  • The purpose of the study is to identify the differences about knowledge and attitude between the subjects exposed to pc pornography and the control group not exposed to pc pornography. The study was executed from July 12 through July 16. The subjects were 423 middle school boys. The comparison points were their ethical sexual knowledges and sexual attitudes. The collected data was analysed by SPSS WIN(including multiplicand, percentage, χ²-test, revised Fisher and t-test). The results of their study were as follows ; 1. The pc-related characteristics of the subjects. The subjects exposed pc pornography showed 51.8% rate of exposure to printed pornography. The control group showed the rate of 26.4%. The former group owned their pc(81.5%), however, the latter group showed 66.7%. The former group set their pc sets in their study rooms(66.1%) however, the latter group installed those in their study rooms(73.6%). The former group experienced internet pc communications(62.5%),however, the latter group showed 40.2%. The former group made use of their pc sets in recreation(entertainment) programs(77.0%), however, the latter group showed the rate of 67.8%. The former group showed that their school performance levelled up after their pc manipulation(80.0%), however, the latter group showed the rate of 86.2%. The former group replied that their pc manipulation contributed to their friendship(50.3%), however, the latter group showed the higher rate of 74.7%. The both groups replied that their family dialogs and contacts rather reduced (78.9% and 78.2% respectively). The both groups revealed that they reduced the TV watching the rate 76.5% and 48.3% respectively. The differences between two groups were surveyed in the level of 95% significance and the items such as 'contacts to printed pornography, pc possession or none, pc use rate, friendship occasions and the reduced time of TV watching' showed the significant differences. 2. The differences of two groups' sexual knowledges. As to the sexual knowledges, the both groups showed 41.1 and 34.1 points against 100 points respectively. The statistical differences were significant(t=2.72, p=.007). The 5 items among 17 showed the significant differences between two groups. 'The concept of masturbation' was χ²=5.033, p=.025. 'The prejudice to masturbation' showed χ²=9.902, p=.002 'The difference between female and male as to sexual excitement' showed χ²=7.985, p=.005. 'The positiveness of masturbation' showed χ²=10.205, p=.001. 'The differences between two sexes as to sexual impulse and sexual desire' showed χ²=8.463, p=.004. In conclusion, The former group showed the higher knowledges than the latter group. 3. The differences of two groups' sexual attitudes. The 4 items such as 'the curiosity to the other sex'(t=2.22, p=.027), 'the attention to pornography'(t=3.39, p=.001), 'the permission to pre-marriage intercourse'(t=2.15, p=.032) and 'the preference to the female body exposure'(t=2.67, p=.008) showed the differences between two groups as to sexual attitudes.

  • PDF

Shear Bond Strength Comparison of Different Adhesive Systems to Calcium Silicate-based Materials (Calcium Silicate-based 재료에 대한 수 종 상아질 접착제의 전단결합강도 비교)

  • Shin, Hyunok;Kim, Misun;Nam, Okhyung;Lee, Hyoseol;Choi, Sungchul;Kim, Kwangchul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.4
    • /
    • pp.445-454
    • /
    • 2018
  • The aim of this study was to measure the shear bond strength (SBS) of different adhesive systems to calcium silicate-based materials (Biodentine and RetroMTA). Eighty cylindrical acrylic blocks, with a hole (5.0 mm diameter, 2.0 mm height) in each, were prepared. The holes were filled with Biodentine (BD) and RetroMTA (RMTA), and the specimens were divided into 2 groups. Each group was classified into 4 subgroups: Clearfil$^{TM}$ SE (CSE) ; AQ bond (AQ) ; All bond universal Self-etch (ABU-SE) ; and All bond universal Total-etch (ABU-TE). After the application of different adhesive systems, composite resin (Z350) was applied over BD and RMTA. The SBS was measured using a universal testing machine, and the data were compared using the Kruskal-Wallis test and the Mann-Whitney test. The highest and lowest values of SBS were observed for BD-ABU-SE and RMTA-AQ, respectively. No significant differences were found in the SBS between ABU-TE and ABU-SE and between ABU-TE and CSE to BD and RMTA. According to the data, BD showed a higher SBS than did RMTA when BD and RMTA are compared in the same adhesive agents. Further, among all groups, composite resin with ABU-SE showed better bond strength to BD and RMTA.

EFFECT OF CALCIUM HYDROXIDE ON BOND STRENGTH OF DENTIN BONDING SYSTEMS (수산화칼슘 적용에 따른 상아질 접착제의 접착강도 변화에 관한 연구)

  • Park, No-Hoon;Park, Sang-Hyuk;Choi, Gi-Woon;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.198-207
    • /
    • 2007
  • The purpose of this study was to investigate the effect of calcium hydroxide on dentin bonding strength of various dentin bonding systems as a function of time in composite resin restoration. Dentin adhesives used in this study were Scotchbond Multipurpose, Single Bond, SE Bond and Prompt L-Pop. Flat dentin surfaces adjacent to pulp chamber were created, then $Ca(OH)_2$ and saline were mixed and applied on dentin surface of experimental group, then IRM was used to cover the mixture on dentin surface and the specimens were stored at $36.5^{\circ}C$ for experiment period (7 days, 30 days). After removing IRM and $Ca(OH)_2$, each dentin adhesives were treated on dentin surfaces. Composite resin (Z-250, 3M) was placed with S mm height and was light-cured for 20 seconds. After stored in distilled water for 24 hours, each dentin-composite bonded spicemen was embedded in epoxy resin and sectioned into $1.0\times1.0mm^2$ cross section composite-dentin beams. Specimen was mounted on zig of Universal testing machine and ${\mu}TBS$ test was performed. SEM analysis was performed to examine the fractured surfaces. The results suggested that applying calcium hydroxide did not show significant difference in dentin bonding strength.

EFFECT OF A DESENSITIZER ON MICROTENSILE BOND STRENGTH OF DIFFERENT ADHESIVES (지각과민억제제 적용이 수종 접착제의 미세인장결합강도에 미치는 영향)

  • Hwang, Sung-Yeon;Lee, Kyung-Ha;Yu, Mi-Kyung;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.5
    • /
    • pp.378-384
    • /
    • 2003
  • This study evaluated the influence of a desensitizer(MS coat) on microtensile bond strength of different adhesives:a three-step adhesive(All-Bond 2), a two-step adhesive(Single Bond), a one-step adhesive(One-up Bond F). Non-caries extracted human molars were used. Dentin surface was obtained by horizontal section on mid-portion of crown using a water-cooled low speed diamond saw. Teeth were randomly divided into 6 group. AMO(MS coat + All Bond), SMO(MS coat + Single Bond)- and OMO(MS coat + One-up Bond F)-dentin surface were treated with 17% EDTA before bonded adhesive. AMX-, SMX- and OMX-dentin surface were bonded with All-Bond 2, Single Bond and One-up Bond F, respectively. with no previous treatment with MS coat and 17% EDTA. About 1cm high resin composite($Z-250^{TM}$) were incrementally build-up on the treated surface. The specimens for the microtensile test were serially sectioned perpendicular to the adhesive layer to obtain $0.7{\times}0.7mm$ sticks. 30 sticks were prepared from each group. After that. tensile bond strength for each stick was measured with Microtensile Tester at a 1mm/min crosshead speed. Fractured dentin surfaces were observed under the SEM. The results were statistically analysed by using a One-way ANOVA and Tukey's test(p<0.05). Value in MPa were: $AMO-44.35{\pm}13.21;{\;}SMO-39.35{\pm}13.32;{\;}OMO-31.07{\pm}10.25;{\;}AMX-49.22{\pm}16.38;{\;}SMX-56.02{\pm}13.35;{\;}OMX-72.93{\pm}16.19$. Application of MS coat reduced microtensile bond strengths of both Single Bond and One-up Bond F, whereas microtensile bond strengths of All-Bond 2 were not affected significantly.

A Quality Stability Estimation of Shock-absorber Tube for automatic drawer (자동서랍함용 완충기 튜브의 품질 안정성 예측)

  • Son, Jae-Hwan;Kim, Young-Suk;Han, Chang-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.2919-2924
    • /
    • 2011
  • The automatic drawer is used to absorb the movement shock and adjust its velocity when it opens and closes. The tube in shock-absorber is the cylindrical case which surrounds its parts and is made of acetal. The purpose of this study is to determine the quality stability of the tube in the shock-absorber in injection molding process. The tube which had been manufactured in the process with 4 cavity cooling unit was used. In this study, the analysis and test are carried out to determine its quality stability. Which are the quality analysis with numerical simulation and performance tests of the tube compared with one of foreign make. It is calculated that the injection press is 87.6 MPa and the deflections in X, Y, Z directions are ranged in 0.07~1.00 mm. When the researched tube is compared with the foreign made tube, the maximum bending compressive load is 231 kgf higher, average axial compressive load is 0.05 kgf higher, and the roughness(Ra) on the inner surface is $0.02\;{\mu}m$. lower. In the result, it is known that the quality of researched tube in injection mold process is stable and its performance is superior.

A Comparison of the Effects of Silica and Hydroxyapatite Nanoparticles on Poly(ε-caprolactone)-Poly(ethylene glycol)-Poly(ε-caprolactone)/Chitosan Nanofibrous Scaffolds for Bone Tissue Engineering

  • Hokmabad, Vahideh Raeisdasteh;Davaran, Soodabeh;Aghazadeh, Marziyeh;Alizadeh, Effat;Salehi, Roya;Ramazani, Ali
    • Tissue Engineering and Regenerative Medicine
    • /
    • v.15 no.6
    • /
    • pp.735-750
    • /
    • 2018
  • BACKGROUND: The major challenge of tissue engineering is to develop constructions with suitable properties which would mimic the natural extracellular matrix to induce the proliferation and differentiation of cells. Poly(${\varepsilon}$-caprolactone)-poly(ethylene glycol)-poly(${\varepsilon}$-caprolactone) (PCL-PEG-PCL, PCEC), chitosan (CS), nano-silica ($n-SiO_2$) and nano-hydroxyapatite (n-HA) are biomaterials successfully applied for the preparation of 3D structures appropriate for tissue engineering. METHODS: We evaluated the effect of n-HA and $n-SiO_2$ incorporated PCEC-CS nanofibers on physical properties and osteogenic differentiation of human dental pulp stem cells (hDPSCs). Fourier transform infrared spectroscopy, field emission scanning electron microscope, transmission electron microscope, thermogravimetric analysis, contact angle and mechanical test were applied to evaluate the physicochemical properties of nanofibers. Cell adhesion and proliferation of hDPSCs and their osteoblastic differentiation on nanofibers were assessed using MTT assay, DAPI staining, alizarin red S staining, and QRT-PCR assay. RESULTS: All the samples demonstrated bead-less morphologies with an average diameter in the range of 190-260 nm. The mechanical test studies showed that scaffolds incorporated with n-HA had a higher tensile strength than ones incorporated with $n-SiO_2$. While the hydrophilicity of $n-SiO_2$ incorporated PCEC-CS nanofibers was higher than that of samples enriched with n-HA. Cell adhesion and proliferation studies showed that n-HA incorporated nanofibers were slightly superior to $n-SiO_2$ incorporated ones. Alizarin red S staining and QRT-PCR analysis confirmed the osteogenic differentiation of hDPSCs on PCEC-CS nanofibers incorporated with n-HA and $n-SiO_2$. CONCLUSION: Compared to other groups, PCEC-CS nanofibers incorporated with 15 wt% n-HA were able to support more cell adhesion and differentiation, thus are better candidates for bone tissue engineering applications.

MARGINAL MICROLEAKAGE AND SHEAR BOND STRENGTH OF COMPOSITE RESIN ACCORDING TO TREATMENT METHODS OF ARTIFICIAL SALIVA-CONTAMINATED SURFACE AFTER PRIMING (접착강화제 도포후 인공타액에 오염된 표면의 처리방법에 따른 복합레진의 번연누출과 전단결합강도)

  • Cho, Young-Gon;Ko, Kee-Jong;Lee, Suk-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.46-55
    • /
    • 2000
  • During bonding procedure of composite resin, the prepared cavity can be contaminated by saliva. In this study, marginal microleakage and shear bond strength of a composite resin to primed enamel and dentin treated with artificial saliva(Taliva$^{(R)}$) were evaluated. For the marginal microleakage test, Class V cavities were prepared in the buccal surfaces of fifty molars. The samples were randomly assigned into 5 groups with 10 samples in each group. Control group was applied with a bonding system (Scotchbond$^{TM}$ Multi-Purpose plus) according to manufacture's directions without saliva contamination. Experimental groups were divided into 4 groups and contaminated with artificial saliva for 30 seconds after priming: Experimental 1 group ; artificial saliva was dried with compressed air only, Experimental 2 group ; artificial saliva was rinsed and dried. Experimental 3 group ; cavities were etched with 35% phosphoric acid for 15 seconds after rinsing and drying artificial saliva. Experimental 4 group ; cavities were etched with 35% phosphoric acid for 15 seconds and primer was reapplied after rinsing and drying artificial saliva. All the cavities were applied a bonding agent and filled with a composite resin (Z-100$^{TM}$). Specimens were immersed in 0.5% basic fuschin dye for 24 hours and embedded in transparent acrylic resin and sectioned buccolingually with diamond wheel saw. Four sections were obtained from one specimen. Degree of marginal leakage was scored under stereomicroscope and their scores were averaged from four sections. The data were analyzed by Kruscal-Wallis test and Fisher's LSD. For the shear bond strength test, the buccal or occlusal surfaces of one hundred molar teeth were ground to expose enamel(n=50) or dentin(n=50) using diamond wheel saw and its surface was smoothed with Lapping and Polishing Machine(South Bay Technology Co., U.S.A.). Samples were divided into 5 groups. Treatment of saliva-contaminated enamel and dentin surfaces was same as the marginal microleakage test and composite resin was bonded via a gelatin capsule. All specimens were stored in distilled water for 48 hours. The shear bond strengths were measured by universal testing machine (AGS-1000 4D, Shimaduzu Co., Japan) with a crosshead speed of 5 mm/minute. Failure mode of fracture sites was examined under stereomicroscope. The data were analyzed by ANOVA and Tukey's studentized range test. The results of this study were as follows : 1. Enamel marginal microleakage showed no significant difference among groups. 2. Dentinal marginal microleakages of control, experimental 2 and 4 groups were lower than those of experimental 1 and 3 groups (p<0.05). 3. The shear bond strength to enamel was the highest value in control group (20.03${\pm}$4.47MPa) and the lowest value in experimental 1 group (13.28${\pm}$6.52MPa). There were significant differences between experimental 1 group and other groups (p<0.05). 4. The shear bond strength to dentin was higher in control group (17.87${\pm}$4.02MPa) and experimental 4 group (16.38${\pm}$3.23MPa) than in other groups, its value was low in experimental 1 group (3.95${\pm}$2.51 MPa) and experimental 2 group (6.72${\pm}$2.26MPa)(p<0.05). 5. Failure mode of fractured site on the enamel showed mostly adhesive failures in experimental 1 and 3 groups. 6. Failure mode of fractured site on the dentin did not show adhesive failures in control group, but showed mostly adhesive failure in experimental groups. As a summary of above results, if the primed tooth surface was contaminated with artificial saliva, primer should be reapplied after re-etching it.

  • PDF

Antimutagenic Effects of Korean Bamboo Trees and Inhibitory Effect of Hepatic Toxicity of Bamboo Extracts Coated Rice (한국산 대나무의 항돌연변이 효과 및 대나무 코팅쌀의 간 독성 억제효과)

  • Lee, Min-Ja;Kim, Eun-Young;Jeong, Keun-Ok;Park, Kun-Young;Moon, Gap-Soon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.8
    • /
    • pp.1279-1285
    • /
    • 2004
  • To evaluate the antimutagenic effect and hepato protective of bamboo trees and bamboo byproduct, hot-water extracts from four kinds of bamboo [wang-dae (Phyllostachys bambusoides S. et Z.), som-dae (Phyllostachys nigra var. henonis), maengjong-juk (Phyllostachys pubescens) and o-juk (Phyllostachys nigra Munro)] and maengjong-juk extract coated rice were evaluated for antimutagenicity by Ames test using Salmonella typhimurium TA100. Bamboo extracts showed strong antimutagenic activity in the Ames test which MNNG was used as mutagen in the absence and presence of S9 mix. Maengjong-juk extract coated rice diet suppressed the loss of body weight significantly. Food intake was increased in maengjong-juk extract coated rice supplemented group but showed no significant differences between control and maengjong-juk extract coated rice diet groups. Food efficiency of maengjong-juk extract coated rice supplemented group was significantly higher than that of the control group. Liver weight was significantly increased by maengjong-juk extract coated rice diet administration. Plasma GOT & GPT activities of rabbit were significantly suppressed in maengjong-juk extract coated rice supplemented group. These results suggest that bamboo trees extracts and maengjong-juk extract coated rice are bioavailable resource on treatment of cardiovascular disease, such as atherosclerosis and hypercholesterolemia.

Evaluation of shear-bond strength between different self-adhesive resin cements with phosphate monomer and zirconia ceramic before and after thermocycling (인산염계 기능성 단량체가 첨가된 수종의 자가 접착 레진시멘트와 지르코니아 세라믹 사이 열순환 전후 전단결합강도 비교)

  • Lee, Ji-Hun;Kim, Min-Kyung;Lee, Jung-Jin;Ahn, Seung-Geun;Park, Ju-Mi;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.318-324
    • /
    • 2015
  • Purpose: This study compared shear bond strengths of five self-adhesive cements with phosphate monomer to zirconium oxide ceramic with and without airborn particle abrasion. Materials and methods: One hundred zirconia samples were air-abraded ($50{\mu}mAl_2O_3$). One hundred composite resin cylinders were fabricated. Composite cylinders were bonded to the zirconia samples with either Permacem 2.0 (P), $Clearfil^{TM}$ SA Luting (C), $Multilink^{(R)}$ Speed (M), $RelyX^{TM}$ U200 Automix (R), G-Cem $LinkAce^{TM}$ (G). All bonded specimens were stored in distilled water ($37^{\circ}C$) for 24 h and half of them were additionally aged by thermocycling ($5^{\circ}C$, $55^{\circ}C$, 5,000 times). The bonded specimens were loaded in shear force until fracture (1 mm/min) by using Universal Testing Machine (Model 4201, Instron Co, Canton, MA, USA). The failure sites were inspected under field-emission scanning electron microscopy. The data was analyzed with ANOVA, Tukey HSD post-hoc test and paired samples t-test ($\alpha$=.05). Results: Before and after thermocycling, $Multilink^{(R)}$ Speed (M) revealed higher shear-bond strength than the other cements. G-Cem $LinkAce^{TM}$ (G) showed significantly lower bond strengths after thermocycling than before treatment (P<.05), but the other groups were not significantly different (P>.05). Conclusion: Most self-adhesive cements with phosphate monomer showed high shear bond strength with zirconia ceramic and weren't influenced by thermocycling, so they seem to valuable to zirconia ceramic bonding.

Influence of air abrasion and different dentin sealing techniques on microtensile bond strength to dentin (상아질의 봉쇄 시기와 표면처리 방법이 미세인장 결합강도에 미치는 영향)

  • Kang, Dong-Ho;Han, Chong-Hyun;Park, Jung-Won;Kim, Sun-Jai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.8-15
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the effect of various methods of dentin bonding agent application and air abrasion pretreatment on microtensile bond strength between dentin and resin, using a self-etching adhesive system. Material and methods: Thirty freshly extracted human molars were obtained and divided into 6 groups of 5 teeth. A 2-step self etching adhesive system (Clearfil SE Bond) was used for all groups. The control specimens were prepared using a direct immediate bonding technique. The delayed dentin sealing specimens were prepared using an indirect approach without dentin prebonding. The immediate dentin sealing specimens were prepared using dentin prebonding immediately following preparation. Immediate dentin sealing teeth and delayed dentin sealing teeth had provisional restorations using Fermit for two weeks. Then all specimens of each group were divided into two groups of three, depending on air abrasion pretreatment. Composite "crowns" were incrementally built on and specimens were stored in water for 24 hours. All teeth were prepared for a microtensile bond strength test. Bond strength data were analyzed with a one-way ANOVA test, and post hoc comparison was done using the Scheffe's test. Results: The mean microtensile bond strengths of all groups were not statistically different from each other. Conclusion: When preparing teeth for indirect restorations, IDS and DDS with Clearfil SE bond, have no difference on the microtensile bond strength between dentin and resin. Air abrasion pretreatment did not affect the microtensile bond strength when using IDS and DDS with Clearfil SE bond.