• 제목/요약/키워드: zero-energy

검색결과 1,184건 처리시간 0.024초

Enhance photoelectric efficiency of PV by optical-thermal management of nanofilm reflector

  • Liang, Huaxu;Wang, Baisheng;Su, Ronghua;Zhang, Ao;Wang, Fuqiang;Shuai, Yong
    • Advances in nano research
    • /
    • 제13권5호
    • /
    • pp.475-485
    • /
    • 2022
  • Crystalline silicon photovoltaic cells have advantages of zero pollution, large scale and high reliability. A major challenge is that sunlight wavelength with photon energy lower than semiconductor band gap is converted into heat and increase its temperature and reduce its conversion efficiency. Traditional cooling PV method is using water flowing below the modules to cool down PV temperature. In this paper, the idea is proposed to reduce the temperature of the module and improve the energy conversion efficiency of the module through the modulation of the solar spectrum. A spectrally selective nanofilm reflector located directly on the surface of PV is designed, which can reflect sunlight wavelength with low photon energy, and even enhance absorption of sunlight wavelength with high photon energy. The results indicate that nanofilm reflector can reduce spectral reflectivity integral from 9.0% to 6.93% in 400~1100 nm wavelength range, and improve spectral reflectivity integral from 23.1% to 78.34% in long wavelength range. The nanofilm reflector can reduce temperature of PV by 4.51℃ and relatively improved energy conversion efficiency of PV by 1.25% when solar irradiance is 1000 W/m2. Furthermore, the nanofilm reflector is insensitive in sunlight's angle and polarization state, and be suitable for high irradiance environment.

연료전지발전용 부스터의 출력전압제어 연구 (Control of Booster Output Voltage in Fuel Cell Power Plant)

  • 한수빈;정봉만;신동열;최수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1038-1040
    • /
    • 1992
  • Booster is used widely as one of the step-up DC/DC power converter in power conversion process for fuel cell power plant which have the electrical characteristic of the high current density and low cell voltage. In view of control system, booster can be unstable when it is operated in broad operation range because the transfer function of booster has zero in right half plane of s-domain. So for reliable operation, controller must make the system stable in whole working range. In this paper, the two control method such as digital PID control and fuzzy control is studied for booster output voltage regulation in fuel cell plant. The design procedure of PID control and fuzzy control is described. And the experiment of designed controller action is performed in various operation points for controller performance test.

  • PDF

면외하중을 받는 상이한 직교 이방성 평면내의 평행균열 (Parallel Crack in Bonded Dissimilar Orthotropic Planes Under Out-of-Plane Loading)

  • 최성렬;권용수;채영석
    • 대한기계학회논문집
    • /
    • 제19권1호
    • /
    • pp.170-180
    • /
    • 1995
  • A parallel crack in bonded dissimilar orthotropic planes under out-of-plane loading is analyzed. The problem is formulated by Fourier integral transforms, and reduced to a pair of dual integral equations. By solving the integral equations, the asymptotic stress and displacement fields near the crack tip are determined in closed form, from which the stress intensity factor and energy release rate are obtained. Discontinuity in the stress intensity factor as the distance ratio h/a of the parallel crack approaches zero is found, while the energy releas rate is shown to be continuous at h/a = 0. This information can immediately be used to generate the stress intensity factor for the parallel crack near the interface. By employing "the maximum energy release rate criterion", it could be shown in the case of no existing crack initially that the parallel crack is formed far from the interface for the more compliant material, while it is formed close to the interface for the stiffer material. material.

New Energy Recovery Concept for AC PDP Sustaining Driver Using Current Injection Method (CIM)

  • Lee, Jun-Young;Kim, Jin-Sung;So, Myeong-Seop;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • 제2권3호
    • /
    • pp.189-198
    • /
    • 2002
  • New concept of energy recovery for plasma display panel (PDP) Is proposed. Different from conventional LC resonant sustaining drivers, the current built up before inverting the polarity of the panel electrodes is utilized to change the panel Polarity together with energy Previously charged in Panel capacitance. This operation Provides zero -voltage-switching of switches and reduction of EMI by rejecting the surge current when the sustain switches are turned on. The build-up current helps to reduce transition time of panel polarity and may produce more stable light waveforms. This method shows a desirable characteristic that the circuit loss is similar to that of series resonant type energy recovery circuit which is very effective method.

변곡점 및 단구간 에너지평가에 의한 음성의 천이구간 특징분석 (Analysis of Transient Features in Speech Signal by Estimating the Short-term Energy and Inflection points)

  • 최일홍;장승관;차태호;최웅세;김창석
    • 음성과학
    • /
    • 제3권
    • /
    • pp.156-166
    • /
    • 1998
  • In this paper, I would like to propose a dividing method by estimating the inflection points and the average magnitude energy in speech signals. The method proposed in this paper gave not only a satisfactory solution for the problems on dividing method by zero-crossing rate, but could estimate the feature of the transient period after dividing the starting point and transient period in speech signals before steady state. In the results of the experiment carried out with monosyllabic speech, it was found that even through speech samples indicated in D.C. level, the staring and ending point of the speech signals were exactly divided by the method. In addition to the results, I could compare with the features, such as the length of transient period, the short term energy, the frequency characteristics, in each speech signal.

  • PDF

Uranium(VI) Phosphate Precipitate Formation in a Carbonate Solution

  • Im, Hee-Jung;Park, Kyoung-Kyun;Park, Yeong-Jae;Kim, Won-Ho
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 2005년도 춘계학술발표회
    • /
    • pp.311-312
    • /
    • 2005
  • The precipitation of U(VI) in the presence of phosphate and carbonate was investigated in the pH range of 4 to 13 and the following was obtained as a result of this experimental condition. U(VI) precipitates as a $NaUO_{2}PO_{4}$ at pH<9 but as mixtures of phosphate, hydroxides and/or carbonate at pH>9. The portion of the phosphate in the precipitate decreases almost linearly to near zero with an increasing pH in the range of 9 to 13. The U(VI) phosphate is dissolved by the carbonate complex formation at pH<10.5. The ternary complex of a carbonate and phosphate is not found.

  • PDF

이족보행로봇의 보행을 위한 에너지 최적화 (Energy Optimization for The Walking of Biped Robot)

  • 김종태;최상호;임선호;김진걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2339-2341
    • /
    • 1998
  • This paper is concerned with an energy optimization for the walking of IWR biped robot. The movement of balancing joints are determined by ZMP(Zero Moment Point) and dynamic properties caused by motion of a swing leg. Therefore, ZMP positions have an important role in walking and guarnateeing the stability of a robot. A genetic algorithm is utilized for solving this problem and finding ZMP with a minimum energy at each sampling time during the walk. In this study, we performed an energy optimization with desired ZMP trajectories and motion of balancing joints.

  • PDF

고기밀 고단열 주택의 기밀성능에 관한 실험적 연구 (Experimental Study on Airtightness Performance of the House with High Levels of Insulation and Airtight Construction)

  • 신우철;윤종호;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.61-67
    • /
    • 2005
  • The purpose of this study is to evaluate the air tightness of Zero Energy Solar House(ZeSH) and to propose the construction improvement of junctions and penetrations where air infiltration was identified. Air leakage rate were measured by means of blower door test in accordance with ASTM E779-87. The results showed that ZeSH has an excellent airtightness with ACH50/20 (air change per hour at a pressure difference of 50 Pa between inside outside) of 0.34hr-1 and leakage class E by normalized leakage area of ASHRAE.

ORBITAL ENERGY DURING THE EVOLUTION OF THE ORBITAL DYNAMICS OF ASTEROID 4179 TOUTATIS

  • SOEGIARTINI, ENDANG
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.69-71
    • /
    • 2015
  • In our previous work, we investigated the orbital dynamics of Asteroid 1934 CT (or 1989 AC or 4179 Toutatis) from epoch 2012-Jul-24 (JDE2456132.5) using the Mercury program package. Asteroid 4179 Toutatis has an Earth and Mars crossing orbit with semimajor axis a = 2.5292 AU and eccentricity e = 0.6294, and therefore the perihelion distance is q = 0.9373 AU and the aphelion distance is Q = 4.1211 AU. After more than 300,000 years, asteroid 4179 Toutatis will escape from the Solar System, but during this time, it will have close-encounters with other planets from Venus to Uranus. As a continuation of this project, we investigated its energy changes in each close encounter. We also determine the energy of this asteroid when it escapes from the Solar System. The result is that during its orbital evolution, the energy of this asteroid changes and gives us negative, zero and positive values.

Integrated DC-DC Converter Based Energy Recovery Sustainer Circuit for AC-PDP

  • Park, Jae-Sung;Shin, Yong-Saeng;Hong, Sung-Soo;Han, Sang-Kyoo;Roh, Chung-Wook
    • Journal of Power Electronics
    • /
    • 제12권6호
    • /
    • pp.878-885
    • /
    • 2012
  • A new sustainer with primary-side integration of DC/DC converters and energy recovery(SPIDER) circuits is proposed. The proposed circuit operates as a DC-DC converter during address period and energy recovery circuit during sustain period. Therefore, the conventional three electronic circuits composed of the power supply, X-driver, and Y-driver can be reduced to one circuit. As a result, it has desirable advantages such as a simple structure, less mass, fewer devices and cost reduction. Moreover, since the Zero Voltage Switching (ZVS) of all power switches can be guaranteed, a switching loss can be considerably decreased. To confirm the operation, validity, and features of the proposed circuit, experimental results from a prototype for 42-inch PDP are presented.