the TBI patients, even in the absence of structural lesion of the brain, may have dysfunction of the brain, particularly of the orbitofrontal and anterior pole of the temporal cortex. They also suggest that SPECT can be a useful method to identify brain dysfunctions in combination with structural brain imaging and neuropsychological tests.

  • PDF

수종의 암세포에서 Verapamil이 Tc-99m MIBI와 Tetrofosmin의 섭취에 미치는 영향 (Effect of Verapamil on Cellular Uptake of Tc-99m MIBI and Tetrofosmin on Several Cancer Cells)

  • 김대현;유정아;서명랑;배진호;정신영;안병철;이규보;이재태
    • 대한핵의학회지
    • /
    • 제38권1호
    • /
    • pp.85-98
    • /
    • 2004
  • 목적: 다약제내성(MDR) 극복제 verapamil은 MDR이 발현된 암세포에서 Tc-99m MIBI(MIBI)와 tetrofosmin(TF)의 섭취를 증가시키는 것으로 알려져 있으나, 세포의 종류에 따라서는 MIBI와 TF의 섭취를 감소시킬 수 있다는 보고가 있다. 본 연구는 암세포의 종류에 따라 verpamile이 MIBI와 TF의 섭취에 미치는 영향이 세포에 따른 차이가 있는지를 알아보고, 이러한 차이가 세포독성이나 PKC효소의 발현에 따른 차이인가를 알아보았다. 방법: 백혈병세포 K562세포와 유방암세포 MCF7, 난소암세포 SK-OV-3 세포 및 MDR이 유발된 K562(Adr)세포를 배양하였다. 시험관에서 $1{\times}10^6\;cells/ml$ 농도의 single-cell suspension 상태로 분주하고 verapamil을 1, 10, 50, 100, $200{\mu}M$의 농도로 처리한 후 MIBI와 TF를 배양한 후, $37^{\circ}C$에서 1, 15, 30, 45, 60분 동안 반응시킨 후 pellet과 supernatant의 방사능 치를 감마계수기로 측정하여 투여한 방사능 치에 대한 세포내 섭취백분율로 표시하였다. Verapamil의 세포독성은 MTT assay로 측정하였고, 세포내의 PKC isotypes의 변화는 western blotting analysis로 평가하였다. 결과: 4종류의 세포 모두에서 MIBI와 TF의 섭취는 1, 15, 30, 45, 60분 배양 시간에 따라 증가하였다. verapamil을 처리시 다약제 내성이 유발된 K562(Adr)세포에서 $100{\mu}M$의 농도까지는 MIBI와 TF 섭취가 증가하였고, 최대 $10{\mu}M$에서 10배 증가하였다. 그러나 K562세포를 verapamil $1{\mu}M$로 처리하였을 때는 기저치와 유사하였으나, verapamil의 농도가 증가함에 따라 MIBI와 TF의 세포섭취는 모두 감소하였다. K562세포의 60분 MIBI 섭취율은 79%($10{\mu}M$), 47%($50{\mu}M$), 29%($100{\mu}M$), 1.5%($200{\mu}M$)로 verapamil의 용량이 증가함에 따라 감소하였으며, TF 섭취율도 84% ($10{\mu}M$), 60%($50{\mu}M$), 42%($100{\mu}M$), 2.7%($200{\mu}M$)로 감소하였다. MCF7, SK-OV-3세포에서는 verapamil $10{\mu}M$까지는 MIBI와 TF의 섭취가 기저치와 유사하거나 소량 증가하였으나 $50{\mu}M$이상의 용량에서는 감소하여 $100{\mu}M$에서는 각각 40%와 5%만 섭취되었다. MTT assay상 K562(Adr)세포에서는 verapamil $100{\mu}M$ 이상에서는 유의하게 낮았으나 다른 세포는 $200{\mu}M$까지에도 차이가 없었다. PKC 아형의 분석상 PKC $\varepsilon$이 K562(Adr)세포에서 많이 발현되었으나, K562와 K562(Adr)세포에서는 verapamil처리에 따른 PKC 아형의 변화는 없었다. 결론: Verapamil은 암세포의 종류에 따라 MIBI와 TF의 섭취를 감소시켰고, 고용량에는 MDR세포의 섭취도 감소시켰으며 이러한 현상은 세포독성 이나 PKC효소 아형과는 관련이 없었다. 그러므로 MDR의 진단시 verapamil을 처치에 따른 MIBI와 TF의 섭취 정도를 기준으로 하는 경우에는, verapamil의 농도와 세포의 종류에 따라 현저한 차이가 있을 수 있다는 점을 생각하여야 한다.

$^{99m}Tc$-DMSA 신장 검사에서 ROI 설정 방법에 따른 정량분석 차이에 관한 연구 (The difference of Quantitative Analysis According to the Method of Region of Interest Setting in $^{99m}Tc$-DMSA Renal Scan)

  • 이종훈;심동오
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.73-77
    • /
    • 2010
  • 핵의학 기술학의 발전은 많은 변화를 가져왔다. 하드웨어적인 발전이 많이 있었고 또한 소프트웨어의 발전도 핵의학 기술학 발전에 지대한 공을 세웠다. 소프트웨어의 발전으로 그 동안 수동으로 설정해야 했던 많은 ROI를 자동으로 설정할 수 있게 되었다. automated ROI가 manual ROI와 어떠한 정량분석의 차이를 가지고 있는지 알고자 한다. 분석은 3가지의 분석을 통해 결론을 도출하고자 하였다. 분석 1은 신장 automated ROI와 신장 manual ROI를 비교하였다. 분석 2는 threshold의 크기변화에 따른 차이를 조사하였다. 육안적 판단으로 신장의 외곽선보다 큰 threshold ROI(이하 A threshold), 외곽선과 일치하는 threshold ROI(이하 B threshold), 외곽선보다 작은 threshold ROI(이하 C threshold)를 설정하여 신장의 기능 값을 구하여 이를 비교 하였다. 분석 3은 automated background ROI를 세 가지 full, half, quarter로 분류하여 이에 따른 기능값의 차이를 분석하였다. 분석 1에서 신장 automated ROI와 신장 manual ROI간에 통계적으로 유의한 차이는 보이지 않았다. 그러나 분석 2에서 C threshold는 각 A threshold와 B threshold 간에 유의한 차이 (p<0.01)를 보였다. 분석 3은 분석 1을 통해 얻어진 결론을 토대로 시행되었다. 각 3가지 형태의 background에서 full background가 통계적으로 유의한 차이를 보였다(p<0.05). automated ROI가 manual ROI와 유의한 차이를 보지 않아 입증된 결과는 사용자의 편의와 객관성이 증대될 것으로 기대된다. 분석 2에서는 신장의 외곽선보다 작게 설정된 threshold는 신장의 외곽선보다 크게 설정된 threshold보다 큰 오차를 가질 수 있다는 것을 예상할 수 있다. 분석 3은 신장 주변의 간과 비장에 background가 증가되어 초래된 결과로 예상한다.

  • PDF

침샘의 기능평가에서 핵의학 검사의 표준화된 정보제공의 유용성 연구 (The Study on Usefulness of the Standardized Information of Nuclear Medicine Scan in Function Evaluation of the Salivary Glands)

  • 표성재;한재복;최남길
    • 한국방사선학회논문지
    • /
    • 제9권6호
    • /
    • pp.357-362
    • /
    • 2015
  • 테크네슘을 이용한 침샘검사의 시간-방사능 곡선에서 다양한 기능매개변수지표를 획득하여 환자 군과 건강한 정상군과의 비교를 통해 유용성을 알아보고자 하였다. 2014년 12월부터 2015년 2월까지 구강 건조증으로 침샘검사를 시행한 환자군 30명과 건강한 정상군 10명을 대상으로 하였다. 99mTc-과산화테크네슘 370 MBq을 정맥으로 주사 후 20분에 비타민C 파우더를 입안에 투여하여 10분 동안 촬영하였다. 분석방법은 귀밑샘과 턱밑샘의 관심영역을 정하여 시간-방사능 곡선을 그린 후 곡선의 각 위치에서 다양한 기능매개변수 지표를 획득하고, 구강 건조증 환자군와 정상군을 비교하였다. 비교 및 측정에 적용된 방법으로는 섭취율(uptake ratio, UR), 최대 방사능 시간(time at maximum counts, Tmax), 최소 방사능 시간(time at minimum counts, Tmin), 최대 축적율(maximum accumulation, MA), 축적 속도(accumulation velocity), 최대 배출율(maximum secretion, MS), 최대 자극 배출율(maximum stimulation secretion, MSS), 배출속도(secretion velocity, SV)를 사용하였다. 환자군과 정상군간의 기능매개변수지표 비교에서 환자군의 최소 방사능 시간(Tmin)을 제외한 모든 지표에서 건강한 정상군이 환자군에 비하여 유의한 차이를 보였고, 시간에 따른 변화량에서도 정상군이 환자군에 비하여 유의한 차이를 보였다. 결론적으로 침샘검사에서 다양한 기능매개변수지표를 이용한 정량분석은 구강 건조증 환자의 침샘 기능을 객관적이고 표준화된 정보로 평가하는데 유용할 것으로 사료된다.

국내 원자력발전소 잡고체폐기물의 예측방사능량과 실측방사능량의 비교분석 (Comparison of Radionuclide Inventory Between Predicted and Measured Activity of Dry Active Waste From Korea Nuclear Power Plant)

  • 정강일;김진형;정노겸;박진백
    • 방사성폐기물학회지
    • /
    • 제15권3호
    • /
    • pp.281-299
    • /
    • 2017
  • 핵종재고량 관리는 처분시설의 안전한 관리를 위해서는 필수적이다. 본 논문에서는 원자력발전소의 잡고체폐기물에 대하여 기존 발생된 폐기물 자료를 반영한 예측방사능량과 실제 처분시설을 운영하면서 인수되어 처분검사까지 완료된 실제방사능량을 비교분석하였다. 극저준위방사성폐기물에서는 $^{137}CS$, $^{90}Sr$, $^{99}Tc$ 그리고 $^{129}I$ 핵종이 예측방사능량보다 실제방사능량이 높게 평가되었으며, 저준위방사성폐기물에서는 모든 핵종에서 예측방사능량이 실제 방사능량보다 높게 평가되었다. 또한 척도인자에 의한 예측방사능량의 민감도 분석을 통해 준위별 수량 및 총방사능량의 변화추이를 분석하였다. 향후 중저준위방사성폐기물 처분시설의 안전한 운영과 Safety Case 구축을 위한 기초자료로 활용될 것으로 판단된다.