• Title/Summary/Keyword: zero-energy

Search Result 1,183, Processing Time 0.025 seconds

Study on Thermodynamic Performance of Electrochemical Hydrogen Compressor (전기화학적 수소 압축기의 열역학적 성능에 관한 연구)

  • TEAHEON KIM;DONGYUN KIM;DONGKEUN LEE;YOUNGSANG KIM;KOOKYOUNG AHN;YONGGYUN BAE;JINYOUNG PARK;YOUNG KIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.2
    • /
    • pp.141-148
    • /
    • 2023
  • The thermodynamic performance of the electrochemical hydrogen compressor was analyzed to perform a comparative analysis with the performance of the mechanical compressor. The performance was analyzed through the applied current and the measured voltage value. The test results showed that the efficiency of the electrochemical hydrogen compressor was high in the low current density range. In addition, it was confirmed that the amount of increasing compress work of the electrochemical hydrogen compressor is smaller than that of the mechanical compressor. Therefore, it is expected to have higher efficiency than mechanical compression when compressed with a sufficiently high-pressure range.

Energy Recovery Circuit for the Plasma Display Panel Sustainer

  • Cho, B.H.;Kim, W.S.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.625-630
    • /
    • 2005
  • In this paper, several energy recovery circuits (ERC) for the plasma display panel (PDP) are reviewed and classified in a manner of operation characteristics. A typical ERC using the Regenerative Transformer (RT) is introduced and compared with conventional ones. RT-ERC can achieve zero-voltage-switching (ZVS) for main full-bridge switches and zero-current-switching (ZCS) for the resonant switches and diodes. The charging/discharging energy of panel capacitance is efficiently recovered with the RT and without a sub-circuit. The presented circuit is verified with simulation and experimental results.

  • PDF

A DVR Control for Compensating Unbalanced Voltage Dips of a DFIG System using Zero Sequence Components

  • Thinh, Quach Ngoc;Ko, Ji-Han;Kim, Dong-Wan;Kim, Eel-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.62-68
    • /
    • 2013
  • The dynamic voltage restorer (DVR) is an effective protection device for wind turbine generators based on doubly-fed induction generator (DFIG) that is operated under unbalanced voltage dip conditions. The compensating voltages of the DVR depend on the voltage dips and on the influence of the zero sequence component. The zero sequence component results in high insulation costs and asymmetry in terminal voltages. This paper proposes the use of a proportional-resonant controller in stationary reference frames for controlling zero sequence components in the DVR to protect the DFIG during unbalanced voltage dips. To enhance the proposed control method, a comparison is carried out between two cases: with and without using the control of a zero sequence component. Simulation results are presented to verify the effectiveness of the proposed control method by using the Psim simulation program.

On spectral and statistical characteristics of sea waves by the typhoons (태풍에 의한 파랑의 스펙트럼 및 통계적 특성)

  • Shim, Jae-Seol;Oh, Byung-Chul;Kim, Sang-Ik
    • Water for future
    • /
    • v.22 no.4
    • /
    • pp.441-451
    • /
    • 1989
  • Using the wave data by typhoons LEE, VERA, THELMA which gave great damages in the Korean penisula, the significant waves based on zero-up & down crossing and Tucker-Draper method are compared with those from the wave energy spectrum. And the histograms of individual waves obtained from zero-up crossing method are presented and compared with the Rayleigh, Weibull, Gluhovski, Ibrageemov and Goda distributions, and also the Chi-square goodness of fit test is applied to each theoretical distributions. It is shown that the significant wave heights by zero-up crossing method are very well agreed to those by energy spectrum method. The wave heights are found to well follow the Rayleigh and Goda distributions by the Chi-square test.

  • PDF

Energy-Efficient Reference Walking Trajectory Generation Using Allowable ZMP (Zero Moment Point) Region for Biped Robots (2족 보행 로봇을 위한 허용 ZMP (Zero Moment Point) 영역의 활용을 통한 에너지 효율적인 기준 보행 궤적 생성)

  • Shin, Hyeok-Ki;Kim, Byung-Kook
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.10
    • /
    • pp.1029-1036
    • /
    • 2011
  • An energy-efficient reference walking trajectory generation algorithm is suggested utilizing allowable ZMP (Zero-Moment-Point) region, which maxmizes the energy efficiency for cyclic gaits, based on three-dimensional LIPM (Linear Inverted Pendulum Model) for biped robots. As observed in natural human walking, variable ZMP manipulation is suggested, in which ZMP moves within the allowable region to reduce the joint stress (i.e., rapid acceleration and deceleration of body), and hence to reduce the consumed energy. In addition, opimization of footstep planning is conducted to decide the optimal step-length and body height for a given forward mean velocity to minimize a suitable energy performance - amount of energy required to carry a unit weight a unit distance. In this planning, in order to ensure physically realizable walking trajectory, we also considered geometrical constraints, ZMP stability condition, friction constraint, and yawing moment constraint. Simulations are performed with a 12-DOF 3D biped robot model to verify the effectiveness of the proposed method.

Energy Transition Trend in Residential Complexes for Carbon Neutrality (탄소중립을 위한 주거단지에서의 에너지 전환 동향)

  • Lee, Taegoo;Han, Younghae
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.26 no.2
    • /
    • pp.1-8
    • /
    • 2024
  • Carbon neutrality refers to a state in which there is no global increase in CO2 emissions due to human activities. In Korea, for carbon neutrality, green remodeling of existing buildings and customized support tasks for zero energy in new buildings are presented. Germany is showing fundamental changes in energy supply, such as applying renewable energy and higher energy efficiency from nuclear and fossil fuels, which were the existing energy sources. In this study, how Germany establishes policies for carbon neutrality at each state level and the cases applied to increase the energy efficiency of the actually applied residential complexes are analyzed based on this. As a result of the case complex analysis, it was found that the construction direction was being promoted as a zero-energy complex or a carbon-neutral complex by gradually reducing the energy demand in buildings and supplying additional energy with new and renewable energy in the low-energy building distribution in the 1990s. In Germany's ecological complex, energy standards have been strengthened from low-energy architecture to plus-energy architecture over time, and annual heating energy consumption standards and heat transmittance rates for each structure have been achieved at a higher level. The results of this analysis will serve as basic data and derivation of applicable items when planning residential complex development and remodeling of existing buildings for the domestic carbon-neutral goal in the future.

New High Efficiency Zero-Voltage-Switching AC-DC Boost Converter Using Coupled Inductor and Energy Recovery Circuit (결합 인덕터 및 에너지 회생 회로를 사용한 새로운 고 효율 ZVS AC-DC 승압 컨버터)

  • Park, Gyeong-Su;Kim, Yun-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.10
    • /
    • pp.501-507
    • /
    • 2001
  • In this paper, new high-efficiency zero voltage switching (ZVS) AC-DC boost converter is proposed to achieve power factor correction by simplifing energy recovery circuit. A lot of high power factor correction circuits have been proposed and applied to increase input power factor and efficiency. Most of these circuits may obtain unity power factor and achieve sinusoidal current waveform with zero voltage or/and zero current switching. However, it is difficult for them to obtain low cost, small size, low weight, and low noise. The topology proposed to improve these problems can compact the devices in circuit and can achieve high efficiency ZVS AC-DC boost converter. Simulation and experimental results show that this topology is capable of obtaining high power factor and increasing the efficiency of the system.

  • PDF

Improvement of Finite Element for Mindlin Plate Bending (Mindlin 평판 유한요소의 개선)

  • 김선훈;최창근
    • Computational Structural Engineering
    • /
    • v.1 no.2
    • /
    • pp.83-90
    • /
    • 1988
  • The present work is concerned with the improvement of finite element for the analysis of plate bending structures. The element formulation is based upon Mindlin plate concept. The displacement field of this element is formed by adding nonconforming modes to two rotational displacement components of a 'heterosis plate element. The element has the requisite numbers of zero eigenvalues associated with rigid body modes to avoid the spurious zero energy mode. It is shown that the results obtained by the element converged to the exact solutions very rapidly as the mesh is refined and exhibited reliable solutions through numerical studies for standard benchmark problems. This element is shown to overcome the shear locking problem completely in very thin plate situation even for irregular meshes.

  • PDF

Switching Functions Model of a Three-phase Voltage Source Converter (VSC)

  • Fazeli, Seyed Mahdi;Ping, Hew Wooi;Abd Rahim, Nasrudin Bin;Ooi, Boon Teck
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.422-431
    • /
    • 2017
  • The equivalent circuit of a three-leg, four-wire voltage source converter (VSC) is derived using switching functions. Simulations and experiments are conducted (i) to investigate the effects of the zero sequence on VSCs when a three-phase imbalance exists and (ii) to use the consistency of simulations and laboratory experiments to validate the equivalent circuit. The impact of a three-phase imbalance on the VSC has yet to be fully investigated because of the lack of an equivalent circuit to show rigorously how the zero sequence currents flow through the VSC.